Preeti Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Preeti Gupta has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Narayan Prasad Gupta
Electrical Engineering Department, University Institute of Technology, RGPV, Bhopal, India
5 shared publications Deepika Masand
2 shared publications- Nishant Thakkar
Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
2 shared publications - Pankaj Swarnkar
Maulana Azad National Institute of Technology, Bhopal, India
2 shared publications - Priyanka Paliwal
Electrical Engineering Department, Maulana Azad National Institute of Technology, Bhopal, India
2 shared publications - Kaliyaperumal Deepa
Amrita School of Engineering, Amrita Vishwa Vidyapeetham
1 shared publication
Latest Publications
- 1 August 2024
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (11) , 8211-8231
Design of Universal Control Structure for Regulation of Voltage and Frequency in Hybrid Microgrid
- 1 August 2024
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (11) , 8211-8231
Design of Universal Control Structure for Regulation of Voltage and Frequency in Hybrid Microgrid
- 11 May 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (7) , 8691-8708
A novel scheme for control and management of hybrid microgrid with active filtering capability
- 11 May 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (7) , 8691-8708
A novel scheme for control and management of hybrid microgrid with active filtering capability
- Open Access
- 30 June 2020
- Published by International Information and Engineering Technology Association in European Journal of Electrical Engineering
- Vol. 22 (3) , 241-253
A New Approach Towards Integration of Multi-frequency, Multi-voltage Intertied Hybrid Power System
- 30 June 2020
- Published by International Information and Engineering Technology Association in European Journal of Electrical Engineering
- Vol. 22 (3) , 241-253
Open AccessA New Approach Towards Integration of Multi-frequency, Multi-voltage Intertied Hybrid Power System
- 19 May 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (8)
Adaptive power sharing in multi‐voltage multi‐frequency intertied hybrid power system
- 19 May 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (8)
Adaptive power sharing in multi‐voltage multi‐frequency intertied hybrid power system
- 17 December 2019
- Published by Springer Nature
- p. 75-84
Intelligent Power Sharing Control for Hybrid System
- 17 December 2019
- Published by Springer Nature
- p. 75-84
Intelligent Power Sharing Control for Hybrid System
- 20 February 2018
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 8 (1) , 2609-2615
Intertied AC-DC Hybrid System Power Sharing Through Intelligent Droop Controller
The result of DG clustering is the hybrid power system while further clustering forms the intertied hybrid power system. Interfacing of intertied hybrid power system requires an interlinking converter with a legitimate power administration and control system. In contrast to individual hybrid power system (HPS), power administration of the intertied hybrid system is more complex. Autonomous droop strategy is appropriate for the intertied hybrid system where communication links are not possible. This paper proposes a new topology for control in intertied hybrid system where two hybrid power systems are connected to each other through interlink power converter. Evaluated frequencies in different HPSs can diverse. In order to manage power flow a power management strategy with consideration characteristics of common bus, a PDC-vDC2 method is proposed, and compared with conventional droop, to realize power sharing among HPS. The practicability of the proposed power sharing method is realized in MATLAB/Simulink platform.
- 20 February 2018
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 8 (1) , 2609-2615
Intertied AC-DC Hybrid System Power Sharing Through Intelligent Droop Controller
The result of DG clustering is the hybrid power system while further clustering forms the intertied hybrid power system. Interfacing of intertied hybrid power system requires an interlinking converter with a legitimate power administration and control system. In contrast to individual hybrid power system (HPS), power administration of the intertied hybrid system is more complex. Autonomous droop strategy is appropriate for the intertied hybrid system where communication links are not possible. This paper proposes a new topology for control in intertied hybrid system where two hybrid power systems are connected to each other through interlink power converter. Evaluated frequencies in different HPSs can diverse. In order to manage power flow a power management strategy with consideration characteristics of common bus, a PDC-vDC2 method is proposed, and compared with conventional droop, to realize power sharing among HPS. The practicability of the proposed power sharing method is realized in MATLAB/Simulink platform.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance analysis of direct torque control of PMSM drive using SVPWM - inverter
Permanent magnet synchronous motors (PMSM) have been universally used as variable speed drives due to its characteristics such as small volume, light weight, high efficiency, small inertia and hence high torque / inertia ratio, maintenance free and ease of control, high steady state torque density create possibility of replacing induction machines with PMSMs in industrial drive applications. PMSM are now widely accepted as high performance drives such as industrial robots and machine tools. A novel direct torque control (DTC) scheme incorporating space vector pulse width modulated (SVPWM) inverter, for speed control of PMSM drive has been presented in this paper, which has advantage of fast dynamic response with low ripples in torque and speed response, elimination of current controllers and least dependency on motor parameters. According to the differences in estimated value of torque and stator flux linkage with actual reference value; the stator voltage vectors are directly selected, in DTC to control the speed of motor. Mathematical model of PMSM and proposed DTC scheme is presented here. A simulation model is developed in MATLAB / SIMULINK to judge the various performance parameters.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance analysis of direct torque control of PMSM drive using SVPWM - inverter
