Sibtain Ahmed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sibtain Ahmed has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Lena Jafri
Section of Chemical Pathology, Department of Pathology and Laboratory Medicine, Aga Khan University, Karachi, Pakistan
15 shared publications - Aysha Habib Khan
Section of Chemical Pathology, Department of Pathology and Laboratory Medicine, Aga Khan University, Karachi, Pakistan
13 shared publications - Hafsa Majid
Department of Pathology and Laboratory Medicine, The Aga Khan University Hospital, Stadium Road, Karachi 74800, Pakistan
11 shared publications Imran Siddiqui
Department of Pathology and Laboratory Medicine, Aga Khan University, Karachi, Pakistan
8 shared publications- Imran Siddiqui
Section of Chemical Pathology, Department of Pathology and Laboratory Medicine, Aga Khan University, Karachi, Pakistan
7 shared publications Aysha Habib Khan
Aga Khan Univ Hosp, Dept Pathol & Lab Med, Karachi, Pakistan
4 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 12 (4) , 95
Performance Evaluation of Newborn Screening for Congenital Adrenal Hyperplasia: A Single Health System Clinical Audit in Pakistan
Congenital adrenal hyperplasia (CAH) is an autosomal recessive disorder most commonly caused by 21-hydroxylase deficiency and can lead to life-threatening adrenal crises in infancy if not detected early. In Pakistan, the true incidence of CAH remains unknown due to the absence of national newborn screening programs. This study evaluated the effectiveness of a CAH newborn screening program introduced in 2021 at tertiary and secondary care centers in Pakistan. A retrospective cohort analysis included newborns screened between January 2021 and August 2025 using dried blood spot (DBS) 17-hydroxyprogesterone (17-OHP) testing. During the study period, 39,729 live births occurred, of which 34,621 newborns (87.1%) underwent screening. A total of 189 infants (0.55%) screened positive. Five infants were confirmed to have salt-wasting CAH; three, identified through population-based screening alone, yielded an incidence of 7.6 per 100,000 live births. The positive predictive value was 2.65%, reflecting a high false-positive rate, particularly among premature infants, while no false-negative cases were identified during the available follow-up period. This study demonstrates the feasibility of CAH newborn screening in a resource-limited setting and provides the first incidence estimates from a Pakistani hospital cohort.
- 4 November 2026
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 12 (4) , 95
Open AccessPerformance Evaluation of Newborn Screening for Congenital Adrenal Hyperplasia: A Single Health System Clinical Audit in Pakistan
Congenital adrenal hyperplasia (CAH) is an autosomal recessive disorder most commonly caused by 21-hydroxylase deficiency and can lead to life-threatening adrenal crises in infancy if not detected early. In Pakistan, the true incidence of CAH remains unknown due to the absence of national newborn screening programs. This study evaluated the effectiveness of a CAH newborn screening program introduced in 2021 at tertiary and secondary care centers in Pakistan. A retrospective cohort analysis included newborns screened between January 2021 and August 2025 using dried blood spot (DBS) 17-hydroxyprogesterone (17-OHP) testing. During the study period, 39,729 live births occurred, of which 34,621 newborns (87.1%) underwent screening. A total of 189 infants (0.55%) screened positive. Five infants were confirmed to have salt-wasting CAH; three, identified through population-based screening alone, yielded an incidence of 7.6 per 100,000 live births. The positive predictive value was 2.65%, reflecting a high false-positive rate, particularly among premature infants, while no false-negative cases were identified during the available follow-up period. This study demonstrates the feasibility of CAH newborn screening in a resource-limited setting and provides the first incidence estimates from a Pakistani hospital cohort.
