Adam Kotowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adam Kotowski has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Joanna Karpińska
Department of Analytical and Inorganic Chemistry, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K St., 15-245 Bialystok, Poland
2 shared publications - Urszula Kotowska
Department of Analytical and Inorganic Chemistry, University of Bialystok, 1K Ciołkowskiego Street, 15-328 Bialystok, Poland
2 shared publications - Adam Idzkowski
Faculty of Electrical Engineering, Bialystok University of Technology, PL-15351 Bialystok, Poland
1 shared publication - Adam Wolniakowski
Faculty of Electrical Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
1 shared publication Alicja Piotrowska-Niczyporuk
1 shared publication- Arkadiusz Mystkowski
Faculty of Electrical Engineering, Department of Automatic Control and Robotics, Bialystok University of Technology, Bialystok, Poland
1 shared publication
Latest Publications
- Open Access
Design and Evaluation of Low-Cost Vibration-Based Machine Monitoring System for Hay Rotary Tedder
Vibration monitoring provides a good-quality source of information about the health condition of machines, and it is often based on the use of accelerometers. This article focuses on the use of accelerometer sensors in fabricating a low-cost system for monitoring vibrations in agricultural machines, such as rotary tedders. The aim of the study is to provide useful data on equipment health for improving the durability of such machinery. The electronic prototype, based on the low-cost AVR microcontroller ATmega128 with 10-bit ADC performing a 12-bit measurement, is able to acquire data from an accelerometer weighing up to 10 g. Three sensors were exposed to low accelerations with the use of an exciter, and their static characteristics were presented. Standard experimental tests were used to evaluate the constructed machine monitoring system. The self-contained prototype system was calibrated in a laboratory test rig, and sinusoidal and multisinusoidal excitations were used. Measurements in time and frequency domains were carried out. The amplitude characteristic of the preformed system differed by no more than 15% within a frequency range of 10 Hz–10 kHz, compared to the AVM4000 commercial product. Finally, the system was experimentally tested to measure acceleration at three characteristic points in a rotational tedder, i.e., the solid grease gearbox, the drive shaft bearing and the main frame. The RMS amplitude values of the shaft vibrations on the bearing in relation to the change in the drive shaft speed of two tedders of the same type were evaluated and compared. Additionally, the parameters of kurtosis and crest factor were compared to ascertain the bearing condition.
Open AccessDesign and Evaluation of Low-Cost Vibration-Based Machine Monitoring System for Hay Rotary Tedder
Vibration monitoring provides a good-quality source of information about the health condition of machines, and it is often based on the use of accelerometers. This article focuses on the use of accelerometer sensors in fabricating a low-cost system for monitoring vibrations in agricultural machines, such as rotary tedders. The aim of the study is to provide useful data on equipment health for improving the durability of such machinery. The electronic prototype, based on the low-cost AVR microcontroller ATmega128 with 10-bit ADC performing a 12-bit measurement, is able to acquire data from an accelerometer weighing up to 10 g. Three sensors were exposed to low accelerations with the use of an exciter, and their static characteristics were presented. Standard experimental tests were used to evaluate the constructed machine monitoring system. The self-contained prototype system was calibrated in a laboratory test rig, and sinusoidal and multisinusoidal excitations were used. Measurements in time and frequency domains were carried out. The amplitude characteristic of the preformed system differed by no more than 15% within a frequency range of 10 Hz–10 kHz, compared to the AVM4000 commercial product. Finally, the system was experimentally tested to measure acceleration at three characteristic points in a rotational tedder, i.e., the solid grease gearbox, the drive shaft bearing and the main frame. The RMS amplitude values of the shaft vibrations on the bearing in relation to the change in the drive shaft speed of two tedders of the same type were evaluated and compared. Additionally, the parameters of kurtosis and crest factor were compared to ascertain the bearing condition.
- Open Access
- 1 August 2021
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 21 (4) , 93-98
A Method for Improving the Accuracy of Natural Frequency Measurement Using In-the-loop Computing
The method presented in the paper is based on in-the-loop computing applied for impulse response to obtain a spectrum with a much higher frequency resolution than using FFT. Then, higher spectrum frequency resolution results in greater accuracy in estimation of natural frequencies. The frequency resolution of estimated spectrum in this method is completely independent of the length of impulse response and, by extension, the method eliminates the problem of spectral resolution limitation using FFT due to finite length of recorded signals. This fact is very useful and is the main advantage of the proposed method. The results of the method have been shown and compared in quantitative terms to natural frequencies estimated using classical FFT with zero-padding as reference method.
