Muhammet Aydın
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Muhammet Aydın has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Elif Burcu Aydın
Tekirdag Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey
12 shared publications Mustafa Kemal Sezgintürk
Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale 17110, Turkey
10 shared publications- Mustafa Kemal Sezgintürk
Bioengineering Department, Faculty of Engineering, Canakkale Onsekiz Mart University, Canakkale, Turkey
6 shared publications Elif Burcu Aydin
Scientific and Technological Research Center, Namik Kemal University, Tekirdag,Turkey
4 shared publicationsElif Burcu Aydın
Tekirdağ Namık Kemal University, Scientific and Technological Research Center, Tekirdağ 59030, Turkey
3 shared publications- Abdulhadi Baykal
Physics Department Middle East Technical University 06531 Ankara Turkey
2 shared publications
Latest Publications
- 30 June 2026
- Published by Celal Bayar University Journal of Science in Celal Bayar Üniversitesi Fen Bilimleri Dergisi
- Vol. 22 (2) , 204-215
A Highly Selective Electrochemical Biosensor for Di-2-Ethylhexyl Phthalate Detection by Using Single-Use Conjugated Polymer Coated Electrode
This work reported a novel electrochemical biosensor based on indium tin oxide (ITO) modified with epoxy-substituted polythiophene (Poly(Thi-Epoxy)) polymer for sensitive detection of di-2-ethylhexyl phthalate (DEHP), the most extensively used phthalate. DEHP-specific aptamer was utilized as a biorecognition molecule and provided selective analysis of DEHP. Poly(Thi-Epoxy) polymer was coated on the disposable working electrode to form a stable surface with epoxy groups for immobilization of aptamer. Electrochemical techniques were used to follow the electrochemical behaviour of the biosensor. The applicability of the biosensor toward DEHP sensing was investigated by electrochemical impedance spectroscopy (EIS) measurements, and the concentration of DEHP was measured through the increase in EIS signal change. Using this strategy, DEHP could be detected in the linear range of 0.5 to 300 pg/mL with a relatively low detection limit (LOD) of 0.144 pg/mL. Along with its exceptional sensitivity and selectivity, this biosensor demonstrated acceptable repeatability and reproducibility, long storage stability, and amazing reusability. The biosensor was successfully used to analyze DEHP in migrating water samples, indicating a promising practical application. In comparison to the gas chromatography (GC) method, the aptasensor that was created was ultimately effective in measuring DEHP. As a result, this strategy offered a promising method for developing a biosensor for the detection of phthalates.
- 30 June 2026
- Published by Celal Bayar University Journal of Science in Celal Bayar Üniversitesi Fen Bilimleri Dergisi
- Vol. 22 (2) , 204-215
A Highly Selective Electrochemical Biosensor for Di-2-Ethylhexyl Phthalate Detection by Using Single-Use Conjugated Polymer Coated Electrode
This work reported a novel electrochemical biosensor based on indium tin oxide (ITO) modified with epoxy-substituted polythiophene (Poly(Thi-Epoxy)) polymer for sensitive detection of di-2-ethylhexyl phthalate (DEHP), the most extensively used phthalate. DEHP-specific aptamer was utilized as a biorecognition molecule and provided selective analysis of DEHP. Poly(Thi-Epoxy) polymer was coated on the disposable working electrode to form a stable surface with epoxy groups for immobilization of aptamer. Electrochemical techniques were used to follow the electrochemical behaviour of the biosensor. The applicability of the biosensor toward DEHP sensing was investigated by electrochemical impedance spectroscopy (EIS) measurements, and the concentration of DEHP was measured through the increase in EIS signal change. Using this strategy, DEHP could be detected in the linear range of 0.5 to 300 pg/mL with a relatively low detection limit (LOD) of 0.144 pg/mL. Along with its exceptional sensitivity and selectivity, this biosensor demonstrated acceptable repeatability and reproducibility, long storage stability, and amazing reusability. The biosensor was successfully used to analyze DEHP in migrating water samples, indicating a promising practical application. In comparison to the gas chromatography (GC) method, the aptasensor that was created was ultimately effective in measuring DEHP. As a result, this strategy offered a promising method for developing a biosensor for the detection of phthalates.
