Sri Vikram Palagummi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sri Vikram Palagummi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Fuh-Gwo Yuan
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA
3 shared publications - Martin Y. M. Chiang
Biosystems and Biomaterials Division, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, United States
3 shared publications F. G. Yuan
North Carolina State Univ. (United States)
2 shared publicationsTaeseung Hong
Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, USA; Department of Materials Science and Engineering, Pukyong National University, Busan, Republic of Korea
2 shared publicationsCarlos Beauchamp
Materials Science and Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
1 shared publicationChang Kwon Moon
Department of Materials Science and Engineering, Pukyong National University, Busan, Republic of Korea
1 shared publication
Latest Publications
- 1 December 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (12) , 1772-1782
Thermal shrinkage reveals the feasibility of pulse-delay photocuring technique
- 1 December 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (12) , 1772-1782
Thermal shrinkage reveals the feasibility of pulse-delay photocuring technique
- 1 February 2020
- Published by Elsevier in Dental Materials
- Vol. 36 (2) , 310-319
Resin viscosity determines the condition for a valid exposure reciprocity law in dental composites
- 1 February 2020
- Published by Elsevier in Dental Materials
- Vol. 36 (2) , 310-319
Resin viscosity determines the condition for a valid exposure reciprocity law in dental composites
- 1 March 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (3) , 035102
Real-time synchronous measurement of curing characteristics and polymerization stress in bone cements with a cantilever-beam based instrument
An instrumentation capable of simultaneously determining degree of conversion (DC), polymerization stress (PS), and polymerization exotherm (PE) in real time was introduced to self-curing bone cements. This comprises the combination of an in situ high-speed near-infrared spectrometer, a cantilever-beam instrument with compliance-variable feature, and a microprobe thermocouple. Two polymethylmethacrylate-based commercial bone cements, containing essentially the same raw materials but differ in their viscosity for orthopedic applications, were used to demonstrate the applicability of the instrumentation. The results show that for both the cements studied the final DC was marginally different, the final PS was different at the low compliance, the peak of the PE was similar, and their polymerization rates were significantly different. Systematic variation of instrumental compliance for testing reveals differences in the characteristics of PS profiles of both the cements. This emphasizes the importance of instrumental compliance in obtaining an accurate understanding of PS evaluation. Finally, the key advantage for the simultaneous measurements is that these polymerization properties can be correlated directly, thus providing higher measurement confidence and enables a more in-depth understanding of the network formation process.
- 1 March 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (3) , 035102
Real-time synchronous measurement of curing characteristics and polymerization stress in bone cements with a cantilever-beam based instrument
An instrumentation capable of simultaneously determining degree of conversion (DC), polymerization stress (PS), and polymerization exotherm (PE) in real time was introduced to self-curing bone cements. This comprises the combination of an in situ high-speed near-infrared spectrometer, a cantilever-beam instrument with compliance-variable feature, and a microprobe thermocouple. Two polymethylmethacrylate-based commercial bone cements, containing essentially the same raw materials but differ in their viscosity for orthopedic applications, were used to demonstrate the applicability of the instrumentation. The results show that for both the cements studied the final DC was marginally different, the final PS was different at the low compliance, the peak of the PE was similar, and their polymerization rates were significantly different. Systematic variation of instrumental compliance for testing reveals differences in the characteristics of PS profiles of both the cements. This emphasizes the importance of instrumental compliance in obtaining an accurate understanding of PS evaluation. Finally, the key advantage for the simultaneous measurements is that these polymerization properties can be correlated directly, thus providing higher measurement confidence and enables a more in-depth understanding of the network formation process.
- 1 February 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (2) , 228-237
High performance dental resin composites with hydrolytically stable monomers
- 1 February 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (2) , 228-237
High performance dental resin composites with hydrolytically stable monomers
- 28 July 2016
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 28 (5) , 578-594
An enhanced performance of a horizontal diamagnetic levitation mechanism–based vibration energy harvester for low frequency applications
This article identifies and studies key parameters that characterize a horizontal diamagnetic levitation mechanism–based low frequency vibration energy harvester with the aim of enhancing performance metrics such as efficiency and volume figure of merit. The horizontal diamagnetic levitation mechanism comprises three permanent magnets and two diamagnetic plates. Two of the magnets, lifting magnets, are placed co-axially at a distance such that each attracts a centrally located magnet, floating magnet, to balance its weight. This floating magnet is flanked closely by two diamagnetic plates which stabilize the levitation in the axial direction. The influence of the geometry of the floating magnet, the lifting magnet, and the diamagnetic plate is parametrically studied to quantify their effects on the size, stability of the levitation mechanism, and the resonant frequency of the floating magnet. For vibration energy harvesting using the horizontal diamagnetic levitation mechanism, a coil geometry and eddy current damping are critically discussed. Based on the analysis, an efficient experimental system is setup which showed a softening frequency response with an average system efficiency of 25.8% and a volume figure of merit of 0.23% when excited at a root mean square acceleration of 0.0546 m/s2 and at a frequency of 1.9 Hz.
