Jens Träger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jens Träger has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Norbert Hampp
Philipps Universität Marburg
7 shared publicationsHee-Cheol Kim
6 shared publicationsJasmin Heinzer
University of Marburg, Department of Chemistry, Hans‐Meerwein‐Straße, 35032 Marburg, Germany
3 shared publications- Bruno Scherb
University of Applied Sciences
1 shared publication - Claudia Hentschel
HTW Berlin, University of Applied Sciences
1 shared publication - Corinna Hägele
DMG Digital Enterprises SE, Hamburg, Germany
1 shared publication
Latest Publications
- 5 November 2026
- Published by Springer Nature
- p. 344-357
The Architecture of AgenTRIZ, a Multi-agent LLM Framework for TRIZ Automation
- 5 November 2026
- Published by Springer Nature
- p. 344-357
The Architecture of AgenTRIZ, a Multi-agent LLM Framework for TRIZ Automation
- 3 September 2023
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 9 (4) , 1015-1023
Relation of the working curve and exposure intensity in VPP 3D-printing
- 3 September 2023
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 9 (4) , 1015-1023
Relation of the working curve and exposure intensity in VPP 3D-printing
- 23 July 2009
- Published by Springer Nature
- p. 574-576
Coherently Controlled Release of Drugs in Ophthalmology
- 23 July 2009
- Published by Springer Nature
- p. 574-576
Coherently Controlled Release of Drugs in Ophthalmology
- 11 February 2008
- Published by Wiley in Macromolecular Bioscience
- Vol. 8 (2) , 177-183
Polymers for in vivo Tuning of Refractive Properties in Intraocular Lenses
High‐refractive‐index polymers for intraocular lenses are presented whose refractive index can be tuned post‐operatively in a non‐invasive manner to enable focal length and aspheric corrections in vivo. The polymer materials contain covalently attached photochemically crosslinkable coumarin side groups, to cause a change in refractive index of Δn > 0.02, which enables one to tune the focal length of a standard IOL by two diopters. This is enough to ensure that more than 80% of all cataract patients can be adjusted non‐invasively to optimal vision after cataract surgery, thus providing a remedy to a major shortcoming of today's cataract surgery. magnified image
- 11 February 2008
- Published by Wiley in Macromolecular Bioscience
- Vol. 8 (2) , 177-183
Polymers for in vivo Tuning of Refractive Properties in Intraocular Lenses
High‐refractive‐index polymers for intraocular lenses are presented whose refractive index can be tuned post‐operatively in a non‐invasive manner to enable focal length and aspheric corrections in vivo. The polymer materials contain covalently attached photochemically crosslinkable coumarin side groups, to cause a change in refractive index of Δn > 0.02, which enables one to tune the focal length of a standard IOL by two diopters. This is enough to ensure that more than 80% of all cataract patients can be adjusted non‐invasively to optimal vision after cataract surgery, thus providing a remedy to a major shortcoming of today's cataract surgery. magnified image
- 1 January 2008
- Published by Optica Publishing Group
- p. BTuF1
Novel Polymers for Intraocular Lenses Enabling Photo-induced Tuning of Focal Length
We have developed polymers where we can non-invasively induce a change in refractive index which is great enough to be interesting for the concept of in vivo tunable IOL’s by employing a photoinduced cycloaddition reaction.
- 1 January 2008
- Published by Optica Publishing Group
- p. BTuF1
Novel Polymers for Intraocular Lenses Enabling Photo-induced Tuning of Focal Length
We have developed polymers where we can non-invasively induce a change in refractive index which is great enough to be interesting for the concept of in vivo tunable IOL’s by employing a photoinduced cycloaddition reaction.
- 1 January 2008
- Published by Optica Publishing Group
- p. BTuC1
Novel Polymers for Intraocular Lenses Enabling Photo-triggered Drug Delivery
Posterior capsule opacification (PCO) is a common complication of cataract surgery. To address this problem we have developed drug delivery polymers allowing repeated drug release in a non-invasive and controlled manner.
