Mauritius Hiller
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mauritius Hiller has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- K. G. Veinot
Y-12 National Security Complex, Box 2009, Oak Ridge, Tennessee, 37831-8245, UNITED STATES
2 shared publications N E Hertel
Georgia Institute of Technology, Atlanta, Georgia, 30332-0002, UNITED STATES
2 shared publicationsA. Ulanovsky
Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, 85764, Neuherberg, Germany
1 shared publication- Alexander Ulanowski
Terrestrial Environmental Radiochemistry Laboratory, Division of Physical and Chemical Sciences, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna, Austria
1 shared publication C. Woda
Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, 85764, Neuherberg, Germany
1 shared publicationClemens Woda
Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Medicine, Neuherberg, Germany
1 shared publication
Latest Publications
- 4 February 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (1) , 143-164
Influence of neutron cross-section resonances on organ/tissue equivalent and effective dose coefficients for the ICRP voxel phantoms
The materials which compose the ICRP Voxel phantoms used in the computation of conversion coefficients involve neutron interaction cross-sections that have resonances at specific energies. Depending on the energy bin structure used in the computations, these cross-section resonances may occur at energies that fall between energies at which dose coefficients are computed, thus their effects may not be completely accounted for in the reported coefficients. In the present study, a highly refined energy grid that closely follows the resonance structure in the phantom material cross-sections was identified and used to calculate dose coefficients. Both the equivalent organ/tissue doses for male and female voxel phantoms were computed as well as their summation to obtain the effective dose coefficients. The used refined energy grid tracks very closely the cross-sections in the vicinity of the resonances. The resulting refined energy grid coefficients are compared to coefficients for the coarser energy grid used in ICRP Publication 116. Additionally, reference spectra have been folded with both the fine and coarse sets of conversion coefficients. The resulting total effective doses for these reference spectra are used to assess the adequacy of the dose coefficients calculated on the original ICRP 116 energy grid. The dose coefficients were similarly computed for the local skin dose on the trunk of the body using the ICRU Report 95 phantom. The overall impact of the resonances on the organ/tissue equivalent dose, the effective dose, and the local skin dose are presented and discussed. In general, it was found that resonances can impact neutron dose coefficients, but in most cases the wide range of neutron energies encountered minimized this effect. The impact of resonances was further limited when computing effective dose due to organ/tissue summing and sex-averaging. For the neutron fields studied here, the impact was below 5%.
- 4 February 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (1) , 143-164
Influence of neutron cross-section resonances on organ/tissue equivalent and effective dose coefficients for the ICRP voxel phantoms
The materials which compose the ICRP Voxel phantoms used in the computation of conversion coefficients involve neutron interaction cross-sections that have resonances at specific energies. Depending on the energy bin structure used in the computations, these cross-section resonances may occur at energies that fall between energies at which dose coefficients are computed, thus their effects may not be completely accounted for in the reported coefficients. In the present study, a highly refined energy grid that closely follows the resonance structure in the phantom material cross-sections was identified and used to calculate dose coefficients. Both the equivalent organ/tissue doses for male and female voxel phantoms were computed as well as their summation to obtain the effective dose coefficients. The used refined energy grid tracks very closely the cross-sections in the vicinity of the resonances. The resulting refined energy grid coefficients are compared to coefficients for the coarser energy grid used in ICRP Publication 116. Additionally, reference spectra have been folded with both the fine and coarse sets of conversion coefficients. The resulting total effective doses for these reference spectra are used to assess the adequacy of the dose coefficients calculated on the original ICRP 116 energy grid. The dose coefficients were similarly computed for the local skin dose on the trunk of the body using the ICRU Report 95 phantom. The overall impact of the resonances on the organ/tissue equivalent dose, the effective dose, and the local skin dose are presented and discussed. In general, it was found that resonances can impact neutron dose coefficients, but in most cases the wide range of neutron energies encountered minimized this effect. The impact of resonances was further limited when computing effective dose due to organ/tissue summing and sex-averaging. For the neutron fields studied here, the impact was below 5%.
