Elvis Duran-Sierra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elvis Duran-Sierra has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Javier A. Jo
Affiliation School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma, United States of America
4 shared publications- Javier A. Jo
School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA
4 shared publications Shuna Cheng
Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
4 shared publications- Beena Ahmed
Department of Electrical Engineering and Telecommunications, Faculty of Engineering, The University of New South Wales, Sydney, Australia
3 shared publications Beena Ahmed
Department of Electrical and Computer Engineering, Texas A&M University at Qatar, Doha, Qatar
2 shared publicationsBilal Malik
QT Ultrasound Labs, 3 Hamilton Landing, Suite 160, Novato, CA, USA
2 shared publications
Latest Publications
- Open Access
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (02) , 025001-11
Computer-assisted discrimination of cancerous and pre-cancerous from benign oral lesions based on multispectral autofluorescence imaging endoscopy
SignificanceDiagnosis of cancerous and pre-cancerous oral lesions at early stages is critical for the improvement of patient care, to increase survival rates and minimize the invasiveness of tumor resection surgery. Unfortunately, oral precancerous and early-stage cancerous lesions are often difficult to distinguish from oral benign lesions with the existing diagnostic tools used during standard clinical oral examination. In consequence, early diagnosis of oral cancer can be achieved in only about 30% of patients. Therefore, clinical diagnostic technologies for fast, minimally invasive, and accurate oral cancer screening are urgently needed.AimThis study investigated the use of multispectral autofluorescence imaging endoscopy for the automated and noninvasive discrimination of cancerous and precancerous from benign oral epithelial lesions.ApproachIn vivo multispectral autofluorescence endoscopic images of clinically suspicious oral lesions were acquired from 67 patients undergoing tissue biopsy examination. The imaged lesions were classified as precancerous (n=4), cancerous (n=29), and benign (n=34) lesions based on histopathology diagnosis. Multispectral autofluorescence intensity feature maps were generated for each oral lesion and used to train and optimize support vector machine (SVM) models for automated discrimination of cancerous and precancerous from benign oral lesions.ResultsAfter a leave-one-patient-out cross-validation strategy, an optimized SVM model developed with four multispectral autofluorescence features yielded levels of sensitivity and specificity of 85% and 71%, respectively and overall accuracy of 78% in the discrimination of cancerous/precancerous versus benign oral lesions.ConclusionThis study demonstrates the potentials of a computer-assisted detection system based on multispectral autofluorescence imaging endoscopy for the early detection of cancerous and precancerous oral lesions.
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (02) , 025001-11
Open AccessComputer-assisted discrimination of cancerous and pre-cancerous from benign oral lesions based on multispectral autofluorescence imaging endoscopy
SignificanceDiagnosis of cancerous and pre-cancerous oral lesions at early stages is critical for the improvement of patient care, to increase survival rates and minimize the invasiveness of tumor resection surgery. Unfortunately, oral precancerous and early-stage cancerous lesions are often difficult to distinguish from oral benign lesions with the existing diagnostic tools used during standard clinical oral examination. In consequence, early diagnosis of oral cancer can be achieved in only about 30% of patients. Therefore, clinical diagnostic technologies for fast, minimally invasive, and accurate oral cancer screening are urgently needed.AimThis study investigated the use of multispectral autofluorescence imaging endoscopy for the automated and noninvasive discrimination of cancerous and precancerous from benign oral epithelial lesions.ApproachIn vivo multispectral autofluorescence endoscopic images of clinically suspicious oral lesions were acquired from 67 patients undergoing tissue biopsy examination. The imaged lesions were classified as precancerous (n=4), cancerous (n=29), and benign (n=34) lesions based on histopathology diagnosis. Multispectral autofluorescence intensity feature maps were generated for each oral lesion and used to train and optimize support vector machine (SVM) models for automated discrimination of cancerous and precancerous from benign oral lesions.ResultsAfter a leave-one-patient-out cross-validation strategy, an optimized SVM model developed with four multispectral autofluorescence features yielded levels of sensitivity and specificity of 85% and 71%, respectively and overall accuracy of 78% in the discrimination of cancerous/precancerous versus benign oral lesions.ConclusionThis study demonstrates the potentials of a computer-assisted detection system based on multispectral autofluorescence imaging endoscopy for the early detection of cancerous and precancerous oral lesions.
