Adrian J. Wilson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Adrian J. Wilson has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
B H Brown
3 shared publicationsC. I. Franks
Royal Hallamshire Hospital
3 shared publications- Pedro Bertemes-Filho
Santa Catarina State University
3 shared publications A. D. Milner
Queen's Medical Centre
2 shared publicationsChris Imray
Department of Vascular and Renal Transplant Surgery, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
2 shared publicationsD P Southall
National Heart and Lung Institute, London, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 31 March 2026
- Published by BMJ in BMJ Innovations
- Vol. 12 (2) , 86-94
Robustness and value of data from the Oura Ring for personal monitoring in extreme environments with implications for clinical use: an observational study in an unassisted ski traverse of Antarctica
Objective: To evaluate the completeness and quality of Oura Ring data in a remote environment. Setting: The INSPIRE22 medical research expedition, a 950 km, 47-day unassisted trek from the Ronne Ice Shelf/land junction to the South Pole. Participants: Nine participants (six male) from either the UK military or civilians with experience of extreme environments and/or expedition medicine. Primary and secondary outcome measures: The primary outcome measures were missing data from the Ora Ring for movement measurement during six distinct activity periods within a day and heart rate (HR) during sleep. The secondary outcome measures were the agreement between movement measurement by the Oura Ring and a wrist-worn GENEActiv device for both an average day and the activity periods. Results: Overall, 3.2% of the minute-by-minute movement values were missing with a day-to-day variation of 0% to 83%. For the six activity periods, the median lowest incidence of missing values across participants was 4.44% (range 0–13.3%) during night-time and the highest 16.7% (range 6.67–60.0%) during sleep preparation. Agreement between the GENEActiv and Oura Ring measurements was activity-period dependent (r 2 =0.05–0.44). A Bland-Altman plot demonstrated a mean difference between the two devices for an average day of 0.41 (95% CI −0.45 to 1.27). For HR, the number of nights when data were available across participants ranged from 27 to 47. Within those nights, the median percentage of missing values across participants ranged from 5.99% to 18.2%. Conclusion: Research and healthcare relying on wearable technology should prioritise devices providing unprocessed data for robustness.
- 31 March 2026
- Published by BMJ in BMJ Innovations
- Vol. 12 (2) , 86-94
Open AccessRobustness and value of data from the Oura Ring for personal monitoring in extreme environments with implications for clinical use: an observational study in an unassisted ski traverse of Antarctica
Objective: To evaluate the completeness and quality of Oura Ring data in a remote environment. Setting: The INSPIRE22 medical research expedition, a 950 km, 47-day unassisted trek from the Ronne Ice Shelf/land junction to the South Pole. Participants: Nine participants (six male) from either the UK military or civilians with experience of extreme environments and/or expedition medicine. Primary and secondary outcome measures: The primary outcome measures were missing data from the Ora Ring for movement measurement during six distinct activity periods within a day and heart rate (HR) during sleep. The secondary outcome measures were the agreement between movement measurement by the Oura Ring and a wrist-worn GENEActiv device for both an average day and the activity periods. Results: Overall, 3.2% of the minute-by-minute movement values were missing with a day-to-day variation of 0% to 83%. For the six activity periods, the median lowest incidence of missing values across participants was 4.44% (range 0–13.3%) during night-time and the highest 16.7% (range 6.67–60.0%) during sleep preparation. Agreement between the GENEActiv and Oura Ring measurements was activity-period dependent (r 2 =0.05–0.44). A Bland-Altman plot demonstrated a mean difference between the two devices for an average day of 0.41 (95% CI −0.45 to 1.27). For HR, the number of nights when data were available across participants ranged from 27 to 47. Within those nights, the median percentage of missing values across participants ranged from 5.99% to 18.2%. Conclusion: Research and healthcare relying on wearable technology should prioritise devices providing unprocessed data for robustness.