- 24 November 2021
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (1) , 87-109
External dose reconstruction at the shore of the Metlinsky Pond in the former village of Metlino (Techa River, Russia) based on environmental surveys, luminescence measurements and radiation transport modelling
The cohorts of people formerly living at the Techa River shoreline in the Southern Urals, Russia, are widely studied cohorts for the investigation of low-dose radiation effects to human health. The nuclear facilities of the Mayak Production Association (PA) discharged their radioactive effluents into the nearby Techa River, especially in the first years of operation. Health status of cohort member data is constantly being improved and updated. Consequently, there is a need to also improve and verify the underlying dosimetry, which gives information about the dose of cohort members. For the Techa River population, the dosimetry is handled in the Techa River Dosimetry System (TRDS). The present work shows results of a feasibility study to validate the TRDS at the location of the village of Metlino, a village just 7 km downstream from the Mayak PA. For this settlement there were two sources of external exposure, the contaminated banks of the Techa River and the contaminated shoreline of the nearby Metlinsky Pond. In the present study the north-western wall of a granary was used as a dose archive to validate dose estimates. Measurements of doses in brick accumulated over many decades and measurements of the current dose rate in bricks were combined with dose rate measurements in air above ground in front of the granary, historical contamination data and Monte-Carlo simulations. Air kerma estimates for 1949–1956 significantly different from zero could not be reconstructed for the Metlinsky Pond shoreline near the granary, but an upper dose limit could be estimated. Implications for TRDS-2016 are discussed.
- 24 November 2021
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (1) , 87-109
External dose reconstruction at the shore of the Metlinsky Pond in the former village of Metlino (Techa River, Russia) based on environmental surveys, luminescence measurements and radiation transport modelling
The cohorts of people formerly living at the Techa River shoreline in the Southern Urals, Russia, are widely studied cohorts for the investigation of low-dose radiation effects to human health. The nuclear facilities of the Mayak Production Association (PA) discharged their radioactive effluents into the nearby Techa River, especially in the first years of operation. Health status of cohort member data is constantly being improved and updated. Consequently, there is a need to also improve and verify the underlying dosimetry, which gives information about the dose of cohort members. For the Techa River population, the dosimetry is handled in the Techa River Dosimetry System (TRDS). The present work shows results of a feasibility study to validate the TRDS at the location of the village of Metlino, a village just 7 km downstream from the Mayak PA. For this settlement there were two sources of external exposure, the contaminated banks of the Techa River and the contaminated shoreline of the nearby Metlinsky Pond. In the present study the north-western wall of a granary was used as a dose archive to validate dose estimates. Measurements of doses in brick accumulated over many decades and measurements of the current dose rate in bricks were combined with dose rate measurements in air above ground in front of the granary, historical contamination data and Monte-Carlo simulations. Air kerma estimates for 1949–1956 significantly different from zero could not be reconstructed for the Metlinsky Pond shoreline near the granary, but an upper dose limit could be estimated. Implications for TRDS-2016 are discussed.