- Open Access
Machine-Learning Assisted Discrimination of Precancerous and Cancerous from Healthy Oral Tissue Based on Multispectral Autofluorescence Lifetime Imaging Endoscopy
Multispectral autofluorescence lifetime imaging (maFLIM) can be used to clinically image a plurality of metabolic and biochemical autofluorescence biomarkers of oral epithelial dysplasia and cancer. This study tested the hypothesis that maFLIM-derived autofluorescence biomarkers can be used in machine-learning (ML) models to discriminate dysplastic and cancerous from healthy oral tissue. Clinical widefield maFLIM endoscopy imaging of cancerous and dysplastic oral lesions was performed at two clinical centers. Endoscopic maFLIM images from 34 patients acquired at one of the clinical centers were used to optimize ML models for automated discrimination of dysplastic and cancerous from healthy oral tissue. A computer-aided detection system was developed and applied to a set of endoscopic maFLIM images from 23 patients acquired at the other clinical center, and its performance was quantified in terms of the area under the receiver operating characteristic curve (ROC-AUC). Discrimination of dysplastic and cancerous from healthy oral tissue was achieved with an ROC-AUC of 0.81. This study demonstrates the capabilities of widefield maFLIM endoscopy to clinically image autofluorescence biomarkers that can be used in ML models to discriminate dysplastic and cancerous from healthy oral tissue. Widefield maFLIM endoscopy thus holds potential for automated in situ detection of oral dysplasia and cancer.
Open AccessMachine-Learning Assisted Discrimination of Precancerous and Cancerous from Healthy Oral Tissue Based on Multispectral Autofluorescence Lifetime Imaging Endoscopy
Multispectral autofluorescence lifetime imaging (maFLIM) can be used to clinically image a plurality of metabolic and biochemical autofluorescence biomarkers of oral epithelial dysplasia and cancer. This study tested the hypothesis that maFLIM-derived autofluorescence biomarkers can be used in machine-learning (ML) models to discriminate dysplastic and cancerous from healthy oral tissue. Clinical widefield maFLIM endoscopy imaging of cancerous and dysplastic oral lesions was performed at two clinical centers. Endoscopic maFLIM images from 34 patients acquired at one of the clinical centers were used to optimize ML models for automated discrimination of dysplastic and cancerous from healthy oral tissue. A computer-aided detection system was developed and applied to a set of endoscopic maFLIM images from 23 patients acquired at the other clinical center, and its performance was quantified in terms of the area under the receiver operating characteristic curve (ROC-AUC). Discrimination of dysplastic and cancerous from healthy oral tissue was achieved with an ROC-AUC of 0.81. This study demonstrates the capabilities of widefield maFLIM endoscopy to clinically image autofluorescence biomarkers that can be used in ML models to discriminate dysplastic and cancerous from healthy oral tissue. Widefield maFLIM endoscopy thus holds potential for automated in situ detection of oral dysplasia and cancer.