- Open Access
- 24 July 2026
- Published by Springer Nature in Orphanet Journal of Rare Diseases
- Vol. 21 (1)
Developing a rare disease registry for inherited metabolic disorders in Pakistan
Background: Inherited metabolic disorders (IMDs) underrecognized and underreported in Pakistan because of fragmented data systems, limited surveillance, and constrained diagnostic resources. We aimed to establish a continuous registry for IMDs to generate structured epidemiological, clinical, and biochemical data in a genetically heterogeneous population with high rates of consanguinity. Methods: A single-center rare disease registry for IMDs was developed at the Biochemical Genetics Laboratory, Aga Khan University Hospital, Pakistan, and implemented between 2024 and March 2026 using retrospective consolidation of cases from January 2013 onward, followed by prospective real-time data capture. Demographic, clinical, and biochemical data were collected through structured case report forms and linked laboratory records. Registry performance was monitored using predefined indicators, including case volume, number of diagnostic categories, and data quality assessed through three audit cycles, 12 staff training rounds, and source verification procedures. Results: The registry included 3,880 unique cases from January 2013 to March 2026 and documented 59 distinct IMDs across all four provinces of Pakistan. Parental consanguinity was reported in 66.5% of cases ( n = 2,584). The most frequently identified disorders were methylmalonic aciduria ( n = 555), biotinidase deficiency ( n = 287), and urea cycle disorders ( n = 218). The final data dictionary comprised 14 categories and 384 common data elements. Quality control measures, including 12 training rounds and periodic audits, improved data accuracy and completeness from 60% to 96% to enable successful registry integration. Piloting data collection tools achieved > 90% completeness in demographic and clinical fields. Conclusion: This first registry for IMDs in Pakistan provides a structured, quality-assured epidemiological resource for defining the burden and spectrum of these disorders. The registry establishes a foundation for improved diagnosis, service planning, policy development, and future multicenter rare disease research. Clinical trial number: Not applicable.
- 24 July 2026
- Published by Springer Nature in Orphanet Journal of Rare Diseases
- Vol. 21 (1)
Open AccessDeveloping a rare disease registry for inherited metabolic disorders in Pakistan
Background: Inherited metabolic disorders (IMDs) underrecognized and underreported in Pakistan because of fragmented data systems, limited surveillance, and constrained diagnostic resources. We aimed to establish a continuous registry for IMDs to generate structured epidemiological, clinical, and biochemical data in a genetically heterogeneous population with high rates of consanguinity. Methods: A single-center rare disease registry for IMDs was developed at the Biochemical Genetics Laboratory, Aga Khan University Hospital, Pakistan, and implemented between 2024 and March 2026 using retrospective consolidation of cases from January 2013 onward, followed by prospective real-time data capture. Demographic, clinical, and biochemical data were collected through structured case report forms and linked laboratory records. Registry performance was monitored using predefined indicators, including case volume, number of diagnostic categories, and data quality assessed through three audit cycles, 12 staff training rounds, and source verification procedures. Results: The registry included 3,880 unique cases from January 2013 to March 2026 and documented 59 distinct IMDs across all four provinces of Pakistan. Parental consanguinity was reported in 66.5% of cases ( n = 2,584). The most frequently identified disorders were methylmalonic aciduria ( n = 555), biotinidase deficiency ( n = 287), and urea cycle disorders ( n = 218). The final data dictionary comprised 14 categories and 384 common data elements. Quality control measures, including 12 training rounds and periodic audits, improved data accuracy and completeness from 60% to 96% to enable successful registry integration. Piloting data collection tools achieved > 90% completeness in demographic and clinical fields. Conclusion: This first registry for IMDs in Pakistan provides a structured, quality-assured epidemiological resource for defining the burden and spectrum of these disorders. The registry establishes a foundation for improved diagnosis, service planning, policy development, and future multicenter rare disease research. Clinical trial number: Not applicable.