- 28 September 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , 628-653
Neutron dose coefficients for the lens of the eye
The International Commission on Radiation Units and Measurements (ICRU) Report Number 95 (2020 Operational quantities for external radiation exposure ICRU Rep. 95 J. ICRU 20 ) recommends new definitions ffor operational quantities as estimators of the International Commission on Radiological Protection radiation protection quantities. As part of this report, dose coefficients for neutron fluences are included for energies from 10 −9 –50 MeV. For lens of the eye dosimetry, several changes in the ICRU recommended quantities are of particular interest. First, an updated eye model is used that includes segmentation of the sensitive lens region. In addition, the use of absorbed dose instead of dose equivalent has been selected as the appropriate operational quantity since deterministic (i.e. non-stochastic) effects are of primary importance for the lens of the eye. The ICRU report also addresses computational parameters, such as absorbed dose tally volumes, depths, source areas and source rotational angles. In this work, neutron dose coefficients calculated for the lens of the eye in support of the ICRU report are presented. Dose coefficients for mono-energetic neutrons and reference neutron spectra are presented. The source is a parallel beam, and the mono-energetic dose coefficients are provided for rotational angles with respect to the front face of the head ranging from 0°–90°. In addition, monoenergetic dose coefficients for the parallel beam incident on the back of the head (180°) and for a rotational source geometry where the head is irradiated from all angles are reported. For all scenarios, absorbed doses to the complete lens and the sensitive volume of each eye were calculated. Eye lens absorbed dose coefficients, D p,slab (3,0)/Φ, were also calculated in an ICRU tissue slab phantom at a depth of 3 mm for a parallel beam irradiating the slab perpendicular to the front face, and these results are compared to the values determined using the eye phantom.
- 28 September 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , 628-653
Neutron dose coefficients for the lens of the eye
The International Commission on Radiation Units and Measurements (ICRU) Report Number 95 (2020 Operational quantities for external radiation exposure ICRU Rep. 95 J. ICRU 20 ) recommends new definitions ffor operational quantities as estimators of the International Commission on Radiological Protection radiation protection quantities. As part of this report, dose coefficients for neutron fluences are included for energies from 10 −9 –50 MeV. For lens of the eye dosimetry, several changes in the ICRU recommended quantities are of particular interest. First, an updated eye model is used that includes segmentation of the sensitive lens region. In addition, the use of absorbed dose instead of dose equivalent has been selected as the appropriate operational quantity since deterministic (i.e. non-stochastic) effects are of primary importance for the lens of the eye. The ICRU report also addresses computational parameters, such as absorbed dose tally volumes, depths, source areas and source rotational angles. In this work, neutron dose coefficients calculated for the lens of the eye in support of the ICRU report are presented. Dose coefficients for mono-energetic neutrons and reference neutron spectra are presented. The source is a parallel beam, and the mono-energetic dose coefficients are provided for rotational angles with respect to the front face of the head ranging from 0°–90°. In addition, monoenergetic dose coefficients for the parallel beam incident on the back of the head (180°) and for a rotational source geometry where the head is irradiated from all angles are reported. For all scenarios, absorbed doses to the complete lens and the sensitive volume of each eye were calculated. Eye lens absorbed dose coefficients, D p,slab (3,0)/Φ, were also calculated in an ICRU tissue slab phantom at a depth of 3 mm for a parallel beam irradiating the slab perpendicular to the front face, and these results are compared to the values determined using the eye phantom.
- 1 January 2021
- Published by Elsevier in Radiation Measurements
- Vol. 140
Absorbed doses in bricks and TL-dosimeters due to anthropogenic and natural environmental radiation sources
- 1 January 2021
- Published by Elsevier in Radiation Measurements
- Vol. 140
Absorbed doses in bricks and TL-dosimeters due to anthropogenic and natural environmental radiation sources
- 12 May 2020
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 40 (2) , 554-582
Neutron dose coefficients for local skin
A draft report by the International Commission on Radiation Units and Measurements (ICRU) Report Committee 26 (RC26) will recommend alternative definitions of the operational quantities that are better estimators of radiation protection quantities. Dose coefficients for use with physical field quantities—fluence and, for photons, air kerma—are given for various particle types over a broad energy range. For the skin dosimetry, several changes are of particular interest. Specifically, the use of absorbed dose instead of dose equivalent has been selected as the operational quantity since deterministic effects are of primary interest in the skin. In addition, newly recommended phantoms are specified for computing the operational dose coefficients. The report also addresses computational approaches such as tally volumes, depths, source areas, and rotational angles. In this work, dose coefficients calculated for local skin in support of the ICRU report are presented. Energy-dependent dose coefficients were calculated in phantoms specified for the trunk (slab), the ankle or wrist (pillar), and the finger (rod). The phantom specifications in this work were taken directly from the draft report. Full transport of secondary charged particles from neutron interactions was performed and an analysis of the depth-dose profiles in the slab phantom is presented, The last complete set of neutron dose coefficients for the extremities was published more than 25 years ago. Given the limited data available, it is difficult for many facilities to obtain clear guidance on how monitoring should be performed and how dosimeters should be calibrated so spectra from commonly encountered neutron sources were used to generate source-specific dose coefficients in each of the phantoms. Both energy-dependent and source-specific dose coefficients are provided for rotational angles up to 180 degrees for the rod and pillar phantoms and up to 75 degrees for the slab phantom.