- Open Access
- 18 March 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (3) , e0248301
Blind deconvolution estimation by multi-exponential models and alternated least squares approximations: Free-form and sparse approach
The deconvolution process is a key step for quantitative evaluation of fluorescence lifetime imaging microscopy (FLIM) samples. By this process, the fluorescence impulse responses (FluoIRs) of the sample are decoupled from the instrument response (InstR). In blind deconvolution estimation (BDE), the FluoIRs and InstR are jointly extracted from a dataset with minimal a priori information. In this work, two BDE algorithms are introduced based on linear combinations of multi-exponential functions to model each FluoIR in the sample. For both schemes, the InstR is assumed with a free-form and a sparse structure. The local perspective of the BDE methodology assumes that the characteristic parameters of the exponential functions (time constants and scaling coefficients) are estimated based on a single spatial point of the dataset. On the other hand, the same exponential functions are used in the whole dataset in the global perspective, and just the scaling coefficients are updated for each spatial point. A least squares formulation is considered for both BDE algorithms. To overcome the nonlinear interaction in the decision variables, an alternating least squares (ALS) methodology iteratively solves both estimation problems based on non-negative and constrained optimizations. The validation stage considered first synthetic datasets at different noise types and levels, and a comparison with the standard deconvolution techniques with a multi-exponential model for FLIM measurements, as well as, with two BDE methodologies in the state of the art: Laguerre basis, and exponentials library. For the experimental evaluation, fluorescent dyes and oral tissue samples were considered. Our results show that local and global perspectives are consistent with the standard deconvolution techniques, and they reached the fastest convergence responses among the BDE algorithms with the best compromise in FluoIRs and InstR estimation errors.
- 18 March 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (3) , e0248301
Open AccessBlind deconvolution estimation by multi-exponential models and alternated least squares approximations: Free-form and sparse approach
The deconvolution process is a key step for quantitative evaluation of fluorescence lifetime imaging microscopy (FLIM) samples. By this process, the fluorescence impulse responses (FluoIRs) of the sample are decoupled from the instrument response (InstR). In blind deconvolution estimation (BDE), the FluoIRs and InstR are jointly extracted from a dataset with minimal a priori information. In this work, two BDE algorithms are introduced based on linear combinations of multi-exponential functions to model each FluoIR in the sample. For both schemes, the InstR is assumed with a free-form and a sparse structure. The local perspective of the BDE methodology assumes that the characteristic parameters of the exponential functions (time constants and scaling coefficients) are estimated based on a single spatial point of the dataset. On the other hand, the same exponential functions are used in the whole dataset in the global perspective, and just the scaling coefficients are updated for each spatial point. A least squares formulation is considered for both BDE algorithms. To overcome the nonlinear interaction in the decision variables, an alternating least squares (ALS) methodology iteratively solves both estimation problems based on non-negative and constrained optimizations. The validation stage considered first synthetic datasets at different noise types and levels, and a comparison with the standard deconvolution techniques with a multi-exponential model for FLIM measurements, as well as, with two BDE methodologies in the state of the art: Laguerre basis, and exponentials library. For the experimental evaluation, fluorescent dyes and oral tissue samples were considered. Our results show that local and global perspectives are consistent with the standard deconvolution techniques, and they reached the fastest convergence responses among the BDE algorithms with the best compromise in FluoIRs and InstR estimation errors.
- 2 April 2020
- Published by Elsevier in Oral Oncology
- Vol. 105, 104635
Clinical label-free biochemical and metabolic fluorescence lifetime endoscopic imaging of precancerous and cancerous oral lesions
- 2 April 2020
- Published by Elsevier in Oral Oncology
- Vol. 105, 104635
Clinical label-free biochemical and metabolic fluorescence lifetime endoscopic imaging of precancerous and cancerous oral lesions
- Open Access
- 12 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 178539-178552
Extended Blind End-Member and Abundance Extraction for Biomedical Imaging Applications
In some applications of biomedical imaging, a linear mixture model can represent the constitutive elements (end-members) and their contributions (abundances) per pixel of the image. In this work, the extended blind end-member and abundance extraction (EBEAE) methodology is mathematically formulated to address the blind linear unmixing (BLU) problem subject to positivity constraints in optical measurements. The EBEAE algorithm is based on a constrained quadratic optimization and an alternated least-squares strategy to jointly estimate end-members and their abundances. In our proposal, a local approach is used to estimate the abundances of each end-member by maximizing their entropy, and a global technique is adopted to iteratively identify the end-members by reducing the similarity among them. All the cost functions are normalized, and four initialization approaches are suggested for the end-members matrix. Synthetic datasets are used first for the EBEAE validation at different noise types and levels, and its performance is compared to state-of-the-art algorithms in BLU. In a second stage, three experimental biomedical imaging applications are addressed with EBEAE: m-FLIM for chemometric analysis in oral cavity samples, OCT for macrophages identification in post-mortem artery samples, and hyper-spectral images for in-vivo brain tissue classification and tumor identification. In our evaluations, EBEAE was able to provide a quantitative analysis of the samples with none or minimal a priori information.