- 1 January 2008
- Published by Optica Publishing Group
- p. BTuC1
Novel Polymers for Intraocular Lenses Enabling Photo-triggered Drug Delivery
Posterior capsule opacification (PCO) is a common complication of cataract surgery. To address this problem we have developed drug delivery polymers allowing repeated drug release in a non-invasive and controlled manner.
- 1 September 2007
- Published by Springer Nature in Nature Photonics
- Vol. 1 (9) , 509-511
Two-photon treatment
- 1 September 2007
- Published by Springer Nature in Nature Photonics
- Vol. 1 (9) , 509-511
Two-photon treatment
- 5 July 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6632, 66321F
Materials for intraocular lenses enabling photo-controlled tuning of focal length in vivo
Typical postoperative complications in cataract surgery are that refractive power and curvature of the implanted intraocular lens (IOL) do not have optimum values, requiring the patient to wear viewing aids. This is mainly because biometric data relevant for calculation of the IOL's shape cannot be determined with the required precision. Hence, there is a need for methods to tune the focal length postoperatively in a non-invasive manner. We have developed polymers where we can induce a change in refractive index by linking or cleaving bonds between a su.ciently large number of side groups of the polymer main chain in a photoinduced cycloaddition or cycloreversion reaction, respectively. These photoreactions lead to a change in refractive index great enough to be interesting for the concept of in vivo tunable IOL's. The photochemical reaction can be triggered by a two-photon process (TPA) using a pulsed laser system, i.e. the energy required for bond breaking is provided by two photons in the visible range. This is important because light in the UV cannot induce undesired changes of the refractive index owing to the strong UV-absorption of the cornea. Undesired changes due to light in the visible range of the spectrum are unlikely to happen because photon density of sun light is much too low for TPA. Due to the excellent spatial resolution that can be achieved with two-photon processes one cannot only modify the refractive index of the entire lens but also selectively in well defined areas enabling to correct for aberrations such as astigmatism. Here, we present new polymers that do not only exhibit a photo induced change of refractive index great enough to induce a change of focal length of more than two diopters in a standard IOL. These new polymers have also significantly improved material properties with respect to the fabrication of the IOL and the TPA-sensitivities and the light energy required to induce the refractive index change.
- 5 July 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6632, 66321F
Materials for intraocular lenses enabling photo-controlled tuning of focal length in vivo
Typical postoperative complications in cataract surgery are that refractive power and curvature of the implanted intraocular lens (IOL) do not have optimum values, requiring the patient to wear viewing aids. This is mainly because biometric data relevant for calculation of the IOL's shape cannot be determined with the required precision. Hence, there is a need for methods to tune the focal length postoperatively in a non-invasive manner. We have developed polymers where we can induce a change in refractive index by linking or cleaving bonds between a su.ciently large number of side groups of the polymer main chain in a photoinduced cycloaddition or cycloreversion reaction, respectively. These photoreactions lead to a change in refractive index great enough to be interesting for the concept of in vivo tunable IOL's. The photochemical reaction can be triggered by a two-photon process (TPA) using a pulsed laser system, i.e. the energy required for bond breaking is provided by two photons in the visible range. This is important because light in the UV cannot induce undesired changes of the refractive index owing to the strong UV-absorption of the cornea. Undesired changes due to light in the visible range of the spectrum are unlikely to happen because photon density of sun light is much too low for TPA. Due to the excellent spatial resolution that can be achieved with two-photon processes one cannot only modify the refractive index of the entire lens but also selectively in well defined areas enabling to correct for aberrations such as astigmatism. Here, we present new polymers that do not only exhibit a photo induced change of refractive index great enough to induce a change of focal length of more than two diopters in a standard IOL. These new polymers have also significantly improved material properties with respect to the fabrication of the IOL and the TPA-sensitivities and the light energy required to induce the refractive index change.
- 1 January 2007
- Published by Optica Publishing Group
- p. 6632_31
Materials for intraocular lenses enabling photo-controlled tuning of focal length in vivo
- 1 January 2007
- Published by Optica Publishing Group
- p. 6632_31
Materials for intraocular lenses enabling photo-controlled tuning of focal length in vivo