Permanent magnet synchronous motors (PMSM) have been universally used as variable speed drives due to its characteristics such as small volume, light weight, high efficiency, small inertia and hence high torque / inertia ratio, maintenance free and ease of control, high steady state torque density create possibility of replacing induction machines with PMSMs in industrial drive applications. PMSM are now widely accepted as high performance drives such as industrial robots and machine tools. A novel direct torque control (DTC) scheme incorporating space vector pulse width modulated (SVPWM) inverter, for speed control of PMSM drive has been presented in this paper, which has advantage of fast dynamic response with low ripples in torque and speed response, elimination of current controllers and least dependency on motor parameters. According to the differences in estimated value of torque and stator flux linkage with actual reference value; the stator voltage vectors are directly selected, in DTC to control the speed of motor. Mathematical model of PMSM and proposed DTC scheme is presented here. A simulation model is developed in MATLAB / SIMULINK to judge the various performance parameters.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23751282,p. 1-6
Power quality improvement using hybrid active power filter for a DFIG based wind energy conversion system
In recent years, there has been a considerable interest in installation of dispersed generation systems such as wind farms. The DFIG based variable speed wind turbine is the most popular in the growing wind market. This machine can be operate either in grid connected or stand alone mode. The interaction between the wind farm and the grid should be in compliance with the power quality standards. The system uses two back-to-back PWM voltage source converters in the rotor circuit designed as grid side converter (GSC) and rotor side converter (RSC). The vector control strategy is used for both converters. These high frequency switching converters of DFIG will inject additional harmonics in the system, which are increasing with wind speed variations. The presence of non linear load will further inject harmonic current and as a consequence, there is a violation of IEEE-519 power quality standard, and chances of damage of power system equipment may increase. As a solution, Hybrid Active Power Filter; a combination of shunt active filter and shunt passive filter is used in conjunction with non linear load. Indirect current control scheme based on hysteresis controller has been used for controlling of active filter. The SAPF eliminates higher order harmonics while most dominant lower order harmonics are filtered out using passive filter. In this paper the performance of wind driven DFIG feeding non linear load with HAPF is analyzed for steady state and dynamic conditions, using MATLAB/Simulink.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23751282,p. 1-6
Power quality improvement using hybrid active power filter for a DFIG based wind energy conversion system
In recent years, there has been a considerable interest in installation of dispersed generation systems such as wind farms. The DFIG based variable speed wind turbine is the most popular in the growing wind market. This machine can be operate either in grid connected or stand alone mode. The interaction between the wind farm and the grid should be in compliance with the power quality standards. The system uses two back-to-back PWM voltage source converters in the rotor circuit designed as grid side converter (GSC) and rotor side converter (RSC). The vector control strategy is used for both converters. These high frequency switching converters of DFIG will inject additional harmonics in the system, which are increasing with wind speed variations. The presence of non linear load will further inject harmonic current and as a consequence, there is a violation of IEEE-519 power quality standard, and chances of damage of power system equipment may increase. As a solution, Hybrid Active Power Filter; a combination of shunt active filter and shunt passive filter is used in conjunction with non linear load. Indirect current control scheme based on hysteresis controller has been used for controlling of active filter. The SAPF eliminates higher order harmonics while most dominant lower order harmonics are filtered out using passive filter. In this paper the performance of wind driven DFIG feeding non linear load with HAPF is analyzed for steady state and dynamic conditions, using MATLAB/Simulink.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 573-576
Performance Evaluation of Hybrid Active Power Filter
Hybrid active power filter are used for eliminating harmonics in the power system. This paper deals with the hybrid active power filter for non-linear load along with its control scheme. In a hybrid active power filter, the active part is used to filter out the higher order harmonics, while lower order harmonics are eliminated by passive filter tuned for 5th and 7th order harmonic frequencies. The combination of shunt active and shunt passive filter considerably reduces the cost and size of active power filter at the same time problem of passive filters are overcome. The effectiveness of proposed filter topology have been verified by MATLAB/Simulink.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 573-576
Performance Evaluation of Hybrid Active Power Filter
Hybrid active power filter are used for eliminating harmonics in the power system. This paper deals with the hybrid active power filter for non-linear load along with its control scheme. In a hybrid active power filter, the active part is used to filter out the higher order harmonics, while lower order harmonics are eliminated by passive filter tuned for 5th and 7th order harmonic frequencies. The combination of shunt active and shunt passive filter considerably reduces the cost and size of active power filter at the same time problem of passive filters are overcome. The effectiveness of proposed filter topology have been verified by MATLAB/Simulink.