- 12 May 2020
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 40 (2) , 554-582
Neutron dose coefficients for local skin
A draft report by the International Commission on Radiation Units and Measurements (ICRU) Report Committee 26 (RC26) will recommend alternative definitions of the operational quantities that are better estimators of radiation protection quantities. Dose coefficients for use with physical field quantities—fluence and, for photons, air kerma—are given for various particle types over a broad energy range. For the skin dosimetry, several changes are of particular interest. Specifically, the use of absorbed dose instead of dose equivalent has been selected as the operational quantity since deterministic effects are of primary interest in the skin. In addition, newly recommended phantoms are specified for computing the operational dose coefficients. The report also addresses computational approaches such as tally volumes, depths, source areas, and rotational angles. In this work, dose coefficients calculated for local skin in support of the ICRU report are presented. Energy-dependent dose coefficients were calculated in phantoms specified for the trunk (slab), the ankle or wrist (pillar), and the finger (rod). The phantom specifications in this work were taken directly from the draft report. Full transport of secondary charged particles from neutron interactions was performed and an analysis of the depth-dose profiles in the slab phantom is presented, The last complete set of neutron dose coefficients for the extremities was published more than 25 years ago. Given the limited data available, it is difficult for many facilities to obtain clear guidance on how monitoring should be performed and how dosimeters should be calibrated so spectra from commonly encountered neutron sources were used to generate source-specific dose coefficients in each of the phantoms. Both energy-dependent and source-specific dose coefficients are provided for rotational angles up to 180 degrees for the rod and pillar phantoms and up to 75 degrees for the slab phantom.
- 13 December 2019
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 40 (1) , 19-39
A biokinetic model for trivalent or hexavalent chromium in adult humans
Chromium exists in several oxidation states, with the trivalent state (Cr(III)) being the dominant naturally occurring form. Chromium in other oxidation states tends to be converted to the trivalent oxide in the natural environment and in biological systems. Chromium(III) has been shown to be an essential nutrient for humans and several non-human species. Chromium(VI), the second most stable form of chromium, is an important environmental contaminant that is mostly of industrial origin and is associated with lung cancer and nose tumours in chromium workers. This paper proposes a biokinetic model for chromium that addresses the distinctive behaviours of Cr(III) and Cr(VI) following uptake to blood of an adult human. The model is based on biokinetic data derived from relatively short-term studies involving administration of chromium tracers to adult human subjects or laboratory animals, supplemented with data on the long-term distribution of chromium in adult humans as estimated from autopsy measurements. The model is part of a comprehensive update of biokinetic models of the International Commission on Radiological Protection, used to project or evaluate radiation doses from occupational intake of radionuclides.
- 13 December 2019
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 40 (1) , 19-39
A biokinetic model for trivalent or hexavalent chromium in adult humans
Chromium exists in several oxidation states, with the trivalent state (Cr(III)) being the dominant naturally occurring form. Chromium in other oxidation states tends to be converted to the trivalent oxide in the natural environment and in biological systems. Chromium(III) has been shown to be an essential nutrient for humans and several non-human species. Chromium(VI), the second most stable form of chromium, is an important environmental contaminant that is mostly of industrial origin and is associated with lung cancer and nose tumours in chromium workers. This paper proposes a biokinetic model for chromium that addresses the distinctive behaviours of Cr(III) and Cr(VI) following uptake to blood of an adult human. The model is based on biokinetic data derived from relatively short-term studies involving administration of chromium tracers to adult human subjects or laboratory animals, supplemented with data on the long-term distribution of chromium in adult humans as estimated from autopsy measurements. The model is part of a comprehensive update of biokinetic models of the International Commission on Radiological Protection, used to project or evaluate radiation doses from occupational intake of radionuclides.