- Open Access
- 2 February 2026
- Vol. 37 (1) , 5-8
Magnesium - The Silent Partner or the Next Vitamin D? Shifting Paradigm in Mineral Metabolism in Health and Disease
- 2 February 2026
- Vol. 37 (1) , 5-8
Open AccessMagnesium - The Silent Partner or the Next Vitamin D? Shifting Paradigm in Mineral Metabolism in Health and Disease
- 2 December 2025
- Published by Emerald Publishing in International Journal of Health Care Quality Assurance
- Vol. 39 (4) , 293-301
Enhancing accuracy in clinical laboratories: a study on error identification via delta check in high-volume settings
Purpose: Medical laboratories are integral to patient diagnosis, with approximately 70% of clinical decisions relying on laboratory results. Ensuring result accuracy requires robust quality assurance measures, including delta check alerts, which flag significant differences between consecutive test results within patients. This study aimed to assess the effectiveness of Delta Check alerts in identifying errors in mean corpuscular volume (MCV) within a high-volume tertiary care laboratory, thereby enhancing patient safety and diagnostic precision. Design/methodology/approach: A cross-sectional study was conducted at The Aga Khan University Hospital, Pakistan from January to March 2024. All inpatient complete blood count (CBC) samples were included. A delta check event was defined as a change in MCV exceeding 5 femtoliter (fL) within 24 h. These events were classified as valid or invalid based on clinical relevance, with valid errors further categorized into pre-analytical and analytical errors. Data were analyzed using Microsoft Excel 365, and categorical variables were reported as frequencies and percentages. Findings: Among 149,286 inpatient CBC samples analyzed, 1,779 (1.19%) MCV delta check alerts were generated. Of these, 1,694 (95.2%) were invalid, primarily due to blood transfusions (n = 1,013, 59.7%). The remaining 85 valid errors included wrong patient labeling (n = 64, 75.2%), sample dilution (n = 19, 22.3%) and insufficient sample volume (2, 2.3%). These findings highlight the utility of delta check alerts in identifying pre-analytical errors that could otherwise compromise result accuracy. Research limitations/implications: This study underscores the value of delta check alerts in identifying pre-analytical issues, especially mislabeling and sample dilution, thereby strengthening laboratory quality assurance. Although many alerts were invalid, often due to transfusions, optimizing threshold settings may enhance system efficiency. Incorporating automated delta check processes into routine operations could provide an additional layer of protection against unnoticed errors. Future studies should examine the potential of machine learning to boost error detection while reducing false positives, ultimately improving both laboratory efficiency and diagnostic precision. Practical implications: Implementing delta check alerts can enhance laboratory error detection, particularly in identifying pre-analytical issues such as mislabeling and sample dilution. Integrating automated alerts into routine workflows may improve result accuracy and reduce diagnostic errors. Social implications: By improving laboratory quality assurance, delta check alerts contribute to enhanced patient safety, reduced diagnostic delays and improved healthcare outcomes. Strengthening error detection mechanisms supports public trust in laboratory testing and promotes better clinical decision-making. Originality/value: This study provides valuable insights into the application of delta check alerts as an additional quality assurance measure in high-volume hematology laboratories. While most alerts were clinically explainable and deemed invalid, a small but significant proportion identified critical pre-analytical errors, underscoring the importance of delta checks in enhancing laboratory quality assurance. By integrating delta check alerts into routine practice, laboratories can improve error detection, minimize misdiagnosis and enhance overall patient safety.
- 2 December 2025
- Published by Emerald Publishing in International Journal of Health Care Quality Assurance
- Vol. 39 (4) , 293-301
Enhancing accuracy in clinical laboratories: a study on error identification via delta check in high-volume settings
