PWPeter Josef Wlasits

Peter Josef Wlasits

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Josef Wlasits has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Aerial Mapping of (Bio)aerosols Using Dual UAV Platforms in an Austrian Spruce Forest.

    by Florian Wieland, Matthäus Rupprecht, Jasper Cameron, Lucie Farell, Jürgen Gratzl, Regina Hanlon, Jordan Horral, Julia Lane, Pascal Langer, Jordan Lavey, et al.

    Forests are dynamic sources and sinks of primary biological aerosol particles (PBAPs) that influence ecosystem health, atmospheric chemistry, and climate. However, the spatial and temporal distribution of these particles in and above forest canopies remains poorly understood. In this study, we deployed two complementary UAV platforms to characterize bioaerosol concentrations, composition, and environmental drivers in a spruce forest in Wienerwald, Lower Austria.Sampling campaigns in June and July 2024 utilized a suite of sensors on the UAVs, including portable optical particle counters (POPS, 0.16 – 3.37 µm), impingers, and PM-, VOC & meteorological sensors. These aerial measurements were referenced against a ground station including a Wideband Integrated Bioaerosol Sensor (WIBS-5/NEO, 0.5 – 30 µm) and a Grimm 11-D (0.25 – 35.15 µm) aerosol spectrometer, and the same set of PM-, VOC & meteorological sensors. Two additional sampling days were conducted in June 2025 with additional UAV-based aerosol- and VOC-sampling.We observed higher overall particle number concentrations at near-canopy altitudes (2.5 μm) particles were biological. Their fluorescence signature and elevated concentration at high relative humidities suggest a large contribution of fungal spores, which was confirmed by microscopy of samples from ground-based and, in 2025, UAV-mounted cascade impactor sampling. PBAP concentrations generally increased with high relative humidity, consistent with well-documented humidity-driven enhancements in biological particle release.This multi-platform UAV approach provides a robust framework for resolving forest-atmosphere exchange processes, yielding critical data to improve atmospheric models and our understanding of ecosystem-climate feedback loops.

  • Open Access

    Development and testing of a fluorescence-based UAV-mountable sensor for PBAP monitoring in the lower troposphere

    by Matthäus Rupprecht, Florian Wieland, Peter J. Wlasits, Philipp Sterlich, Gerhard Peller, Hinrich Grothe

    Primary Biological Aerosol Particles (PBAPs) are ubiquitous in Earth’s atmosphere and have been repeatedly shown to affect human health in adverse ways as allergens or disease vectors. Their role in heterogenous freezing is also attracting increasing interest and many PBAPs are regarded as Ice Nucleating Particles (INPs) This makes PBAPs a crucial factor for Earth’s Climate. These phenomena emphasise the importance of spatially resolved information on PBAP concentrations. Current instruments use UV fluorescence spectroscopy to study PBAPs in ambient air samples, however the size and weight of these instruments limit this technique to ground- or plane-based measurements, leaving a blind spot to the lower troposphere. This highlights the need for miniaturised, UAV-mountable fluorescence spectrometers that can provide spatially resolved PBAP data from low altitudes.To address this demand, a 3D-printed fluorescence chamber was developed and successfully tested under laboratory conditions. Due to its compact, lightweight and adaptable nature, it can be operated under UAV conditions. This was then coupled with an optical particle counter and expanded to include a wide range of different on- and offline instruments, to form a modular UAV-mountable measurement system capable of monitoring fluorescence information, particle size and mass distributions and a variety of meteorological data.This setup was successfully used during a multi-day field campaign in Steinalpl, Styria, Austria in summer 2025. During the campaign the setup was flown consistently over an area consisting of meadows and a spruce forest suffering from heavy bark beetle infestation. The novel fluorescence spectrometer proved reliable, producing data on every flight without interruption. Preliminary results show that terrain changes can clearly be observed in the fluorescence data and that it shows correlation to other instruments from the setup, which underlines the quality of the data produced and demonstrates that the developed lightweight UAV-mountable spectrometer is an important step towards online monitoring of PBAPs in the lower troposphere.

