Tamer Elnady
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tamer Elnady has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
Chokri Othmani
National School of Engineers of Sfax
4 shared publicationsHans Bodén
Royal Institute of Technology
4 shared publications- Wael Akl
Group for Advanced Research in Dynamic Systems (ASU-GARDS), Ain Shams University, 11517 Cairo, Egypt
4 shared publications Hans Boden
Royal Institute of Technology (KTH)
3 shared publications- Mats Åbom
The Marcus Wallenberg Lab., KTH-The Royal Inst of Technol., Teknikringen 8, Stockholm 10044, Sweden
3 shared publications Taissir Hentati
National School of Engineers of Sfax
3 shared publications
Latest Publications
- Open Access
- 12 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-20
Structural performance evaluation of electric vehicle chassis under static and dynamic loads
Electric vehicle (EV) production is pivotal in achieving environmental sustainability by reducing greenhouse gas emissions and air pollution. Since the weight of electric vehicles directly influences the energy consumption and driving range of the vehicle, innovative engineers face a significant challenge in designing an optimized vehicle chassis that remains robust under complex loading conditions. This paper focuses on the dynamic analysis of an EV chassis subjected to transient suspension forces due to hitting speed bumps and proposes a load factor between static and dynamic loads. A quarter vehicle model was adopted and solved using MATLAB Simulink to simulate the transient force transmitted to the chassis under different bump dimensions and vehicle speeds. The load was implemented into three different dynamic analysis studies: Front Loading, Rear Loading, and Torsional Loading. Subsequently, static and dynamic analyses were performed using Finite Element Analysis (FEA) with SimSolid software. The results obtained from the dynamic analysis studies showed that the maximum stress was 288 MPa with a safety factor of 1.12, while the maximum stress in the static analysis was 64 MPa with a safety factor of 5.69. Additionally, a load factor of 4.44 between static and dynamic loads was revealed. Based on these findings, the chassis experiences only elastic deformation and is considered safe for practical use.
- 12 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-20
Open AccessStructural performance evaluation of electric vehicle chassis under static and dynamic loads
Electric vehicle (EV) production is pivotal in achieving environmental sustainability by reducing greenhouse gas emissions and air pollution. Since the weight of electric vehicles directly influences the energy consumption and driving range of the vehicle, innovative engineers face a significant challenge in designing an optimized vehicle chassis that remains robust under complex loading conditions. This paper focuses on the dynamic analysis of an EV chassis subjected to transient suspension forces due to hitting speed bumps and proposes a load factor between static and dynamic loads. A quarter vehicle model was adopted and solved using MATLAB Simulink to simulate the transient force transmitted to the chassis under different bump dimensions and vehicle speeds. The load was implemented into three different dynamic analysis studies: Front Loading, Rear Loading, and Torsional Loading. Subsequently, static and dynamic analyses were performed using Finite Element Analysis (FEA) with SimSolid software. The results obtained from the dynamic analysis studies showed that the maximum stress was 288 MPa with a safety factor of 1.12, while the maximum stress in the static analysis was 64 MPa with a safety factor of 5.69. Additionally, a load factor of 4.44 between static and dynamic loads was revealed. Based on these findings, the chassis experiences only elastic deformation and is considered safe for practical use.
- Top Cited PapersOpen Access
- 2 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
Precise characterization of a corridor-shaped structure in Khufu’s Pyramid by observation of cosmic-ray muons
Khufu’s Pyramid is one of the largest archaeological monument all over the world, which still holds many mysteries. In 2016 and 2017, the ScanPyramids team reported on several discoveries of previously unknown voids by cosmic-ray muon radiography that is a non-destructive technique ideal for the investigation of large-scale structures. Among these discoveries, a corridor-shaped structure has been observed behind the so-called Chevron zone on the North face, with a length of at least 5 meters. A dedicated study of this structure was thus necessary to better understand its function in relation with the enigmatic architectural role of this Chevron. Here we report on new measurements of excellent sensitivity obtained with nuclear emulsion films from Nagoya University and gaseous detectors from CEA, revealing a structure of about 9 m length with a transverse section of about 2.0 m by 2.0 m.