- 12 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 178539-178552
Open AccessExtended Blind End-Member and Abundance Extraction for Biomedical Imaging Applications
In some applications of biomedical imaging, a linear mixture model can represent the constitutive elements (end-members) and their contributions (abundances) per pixel of the image. In this work, the extended blind end-member and abundance extraction (EBEAE) methodology is mathematically formulated to address the blind linear unmixing (BLU) problem subject to positivity constraints in optical measurements. The EBEAE algorithm is based on a constrained quadratic optimization and an alternated least-squares strategy to jointly estimate end-members and their abundances. In our proposal, a local approach is used to estimate the abundances of each end-member by maximizing their entropy, and a global technique is adopted to iteratively identify the end-members by reducing the similarity among them. All the cost functions are normalized, and four initialization approaches are suggested for the end-members matrix. Synthetic datasets are used first for the EBEAE validation at different noise types and levels, and its performance is compared to state-of-the-art algorithms in BLU. In a second stage, three experimental biomedical imaging applications are addressed with EBEAE: m-FLIM for chemometric analysis in oral cavity samples, OCT for macrophages identification in post-mortem artery samples, and hyper-spectral images for in-vivo brain tissue classification and tumor identification. In our evaluations, EBEAE was able to provide a quantitative analysis of the samples with none or minimal a priori information.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 3009-3012
Endogenous Fluorescence Lifetime Imaging (FLIM) Endoscopy For Early Detection Of Oral Cancer And Dysplasia
We have performed a pilot clinical study, in which multispectral endogenous fluorescence (or autofluorescence) lifetime imaging (FLIM) was performed on clinically suspicious oral lesions of 73 patients undergoing tissue biopsy for oral dysplasia and cancer diagnosis. The results from this pilot study indicated that mild-dysplasia and early stage oral cancer could be detected from benign lesions using a computed aided diagnosis system developed based on biochemical and metabolic biomarkers derived from the endogenous FLIM images. The diagnostic performance of this novel FLIM clinical tool was estimated using a leave-onepatient-out cross-validation approach, which reported levels of sensitivity >90%, specificity >85%, and Area Under the Receiving Operating Curve (ROC-AUC) >0.9.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 3009-3012
Endogenous Fluorescence Lifetime Imaging (FLIM) Endoscopy For Early Detection Of Oral Cancer And Dysplasia
We have performed a pilot clinical study, in which multispectral endogenous fluorescence (or autofluorescence) lifetime imaging (FLIM) was performed on clinically suspicious oral lesions of 73 patients undergoing tissue biopsy for oral dysplasia and cancer diagnosis. The results from this pilot study indicated that mild-dysplasia and early stage oral cancer could be detected from benign lesions using a computed aided diagnosis system developed based on biochemical and metabolic biomarkers derived from the endogenous FLIM images. The diagnostic performance of this novel FLIM clinical tool was estimated using a leave-onepatient-out cross-validation approach, which reported levels of sensitivity >90%, specificity >85%, and Area Under the Receiving Operating Curve (ROC-AUC) >0.9.