- Open Access
- 9 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Changes in peripheral IR thermography and energy expenditure on cooling in men and women following sustained strenuous activity in Antarctica
We studied pre- to post-expedition changes in hand temperature measured by infrared (IR) thermography and energy expenditure during whole body cooling of Inspire-22 participants (6 M,3 F). Measurements were made in a whole-body calorimeter at the end of a 36-h protocol when the ambient temperature was reduced by ≈ 5.5 °C over a period of 2 h after which IR images of both hands were taken. After 1-h of re-warming, the imaging was repeated. The mean temperature of the finger and non-finger regions were determined. A line-of-best-fit and its 95% CI were used to estimate the change in energy expenditure (EE) for 100 min of cooling. Pre-expedition 5 participants showed an increased, 2 no-change and 2 decreased EE; post-expedition the corresponding values were 5, 1 and 3 respectively. There was no difference in these proportions between pre- and post-expedition measurements (χ2; p > 0.05). An Applied Rank Transform non-parametric ANOVA for small samples found no significant difference in the cool-warm temperatures for sex of the participants nor whether measurements were made pre- or post-expedition (p > 0.05). Graphical analysis showed no association between the change in EE and the change in hand-to-background temperature on cooling suggesting reduced peripheral circulation was not an explanation for reduced EE on cooling.
- 9 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessChanges in peripheral IR thermography and energy expenditure on cooling in men and women following sustained strenuous activity in Antarctica
We studied pre- to post-expedition changes in hand temperature measured by infrared (IR) thermography and energy expenditure during whole body cooling of Inspire-22 participants (6 M,3 F). Measurements were made in a whole-body calorimeter at the end of a 36-h protocol when the ambient temperature was reduced by ≈ 5.5 °C over a period of 2 h after which IR images of both hands were taken. After 1-h of re-warming, the imaging was repeated. The mean temperature of the finger and non-finger regions were determined. A line-of-best-fit and its 95% CI were used to estimate the change in energy expenditure (EE) for 100 min of cooling. Pre-expedition 5 participants showed an increased, 2 no-change and 2 decreased EE; post-expedition the corresponding values were 5, 1 and 3 respectively. There was no difference in these proportions between pre- and post-expedition measurements (χ2; p > 0.05). An Applied Rank Transform non-parametric ANOVA for small samples found no significant difference in the cool-warm temperatures for sex of the participants nor whether measurements were made pre- or post-expedition (p > 0.05). Graphical analysis showed no association between the change in EE and the change in hand-to-background temperature on cooling suggesting reduced peripheral circulation was not an explanation for reduced EE on cooling.
- Open Access
- 31 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0335735
Changes in metabolic energy measures for daily living activities and exercise in men and women following arduous activity in Antarctica
This study reports pre- to post-expedition (pre|post) changes in energy expenditure and substrate utilisation during daily living activities (DLAs including rest, sleep, modest exercise, sedentary work and leisure) and maximum aerobic power ( V ˙ O2max ) for participants in the Inspire-22 expedition (6 men, 3 women) who undertook a 47 day unassisted Antarctic traverse from the Ronne Ice Shelf to the South Pole. DLA measurements were carried out during a 36 hour study in a whole-body calorimeter whilst measurements of maximum oxygen uptake ( V ˙ O2max ), capillary glucose and lactate during incremental stepping exercise to volitional exhaustion were carried out under normobaric normoxic and hypoxic (14% O2) conditions in an environmental chamber. Non-exercise measures were normalised to non-fat tissue weight; exercise measures, including those in the DLAs, to body weight. Statistical analysis used the Aligned Rank Transform (ART) non-parametric ANOVA technique with covariants pre|post expedition, sex and hypoxia|normoxia as appropriate. There were no systematic differences between pre- and post-expedition energy expenditure but significant differences between men and women for the majority of the DLAs (p < 0.05). There was increased carbohydrate utilisation post-expedition for sleep and the two lower intensity exercise levels (p < 0.05) but not during rest or the highest intensity exercise (p > 0.05); a sex-independent subset of 4 showing much higher utilisation. Women had a lower protein utilisation than men during the DLA exercise activities (p < 0.05). V ˙ O2max was lower in hypoxia than normoxia (p < 0.001) and reduced glucose and lactate between pre- and post-expedition measures. There was also a significant interaction between sex and pre|post measurements for V ˙ O2max and lactate suggesting that adaptation to the environment and high workloads was different between men and women; a suggestion supported by the difference in fat-free tissue measured pre- and post-expedition, but neither sex showed major differences between the pre- and post-expedition measurements.