  • Open Access

    Physical and Chemical Characterisation of Nanoplastic Aerosol 

    by Peter J. Wlasits, Paul M. Winkler

    Physical and Chemical Characterisation of Nanoplastic Aerosol Peter J. Wlasits1, and Paul M. Winkler11 Faculty of Physics, University of Vienna, Vienna, Austria Mass production of plastic products has led to an environmental problem on global scale. Consequently, an increasing number of studies has investigated the impact of micro- and nanoplastics on the environment in recent years (e. g. Amobonye et al., 2021). As a consequence of their small sizes, nanoplastic particles undergo long range atmospheric transport and deposit in remote regions (Materić et al., 2021; 2022). Hence, measurement techniques capable of accurately detecting nanoplastic aerosol are urgently needed. The presented project, funded by the Austrian Science Fund (FWF) [10.55776/PAT5114323], relies on the controlled generation of nanoplastic particles from gas-to-particle conversion (Wlasits et al., 2022). The aforementioned generation method enables process level studies under well-defined laboratory conditions. Accordingly, nanoplastic aerosols will be generated by exposing selected macroplastics to thermal stress in a tube furnace (Wlasits et al., 2022). Aerosol particles will then be size selected using a differential mobility analyser and subsequently fed into detectors for physical and chemical analysis. The chemical composition of the generated particles will be investigated using an atmospheric pressure interface time-of-flight mass spectrometer, capable of analysing particles of both polarities simultaneously. Prior to mass analysis particles will undergo thermal decomposition and ionisation. Physical characterisation will be performed using the Size Analysing Nuclei Counter (SANC), an expansion-type condensation particle counter providing nucleation probabilities as a function of the saturation ratio (Wlasits et al., 2023). In summary, the outlined project is based on a comprehensive experimental approach combining physical and chemical information about nanoplastic aerosol. New insights on the influence of nanoplastic particles on cloud formation will be gained and the potential use of condensation techniques for nanoplastic detection will be investigated. ReferencesAmobonye, A., Bhagwat, P. , Raveendran, S., Singh, S., and Pillai, S., Microbiol., 12, 768297, 2021, doi:10.3389/fmicb.2021.768297.Materić, D., Ludewig, E., Brunner, D., Röckmann, T., and Holzinger, R., Environ. Pollut., 288, 117697, 2021, doi:10.1016/j.envpol.2021.117697.Materić, D., Kjær, H. A., Vallelonga, P., Tison, J.-L., Röckmann, T., and Holzinger, R., Environ. Res., 208, 112741, 2022, doi:10.1016/j.envres.2022.112741.Wlasits, P. J., Stoellner, A., Lattner, G., Maggauer, K., and Winkler, P. M., Aerosol Sci. Technol., 56 (2), 176–185, 2022, doi:10.1080/02786826.2021.1998339.Wlasits, P. J., Konrat, R., and Winkler, P. M., Environ. Sci. Technol., 57 (4), 1584–1591, 2023, doi:10.1021/acs.est.2c07643.

  • Open Access

    UAV-based aerosol and VOC measurements above a spruce forest canopy in Lower Austria

    by Florian Wieland, Matthäus Rupprecht, Peter J. Wlasits, Jürgen Gratzl, Pascal Langer, Vanessa Treml, Jordan Horral, Cayden Smedley, Regina Hanlon, David Schmale Iii, et al.

    Forests are increasingly recognized as significant sources of biogenic aerosols, impacting air quality and climate. However, understanding the distribution and transport of these aerosols within and above forest canopies remains a challenge. This study investigates the vertical profiles of aerosol and volatile organic compound (VOC) concentrations above a spruce forest in Lower Austria using a novel analytical instrument packages on Uncrewed Aerial Vehicles (UAV).In our campaign we used multiple UAVs outfitted with various air quality sensors to monitor aerosol concentrations above natural and managed forests. Here, we describe the use of a drone aerosol analytics package consisting of a volatile organic compounds (VOC) sensor, a portable optical particle spectrometer (POPS), and an environmental sensor module to investigate particle emissions at different heights above a spruce forest within Wienerwald in Lower Austria. This package was compared to simultaneous measurements with other drone-based and ground-based systems, including optical particle counters (OPCs) and impingers.Preliminary results showed higher particle number concentrations across all size channels (0.115 – 3.370 µm) at near-canopy altitudes ( 5m above the canopy). Furthermore, our results point towards a height dependence of VOC concentrations, where VOC concentrations strongly decrease with increasing height. Future work aims to use drone-based aerosol measurements above forest canopies to assist in gauging forest health, such as identifying early warnings of attack by pathogens or insects.