- 1 August 2021
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 21 (4) , 93-98
Open AccessA Method for Improving the Accuracy of Natural Frequency Measurement Using In-the-loop Computing
The method presented in the paper is based on in-the-loop computing applied for impulse response to obtain a spectrum with a much higher frequency resolution than using FFT. Then, higher spectrum frequency resolution results in greater accuracy in estimation of natural frequencies. The frequency resolution of estimated spectrum in this method is completely independent of the length of impulse response and, by extension, the method eliminates the problem of spectral resolution limitation using FFT due to finite length of recorded signals. This fact is very useful and is the main advantage of the proposed method. The results of the method have been shown and compared in quantitative terms to natural frequencies estimated using classical FFT with zero-padding as reference method.
- Open Access
Rapid and Sensitive Analysis of Hormones and Other Emerging Contaminants in Groundwater Using Ultrasound-Assisted Emulsification Microextraction with Solidification of Floating Organic Droplet Followed by GC-MS Detection
Ultrasound-assisted emulsification microextraction with solidification of floating organic droplet (USAEME-SFOD) has been applied to isolate hormones and other emerging contaminants from groundwater samples. Simultaneously with the extraction process, derivatization in the matrix was carried out using acetic anhydride. Quantification of studied organic pollutants was done through gas chromatography mass spectrometry (GC-MS). Hormones included β-estradiol (E2), estrone (E1), and diethylstilbestrol (DES). Other compounds belonged to groups of pharmaceuticals (diclofenac (DIC)), antiseptics (triclosan (TRC)), preservatives (propylparaben (PP) and butylparaben (BP)), sunscreen agents (benzophenone (BPH), and 3-(4-methylbenzylidene)camphor (3MBC)), repellents (N,N-diethyltoluamide (DEET)), industrial chemicals (bisphenol A (BPA), 4-t-octylphenol (4OP), 4-n-nonylphenol (4NP)). A non-toxic and inexpensive 1-undecanol was successfully used as the extraction solvent. Volume of extractant and derivatization agent, ionic strength, and time of extraction were optimized. Very low limits of detection (LoD) ranging from 0.01 to 5.9 ng/L were obtained. Recoveries ranged from 90% to 123%, with relative standard deviation being lower than 17%. The developed procedure was used to determine target compounds in groundwater collected at municipal waste landfills as well as in groundwater from wells distant from sources of pollution.
Open AccessRapid and Sensitive Analysis of Hormones and Other Emerging Contaminants in Groundwater Using Ultrasound-Assisted Emulsification Microextraction with Solidification of Floating Organic Droplet Followed by GC-MS Detection
Ultrasound-assisted emulsification microextraction with solidification of floating organic droplet (USAEME-SFOD) has been applied to isolate hormones and other emerging contaminants from groundwater samples. Simultaneously with the extraction process, derivatization in the matrix was carried out using acetic anhydride. Quantification of studied organic pollutants was done through gas chromatography mass spectrometry (GC-MS). Hormones included β-estradiol (E2), estrone (E1), and diethylstilbestrol (DES). Other compounds belonged to groups of pharmaceuticals (diclofenac (DIC)), antiseptics (triclosan (TRC)), preservatives (propylparaben (PP) and butylparaben (BP)), sunscreen agents (benzophenone (BPH), and 3-(4-methylbenzylidene)camphor (3MBC)), repellents (N,N-diethyltoluamide (DEET)), industrial chemicals (bisphenol A (BPA), 4-t-octylphenol (4OP), 4-n-nonylphenol (4NP)). A non-toxic and inexpensive 1-undecanol was successfully used as the extraction solvent. Volume of extractant and derivatization agent, ionic strength, and time of extraction were optimized. Very low limits of detection (LoD) ranging from 0.01 to 5.9 ng/L were obtained. Recoveries ranged from 90% to 123%, with relative standard deviation being lower than 17%. The developed procedure was used to determine target compounds in groundwater collected at municipal waste landfills as well as in groundwater from wells distant from sources of pollution.