- 28 July 2016
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 28 (5) , 578-594
An enhanced performance of a horizontal diamagnetic levitation mechanism–based vibration energy harvester for low frequency applications
This article identifies and studies key parameters that characterize a horizontal diamagnetic levitation mechanism–based low frequency vibration energy harvester with the aim of enhancing performance metrics such as efficiency and volume figure of merit. The horizontal diamagnetic levitation mechanism comprises three permanent magnets and two diamagnetic plates. Two of the magnets, lifting magnets, are placed co-axially at a distance such that each attracts a centrally located magnet, floating magnet, to balance its weight. This floating magnet is flanked closely by two diamagnetic plates which stabilize the levitation in the axial direction. The influence of the geometry of the floating magnet, the lifting magnet, and the diamagnetic plate is parametrically studied to quantify their effects on the size, stability of the levitation mechanism, and the resonant frequency of the floating magnet. For vibration energy harvesting using the horizontal diamagnetic levitation mechanism, a coil geometry and eddy current damping are critically discussed. Based on the analysis, an efficient experimental system is setup which showed a softening frequency response with an average system efficiency of 25.8% and a volume figure of merit of 0.23% when excited at a root mean square acceleration of 0.0546 m/s2 and at a frequency of 1.9 Hz.
- 15 April 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9799, 97991
An efficient low frequency horizontal diamagnetic levitation mechanism based vibration energy harvester
This article identifies and studies key parameters that characterize a horizontal diamagnetic levitation (HDL) mechanism based low frequency vibration energy harvester with the aim of enhancing performance metrics such as efficiency and volume figure of merit (FoMv). The HDL mechanism comprises of three permanent magnets and two diamagnetic plates. Two of the magnets, aka lifting magnets, are placed co-axially at a distance such that each attract a centrally located magnet, aka floating magnet, to balance its weight. This floating magnet is flanked closely by two diamagnetic plates which stabilize the levitation in the axial direction. The influence of the geometry of the floating magnet, the lifting magnet and the diamagnetic plate are parametrically studied to quantify their effects on the size, stability of the levitation mechanism and the resonant frequency of the floating magnet. For vibration energy harvesting using the HDL mechanism, a coil geometry and eddy current damping are critically discussed. Based on the analysis, an efficient experimental system is setup which showed a softening frequency response with an average system efficiency of 25.8% and a FoMv of 0.23% when excited at a root mean square acceleration of 0.0546 m/s2 and at frequency of 1.9 Hz. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 15 April 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9799, 97991
An efficient low frequency horizontal diamagnetic levitation mechanism based vibration energy harvester
This article identifies and studies key parameters that characterize a horizontal diamagnetic levitation (HDL) mechanism based low frequency vibration energy harvester with the aim of enhancing performance metrics such as efficiency and volume figure of merit (FoMv). The HDL mechanism comprises of three permanent magnets and two diamagnetic plates. Two of the magnets, aka lifting magnets, are placed co-axially at a distance such that each attract a centrally located magnet, aka floating magnet, to balance its weight. This floating magnet is flanked closely by two diamagnetic plates which stabilize the levitation in the axial direction. The influence of the geometry of the floating magnet, the lifting magnet and the diamagnetic plate are parametrically studied to quantify their effects on the size, stability of the levitation mechanism and the resonant frequency of the floating magnet. For vibration energy harvesting using the HDL mechanism, a coil geometry and eddy current damping are critically discussed. Based on the analysis, an efficient experimental system is setup which showed a softening frequency response with an average system efficiency of 25.8% and a FoMv of 0.23% when excited at a root mean square acceleration of 0.0546 m/s2 and at frequency of 1.9 Hz. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 1 January 2016
- Published by Elsevier
- p. 213-251
Magnetic levitation and its application for low frequency vibration energy harvesting
- 1 January 2016
- Published by Elsevier
- p. 213-251
Magnetic levitation and its application for low frequency vibration energy harvesting
- 1 December 2015
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 137 (6) , 061004
A Horizontal Diamagnetic Levitation Based Low Frequency Vibration Energy Harvester
This paper investigates a horizontal diamagnetic levitation (HDL) system for vibration energy harvesting in contrast to the vertical diamagnetic levitation (VDL) system recently proposed by Wang et al. (2013, “A Magnetically Levitated Vibration Energy Harvester,” Smart Mater. Struct., 22(5), p. 055016). In this configuration, two large magnets, alias lifting magnets (LMs), are arranged co-axially at a distance such that in between them a magnet, alias floating magnet (FM), is passively levitated at a laterally offset equilibrium position. The levitation is stabilized in the horizontal direction by two diamagnetic plates (DPs) made of pyrolytic graphite placed on each side of the FM. This HDL configuration mitigates the limitation on the amplitude of the FM imposed in the VDL configuration and exploits the ability to tailor the geometry to meet specific applications due to its frequency tuning capability. A simple circular coil geometry is designed to replace a portion of the pyrolytic graphite plate without sacrificing the stability of the levitation for transduction. An experimental setup exhibits a weak softening frequency response and validates the theoretical findings; at an input root mean square (RMS) acceleration of 0.0434 m/s2 and at a resonant frequency of 1.2 Hz, the prototype generated a RMS power of 3.6 μW with an average system efficiency of 1.93%.