- Open Access
- 1 July 2025
- Published by Hacettepe University in Hacettepe Journal of Biology and Chemistry
- Vol. 53 (3) , 29-42
A Highly Sensitive Electrochemical Immunosensor for the detection of CCR4 Biomarker with Star-Shaped Polymer Covered Disposable Electrode
An electrochemical immunosensor prepared with the use of star-shaped polymer (StrPol(GMA)) as a biosensor matrix material was manufactured to quantify the CC chemokine receptor 4 (CCR4) molecules in human serum. Various characterization techniques, including electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and scanning electron microscopy (SEM), were used for the analysis of the fabrication steps of the proposed system. The impedance and CV analyses at each modification step of the manufacturing process illustrated the charge transport kinetics of the ferri-ferro redox solution. The binding of anti-CCR4 antibody and the related antibody-its CCR4 antigen biointeraction on the working electrode surface changed the interfacial electron transport. The interactions of anti-CCR4 with different levels of CCR4 were further followed via variations in impedance responses. The results illustrated that the electron transport resistance rose linearly with rising amounts of CCR4 antigen. The dynamic range and detection limit (LOD) were determined as 0.115-23 pg/mL and 34.9 fg/mL, respectively. The specificity, regeneration, storage stability, and reproducibility tests were also performed. Furthermore, CCR4 detection in the presence of interfering biomarkers was accomplished with success using the biosensing approach. The results of these studies illustrate that the introduced biosensor was a useful tool for monitoring low concentrations of CCR4 in human sera.
- 1 July 2025
- Published by Hacettepe University in Hacettepe Journal of Biology and Chemistry
- Vol. 53 (3) , 29-42
Open AccessA Highly Sensitive Electrochemical Immunosensor for the detection of CCR4 Biomarker with Star-Shaped Polymer Covered Disposable Electrode
An electrochemical immunosensor prepared with the use of star-shaped polymer (StrPol(GMA)) as a biosensor matrix material was manufactured to quantify the CC chemokine receptor 4 (CCR4) molecules in human serum. Various characterization techniques, including electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and scanning electron microscopy (SEM), were used for the analysis of the fabrication steps of the proposed system. The impedance and CV analyses at each modification step of the manufacturing process illustrated the charge transport kinetics of the ferri-ferro redox solution. The binding of anti-CCR4 antibody and the related antibody-its CCR4 antigen biointeraction on the working electrode surface changed the interfacial electron transport. The interactions of anti-CCR4 with different levels of CCR4 were further followed via variations in impedance responses. The results illustrated that the electron transport resistance rose linearly with rising amounts of CCR4 antigen. The dynamic range and detection limit (LOD) were determined as 0.115-23 pg/mL and 34.9 fg/mL, respectively. The specificity, regeneration, storage stability, and reproducibility tests were also performed. Furthermore, CCR4 detection in the presence of interfering biomarkers was accomplished with success using the biosensing approach. The results of these studies illustrate that the introduced biosensor was a useful tool for monitoring low concentrations of CCR4 in human sera.
- Open Access
- 24 June 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (3) , 371-381
Determination of p53 biomarker with a smart electrochemical biosensor based on brush polymer-functionalized disposable electrode
A label-less impedimetric biosensor modified with poly(thiophene)-graft-poly(glycidyl methacrylate) polymer (PThi-g-PGM) was manufactured for p53 protein quantification in human serum samples. In this study, PThi-g-PGM polymer was synthesized, and this polymer matrix was coated using the spin-coating technique on the single-use indium tin oxide (ITO) substrate for anti-p53 antibody immobilization. The anti-p53 antibodies with high affinity for p53 proteins were covalently attached onto the PThi-g-PGM-coated electrode surface. In addition, the affinity of anti-p53 for the p53 protein was monitored at a constant frequency. Under optimized conditions, the impedimetric changes were linearly related to the p53 concentrations, ranging from 0.05 to 15 pg/mL with a low detection limit of 15.9 fg/mL. This biosensor had desirable storage stability, acceptable repeatability, and high reproducibility. Moreover, this impedimetric biosensor could be regenerated through an acidic treatment procedure. Additionally, the suggested biosensor successfully detected the p53 antigen in human serum samples, and good recycling rates (98.41%–109.32%) were found. In summary, the proposed immunosensor may be a powerful tool for the analysis of the p53 protein for early detection of cancer biomarkers.
