JPJim Parr

Jim Parr

*This is an algorithmically generated author record based on publicly available information.

Jim Parr has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Machine learning for detection of stenoses and aneurysms: application in a physiologically realistic virtual patient database

    by G. Jones, J. Parr, P. Nithiarasu, S. Pant

    This study presents an application of machine learning (ML) methods for detecting the presence of stenoses and aneurysms in the human arterial system. Four major forms of arterial disease—carotid artery stenosis (CAS), subclavian artery stenosis (SAS), peripheral arterial disease (PAD), and abdominal aortic aneurysms (AAA)—are considered. The ML methods are trained and tested on a physiologically realistic virtual patient database (VPD) containing 28,868 healthy subjects, adapted from the authors previous work and augmented to include disease. It is found that the tree-based methods of Random Forest and Gradient Boosting outperform other approaches. The performance of ML methods is quantified through the $$F_1$$F1 score and computation of sensitivities and specificities. When using six haemodynamic measurements (pressure in the common carotid, brachial, and radial arteries; and flow-rate in the common carotid, brachial, and femoral arteries), it is found that maximum $$F_1$$F1 scores larger than 0.9 are achieved for CAS and PAD, larger than 0.85 for SAS, and larger than 0.98 for both low- and high-severity AAAs. Corresponding sensitivities and specificities are larger than 90% for CAS and PAD, larger than 85% for SAS, and larger than 98% for both low- and high-severity AAAs. When reducing the number of measurements, performance is degraded by less than 5% when three measurements are used, and less than 10% when only two measurements are used for classification. For AAA, it is shown that $$F_1$$F1 scores larger than 0.85 and corresponding sensitivities and specificities larger than 85% are achievable when using only a single measurement. The results are encouraging to pursue AAA monitoring and screening through wearable devices which can reliably measure pressure or flow-rates.


  • Open Access

    The use of biotelemetry to explore disease progression markers in amyotrophic lateral sclerosis

    by Madeline Kelly, Arseniy Lavrov, Luis Garcia-Gancedo, Jim Parr, Robert Hart, Theresa Chiwera, Christopher E. Shaw, Ammar Al-Chalabi, Rachael Marsden, Martin R. Turner, et al.

    To explore novel, real-world biotelemetry disease progression markers in patients with amyotrophic lateral sclerosis (ALS) and to compare with clinical gold-standard measures. Methods: This was an exploratory, non-controlled, non-drug 2-phase study comprising a variable length Pilot Phase (n = 5) and a 48-week Core study Phase (n = 25; NCT02447952). Patients with mild or moderate ALS wore biotelemetry sensors for ∼3 days/month at home, measuring physical activity, heart rate variability (HRV), and speech over 48 weeks. These measures were assessed longitudinally in relation to ALS Functional Rating Scale-Revised (ALSFRS-R) score and forced vital capacity (FVC); assessed by telephone [monthly] and clinic visits [every 12 weeks]). Results: Pilot Phase data supported progression into the Core Phase, where a decline in physical activity from baseline followed ALS progression as measured by ALSFRS-R and FVC. Four endpoints showed moderate or strong between-patient correlations with ALSFRS-R total and gross motor domain scores (defined as a correlation coefficient of ≥0.5 or >0.7, respectively): average daytime active; percentage of daytime active; total daytime activity score; total 24-hour activity score. Moderate correlations were observed between speech endpoints and ALSFRS-R bulbar domain scores; HRV data quality was insufficient for reliable assessment. The sensor was generally well tolerated; 6/25 patients reported mostly mild or moderate intensity skin and subcutaneous tissue disorder adverse events. Conclusions: Biotelemetry measures of physical activity in this Pilot Study tracked ALS progression over time, highlighting their potential as endpoints for future clinical trials. A larger, formally powered study is required to further support activity endpoints as novel disease progression markers.


  • Open Access

    Objectively Monitoring Amyotrophic Lateral Sclerosis Patient Symptoms During Clinical Trials With Sensors: Observational Study

    by Luis Garcia-Gancedo, Madeline L Kelly, Arseniy Lavrov, Jim Parr, Rob Hart, Rachael Marsden, Martin R Turner, Kevin Talbot, Theresa Chiwera, Christopher E Shaw, et al.