- 1 December 2015
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 137 (6) , 061004
A Horizontal Diamagnetic Levitation Based Low Frequency Vibration Energy Harvester
This paper investigates a horizontal diamagnetic levitation (HDL) system for vibration energy harvesting in contrast to the vertical diamagnetic levitation (VDL) system recently proposed by Wang et al. (2013, “A Magnetically Levitated Vibration Energy Harvester,” Smart Mater. Struct., 22(5), p. 055016). In this configuration, two large magnets, alias lifting magnets (LMs), are arranged co-axially at a distance such that in between them a magnet, alias floating magnet (FM), is passively levitated at a laterally offset equilibrium position. The levitation is stabilized in the horizontal direction by two diamagnetic plates (DPs) made of pyrolytic graphite placed on each side of the FM. This HDL configuration mitigates the limitation on the amplitude of the FM imposed in the VDL configuration and exploits the ability to tailor the geometry to meet specific applications due to its frequency tuning capability. A simple circular coil geometry is designed to replace a portion of the pyrolytic graphite plate without sacrificing the stability of the levitation for transduction. An experimental setup exhibits a weak softening frequency response and validates the theoretical findings; at an input root mean square (RMS) acceleration of 0.0434 m/s2 and at a resonant frequency of 1.2 Hz, the prototype generated a RMS power of 3.6 μW with an average system efficiency of 1.93%.
- 2 April 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9431, 94310Q
A diamagnetically stabilized horizontally levitated electromagnetic vibration energy harvester
This article investigates a horizontal diamagnetic levitation (HDL) system for vibration energy harvesting. In this configuration, two large magnets, alias lifting magnets, are arranged co-axially at a distance such that in between them a magnet, alias floating magnet, is passively levitated at a laterally offset equilibrium position. The levitation is stabilized in the horizontal direction by two diamagnetic plates made of pyrolytic graphite placed on each side of the floating magnet. This HDL configuration permits large amplitude vibration of the floating magnet and exploits the ability to tailor the geometry to meet specific applications due to its frequency tuning capability. Theoretical modeling techniques are discussed followed by an experimental setup to validate it. At an input root mean square (RMS) acceleration of 0.0434 m/s2 (0.0044 grms) and at a resonant frequency of 1.2 Hz, the prototype generated a RMS power of 3.6 μW with an average system efficiency of 1.93%. Followed by the validation, parametric studies on the geometry of the components are undertaken to show that with the optimized parameters the efficiency can be further enhanced.
- 2 April 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9431, 94310Q
A diamagnetically stabilized horizontally levitated electromagnetic vibration energy harvester
This article investigates a horizontal diamagnetic levitation (HDL) system for vibration energy harvesting. In this configuration, two large magnets, alias lifting magnets, are arranged co-axially at a distance such that in between them a magnet, alias floating magnet, is passively levitated at a laterally offset equilibrium position. The levitation is stabilized in the horizontal direction by two diamagnetic plates made of pyrolytic graphite placed on each side of the floating magnet. This HDL configuration permits large amplitude vibration of the floating magnet and exploits the ability to tailor the geometry to meet specific applications due to its frequency tuning capability. Theoretical modeling techniques are discussed followed by an experimental setup to validate it. At an input root mean square (RMS) acceleration of 0.0434 m/s2 (0.0044 grms) and at a resonant frequency of 1.2 Hz, the prototype generated a RMS power of 3.6 μW with an average system efficiency of 1.93%. Followed by the validation, parametric studies on the geometry of the components are undertaken to show that with the optimized parameters the efficiency can be further enhanced.
- 1 April 2015
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 342, 330-345
An optimal design of a mono-stable vertical diamagnetic levitation based electromagnetic vibration energy harvester
- 1 April 2015
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 342, 330-345
An optimal design of a mono-stable vertical diamagnetic levitation based electromagnetic vibration energy harvester