- 24 June 2025
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 49 (3) , 371-381
Open AccessDetermination of p53 biomarker with a smart electrochemical biosensor based on brush polymer-functionalized disposable electrode
A label-less impedimetric biosensor modified with poly(thiophene)-graft-poly(glycidyl methacrylate) polymer (PThi-g-PGM) was manufactured for p53 protein quantification in human serum samples. In this study, PThi-g-PGM polymer was synthesized, and this polymer matrix was coated using the spin-coating technique on the single-use indium tin oxide (ITO) substrate for anti-p53 antibody immobilization. The anti-p53 antibodies with high affinity for p53 proteins were covalently attached onto the PThi-g-PGM-coated electrode surface. In addition, the affinity of anti-p53 for the p53 protein was monitored at a constant frequency. Under optimized conditions, the impedimetric changes were linearly related to the p53 concentrations, ranging from 0.05 to 15 pg/mL with a low detection limit of 15.9 fg/mL. This biosensor had desirable storage stability, acceptable repeatability, and high reproducibility. Moreover, this impedimetric biosensor could be regenerated through an acidic treatment procedure. Additionally, the suggested biosensor successfully detected the p53 antigen in human serum samples, and good recycling rates (98.41%–109.32%) were found. In summary, the proposed immunosensor may be a powerful tool for the analysis of the p53 protein for early detection of cancer biomarkers.
- 26 March 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (4) , 2567-2580
Carboxyethylsilanetriol-Coated Magnetic Nanoparticles as an Ultrasensitive Immunoplatform for Electrochemical Magnetosensing of Cotinine
In the present study, an innovative and simple electrochemical magneto biosensor based on carboxyethylsilanetriol-modified iron oxide (Fe3O4) magnetic nanoparticles was designed for ultrasensitive and specific analysis of cotinine, an important marker of smoking. Anticotinine antibodies were covalently immobilized on carboxylic acid-modified magnetic nanoparticles, and the cotinine-specific magnetic nanoparticles created a specific surface on the working electrode surface. The use of magnetic nanoparticles as an immobilization platform for antibodies provided a large surface area for antibody attachment and increased sensitivity. In addition, the advantages of the new immobilization platform were reusing the working electrode numerous times, recording repeatable and reproducible signals, and reducing the necessary volume of biomolecules. The specific interaction between cotinine and cotinine-specific antibody-attached magnetic nanoparticles restricted the electron transfer of the redox probe and changed the impedimetric response of the electrode correlated to the concentration of cotinine. The magneto biosensor had a wide detection range (2-300 pg/mL), a low LOD (606 fg/mL), and an acceptable recovery (97.24-105.31%) in real samples. In addition, the current biosensor's measurement results were in good agreement with those found by the standard liquid chromatography (HPLC) and enzyme-linked immunosorbent assay (ELISA) methods. These results showed that a simple impedimetric immunosensing platform was generated for the cotinine analysis.
- 26 March 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (4) , 2567-2580
Carboxyethylsilanetriol-Coated Magnetic Nanoparticles as an Ultrasensitive Immunoplatform for Electrochemical Magnetosensing of Cotinine
In the present study, an innovative and simple electrochemical magneto biosensor based on carboxyethylsilanetriol-modified iron oxide (Fe3O4) magnetic nanoparticles was designed for ultrasensitive and specific analysis of cotinine, an important marker of smoking. Anticotinine antibodies were covalently immobilized on carboxylic acid-modified magnetic nanoparticles, and the cotinine-specific magnetic nanoparticles created a specific surface on the working electrode surface. The use of magnetic nanoparticles as an immobilization platform for antibodies provided a large surface area for antibody attachment and increased sensitivity. In addition, the advantages of the new immobilization platform were reusing the working electrode numerous times, recording repeatable and reproducible signals, and reducing the necessary volume of biomolecules. The specific interaction between cotinine and cotinine-specific antibody-attached magnetic nanoparticles restricted the electron transfer of the redox probe and changed the impedimetric response of the electrode correlated to the concentration of cotinine. The magneto biosensor had a wide detection range (2-300 pg/mL), a low LOD (606 fg/mL), and an acceptable recovery (97.24-105.31%) in real samples. In addition, the current biosensor's measurement results were in good agreement with those found by the standard liquid chromatography (HPLC) and enzyme-linked immunosorbent assay (ELISA) methods. These results showed that a simple impedimetric immunosensing platform was generated for the cotinine analysis.