- 2 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
Top Cited PapersOpen AccessPrecise characterization of a corridor-shaped structure in Khufu’s Pyramid by observation of cosmic-ray muons
Khufu’s Pyramid is one of the largest archaeological monument all over the world, which still holds many mysteries. In 2016 and 2017, the ScanPyramids team reported on several discoveries of previously unknown voids by cosmic-ray muon radiography that is a non-destructive technique ideal for the investigation of large-scale structures. Among these discoveries, a corridor-shaped structure has been observed behind the so-called Chevron zone on the North face, with a length of at least 5 meters. A dedicated study of this structure was thus necessary to better understand its function in relation with the enigmatic architectural role of this Chevron. Here we report on new measurements of excellent sensitivity obtained with nuclear emulsion films from Nagoya University and gaseous detectors from CEA, revealing a structure of about 9 m length with a transverse section of about 2.0 m by 2.0 m.
- Open Access
- 1 December 2018
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 9 (4) , 2725-2735
Production cost development for commercial exhaust systems
- 1 December 2018
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 9 (4) , 2725-2735
Open AccessProduction cost development for commercial exhaust systems
- 25 November 2017
- Published by Springer Nature
- p. 1149-1158
Investigation of Parameters Affecting the Acoustic Absorption Coefficient of Industrial Liners
- 25 November 2017
- Published by Springer Nature
- p. 1149-1158
Investigation of Parameters Affecting the Acoustic Absorption Coefficient of Industrial Liners
- 5 June 2017
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Measurement of Flow-Generated Noise inside Mufflers
Flow-generated noise has recently received a lot of attention within the process of designing exhaust and intake systems. Flow-generated noise can limit the amount of sound reduction a muffler can introduce inside ducts. This is more important in the modern system design where mufflers are compact and the flow speeds become higher in different sections inside the muffler. In this paper, three measurement techniques are used to measure the flow-generated noise from a duct element. The first is based on calculating the sound power levels inside a reverberation room according to ISO 3741. The radiated noise is measured from the muffler body as a source of noise, then from the tail pipe as an active one-port source. The second is based on sound power measurements inside the ducts using the active two-port theory. The third is measuring the sound pressure radiation inside an anechoic room. There has been a lot of work done to calculate the flow generated noise from simple duct elements but little has been published on full mufflers. In this paper, a compact muffler was studied. A 1D model based on the two-port theory was built for this muffler and whereas the flow-generation mechanisms were included in the active two-port formulation, and calculated using different scaling laws from literature for different duct elements such as orifices, pipes and open ends. Comparisons between simulations and measurements were performed to prove the reliability of the flow noise simulation technique.
- 5 June 2017
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Measurement of Flow-Generated Noise inside Mufflers
Flow-generated noise has recently received a lot of attention within the process of designing exhaust and intake systems. Flow-generated noise can limit the amount of sound reduction a muffler can introduce inside ducts. This is more important in the modern system design where mufflers are compact and the flow speeds become higher in different sections inside the muffler. In this paper, three measurement techniques are used to measure the flow-generated noise from a duct element. The first is based on calculating the sound power levels inside a reverberation room according to ISO 3741. The radiated noise is measured from the muffler body as a source of noise, then from the tail pipe as an active one-port source. The second is based on sound power measurements inside the ducts using the active two-port theory. The third is measuring the sound pressure radiation inside an anechoic room. There has been a lot of work done to calculate the flow generated noise from simple duct elements but little has been published on full mufflers. In this paper, a compact muffler was studied. A 1D model based on the two-port theory was built for this muffler and whereas the flow-generation mechanisms were included in the active two-port formulation, and calculated using different scaling laws from literature for different duct elements such as orifices, pipes and open ends. Comparisons between simulations and measurements were performed to prove the reliability of the flow noise simulation technique.
- 1 May 2017
- Published by Elsevier in Applied Acoustics
- Vol. 120, 90-97
Acoustic characterization of a porous absorber based on recycled sugarcane wastes
- 1 May 2017
- Published by Elsevier in Applied Acoustics
- Vol. 120, 90-97
Acoustic characterization of a porous absorber based on recycled sugarcane wastes
- 1 May 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (5_Suppleme) , 3614
Investigation of the effect of neglecting reflections in Power-based sound in ducts
In high frequency sound propagation inside ducts, the modal density is very high that the sound starts to propagate in rays. The acoustic performance of a duct network can be simulated using power-based models. The application of such situations is for HVAC systems and large silencers for power generation. Several standards are available for the analysis of HVAC systems using the same technique, such as ASHRAE and VDI. For each element, the flow-generated sound power inside the element is added to the input sound power and the output sound power is calculated by subtracting the Insertion Loss of the element. The attenuated sound energy can be either dissipated inside the element or reflected back to the system. Standards always assume that no energy is reflected and all the attenuation happens inside the element. This assumption is investigated in this paper. Several standard HVAC elements are considered, calculating the amount of energy dissipated inside the element and that reflected back. It was found that if all the reflected energy is considered, this will affect the output power from the system, especially in the highly reflective elements. The investigation was done using the Finite Element Method with the ray tracing technique.