- 3 April 2017
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 56 (2) , 139-159
External dose reconstruction for the former village of Metlino (Techa River, Russia) based on environmental surveys, luminescence measurements, and radiation transport modelling
In the first years of its operation, the Mayak Production Association, a facility part of the Soviet nuclear weapons program in the Southern Urals, Russia, discharged large amounts of radioactively contaminated effluent into the nearby Techa River, thus exposing the people living at this river to external and internal radiations. The Techa River Cohort is a cohort intensely studied in epidemiology to investigate the correlation between low-dose radiation and health effects on humans. For the individuals in the cohort, the Techa River Dosimetry System describes the accumulated dose in human organs and tissues. In particular, organ doses from external exposure are derived from estimates of dose rate in air on the Techa River banks which were estimated from measurements and Monte Carlo modelling. Individual doses are calculated in accordance with historical records of individuals’ residence histories, observational data of typical lifestyles for different age groups, and age-dependent conversion factors from air kerma to organ dose. The work here describes an experimentally independent assessment of the key input parameter of the dosimetry system, the integral air kerma, for the former village of Metlino, upper Techa River region. The aim of this work was thus to validate the Techa River Dosimetry System for the location of Metlino in an independent approach. Dose reconstruction based on dose measurements in bricks from a church tower and Monte Carlo calculations was used to model the historic air kerma accumulated in the time from 1949 to 1956 at the shoreline of the Techa River in Metlino. Main issues are caused by a change in the landscape after the evacuation of the village in 1956. Based on measurements and published information and data, two separate models for the historic pre-evacuation geometry and for the current geometry of Metlino were created. Using both models, a value for the air kerma was reconstructed, which agrees with that obtained in the Techa River Dosimetry System within a factor of two.
- 3 April 2017
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 56 (2) , 139-159
External dose reconstruction for the former village of Metlino (Techa River, Russia) based on environmental surveys, luminescence measurements, and radiation transport modelling
In the first years of its operation, the Mayak Production Association, a facility part of the Soviet nuclear weapons program in the Southern Urals, Russia, discharged large amounts of radioactively contaminated effluent into the nearby Techa River, thus exposing the people living at this river to external and internal radiations. The Techa River Cohort is a cohort intensely studied in epidemiology to investigate the correlation between low-dose radiation and health effects on humans. For the individuals in the cohort, the Techa River Dosimetry System describes the accumulated dose in human organs and tissues. In particular, organ doses from external exposure are derived from estimates of dose rate in air on the Techa River banks which were estimated from measurements and Monte Carlo modelling. Individual doses are calculated in accordance with historical records of individuals’ residence histories, observational data of typical lifestyles for different age groups, and age-dependent conversion factors from air kerma to organ dose. The work here describes an experimentally independent assessment of the key input parameter of the dosimetry system, the integral air kerma, for the former village of Metlino, upper Techa River region. The aim of this work was thus to validate the Techa River Dosimetry System for the location of Metlino in an independent approach. Dose reconstruction based on dose measurements in bricks from a church tower and Monte Carlo calculations was used to model the historic air kerma accumulated in the time from 1949 to 1956 at the shoreline of the Techa River in Metlino. Main issues are caused by a change in the landscape after the evacuation of the village in 1956. Based on measurements and published information and data, two separate models for the historic pre-evacuation geometry and for the current geometry of Metlino were created. Using both models, a value for the air kerma was reconstructed, which agrees with that obtained in the Techa River Dosimetry System within a factor of two.