- 4 March 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (13) , 5769-5781
Functionalized magnetic nanoparticles for electrochemical magneto biosensing of PSMA cancer biomarker
A novel platform on which anti-prostate specific membrane antigen (PSMA) antibodies were immobilized on the core–shell structure of iron oxide (Fe3O4)/6-phosphonohexanoic acid (6Pha) nanoparticles was developed for the specific detection of PSMA.
- 4 March 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (13) , 5769-5781
Functionalized magnetic nanoparticles for electrochemical magneto biosensing of PSMA cancer biomarker
A novel platform on which anti-prostate specific membrane antigen (PSMA) antibodies were immobilized on the core–shell structure of iron oxide (Fe3O4)/6-phosphonohexanoic acid (6Pha) nanoparticles was developed for the specific detection of PSMA.
- 19 January 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (5) , 1632-1644
Ultrasensitive detection of NSE employing a novel electrochemical immunosensor based on a conjugated copolymer
In the current study a simple and highly specific label-free impedimetric neuron specific enolase (NSE) immunosensor based on a copolymer matrix-coated disposable electrode was designed and tested. The copolymer matrix was prepared using a very conductive EDOT monomer and semi-conductive thiophene-bearing epoxy groups (ThEp), and the combination of the two monomers enhanced the conductivity and protein loading capacity of the electrode surface. The P(ThEp-co-EDOT) copolymer matrix was prepared via a drop-casting process and anti-NSE recognition biomolecules were immobilized directly on the epoxy groups of the copolymer. After the coupling of NSE molecules on the P(ThEp-co-EDOT) copolymer matrix-coated electrode surface, the charge transfer resistance (Rct) of the biosensor changed dramatically. These changes in Rct were proportional to the NSE molecule amounts captured by anti-NSE molecules. Under optimized experimental conditions, the increment in the Rct value was proportional to the NSE concentration over a range of 0.01 to 25 pg mL−1 with a detection limit (LOD) of 2.98 × 10−3 pg mL−1. This copolymer-coated electrode provided a lower LOD than the other biosensors. In addition, the suggested electrochemical immuno-platform showed good selectivity, superior reproducibility, long-term stability, and high recovery of NSE in real serum (95.64–102.20%) and saliva (95.28–105.35%) samples. These results showed that the present system had great potential for electrochemical biosensing applications.
- 19 January 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (5) , 1632-1644
Ultrasensitive detection of NSE employing a novel electrochemical immunosensor based on a conjugated copolymer
In the current study a simple and highly specific label-free impedimetric neuron specific enolase (NSE) immunosensor based on a copolymer matrix-coated disposable electrode was designed and tested. The copolymer matrix was prepared using a very conductive EDOT monomer and semi-conductive thiophene-bearing epoxy groups (ThEp), and the combination of the two monomers enhanced the conductivity and protein loading capacity of the electrode surface. The P(ThEp-co-EDOT) copolymer matrix was prepared via a drop-casting process and anti-NSE recognition biomolecules were immobilized directly on the epoxy groups of the copolymer. After the coupling of NSE molecules on the P(ThEp-co-EDOT) copolymer matrix-coated electrode surface, the charge transfer resistance (Rct) of the biosensor changed dramatically. These changes in Rct were proportional to the NSE molecule amounts captured by anti-NSE molecules. Under optimized experimental conditions, the increment in the Rct value was proportional to the NSE concentration over a range of 0.01 to 25 pg mL−1 with a detection limit (LOD) of 2.98 × 10−3 pg mL−1. This copolymer-coated electrode provided a lower LOD than the other biosensors. In addition, the suggested electrochemical immuno-platform showed good selectivity, superior reproducibility, long-term stability, and high recovery of NSE in real serum (95.64–102.20%) and saliva (95.28–105.35%) samples. These results showed that the present system had great potential for electrochemical biosensing applications.