- 1 May 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (5_Suppleme) , 3614
Investigation of the effect of neglecting reflections in Power-based sound in ducts
In high frequency sound propagation inside ducts, the modal density is very high that the sound starts to propagate in rays. The acoustic performance of a duct network can be simulated using power-based models. The application of such situations is for HVAC systems and large silencers for power generation. Several standards are available for the analysis of HVAC systems using the same technique, such as ASHRAE and VDI. For each element, the flow-generated sound power inside the element is added to the input sound power and the output sound power is calculated by subtracting the Insertion Loss of the element. The attenuated sound energy can be either dissipated inside the element or reflected back to the system. Standards always assume that no energy is reflected and all the attenuation happens inside the element. This assumption is investigated in this paper. Several standard HVAC elements are considered, calculating the amount of energy dissipated inside the element and that reflected back. It was found that if all the reflected energy is considered, this will affect the output power from the system, especially in the highly reflective elements. The investigation was done using the Finite Element Method with the ray tracing technique.
- 1 August 2016
- Published by Elsevier in Applied Acoustics
- Vol. 109, 44-53
Analysis of pipeline networks using two-ports
- 1 August 2016
- Published by Elsevier in Applied Acoustics
- Vol. 109, 44-53
Analysis of pipeline networks using two-ports
- 1 August 2016
- Published by Elsevier in Applied Acoustics
- Vol. 109, 90-96
Experimental and theoretical investigation of the acoustic performance of sugarcane wastes based material
- 1 August 2016
- Published by Elsevier in Applied Acoustics
- Vol. 109, 90-96
Experimental and theoretical investigation of the acoustic performance of sugarcane wastes based material
- 1 June 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 139 (6) , 3277-3287
Sound attenuation in ducts using locally resonant periodic aluminum patches
In recent years, the control of low frequency noise has received a lot of attention for several applications. Traditional passive noise control techniques using Helmholtz resonators have size limitations in the low frequency range because of the long wavelength. Promising noise reductions, with flush mounted aluminum patches with no size problems can be obtained using local resonance phenomenon implemented in acoustic metamaterial techniques. The objective of this work is to introduce locally resonant thin aluminum patches flush mounted to a duct walls aiming at creating frequency stop bands in a specific frequency range. Green's function is used within the framework of interface response theory to predict the amount of attenuation of the local resonant patches. The two-port theory and finite elements are also used to predict the acoustic performance of these patches. No flow measurements were conducted and show good agreement with the models. The effect of varying the damping and the masses of the patches are used to expand the stop bandwidth and the effect of both Bragg scattering and the locally resonant mechanisms was demonstrated using mathematical models. The effect of the arrays of patches on the effective dynamic density and bulk modulus has also been investigated.
- 1 June 2016
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 139 (6) , 3277-3287
Sound attenuation in ducts using locally resonant periodic aluminum patches
In recent years, the control of low frequency noise has received a lot of attention for several applications. Traditional passive noise control techniques using Helmholtz resonators have size limitations in the low frequency range because of the long wavelength. Promising noise reductions, with flush mounted aluminum patches with no size problems can be obtained using local resonance phenomenon implemented in acoustic metamaterial techniques. The objective of this work is to introduce locally resonant thin aluminum patches flush mounted to a duct walls aiming at creating frequency stop bands in a specific frequency range. Green's function is used within the framework of interface response theory to predict the amount of attenuation of the local resonant patches. The two-port theory and finite elements are also used to predict the acoustic performance of these patches. No flow measurements were conducted and show good agreement with the models. The effect of varying the damping and the masses of the patches are used to expand the stop bandwidth and the effect of both Bragg scattering and the locally resonant mechanisms was demonstrated using mathematical models. The effect of the arrays of patches on the effective dynamic density and bulk modulus has also been investigated.