  • Open Access

    Reduced particle composition dependence in condensation particle counters

    by Peter J. Wlasits, Joonas Enroth, Joonas Vanhanen, Aki Pajunoja, Hinrich Grothe, Paul M. Winkler, Dominik Stolzenburg

    Modern condensation particle counters (CPCs) are indispensable instruments for studies of aerosols in all measurement environments. Relying on heterogeneous nucleation as the basic principle, the composition dependence of particle activation is a source of profound uncertainty for the accurate assessment of new particle formation (NPF) events. While development efforts successfully pushed down minimum detectable particle sizes in recent years, composition-dependent counting efficiencies have remained to be a persisting issue in aerosol research. Addressing this pressing problem, we present calibrations of a newly developed CPC, the Airmodus A30 (Airmodus Ltd., Helsinki, Finland), that uses non-hazardous propylene glycol as working fluid. Our results conclusively demonstrate that composition-dependent particle detection can be reduced to the brink of disappearance by choice of the working fluid and corresponding high supersaturation. Counting efficiencies were determined for a set of size-selected and chemically diverse seed particles, and the measured 50 % cutoff diameters were compared to previous studies. Using computational fluid dynamics simulations, we show that the composition dependence appears to decrease with increasing saturation ratios achieved inside the CPC. Hence, our study assists in the development of future CPCs and elucidates a potential mechanism to reduce measurement uncertainties arising from composition-dependent counting efficiencies.


  • Open Access

    Reduced seed-material dependence of a condensation particle counter

    by Peter Josef Wlasits, Joonas Enroth, Joonas Vanhanen, Aki Pajunoja, Hinrich Grothe, Paul Martin Winkler, Dominik Stolzenburg

    Modern condensation particle counters (CPCs) are indispensable instruments for studies of aerosols in all measurement environments. Relying on heterogeneous nucleation as basic principle, the composition dependence of particle activation is a source of profound uncertainty for the accurate assessment of particle number concentrations. While development efforts successfully pushed down minimum detectable particle sizes in recent years, composition-dependent counting efficiencies have remained to be a persisting issue in aerosol research. Addressing this pressing problem, we present calibrations of a newly developed CPC, the Airmodus A30, that uses non-hazardous propylene glycol as working fluid. Our results conclusively demonstrate that composition-dependent particle detection can be reduced to the brink of disappearance by innovative choice of the working fluid. Counting efficiencies were determined for a set of size-selected and chemically diverse seed particles and the measured 50 % cutoff diameters were compared to previous studies. Using computational fluid dynamics simulations, we show that the composition dependence appears to decrease with increasing saturation ratios achieved inside the CPC. Hence, our study assists in the development of future CPCs and elucidates a potential mechanism to reduce measurement uncertainties arising from composition-dependent counting efficiencies.

  • Open Access

    Supplementary material to "Reduced seed-material dependence of a condensation particle counter"

    by Peter Josef Wlasits, Joonas Enroth, Joonas Vanhanen, Aki Pajunoja, Hinrich Grothe, Paul Martin Winkler, Dominik Stolzenburg