- 31 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0335735
Open AccessChanges in metabolic energy measures for daily living activities and exercise in men and women following arduous activity in Antarctica
This study reports pre- to post-expedition (pre|post) changes in energy expenditure and substrate utilisation during daily living activities (DLAs including rest, sleep, modest exercise, sedentary work and leisure) and maximum aerobic power ( V ˙ O2max ) for participants in the Inspire-22 expedition (6 men, 3 women) who undertook a 47 day unassisted Antarctic traverse from the Ronne Ice Shelf to the South Pole. DLA measurements were carried out during a 36 hour study in a whole-body calorimeter whilst measurements of maximum oxygen uptake ( V ˙ O2max ), capillary glucose and lactate during incremental stepping exercise to volitional exhaustion were carried out under normobaric normoxic and hypoxic (14% O2) conditions in an environmental chamber. Non-exercise measures were normalised to non-fat tissue weight; exercise measures, including those in the DLAs, to body weight. Statistical analysis used the Aligned Rank Transform (ART) non-parametric ANOVA technique with covariants pre|post expedition, sex and hypoxia|normoxia as appropriate. There were no systematic differences between pre- and post-expedition energy expenditure but significant differences between men and women for the majority of the DLAs (p < 0.05). There was increased carbohydrate utilisation post-expedition for sleep and the two lower intensity exercise levels (p < 0.05) but not during rest or the highest intensity exercise (p > 0.05); a sex-independent subset of 4 showing much higher utilisation. Women had a lower protein utilisation than men during the DLA exercise activities (p < 0.05). V ˙ O2max was lower in hypoxia than normoxia (p < 0.001) and reduced glucose and lactate between pre- and post-expedition measures. There was also a significant interaction between sex and pre|post measurements for V ˙ O2max and lactate suggesting that adaptation to the environment and high workloads was different between men and women; a suggestion supported by the difference in fat-free tissue measured pre- and post-expedition, but neither sex showed major differences between the pre- and post-expedition measurements.
- Open Access
- 22 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Preserved circadian variation in cortisol and androgens during a ski traverse of Antarctica in summer
Antarctic expeditions present extreme physiological challenges due to cold temperatures, high physical exertion, and 24-hour daylight. This observational study evaluated endocrine adaptation in nine participants (six men, three women) during a 47-day, 1,000 km unassisted ski traverse. Detailed salivary sampling was conducted before, during and after the expedition, corroborated by blood and hair sampling before and after the expedition. Cortisol, testosterone, and androstenedione were measured using mass spectrometry, and thyroid hormones via immunoassay. Diurnal cortisol, androstenedione and testosterone variation was preserved, while the morning cortisol increased during the expedition, suggesting that exercise demands overshadow the effects of continuous daylight in controlling hypothalamic-pituitary-adrenal and gonadal axis function. Morning testosterone decreased during the expedition, with a greater effect seen among men. No significant changes were seen in blood or hair steroid hormones. Gonadotropins in women indicated central suppression pre-expedition, normalizing post-expedition. Thyroid-stimulating hormone levels increased post-expedition without significant changes in free T3 or T4, consistent with mild polar T3 syndrome. These findings highlight the adaptability of hypothalamic-pituitary function to combined stressors of exercise, energy deficit, and cold. This is the first study to capture in situ endocrine responses during an Antarctic traverse, advancing our understanding of human adaptation in extreme environments.