    Background: Objective symptom monitoring of patients with Amyotrophic Lateral Sclerosis (ALS) has the potential to provide an important source of information to evaluate the impact of the disease on aspects of real-world functional capacity and activities of daily living in the home setting, providing useful objective outcome measures for clinical trials. Objective: This study aimed to investigate the feasibility of a novel digital platform for remote data collection of multiple symptoms—physical activity, heart rate variability (HRV), and digital speech characteristics—in 25 patients with ALS in an observational clinical trial setting to explore the impact of the devices on patients’ everyday life and to record tolerability related to the devices and study procedures over 48 weeks. Methods: In this exploratory, noncontrolled, nondrug study, patients attended a clinical site visit every 3 months to perform activity reference tasks while wearing a sensor, to conduct digital speech tests and for conventional ALS monitoring. In addition, patients wore the sensor in their daily life for approximately 3 days every month for the duration of the study. Results: The amount and quality of digital speech data captured at the clinical sites were as intended, and there were no significant issues. All the home monitoring sensor data available were propagated through the system and were received as expected. However, the amount and quality of physical activity home monitoring data were lower than anticipated. A total of 3 or more days (or partial days) of data were recorded for 65% of protocol time points, with no data collected for 24% of time points. At baseline, 24 of 25 patients provided data, reduced to 13 of 18 patients at Week 48. Lower-than-expected quality HRV data were obtained, likely because of poor contact between the sensor and the skin. In total, 6 of 25 patients had mild or moderate adverse events (AEs) in the skin and subcutaneous tissue disorders category because of skin irritation caused by the electrode patch. There were no reports of serious AEs or deaths. Most patients found the sensor comfortable, with no or minimal impact on daily activities. Conclusions: The platform can measure physical activity in patients with ALS in their home environment; patients used the equipment successfully, and it was generally well tolerated. The quantity of home monitoring physical activity data was lower than expected, although it was sufficient to allow investigation of novel physical activity end points. Good-quality in-clinic speech data were successfully captured for analysis. Future studies using objective patient monitoring approaches, combined with the most current technological advances, may be useful to elucidate novel digital biomarkers of disease progression.


  • Open Access

    Objectively Monitoring Amyotrophic Lateral Sclerosis Patient Symptoms During Clinical Trials With Sensors: Observational Study (Preprint)

    by Luis Garcia-Gancedo, Madeline L Kelly, Arseniy Lavrov, Jim Parr, Rob Hart, Rachael Marsden, Martin R Turner, Kevin Talbot, Theresa Chiwera, Christopher E Shaw, et al.

    BACKGROUND Objective symptom monitoring of patients with Amyotrophic Lateral Sclerosis (ALS) has the potential to provide an important source of information to evaluate the impact of the disease on aspects of real-world functional capacity and activities of daily living in the home setting, providing useful objective outcome measures for clinical trials. OBJECTIVE This study aimed to investigate the feasibility of a novel digital platform for remote data collection of multiple symptoms—physical activity, heart rate variability (HRV), and digital speech characteristics—in 25 patients with ALS in an observational clinical trial setting to explore the impact of the devices on patients’ everyday life and to record tolerability related to the devices and study procedures over 48 weeks. METHODS In this exploratory, noncontrolled, nondrug study, patients attended a clinical site visit every 3 months to perform activity reference tasks while wearing a sensor, to conduct digital speech tests and for conventional ALS monitoring. In addition, patients wore the sensor in their daily life for approximately 3 days every month for the duration of the study. RESULTS The amount and quality of digital speech data captured at the clinical sites were as intended, and there were no significant issues. All the home monitoring sensor data available were propagated through the system and were received as expected. However, the amount and quality of physical activity home monitoring data were lower than anticipated. A total of 3 or more days (or partial days) of data were recorded for 65% of protocol time points, with no data collected for 24% of time points. At baseline, 24 of 25 patients provided data, reduced to 13 of 18 patients at Week 48. Lower-than-expected quality HRV data were obtained, likely because of poor contact between the sensor and the skin. In total, 6 of 25 patients had mild or moderate adverse events (AEs) in the skin and subcutaneous tissue disorders category because of skin irritation caused by the electrode patch. There were no reports of serious AEs or deaths. Most patients found the sensor comfortable, with no or minimal impact on daily activities. CONCLUSIONS The platform can measure physical activity in patients with ALS in their home environment; patients used the equipment successfully, and it was generally well tolerated. The quantity of home monitoring physical activity data was lower than expected, although it was sufficient to allow investigation of novel physical activity end points. Good-quality in-clinic speech data were successfully captured for analysis. Future studies using objective patient monitoring approaches, combined with the most current technological advances, may be useful to elucidate novel digital biomarkers of disease progression.