Pan Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pan Hu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Zhi‐Ming Tu
Department of Spine Surgery, The Second Xiangya Hospital of Central South University, Changsha, China
2 shared publications - Bing Wang
Department of Spine Surgery, The Second Xiangya Hospital of Central South University, Changsha 410011, China
1 shared publication - Deng‐Xing Lun
Department of Spinal Surgery, Weifang People’s Hospital, Shandong Second Medical University, Weifang, China
1 shared publication Filippos Kontos
Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
1 shared publicationGuo‐Hua Lv
Department of Spine Surgery, The Second Xiangya Hospital of Central South University, Changsha, China
1 shared publication- Huizhi Wang
VCU Philips Institute for Oral Health Research, Department of Oral and Craniofacial Molecular Biology, Virginia Commonwealth University, Richmond, VA 23298, USA
1 shared publication
Latest Publications
- Open Access
- 21 December 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (1) , 295-303
Effect of Particle Size Ratios on the Physical and Chemical Properties of Surgical‐Grade Calcium Sulfate Hemihydrate
Objectives: To analyze the optimum particle size or formula ratio of surgical‐grade calcium sulfate (CS) for appropriate compressive strength, setting time, and vitro degradation rate.Methods: Three types of calcium sulfate hemihydrate (CSH) particles with diameters of 0–37.5 μm, 37.5–75 μm, and >75 μm were screened. Based on formulation ratio of different particles, this topic is divided into 10 groups by the unconstrained third‐order simplex lattice mixing design scheme in formula design experiment. The optimum formulation ratio of particle diameter for compressive strength, solidification time, and degradation rate in vitro was analyzed.Results: When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm and >75 μm are 55.0%, 17.4%, and 27.6% respectively, the compressive strength of the test sample is the highest, which is 14.16 MPa. When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm, and >75 μm are 0.00%, 0.00%, and 100.00% respectively, the initial setting time of the sample is the longest, which is 410.0 s. When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm, and >75 μm are 0.00%, 0.00%, and 100.00% respectively, the final setting time of the sample is the largest, and the final setting time of the sample is 460.00 s. When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm, and >75 μm are 0.00%, 0.00%, and 100.00% respectively, the degradation rate of the sample in vitro is the slowest, which is 18.8%.Conclusion: The morphological structure of surgical‐grade CS can affect compressive strength, setting time, and in vitro degradation rate. Surgical CS should be prepared based on different uses.
- 21 December 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (1) , 295-303
Open AccessEffect of Particle Size Ratios on the Physical and Chemical Properties of Surgical‐Grade Calcium Sulfate Hemihydrate
Objectives: To analyze the optimum particle size or formula ratio of surgical‐grade calcium sulfate (CS) for appropriate compressive strength, setting time, and vitro degradation rate.Methods: Three types of calcium sulfate hemihydrate (CSH) particles with diameters of 0–37.5 μm, 37.5–75 μm, and >75 μm were screened. Based on formulation ratio of different particles, this topic is divided into 10 groups by the unconstrained third‐order simplex lattice mixing design scheme in formula design experiment. The optimum formulation ratio of particle diameter for compressive strength, solidification time, and degradation rate in vitro was analyzed.Results: When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm and >75 μm are 55.0%, 17.4%, and 27.6% respectively, the compressive strength of the test sample is the highest, which is 14.16 MPa. When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm, and >75 μm are 0.00%, 0.00%, and 100.00% respectively, the initial setting time of the sample is the longest, which is 410.0 s. When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm, and >75 μm are 0.00%, 0.00%, and 100.00% respectively, the final setting time of the sample is the largest, and the final setting time of the sample is 460.00 s. When the percentage of the particle diameter of CS with 0–37.5 μm, 37.5–75 μm, and >75 μm are 0.00%, 0.00%, and 100.00% respectively, the degradation rate of the sample in vitro is the slowest, which is 18.8%.Conclusion: The morphological structure of surgical‐grade CS can affect compressive strength, setting time, and in vitro degradation rate. Surgical CS should be prepared based on different uses.
