Youqiang Pan
Youqiang Pan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hui Zhang
Jiangsu Sinoroad Engineering Research Institute Co., Ltd., Nanjing 211805, China
2 shared publications - Peiwei Gao
Department of Civil and Airport Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
2 shared publications - Zhixiang Zhang
SinoRoad Transportation Science and Technology Co., Ltd., Nanjing 211800, China
2 shared publications - Chengqi Zhou
Jiangsu SinoRoad Engineering Research Institute
1 shared publication - Kuan Li
Nanjing Univ. of Aeronautics and Astronautics
1 shared publication - Weiguang Zhang
School of Transportation, Southeast University, Nanjing 211189, China
1 shared publication
Latest Publications
- Open Access
- 16 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 632
Effects of Parameters of Air-Avid Structure on the Salt-Frost Durability of Hardened Concrete
Through laboratory testing, this research studied the connection between air-void structures of hardened concrete and fresh concrete and discussed the effects of the air-void structure on the salt-frost durability of the concrete. The results demonstrate that, in comparison with fresh concrete, the air-void spacing factor shows a close correlation with hardened concrete air-content and decreases in the form of a power function as the air-content increases. When the fresh concrete air-content is more than 6% and the hardened concrete air-void spacing factor is less than 0.18 mm, the influence of parameters of air-void structure on the salt-frost resistance of the concrete reduces. The air-void spacing factor more significantly affects the salt-frost resistance of the concrete compared with air content and the correlation reaches 0.93. Therefore, air-content and air-void spacing factor are recommended for dual control.
- 16 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 632
Open AccessEffects of Parameters of Air-Avid Structure on the Salt-Frost Durability of Hardened Concrete
Through laboratory testing, this research studied the connection between air-void structures of hardened concrete and fresh concrete and discussed the effects of the air-void structure on the salt-frost durability of the concrete. The results demonstrate that, in comparison with fresh concrete, the air-void spacing factor shows a close correlation with hardened concrete air-content and decreases in the form of a power function as the air-content increases. When the fresh concrete air-content is more than 6% and the hardened concrete air-void spacing factor is less than 0.18 mm, the influence of parameters of air-void structure on the salt-frost resistance of the concrete reduces. The air-void spacing factor more significantly affects the salt-frost resistance of the concrete compared with air content and the correlation reaches 0.93. Therefore, air-content and air-void spacing factor are recommended for dual control.
- Open Access
- 18 December 2019
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2019, 1-13
Material and Structural Properties of Fiber-Reinforced Resin Composites as Thin Overlay for Steel Bridge Deck Pavement
Fatigue cracks are main damages to steel bridge deck pavement with thermosetting epoxy asphalt. By combining a high-toughness resin material with fiber woven fabrics, this study formed an ultrathin overlay of fiber-reinforced high-toughness resin to improve cracking resistance of pavement. Through theoretical measurement and bending test, this research studied change laws of bending and tensile properties of epoxy asphalt concrete after fiber reinforcement and analyzed bending strength and the maximum failure strain of beams at different temperatures. Moreover, the reinforcing effects of different fibers were discussed. It is found that bending strength, maximum failure strain, and stiffness modulus of the beams with epoxy asphalt are improved after fiber reinforcement. With the decrease of temperature, after fiber reinforcement, the mode of bending failure of the epoxy asphalt mixture (EAM) changes from brittle fracture into shear failure, accompanied with significant yield phenomenon. Furthermore, organic carbon fiber is sensitive to influences of temperature, while glass fiber is least sensitive to temperature.
- 18 December 2019
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2019, 1-13
Open AccessMaterial and Structural Properties of Fiber-Reinforced Resin Composites as Thin Overlay for Steel Bridge Deck Pavement
Fatigue cracks are main damages to steel bridge deck pavement with thermosetting epoxy asphalt. By combining a high-toughness resin material with fiber woven fabrics, this study formed an ultrathin overlay of fiber-reinforced high-toughness resin to improve cracking resistance of pavement. Through theoretical measurement and bending test, this research studied change laws of bending and tensile properties of epoxy asphalt concrete after fiber reinforcement and analyzed bending strength and the maximum failure strain of beams at different temperatures. Moreover, the reinforcing effects of different fibers were discussed. It is found that bending strength, maximum failure strain, and stiffness modulus of the beams with epoxy asphalt are improved after fiber reinforcement. With the decrease of temperature, after fiber reinforcement, the mode of bending failure of the epoxy asphalt mixture (EAM) changes from brittle fracture into shear failure, accompanied with significant yield phenomenon. Furthermore, organic carbon fiber is sensitive to influences of temperature, while glass fiber is least sensitive to temperature.