- 22 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessPreserved circadian variation in cortisol and androgens during a ski traverse of Antarctica in summer
Antarctic expeditions present extreme physiological challenges due to cold temperatures, high physical exertion, and 24-hour daylight. This observational study evaluated endocrine adaptation in nine participants (six men, three women) during a 47-day, 1,000 km unassisted ski traverse. Detailed salivary sampling was conducted before, during and after the expedition, corroborated by blood and hair sampling before and after the expedition. Cortisol, testosterone, and androstenedione were measured using mass spectrometry, and thyroid hormones via immunoassay. Diurnal cortisol, androstenedione and testosterone variation was preserved, while the morning cortisol increased during the expedition, suggesting that exercise demands overshadow the effects of continuous daylight in controlling hypothalamic-pituitary-adrenal and gonadal axis function. Morning testosterone decreased during the expedition, with a greater effect seen among men. No significant changes were seen in blood or hair steroid hormones. Gonadotropins in women indicated central suppression pre-expedition, normalizing post-expedition. Thyroid-stimulating hormone levels increased post-expedition without significant changes in free T3 or T4, consistent with mild polar T3 syndrome. These findings highlight the adaptability of hypothalamic-pituitary function to combined stressors of exercise, energy deficit, and cold. This is the first study to capture in situ endocrine responses during an Antarctic traverse, advancing our understanding of human adaptation in extreme environments.
- Open Access
- 10 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0308804
Changes in body composition and average daily energy expenditure of men and women during arduous extended polar travel
Weight and skin-fold measurements were made at five-day intervals during a 47-day expedition by six men and three women from the edge of the sea ice to the South Pole. From these, together with detailed manual records of the nutrition for individual participants, the average daily energy expenditure was determined before and after a resupply at approximately mid-point of the expedition. For all participants body weight fell during the expedition with the overall loss being much smaller for the three female participants (-4.0, -4.0, -4.4kg) than for the male participants, (mean±sd) -8.6±2.0kg. Fat weight fell approximately linearly during the expedition with a total loss of (-4.1, -6.5 and -2.5kg) for the three female participants and -6.8±1.7kg for the male participants. Individual fat-free weight changed by a smaller amount overall: (0.13, 2.5 and -1.8kg) for the three female participants; -1.8±2.0kg for the male participants who, with one exception, lost fat-free tissue All participants showed a substantial variation in fat-free tissue weight during the expedition. Analysis of the daily energy expenditure showed adequate nutrition but the intake fell for the second part of the expedition although the reasons for this are unclear, but adaptation to the cold, altitude and workload are possible explanations. The validity of this time-averaged measurement for individual participants was determined from analysing moments about the mean of time-series actigraphy data from wrist worn devices. The mean and autocorrelation function of the actigraphy data across subjects were analysed to determine whether measures could be compared between participants. The first, second and third moment about the mean of the day-to-day activity was found to be time-invariant for individual subjects (χ2, p>0.05) and the normalized mean and autocorrelation measured over a day for each participant indistinguishable from the mean of the group (χ2, p>0.05) allowing both longitudinal and cross-sectional analysis.
- 10 October 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0308804
Open AccessChanges in body composition and average daily energy expenditure of men and women during arduous extended polar travel
Weight and skin-fold measurements were made at five-day intervals during a 47-day expedition by six men and three women from the edge of the sea ice to the South Pole. From these, together with detailed manual records of the nutrition for individual participants, the average daily energy expenditure was determined before and after a resupply at approximately mid-point of the expedition. For all participants body weight fell during the expedition with the overall loss being much smaller for the three female participants (-4.0, -4.0, -4.4kg) than for the male participants, (mean±sd) -8.6±2.0kg. Fat weight fell approximately linearly during the expedition with a total loss of (-4.1, -6.5 and -2.5kg) for the three female participants and -6.8±1.7kg for the male participants. Individual fat-free weight changed by a smaller amount overall: (0.13, 2.5 and -1.8kg) for the three female participants; -1.8±2.0kg for the male participants who, with one exception, lost fat-free tissue All participants showed a substantial variation in fat-free tissue weight during the expedition. Analysis of the daily energy expenditure showed adequate nutrition but the intake fell for the second part of the expedition although the reasons for this are unclear, but adaptation to the cold, altitude and workload are possible explanations. The validity of this time-averaged measurement for individual participants was determined from analysing moments about the mean of time-series actigraphy data from wrist worn devices. The mean and autocorrelation function of the actigraphy data across subjects were analysed to determine whether measures could be compared between participants. The first, second and third moment about the mean of the day-to-day activity was found to be time-invariant for individual subjects (χ2, p>0.05) and the normalized mean and autocorrelation measured over a day for each participant indistinguishable from the mean of the group (χ2, p>0.05) allowing both longitudinal and cross-sectional analysis.