- Open Access
- 21 December 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (1) , 16-30
Long‐term Results Comparing Cervical Disc Arthroplasty to Anterior Cervical Discectomy and Fusion: A Systematic Review and Meta‐Analysis of Randomized Controlled Trials
Objective: Whether cervical disc arthroplasty (CDA) is superior to anterior cervical discectomy and fusion (ACDF) remains controversial, especially in relation to long‐term results. The present study aimed to evaluate the long‐term safety and efficiency of CDA and ACDF for cervical disc disease.Methods: We performed this study according to the Cochrane methodology. An extensive search was undertaken in PubMed, Embase, and Cochrane databases up to 1 June 2019 using the following key words: “anterior cervical fusion,” “arthroplasty,” “replacement” and “artificial disc”. RevMan 5.3 (Cochrane, London, UK) was used to analyze data. Safety and efficiency outcome measures included the success rate, functional outcome measures, adverse events (AE), adjacent segment degeneration (ASD), secondary surgery, and patients’ satisfaction and recommendation rates. The OR and MD with 95% confidence interval (CI) were used to evaluate discontinuous and continuous variables, respectively. The statistically significant level was set at P < 0.05.Results: A total of 11 randomized controlled trials with 3505 patients (CDA/ACDF: 1913/1592) were included in this meta‐analysis. Compared with ACDF, CDA achieved significantly higher overall success (2.10, 95% CI [1.70, 2.59]), neck disability index (NDI) success (1.73, 95% CI [1.37, 2.18]), neurological success (1.65, 95% CI [1.24, 2.20]), patients’ satisfaction (2.14, 95% CI [1.50, 3.05]), and patients’ recommendation rates (3.23, 95% CI [1.79, 5.80]). Functional outcome measures such as visual analog score neck pain (−5.50, 95% CI [−8.49, −2.52]) and arm pain (−3.78, 95% CI [−7.04, −0.53]), the Short Form‐36 physical component score (SF‐36 PCS) (1.93, 95% CI [0.53, 3.32]), and the Short Form‐36 mental component score (SF‐36 MCS) (2.62, 95% CI [0.95, 4.29]), revealed superiority in the CDA group. CDA also achieved a significantly lower rate of symptomatic ASD (0.46, 95% CI [0.34, 0.63]), total secondary surgery (0.50, 95% CI [0.29, 0.87]), secondary surgery at the index level (0.46, 95% CI [0.29, 0.74]), and secondary surgery at the adjacent level (0.37, 95% CI [0.28, 0.49]). However, no significant difference was found in radiological success (1.35, 95% CI [0.88, 2.08]), NDI score (−2.88, 95% CI [−5.93, 0.17]), total reported AE (1.14, 95% CI [0.92, 1.42]), serious AE (0.89, 95% CI [0.71, 1.11]), device/surgery‐related AE (0.90, 95% CI [0.68, 1.18]), radiological superior ASD (0.63, 95% CI [0.28, 1.43]), inferior ASD (0.45, 95% CI [0.19, 1.11]), and work status (1.33, 95% CI [0.78, 2.25]). Furthermore, subgroup analysis showed different results between US and non‐US groups.Conclusion: Our study provided further evidence that compared to ACDF, CDA had a higher long‐term clinical success rate and better functional outcome measurements, and resulted in less symptomatic ASD and fewer secondary surgeries. However, worldwide multicenter RCT with long‐term follow up are still needed for further evaluation in the future.
- 21 December 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (1) , 16-30
Open AccessLong‐term Results Comparing Cervical Disc Arthroplasty to Anterior Cervical Discectomy and Fusion: A Systematic Review and Meta‐Analysis of Randomized Controlled Trials
Objective: Whether cervical disc arthroplasty (CDA) is superior to anterior cervical discectomy and fusion (ACDF) remains controversial, especially in relation to long‐term results. The present study aimed to evaluate the long‐term safety and efficiency of CDA and ACDF for cervical disc disease.Methods: We performed this study according to the Cochrane methodology. An extensive search was undertaken in PubMed, Embase, and Cochrane databases up to 1 June 2019 using the following key words: “anterior cervical fusion,” “arthroplasty,” “replacement” and “artificial disc”. RevMan 5.3 (Cochrane, London, UK) was used to analyze data. Safety and efficiency outcome measures included the success rate, functional outcome measures, adverse events (AE), adjacent segment degeneration (ASD), secondary surgery, and patients’ satisfaction and recommendation rates. The OR and MD with 95% confidence interval (CI) were used to evaluate discontinuous and continuous variables, respectively. The statistically significant level was set at P < 0.05.Results: A total of 11 randomized controlled trials with 3505 patients (CDA/ACDF: 1913/1592) were included in this meta‐analysis. Compared with ACDF, CDA achieved significantly higher overall success (2.10, 95% CI [1.70, 2.59]), neck disability index (NDI) success (1.73, 95% CI [1.37, 2.18]), neurological success (1.65, 95% CI [1.24, 2.20]), patients’ satisfaction (2.14, 95% CI [1.50, 3.05]), and patients’ recommendation rates (3.23, 95% CI [1.79, 5.80]). Functional outcome measures such as visual analog score neck pain (−5.50, 95% CI [−8.49, −2.52]) and arm pain (−3.78, 95% CI [−7.04, −0.53]), the Short Form‐36 physical component score (SF‐36 PCS) (1.93, 95% CI [0.53, 3.32]), and the Short Form‐36 mental component score (SF‐36 MCS) (2.62, 95% CI [0.95, 4.29]), revealed superiority in the CDA group. CDA also achieved a significantly lower rate of symptomatic ASD (0.46, 95% CI [0.34, 0.63]), total secondary surgery (0.50, 95% CI [0.29, 0.87]), secondary surgery at the index level (0.46, 95% CI [0.29, 0.74]), and secondary surgery at the adjacent level (0.37, 95% CI [0.28, 0.49]). However, no significant difference was found in radiological success (1.35, 95% CI [0.88, 2.08]), NDI score (−2.88, 95% CI [−5.93, 0.17]), total reported AE (1.14, 95% CI [0.92, 1.42]), serious AE (0.89, 95% CI [0.71, 1.11]), device/surgery‐related AE (0.90, 95% CI [0.68, 1.18]), radiological superior ASD (0.63, 95% CI [0.28, 1.43]), inferior ASD (0.45, 95% CI [0.19, 1.11]), and work status (1.33, 95% CI [0.78, 2.25]). Furthermore, subgroup analysis showed different results between US and non‐US groups.Conclusion: Our study provided further evidence that compared to ACDF, CDA had a higher long‐term clinical success rate and better functional outcome measurements, and resulted in less symptomatic ASD and fewer secondary surgeries. However, worldwide multicenter RCT with long‐term follow up are still needed for further evaluation in the future.