Purpose: Medical laboratories are integral to patient diagnosis, with approximately 70% of clinical decisions relying on laboratory results. Ensuring result accuracy requires robust quality assurance measures, including delta check alerts, which flag significant differences between consecutive test results within patients. This study aimed to assess the effectiveness of Delta Check alerts in identifying errors in mean corpuscular volume (MCV) within a high-volume tertiary care laboratory, thereby enhancing patient safety and diagnostic precision. Design/methodology/approach: A cross-sectional study was conducted at The Aga Khan University Hospital, Pakistan from January to March 2024. All inpatient complete blood count (CBC) samples were included. A delta check event was defined as a change in MCV exceeding 5 femtoliter (fL) within 24 h. These events were classified as valid or invalid based on clinical relevance, with valid errors further categorized into pre-analytical and analytical errors. Data were analyzed using Microsoft Excel 365, and categorical variables were reported as frequencies and percentages. Findings: Among 149,286 inpatient CBC samples analyzed, 1,779 (1.19%) MCV delta check alerts were generated. Of these, 1,694 (95.2%) were invalid, primarily due to blood transfusions (n = 1,013, 59.7%). The remaining 85 valid errors included wrong patient labeling (n = 64, 75.2%), sample dilution (n = 19, 22.3%) and insufficient sample volume (2, 2.3%). These findings highlight the utility of delta check alerts in identifying pre-analytical errors that could otherwise compromise result accuracy. Research limitations/implications: This study underscores the value of delta check alerts in identifying pre-analytical issues, especially mislabeling and sample dilution, thereby strengthening laboratory quality assurance. Although many alerts were invalid, often due to transfusions, optimizing threshold settings may enhance system efficiency. Incorporating automated delta check processes into routine operations could provide an additional layer of protection against unnoticed errors. Future studies should examine the potential of machine learning to boost error detection while reducing false positives, ultimately improving both laboratory efficiency and diagnostic precision. Practical implications: Implementing delta check alerts can enhance laboratory error detection, particularly in identifying pre-analytical issues such as mislabeling and sample dilution. Integrating automated alerts into routine workflows may improve result accuracy and reduce diagnostic errors. Social implications: By improving laboratory quality assurance, delta check alerts contribute to enhanced patient safety, reduced diagnostic delays and improved healthcare outcomes. Strengthening error detection mechanisms supports public trust in laboratory testing and promotes better clinical decision-making. Originality/value: This study provides valuable insights into the application of delta check alerts as an additional quality assurance measure in high-volume hematology laboratories. While most alerts were clinically explainable and deemed invalid, a small but significant proportion identified critical pre-analytical errors, underscoring the importance of delta checks in enhancing laboratory quality assurance. By integrating delta check alerts into routine practice, laboratories can improve error detection, minimize misdiagnosis and enhance overall patient safety.
- Open Access
- 1 October 2025
- Vol. 36 (3) , 222-224
POCT in Cardiovascular Operating Room: A Game Changer?
- 1 October 2025
- Vol. 36 (3) , 222-224
Open AccessPOCT in Cardiovascular Operating Room: A Game Changer?
- Open Access
- 3 June 2025
- Vol. 36 (2) , 95-96
Gamification As a Learning Modality in Clinical Chemistry – Breaking the Glass Ceiling
- 3 June 2025
- Vol. 36 (2) , 95-96
Open AccessGamification As a Learning Modality in Clinical Chemistry – Breaking the Glass Ceiling
- Open Access
- 3 June 2025
- Vol. 36 (2) , 132-142
A National e-Survey of Adult Reference Intervals of Routine Chemistry Analytes Used by Laboratories Across Pakistan: A Step Towards Harmonization
To identify the variation of reference intervals, reporting units used for key blood chemistry parameters in laboratories across Pakistan and to understand the factors contributing to these discrepancies. A comprehensive e-questionnaire developed using google forms covering key blood chemistry parameters (Electrolytes, fasting glucose, glucose random urea, creatinine and lipid profile), reference intervals, reporting units, and laboratory practices was administered via email to the Pathologists. Frequency and percentages were calculated for each response and descriptive results were also evaluated. A total of 38 responses were received five responses were excluded due to incomplete forms. The responses from 33 laboratories revealed substantial variability in reference intervals (RIs) for routine blood chemistry parameters, underscoring a significant lack of standardization. 66.66% laboratories had not developed specific RIs, relying instead on manufacturer-provided RIs, with infrequent reviews or updates. Challenges were prevalent due to non-harmonized RIs, leading to patient and physician counseling issues. Primary obstacles included funding deficiencies and limited access to healthy samples. These findings emphasize the critical need for national regulatory guidelines to standardize RIs, thereby enhancing the reliability and accuracy of laboratory diagnostics in Pakistan.