- Open Access
- 14 February 2024
- Published by Elsevier in IPEM-Translation
- Vol. 9
Towards a locally constructed multi-element ultrasound imaging transducer for resource poor environments
- 14 February 2024
- Published by Elsevier in IPEM-Translation
- Vol. 9
Open AccessTowards a locally constructed multi-element ultrasound imaging transducer for resource poor environments
- Open Access
- 12 December 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 6 (1) , tzae002
Changes in lumbar muscle diffusion tensor indices with age
To investigate differences in diffusion tensor imaging (DTI) parameters and proton density fat fraction (PDFF) in the spinal muscles of younger and older adult males. Twelve younger (19-30 years) and 12 older (61-81years) healthy, physically active male participants underwent T1W, T2W, Dixon and DTI of the lumbar spine. The eigenvalues (λ1, λ2, and λ3), fractional anisotropy (FA), and mean diffusivity (MD) from the DTI together with the PDFF were determined in the multifidus, medial and lateral erector spinae (ESmed, ESlat), and quadratus lumborum (QL) muscles. A two-way ANOVA was used to investigate differences with age and muscle and t-tests for differences in individual muscles with age. The ANOVA gave significant differences with age for all DTI parameters and the PDFF (P < .01) and with muscle (P < .01) for all DTI parameters except for λ1 and for the PDFF. The mean of the eigenvalues and MD were lower and the FA higher in the older age group with differences reaching statistical significance for all DTI measures for ESlat and QL (P < .01) but only in ESmed for λ3 and MD (P < .05). Differences in DTI parameters of muscle with age result from changes in both in the intra- and extra-cellular space and cannot be uniquely explained in terms of fibre length and diameter. Previous studies looking at age have used small groups with uneven age spacing. Our study uses two well defined and separated age groups.
- 12 December 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 6 (1) , tzae002
Open AccessChanges in lumbar muscle diffusion tensor indices with age
To investigate differences in diffusion tensor imaging (DTI) parameters and proton density fat fraction (PDFF) in the spinal muscles of younger and older adult males. Twelve younger (19-30 years) and 12 older (61-81years) healthy, physically active male participants underwent T1W, T2W, Dixon and DTI of the lumbar spine. The eigenvalues (λ1, λ2, and λ3), fractional anisotropy (FA), and mean diffusivity (MD) from the DTI together with the PDFF were determined in the multifidus, medial and lateral erector spinae (ESmed, ESlat), and quadratus lumborum (QL) muscles. A two-way ANOVA was used to investigate differences with age and muscle and t-tests for differences in individual muscles with age. The ANOVA gave significant differences with age for all DTI parameters and the PDFF (P < .01) and with muscle (P < .01) for all DTI parameters except for λ1 and for the PDFF. The mean of the eigenvalues and MD were lower and the FA higher in the older age group with differences reaching statistical significance for all DTI measures for ESlat and QL (P < .01) but only in ESmed for λ3 and MD (P < .05). Differences in DTI parameters of muscle with age result from changes in both in the intra- and extra-cellular space and cannot be uniquely explained in terms of fibre length and diameter. Previous studies looking at age have used small groups with uneven age spacing. Our study uses two well defined and separated age groups.