- Open Access
- 21 March 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 11 (2) , 195-203
Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
Objective: To compare the biomechanical stability and compatibility of two iliosacral screws (ISS), a tension band plate (TBP), and a minimally invasive adjustable plate (MIAP) for treating Tile C pelvic fractures.Methods: Three groups of finite element models of the intact pelvis, including the main ligament and the proximal one‐third of both femurs, were developed to simulate vertical sacral fractures and treated with the three abovementioned internal fixation techniques. A 500 N vertical load, a 500 N vertical load plus a 10 Nm moment of forward sagittal direction, and 500 N vertical load plus a 10 Nm moment of right lateral direction were applied to the sacrum to simulate standing status, bending status, and flexion status, respectively. The maximum displacement value, the stress value, and the stress value of the fracture interface were compared among the three internal fixation techniques.Results: The results showed that all three internal fixation techniques effectively restored the biomechanical transmission of the injured pelvis. The stress on the implants in the TBP model was 167.47% and 53.41% higher than that in the ISS model and the MIAP model, respectively, and the stress shielding phenomenon of the TBP model was more obvious than in the other two models. Meanwhile, the stress between the fracture interfaces in the TBP fixation models was apparently higher than that in the other two models. However, the vertical displacement of the MIAP model was not significantly different from that in the ISS and TBP model; therefore, strong fixation could be obtained in all three models.Conclusion: Based on our results, we believe that the stability of Tile C pelvic fracture fixed with MIAP was similar to that of fractures fixed with ISS and TBP, but the stress shielding phenomenon and safety of implants in the TBP models were inferior to those in the MIAP and ISS fixation models. Meanwhile, MIAP and ISS fixation were more helpful to the healing processing than was TBP fixation, especially at the fracture interface of the second and third vertebral body levels.
- 21 March 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 11 (2) , 195-203
Open AccessBiomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
Objective: To compare the biomechanical stability and compatibility of two iliosacral screws (ISS), a tension band plate (TBP), and a minimally invasive adjustable plate (MIAP) for treating Tile C pelvic fractures.Methods: Three groups of finite element models of the intact pelvis, including the main ligament and the proximal one‐third of both femurs, were developed to simulate vertical sacral fractures and treated with the three abovementioned internal fixation techniques. A 500 N vertical load, a 500 N vertical load plus a 10 Nm moment of forward sagittal direction, and 500 N vertical load plus a 10 Nm moment of right lateral direction were applied to the sacrum to simulate standing status, bending status, and flexion status, respectively. The maximum displacement value, the stress value, and the stress value of the fracture interface were compared among the three internal fixation techniques.Results: The results showed that all three internal fixation techniques effectively restored the biomechanical transmission of the injured pelvis. The stress on the implants in the TBP model was 167.47% and 53.41% higher than that in the ISS model and the MIAP model, respectively, and the stress shielding phenomenon of the TBP model was more obvious than in the other two models. Meanwhile, the stress between the fracture interfaces in the TBP fixation models was apparently higher than that in the other two models. However, the vertical displacement of the MIAP model was not significantly different from that in the ISS and TBP model; therefore, strong fixation could be obtained in all three models.Conclusion: Based on our results, we believe that the stability of Tile C pelvic fracture fixed with MIAP was similar to that of fractures fixed with ISS and TBP, but the stress shielding phenomenon and safety of implants in the TBP models were inferior to those in the MIAP and ISS fixation models. Meanwhile, MIAP and ISS fixation were more helpful to the healing processing than was TBP fixation, especially at the fracture interface of the second and third vertebral body levels.