- 3 June 2025
- Vol. 36 (2) , 132-142
Open AccessA National e-Survey of Adult Reference Intervals of Routine Chemistry Analytes Used by Laboratories Across Pakistan: A Step Towards Harmonization
To identify the variation of reference intervals, reporting units used for key blood chemistry parameters in laboratories across Pakistan and to understand the factors contributing to these discrepancies. A comprehensive e-questionnaire developed using google forms covering key blood chemistry parameters (Electrolytes, fasting glucose, glucose random urea, creatinine and lipid profile), reference intervals, reporting units, and laboratory practices was administered via email to the Pathologists. Frequency and percentages were calculated for each response and descriptive results were also evaluated. A total of 38 responses were received five responses were excluded due to incomplete forms. The responses from 33 laboratories revealed substantial variability in reference intervals (RIs) for routine blood chemistry parameters, underscoring a significant lack of standardization. 66.66% laboratories had not developed specific RIs, relying instead on manufacturer-provided RIs, with infrequent reviews or updates. Challenges were prevalent due to non-harmonized RIs, leading to patient and physician counseling issues. Primary obstacles included funding deficiencies and limited access to healthy samples. These findings emphasize the critical need for national regulatory guidelines to standardize RIs, thereby enhancing the reliability and accuracy of laboratory diagnostics in Pakistan.
- 1 April 2025
- Vol. 47 (1) , 31-62
Performance evaluation of estimated glomerular filtration rate (eGFR) equations in Asia: A systematic review.
Chronic kidney disease (CKD) poses a global public health challenge, necessitating accurate assessment of renal function for timely intervention. Glomerular filtration rate (GFR) is a crucial indicator, traditionally measured using creatinine-based equations. However, Cystatin C-based equations offer potential advantages. We aim to evaluate the performance of estimated GFR (eGFR) equations for accurate renal function assessment in diverse Asian populations. Following PRISMA guidelines, the systematic review covered studies from 1991 to 2023 across Asian populations, incorporating equations based on both creatinine and Cystatin C. Eligibility criteria included adults aged 18 or older, either healthy or with CKD. Data extraction included study details, population characteristics, disease conditions, and formulas used. Quality assessment was conducted using the QUADAS-2 tool. The study analysed 26 studies focusing on South Asia and 66 on East Asia. In South Asia, the CKD-Epi-Pak equation demonstrated superior accuracy, achieving high percentages of eGFR values within specified ranges of measured GFR (P15: 70.39%, P30: 89.35%) with minimal bias (-1.33). The traditional MDRD equation exhibited poor performance, registering the lowest agreement percentages (P15: 7.8%, P30: 25.4%, P50: 71.1%) and the highest bias (-26.13). In East Asia, the CKD-Epi-2021 formula displayed the best accuracy, with high percentages of eGFR values within specified ranges (P15: 65.4%, P30: 97.6%). The simplified MDRD formula showed suboptimal performance, indicating lower agreement percentages (P15: 15.46%, P50: 56.59%). Variations of the MDRD formula in Japan exhibited bias while modified Gates Method demonstrated inferior precision. CKD-Epi-Pak and CKD-Epi-2021 show potential suitability in South and East Asia, respectively. Future research should prioritise ethnicity-specific equation development to enhance accuracy and clinical utility in Asian populations.
- 1 April 2025
- Vol. 47 (1) , 31-62
Performance evaluation of estimated glomerular filtration rate (eGFR) equations in Asia: A systematic review.
Chronic kidney disease (CKD) poses a global public health challenge, necessitating accurate assessment of renal function for timely intervention. Glomerular filtration rate (GFR) is a crucial indicator, traditionally measured using creatinine-based equations. However, Cystatin C-based equations offer potential advantages. We aim to evaluate the performance of estimated GFR (eGFR) equations for accurate renal function assessment in diverse Asian populations. Following PRISMA guidelines, the systematic review covered studies from 1991 to 2023 across Asian populations, incorporating equations based on both creatinine and Cystatin C. Eligibility criteria included adults aged 18 or older, either healthy or with CKD. Data extraction included study details, population characteristics, disease conditions, and formulas used. Quality assessment was conducted using the QUADAS-2 tool. The study analysed 26 studies focusing on South Asia and 66 on East Asia. In South Asia, the CKD-Epi-Pak equation demonstrated superior accuracy, achieving high percentages of eGFR values within specified ranges of measured GFR (P15: 70.39%, P30: 89.35%) with minimal bias (-1.33). The traditional MDRD equation exhibited poor performance, registering the lowest agreement percentages (P15: 7.8%, P30: 25.4%, P50: 71.1%) and the highest bias (-26.13). In East Asia, the CKD-Epi-2021 formula displayed the best accuracy, with high percentages of eGFR values within specified ranges (P15: 65.4%, P30: 97.6%). The simplified MDRD formula showed suboptimal performance, indicating lower agreement percentages (P15: 15.46%, P50: 56.59%). Variations of the MDRD formula in Japan exhibited bias while modified Gates Method demonstrated inferior precision. CKD-Epi-Pak and CKD-Epi-2021 show potential suitability in South and East Asia, respectively. Future research should prioritise ethnicity-specific equation development to enhance accuracy and clinical utility in Asian populations.