- 21 August 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1103) , 20190300
An investigation into the effect of body mass index on the agreement between whole-body fat mass determined by MRI and air-displacement plethysmography
To validate MRI fat measurement protocols using purpose built test objects and by comparison with air-displacement plethysmography (ADP) whole-body fat measurements in non-obese subjects. Test objects of known fat concentration were used to quantify the accuracy of the MRI measurements. 10 participants with a body mass index in the range 18–30 underwent whole-body MRI using two different Dixon-based sequences (LAVA Flex and IDEAL IQ) to obtain an estimate of their whole-body fat mass. The MRI determined fat mass was compared to the fat mass determined by ADP. MRI test object measurements showed a high correlation to expected fat percentage (r > 0.98). The participant MRI and ADP results were highly correlated (r = 0.99) but on average (mean ± standard deviation) MRI determined a higher fat mass than ADP (3.8 ± 3.1 kg for LAVA Flex and 1.9 ± 3.2 kg for IDEAL IQ). There was no trend in the difference between MRI and ADP with total fat mass. The good agreement between MRI and ADP shows that Dixon-based MRI can be used effectively as a tool in physiological research for non-obese adults. This work found that for ten non-obese subjects body mass index had no effect on the MRI determination of whole-body fat mass.
- 21 August 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1103) , 20190300
An investigation into the effect of body mass index on the agreement between whole-body fat mass determined by MRI and air-displacement plethysmography
To validate MRI fat measurement protocols using purpose built test objects and by comparison with air-displacement plethysmography (ADP) whole-body fat measurements in non-obese subjects. Test objects of known fat concentration were used to quantify the accuracy of the MRI measurements. 10 participants with a body mass index in the range 18–30 underwent whole-body MRI using two different Dixon-based sequences (LAVA Flex and IDEAL IQ) to obtain an estimate of their whole-body fat mass. The MRI determined fat mass was compared to the fat mass determined by ADP. MRI test object measurements showed a high correlation to expected fat percentage (r > 0.98). The participant MRI and ADP results were highly correlated (r = 0.99) but on average (mean ± standard deviation) MRI determined a higher fat mass than ADP (3.8 ± 3.1 kg for LAVA Flex and 1.9 ± 3.2 kg for IDEAL IQ). There was no trend in the difference between MRI and ADP with total fat mass. The good agreement between MRI and ADP shows that Dixon-based MRI can be used effectively as a tool in physiological research for non-obese adults. This work found that for ten non-obese subjects body mass index had no effect on the MRI determination of whole-body fat mass.
- 1 July 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (14) , 145009
Towards using a focussed phased array of millimetre length scale elements for ultrasound imaging
Sparse phased array ultrasound transducers with millimetre length scale elements have previously been proposed for generating hyperthermia but not for imaging. Numerical simulation with a pseudospectral solver was used to investigate: (a) how the position of the maximum pressure in the focal region changed with element diameter and frequency; (b) how the size and position of the focal region changed with focal distance under steering; and (c) the imaging performance of 15 element random arrays. These analyses were performed for both piston-like and non piston-like millimetre diameter elements since previous work has shown a shift in the distance to the maximum pressure in the focal region with the latter. The results for these elements were compared with elements where the diameter was < λ /2. The distance from the array to the position of maximum pressure in the focal region diverged from the value with element diameter < λ /2; values for piston-like elements increased positively whilst values for non piston-like elements increased negatively. With distances expressed in λ , no difference was found for arrays at 1 MHz and 2.5 MHz. For piston-like elements, but not for non piston-like elements, two peaks were found in the focal region which were in-line with the direction of propagation for a focus on the central axis but which rotated to become parallel with the direction of propagation when steering exceeded 20°. The size and position of the focal region under steering was similar for the non piston-like elements and elements with diameter < λ /2. Little difference was found in image quality or the size of the point spread function (PSF) between images at 2.5 MHz with piston-like and non piston-like behaviour for steering angles less than 20° when compared with a linear array of similar size. These results suggest that imaging with random arrays of millimetre length scale elements is possible.