- 1 November 2018
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 120, 268-277
Removal of phthalates and other contaminants from municipal wastewater during cultivation of Wolffia arrhiza
- 1 November 2018
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 120, 268-277
Removal of phthalates and other contaminants from municipal wastewater during cultivation of Wolffia arrhiza
- Open Access
- 1 December 2014
- Published by Bialystok University of Technology in Acta Mechanica et Automatica
- Vol. 8 (4) , 219-222
Cross-Correlation-Based Method vs. Classical Fft for Spectral Analysis of Impulse Response
The paper presents comparison of results of impulse response spectral analysis that has been obtained using a method based on cross-correlation with results obtained using classical FFT. The presented non-Fourier method is achieved by correlating the analyzed signal and reference single-harmonic signals and using Hilbert transform to obtain an envelope of cross-correlation. The envelope of crosscorrelation makes it possible to calculate appropriate indicator and make its plot in frequency domain as a spectrum. The spectrum obtained this way has its advantage over the FFT that the spectral resolution does not depend on duration of signal. At the same time, the spectral resolution can be much greater than spectral resolution resultant from FFT. Obtained results show that presented non-Fourier method gives frequency readout more accurate in comparison to FFT when the impulse response is a short-time signal e.g. few dozen of miliseconds lasting.
- 1 December 2014
- Published by Bialystok University of Technology in Acta Mechanica et Automatica
- Vol. 8 (4) , 219-222
Open AccessCross-Correlation-Based Method vs. Classical Fft for Spectral Analysis of Impulse Response
The paper presents comparison of results of impulse response spectral analysis that has been obtained using a method based on cross-correlation with results obtained using classical FFT. The presented non-Fourier method is achieved by correlating the analyzed signal and reference single-harmonic signals and using Hilbert transform to obtain an envelope of cross-correlation. The envelope of crosscorrelation makes it possible to calculate appropriate indicator and make its plot in frequency domain as a spectrum. The spectrum obtained this way has its advantage over the FFT that the spectral resolution does not depend on duration of signal. At the same time, the spectral resolution can be much greater than spectral resolution resultant from FFT. Obtained results show that presented non-Fourier method gives frequency readout more accurate in comparison to FFT when the impulse response is a short-time signal e.g. few dozen of miliseconds lasting.
- 6 January 2009
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 147-149, 606-611
Parametric Description of Vibration Using the Autocorrelation Function
The paper presents the use of the autocorrelation function for the description of vibrations and the problems connected with. The proposed method is based on the analysis of vibration signal recorded for machine during its operations using an analytic form of the autocorrelation function. The parameters are obtained using a curve fitting procedure. To keep a quality of parametric representation of considered vibration, only the curve fitting causes a determination coefficient over 0.90 is taken into consideration. Therefore, the autocorrelation functions are submitted for the fast Fourier transform to be helped, in determination of number of the dominant harmonic components. Also, the analytic form and parameters of power spectral density has been also calculated. Finally, the set of parameters has been collected to describe the selected fragment of vibration of the simple rotating machine. The influence of duration of analyzed vibration on the parameters values is also examined in this work.
- 6 January 2009
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 147-149, 606-611
Parametric Description of Vibration Using the Autocorrelation Function
The paper presents the use of the autocorrelation function for the description of vibrations and the problems connected with. The proposed method is based on the analysis of vibration signal recorded for machine during its operations using an analytic form of the autocorrelation function. The parameters are obtained using a curve fitting procedure. To keep a quality of parametric representation of considered vibration, only the curve fitting causes a determination coefficient over 0.90 is taken into consideration. Therefore, the autocorrelation functions are submitted for the fast Fourier transform to be helped, in determination of number of the dominant harmonic components. Also, the analytic form and parameters of power spectral density has been also calculated. Finally, the set of parameters has been collected to describe the selected fragment of vibration of the simple rotating machine. The influence of duration of analyzed vibration on the parameters values is also examined in this work.
- 1 September 2008
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 144, 39-44
Analytic Description of Impulse Response Signals
The paper describes a method of analytic description of impulse response (IR) signals obtained during the test of technical object. The proposed description is based on the curve fitting to obtain the values of the parameters of analytic form of auto-correlation and power spectral density function. The impulse excitation is given into thoroughly described points of object and the proper fragment of IR is selected in the order to assure the accuracy of the curve fitting over the level of 90%. This approach enables to describe changes of IR signals in the form of percentage variations in the parameters of the auto-correlation and power spectral density function (e.g. changes from the object damage).
- 1 September 2008
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 144, 39-44
Analytic Description of Impulse Response Signals
The paper describes a method of analytic description of impulse response (IR) signals obtained during the test of technical object. The proposed description is based on the curve fitting to obtain the values of the parameters of analytic form of auto-correlation and power spectral density function. The impulse excitation is given into thoroughly described points of object and the proper fragment of IR is selected in the order to assure the accuracy of the curve fitting over the level of 90%. This approach enables to describe changes of IR signals in the form of percentage variations in the parameters of the auto-correlation and power spectral density function (e.g. changes from the object damage).