- Open Access
- 30 December 2024
- Vol. 35 (4) , 285-293
Diagnostic Accuracy of Creatinine-Based Equations for eGFR Estimation in Pakistanis: Evaluation of the European Kidney Function Consortium Equation vs the CKD-EPI Pakistan Equation
Chronic Kidney Disease (CKD) is prevalent in Pakistan, necessitating accurate diagnostic methods. This study evaluates the CKD-EPI 2009, CKD-EPI 2021, CKD-EPI Pak, MDRD, and EKFC equations against creatinine clearance (CrCl) to determine their diagnostic accuracy for CKD in the Pakistani population. n a retrospective cross-sectional study, data from 2,310 participants aged 18-70 were analyzed at The Aga Khan University in Karachi. Serum creatinine (SCr) and CrCl were recorded, and eGFR was calculated using five equations. Statistical analyses compared eGFR equations with CrCl, assessing sensitivity, specificity, and predictive values. EPI-Pak exhibited the highest sensitivity (95.15%) and agreement (94.85%) followed by EPI-2009 and EPI-2021 which showed the closest agreement with CrCl. Bland-Altman plots also indicated that EPI-Pak had the best agreement with CrCl. EPI-Pak outperformed other equations in estimating eGFR for the Pakistani population, aligning with previous recommendations for South Asians. EKFC, although highly specific, was less effective overall. EPI-Pak is the most accurate equation for diagnosing CKD in the Pakistani population. Its clinical implementation could improve CKD diagnosis and patient outcomes. Future studies should further validate these findings with larger, diverse samples.
- 30 December 2024
- Vol. 35 (4) , 285-293
Open AccessDiagnostic Accuracy of Creatinine-Based Equations for eGFR Estimation in Pakistanis: Evaluation of the European Kidney Function Consortium Equation vs the CKD-EPI Pakistan Equation
Chronic Kidney Disease (CKD) is prevalent in Pakistan, necessitating accurate diagnostic methods. This study evaluates the CKD-EPI 2009, CKD-EPI 2021, CKD-EPI Pak, MDRD, and EKFC equations against creatinine clearance (CrCl) to determine their diagnostic accuracy for CKD in the Pakistani population. n a retrospective cross-sectional study, data from 2,310 participants aged 18-70 were analyzed at The Aga Khan University in Karachi. Serum creatinine (SCr) and CrCl were recorded, and eGFR was calculated using five equations. Statistical analyses compared eGFR equations with CrCl, assessing sensitivity, specificity, and predictive values. EPI-Pak exhibited the highest sensitivity (95.15%) and agreement (94.85%) followed by EPI-2009 and EPI-2021 which showed the closest agreement with CrCl. Bland-Altman plots also indicated that EPI-Pak had the best agreement with CrCl. EPI-Pak outperformed other equations in estimating eGFR for the Pakistani population, aligning with previous recommendations for South Asians. EKFC, although highly specific, was less effective overall. EPI-Pak is the most accurate equation for diagnosing CKD in the Pakistani population. Its clinical implementation could improve CKD diagnosis and patient outcomes. Future studies should further validate these findings with larger, diverse samples.
- Open Access
- 30 October 2024
- Vol. 35 (3) , 140-141
Point of Care Tests - The Future of Diagnostic Medicine
- 30 October 2024
- Vol. 35 (3) , 140-141
Open AccessPoint of Care Tests - The Future of Diagnostic Medicine