  • Open Access

    Heterogeneous Nucleation of Supersaturated Water Vapor onto Sub-10 nm Nanoplastic Particles

    by Peter J. Wlasits, Ruth Konrat, Paul M. Winkler

    Nanoplastic pollution by atmospheric transport processes is a recently discovered environmental problem on a global scale that is attributed to the dispersion of aerosolized nanoplastics. However, knowledge about the basic physicochemical properties of aerosol nanoplastic particles is scarce. Here, we present experiments on the heterogeneous nucleation of supersaturated water vapor onto sub-10 nm polyethylene terephthalate (PET) seeds. We determined onset saturation ratios for the activation of PET seeds in comparison to the well-documented reference system of silver particles, resulting in lower onset saturation ratios of the PET seeds compared to silver seeds. By using different PET bulk materials for the generation of nanoparticles, we report a strong material dependence of the onset saturation ratios, pointing to a strong effect of additives from commodity plastics in heterogeneous nucleation. Moreover, our results show a strong dependence on nucleation temperature that might be of immediate atmospheric relevance. Our work can be considered as an initial step in airborne nanoplastic detection by condensation techniques, and we anticipate our study to serve as a basis for further research that will eventually allow assessing the impact of nanoplastic dispersion on atmospheric processes.


  • Open Access

    Size characterization and detection of aerosolized nanoplastics originating from evaporated thermoplastics

    by Peter Josef Wlasits, Andrea Stoellner, Gregor Lattner, Klara Maggauer, Paul Martin Winkler

    In recent years, a growing number of studies investigated the presence of micro- and nanoscopic particles in the environment originating from commonly used plastics. Pathways into the environment and generation mechanisms are still not well understood. Controlled generation methods of particles from macroplastics are required to enable research of the fundamental processes governing the dispersion of these particles in the environment. Here, we present the results of a study focusing on the generation and characterization of aerosol nanoparticles from macroplastics using a tube furnace. Three common thermoplastics were used as particle material: Polyethene (PE), Polypropene (PP) and Polyethylene Terephthalate (PET). Commodity versions of these materials were compared to higher-purity versions. The produced particles were size characterized using a Differential Mobility Particle Sizer. Furthermore, we investigated the activation of particles from PET in Condensation Particle Counters by measuring the 50% cut-off diameters. The results could be directly compared to previous measurements using other organic seed particles. Our study provides crucial insights into the effects governing the production of aerosolized nanoparticles from thermoplastics at comparatively low temperatures. We therefore expect our study to act as basis for further research towards a thorough understanding of the physicochemical processes governing nanoparticle production from plastic materials. Eventually this may lead to new detection methods of nanoplastics in airborne state and allow for quantification of airborne nanoplastic concentrations.


  • Open Access

    Characterization of a non-thermal plasma source for use as a mass specrometric calibration tool and non-radioactive aerosol charger

    by Christian Tauber, David Schmoll, Johannes Gruenwald, Sophia Brilke, Peter Josef Wlasits, Paul Martin Winkler, Daniela Wimmer

    In this study the charging efficiency of a radioactive and a non-radioactive plasma bipolar diffusion charger (Gilbert Mark I plasma charger) for sub-12 nm particles has been investigated at various aerosol flow rates. The results were compared to classic theoretical approaches. In addition, the chemical composition and electrical mobilities of the charger ions have been examined using an atmospheric pressure interface time-of-flight mass spectrometer (APi-TOF MS). A comparison of the different neutralization methods revealed an increased charging efficiency for negatively charged particles using the non-radioactive plasma charger with nitrogen as the working gas compared to a radioactive americium bipolar diffusion charger. The mobility and mass spectrometric measurements show that the generated bipolar diffusion charger ions are of the same mobilities and composition independent of the examined bipolar diffusion charger. It was the first time that the Gilbert Mark I plasma charger was characterized in comparison to a commercial TSI X-Ray (TSI Inc, Model 3088) and a radioactive americium bipolar diffusion charger. We observed that the plasma charger with nitrogen as the working gas can enhance the charging probability for sub-10 nm particles compared to a radioactive americium bipolar diffusion charger. As a result, the widely used classical charging theory disagrees for the plasma charger and for the radioactive chargers with increased aerosol flow rates. Consequently, in-depth measurements of the charging distribution are necessary for accurate measurements with differential or scanning particle sizers for laboratory and field applications.