- 14 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10469, 104690N
Autofluorescence lifetime imaging endoscopy for automated label-free early detection of oral epithelial cancer and dysplasia (Conference Presentation)
Despite the fact that the oral cavity is easily accessible, only ~30% of oral cancers are diagnosed at an early stage, which is the main factor attributed to the low 5-year survival rate (63%) of oral cancer patients. Several screening tools for oral cancer have been commercially available; however, none of them have been demonstrated to have sufficient sensitivity and specificity for early detection of oral cancer and dysplasia. We hypothesized that an array of biochemical and metabolic biomarkers for oral cancer and dysplasia can be quantified by endogenous fluorescence lifetime imaging (FLIM), thus enabling levels of sensitivity and specificity adequate for early detection of oral cancer and dysplasia. Our group has recently developed multispectral FLIM endoscopes to image the oral cavity with unprecedented imaging speed (>2fps). We have also performed an in vivo pilot study, in which endogenous multispectral FLIM images were acquired from clinically suspicious oral lesions of 70 patients undergoing tissue biopsy. The results from this pilot study indicated that mild-dysplasia and early stage oral cancer could be detected from benign lesions using a computed aided diagnosis (CAD) system developed based on biochemical and metabolic biomarkers that could be quantified from endogenous multispectral FLIM images. The diagnostic performance of this novel FLIM based clinical tool was estimated using a cross-validation approach, showing levels of sensitivity >90%, specificity >80%, and Area Under the Receiving Operating Curve (RO- AUC) >0.9. Future efforts are focused on developing cost-effective FLIM endoscopes and validating this novel clinical tool in prospective multi-center clinical studies.
- 14 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10469, 104690N
Autofluorescence lifetime imaging endoscopy for automated label-free early detection of oral epithelial cancer and dysplasia (Conference Presentation)
Despite the fact that the oral cavity is easily accessible, only ~30% of oral cancers are diagnosed at an early stage, which is the main factor attributed to the low 5-year survival rate (63%) of oral cancer patients. Several screening tools for oral cancer have been commercially available; however, none of them have been demonstrated to have sufficient sensitivity and specificity for early detection of oral cancer and dysplasia. We hypothesized that an array of biochemical and metabolic biomarkers for oral cancer and dysplasia can be quantified by endogenous fluorescence lifetime imaging (FLIM), thus enabling levels of sensitivity and specificity adequate for early detection of oral cancer and dysplasia. Our group has recently developed multispectral FLIM endoscopes to image the oral cavity with unprecedented imaging speed (>2fps). We have also performed an in vivo pilot study, in which endogenous multispectral FLIM images were acquired from clinically suspicious oral lesions of 70 patients undergoing tissue biopsy. The results from this pilot study indicated that mild-dysplasia and early stage oral cancer could be detected from benign lesions using a computed aided diagnosis (CAD) system developed based on biochemical and metabolic biomarkers that could be quantified from endogenous multispectral FLIM images. The diagnostic performance of this novel FLIM based clinical tool was estimated using a cross-validation approach, showing levels of sensitivity >90%, specificity >80%, and Area Under the Receiving Operating Curve (RO- AUC) >0.9. Future efforts are focused on developing cost-effective FLIM endoscopes and validating this novel clinical tool in prospective multi-center clinical studies.
- 2 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10499, 104991N
Cross-level sampling for bandwidth effective time-domain fluorescence lifetime imaging implementation
The implementation of time domain fluorescence lifetime imaging (TD-FLIM) requires high cost bandwidth electronics and large storage capacity. A cross-level sampling technique for TD-FLIM is proposed. A simulation of this sampling technique was implemented using synthetic FLIM data. FLIM images were synthetically generated at different noise levels using a wide range of lifetimes. Each of the images was resampled using a cross-level approach and the lifetime maps were computed. Simulation results displayed strong correlation between the lifetime maps of the original and resampled images, suggesting that this sampling method could be adopted to reduce bandwidth and data transfer/ storage requirements.
- 2 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10499, 104991N
Cross-level sampling for bandwidth effective time-domain fluorescence lifetime imaging implementation
The implementation of time domain fluorescence lifetime imaging (TD-FLIM) requires high cost bandwidth electronics and large storage capacity. A cross-level sampling technique for TD-FLIM is proposed. A simulation of this sampling technique was implemented using synthetic FLIM data. FLIM images were synthetically generated at different noise levels using a wide range of lifetimes. Each of the images was resampled using a cross-level approach and the lifetime maps were computed. Simulation results displayed strong correlation between the lifetime maps of the original and resampled images, suggesting that this sampling method could be adopted to reduce bandwidth and data transfer/ storage requirements.