- 1 March 2021
- Published by Elsevier in Current Pharmaceutical Analysis
- Vol. 17 (3) , 450-459
A Label-free Electrochemical Immunosensor for Highly Sensitive Detection of TNF α, Based on Star Polymer-modified disposable ITO Electrode
Background: Biomarkers are very important disease-related biomolecules which should be analyzed sensitive and selective in related physiological fluids or tissues. Tumor necrosis factor-α is a type of cytokine which plays vitlly important roles in different methabolic pathways such as cell death, survival, differentiation, proliferation and migration, and infectious and inflammatory diseases including rheumatoid arthritis, diabetes. Objective: In this study, it was aimed to develop a reliable tool based on star-shaped poly(glycidyl methacrylate) polymer coated disposable indium tin oxide electrode for determination of Tumor necrosis factor-α, an important disease biomarker. Methods: Star shaped polymer was used as an interface material for anti- Tumor necrosis factor α antibodies immobilization. The antibodies were immobilized covalently onto polymer coated indium tin oxide electrode. Electrochemical impedance spectroscopy and cyclic voltammetry techniques were used for all electrochemical measurements. Results: The suggested immunosensor exhibited a linear range between 0.02 and 4 pg/mL Tumor necrosis factor-α, and the detection limit was found as 6 fg/mL. Scanning electron microscopy and atomic force microscopy were used for electrode surface characterization. In addition, the suggested immunosensor was used for Tumor necrosis factor-α sensing in human serum samples. The results displayed recoveries between 97.07 and 100.19%. Moreover, this immunosensor had a simple fabrication procedure and a long storage-stability. Conclusion: A new biosensor based on a Star shaped polymer for the ultra sensitive determination of a biomarker Tumor necrosis factor-α was developed. The biosensor presented excellent repeatability and reproducubility, and also wide calibration range for Tumor necrosis factor- α.
- 1 March 2021
- Published by Elsevier in Current Pharmaceutical Analysis
- Vol. 17 (3) , 450-459
A Label-free Electrochemical Immunosensor for Highly Sensitive Detection of TNF α, Based on Star Polymer-modified disposable ITO Electrode
Background: Biomarkers are very important disease-related biomolecules which should be analyzed sensitive and selective in related physiological fluids or tissues. Tumor necrosis factor-α is a type of cytokine which plays vitlly important roles in different methabolic pathways such as cell death, survival, differentiation, proliferation and migration, and infectious and inflammatory diseases including rheumatoid arthritis, diabetes. Objective: In this study, it was aimed to develop a reliable tool based on star-shaped poly(glycidyl methacrylate) polymer coated disposable indium tin oxide electrode for determination of Tumor necrosis factor-α, an important disease biomarker. Methods: Star shaped polymer was used as an interface material for anti- Tumor necrosis factor α antibodies immobilization. The antibodies were immobilized covalently onto polymer coated indium tin oxide electrode. Electrochemical impedance spectroscopy and cyclic voltammetry techniques were used for all electrochemical measurements. Results: The suggested immunosensor exhibited a linear range between 0.02 and 4 pg/mL Tumor necrosis factor-α, and the detection limit was found as 6 fg/mL. Scanning electron microscopy and atomic force microscopy were used for electrode surface characterization. In addition, the suggested immunosensor was used for Tumor necrosis factor-α sensing in human serum samples. The results displayed recoveries between 97.07 and 100.19%. Moreover, this immunosensor had a simple fabrication procedure and a long storage-stability. Conclusion: A new biosensor based on a Star shaped polymer for the ultra sensitive determination of a biomarker Tumor necrosis factor-α was developed. The biosensor presented excellent repeatability and reproducubility, and also wide calibration range for Tumor necrosis factor- α.
- 1 December 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 325, 128788
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker
- 1 December 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 325, 128788
Construction of succinimide group substituted polythiophene polymer functionalized sensing platform for ultrasensitive detection of KLK 4 cancer biomarker