- 1 July 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (14) , 145009
Towards using a focussed phased array of millimetre length scale elements for ultrasound imaging
Sparse phased array ultrasound transducers with millimetre length scale elements have previously been proposed for generating hyperthermia but not for imaging. Numerical simulation with a pseudospectral solver was used to investigate: (a) how the position of the maximum pressure in the focal region changed with element diameter and frequency; (b) how the size and position of the focal region changed with focal distance under steering; and (c) the imaging performance of 15 element random arrays. These analyses were performed for both piston-like and non piston-like millimetre diameter elements since previous work has shown a shift in the distance to the maximum pressure in the focal region with the latter. The results for these elements were compared with elements where the diameter was < λ /2. The distance from the array to the position of maximum pressure in the focal region diverged from the value with element diameter < λ /2; values for piston-like elements increased positively whilst values for non piston-like elements increased negatively. With distances expressed in λ , no difference was found for arrays at 1 MHz and 2.5 MHz. For piston-like elements, but not for non piston-like elements, two peaks were found in the focal region which were in-line with the direction of propagation for a focus on the central axis but which rotated to become parallel with the direction of propagation when steering exceeded 20°. The size and position of the focal region under steering was similar for the non piston-like elements and elements with diameter < λ /2. Little difference was found in image quality or the size of the point spread function (PSF) between images at 2.5 MHz with piston-like and non piston-like behaviour for steering angles less than 20° when compared with a linear array of similar size. These results suggest that imaging with random arrays of millimetre length scale elements is possible.
- 27 July 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (10) , 1090-1099
Measurement and modelling the sensitivity of tetrapolar transfer impedance measurements
Finite element method (FEM) modelling of a small disk in a homogeneous saline medium showed that the sensitivity distribution for tetrapolar transfer impedance measurements was dependant on the ratio, σdisk/σsaline, and not absolute conductivity values. In addition, the amplitude of the negative sensitivity regions between the drive and receive electrodes decreased non-linearly with σdisk/σsaline for σdisk/σsaline < 1, eventually becoming zero. This non-linear behaviour determined the limit of the assumption of a small change in conductivity in Geselowitz's lead theorem with 0.5 <σdisk/σsaline <1.5 for the measurements reported. The modelling supported the design of a sensitivity measurement system using an insulating support and a metal disk in a saline filled tank. Measurements were shown to give good agreement with sensitivity predictions from Geselowitz's lead theorem. Replacing the homogeneous medium in the FEM model with layers of different conductivity parallel to the plane of the electrodes changed the sensitivity distribution when the thickness of the layers adjacent to the electrodes were less than ½ the electrode spacing. A layer of greater conductivity over a layer of lesser conductivity next to the electrodes gave a peak in the sensitivity distribution and extended regions of negative sensitivity further into the tissue.
- 27 July 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (10) , 1090-1099
Measurement and modelling the sensitivity of tetrapolar transfer impedance measurements
Finite element method (FEM) modelling of a small disk in a homogeneous saline medium showed that the sensitivity distribution for tetrapolar transfer impedance measurements was dependant on the ratio, σdisk/σsaline, and not absolute conductivity values. In addition, the amplitude of the negative sensitivity regions between the drive and receive electrodes decreased non-linearly with σdisk/σsaline for σdisk/σsaline < 1, eventually becoming zero. This non-linear behaviour determined the limit of the assumption of a small change in conductivity in Geselowitz's lead theorem with 0.5 <σdisk/σsaline <1.5 for the measurements reported. The modelling supported the design of a sensitivity measurement system using an insulating support and a metal disk in a saline filled tank. Measurements were shown to give good agreement with sensitivity predictions from Geselowitz's lead theorem. Replacing the homogeneous medium in the FEM model with layers of different conductivity parallel to the plane of the electrodes changed the sensitivity distribution when the thickness of the layers adjacent to the electrodes were less than ½ the electrode spacing. A layer of greater conductivity over a layer of lesser conductivity next to the electrodes gave a peak in the sensitivity distribution and extended regions of negative sensitivity further into the tissue.