Masaaki Ichiki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Masaaki Ichiki has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Takeshi Kobayashi
National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan
14 shared publications R. Maeda
National Institute of Advanced Industrial Science and Technology (Japan)
11 shared publicationsRyutaro Maeda
National Institute of Advanced Industrial Science and Technology (AIST)
11 shared publications- Yasushi Morikawa
Advancced Industrial Science and Technology
6 shared publications - Tadatomo Suga
Collaborative Research Center, Meisei University, Hino-shi, Tokyo 191-8506, Japan
5 shared publications Kazuhiro Nonaka
National Institute of Advanced Industrial Science and Technology (Japan)
4 shared publications
Latest Publications
- Open Access
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (4) , 495-502
Two-Axis Electromagnetic Scanner Using an Asymmetric Frame on a One-Axis Lateral Magnetic Field
Conventional electromagnetic microelectromechanical system scanners require a biaxial (two-axis) external magnetic field to obtain a biaxial torque, which increases the number of bulky external permanent magnets and the packaging size caused by 45 $^{\circ}$ -orientated placement of permanent magnets. Thus, this study developed a two-axis resonant electromagnetic scanner with an asymmetric gimbal frame that generates two-axis torque via a one-axis lateral external magnetic field. As external permanent magnets can be placed parallel to the device die, the proposed method reduced the packaging size. Two driving forces were generated by two independent electromagnetic actuators placed on both sides of the asymmetric gimbal frame, which converted the unidirectional forces into two-axis torque. As the two driving actuators were independent of the connecting beams, gimbal frame, and mirror and were connected to the thick outer Si handle frame, the temperature increase of torsion beams and the asymmetric gimbal frame, which affects the resonant performance, were reduced. Additionally, as the current paths were not multiturn coil shapes, the paths can be formed with a via-less single metal layer. Also, the drive circuit can be simplified since drive signals for two-axis rotation can be applied to individual actuators. We demonstrated biaxial scanning using the proposed structure with a 4-mm mirror. The optical scanning angle was 4.84 $^{\circ}$ for the 1.308 kHz X-axis scan and 16.1 $^{\circ}$ for the 2.568 kHz Y-axis scan when a current of 300 mA was applied independently to the X-and Y-axes driving actuators. We obtained the large displacement at the resonant frequency using the asymmetric gimbal frame under a lateral magnetic field. 2024-0050
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (4) , 495-502
Open AccessTwo-Axis Electromagnetic Scanner Using an Asymmetric Frame on a One-Axis Lateral Magnetic Field
Conventional electromagnetic microelectromechanical system scanners require a biaxial (two-axis) external magnetic field to obtain a biaxial torque, which increases the number of bulky external permanent magnets and the packaging size caused by 45 $^{\circ}$ -orientated placement of permanent magnets. Thus, this study developed a two-axis resonant electromagnetic scanner with an asymmetric gimbal frame that generates two-axis torque via a one-axis lateral external magnetic field. As external permanent magnets can be placed parallel to the device die, the proposed method reduced the packaging size. Two driving forces were generated by two independent electromagnetic actuators placed on both sides of the asymmetric gimbal frame, which converted the unidirectional forces into two-axis torque. As the two driving actuators were independent of the connecting beams, gimbal frame, and mirror and were connected to the thick outer Si handle frame, the temperature increase of torsion beams and the asymmetric gimbal frame, which affects the resonant performance, were reduced. Additionally, as the current paths were not multiturn coil shapes, the paths can be formed with a via-less single metal layer. Also, the drive circuit can be simplified since drive signals for two-axis rotation can be applied to individual actuators. We demonstrated biaxial scanning using the proposed structure with a 4-mm mirror. The optical scanning angle was 4.84 $^{\circ}$ for the 1.308 kHz X-axis scan and 16.1 $^{\circ}$ for the 2.568 kHz Y-axis scan when a current of 300 mA was applied independently to the X-and Y-axes driving actuators. We obtained the large displacement at the resonant frequency using the asymmetric gimbal frame under a lateral magnetic field. 2024-0050
- 1 September 2023
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (9) , 090901
Material identification and imaging of microplastics when dispersed in water using near-infrared light toward combination with a flow cell
The Earth’s environment and the health of living things are being negatively impacted by the microplastics in the oceans. We have studied a material identification method that could be performed using NIR light when the microplastics are inside water. The method is developed toward combining a flow cell to reduce the processes of drying and manually placing the microplastics in a measurement setup. The correlation coefficient was used to identify the material by comparing the absorbance spectrum with the reference data of polyethylene, polypropylene, polystyrene, and polymethyl methacrylate. The sizes, shapes, and materials of the microplastics were successfully identified.
- 1 September 2023
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (9) , 090901
Material identification and imaging of microplastics when dispersed in water using near-infrared light toward combination with a flow cell
The Earth’s environment and the health of living things are being negatively impacted by the microplastics in the oceans. We have studied a material identification method that could be performed using NIR light when the microplastics are inside water. The method is developed toward combining a flow cell to reduce the processes of drying and manually placing the microplastics in a measurement setup. The correlation coefficient was used to identify the material by comparing the absorbance spectrum with the reference data of polyethylene, polypropylene, polystyrene, and polymethyl methacrylate. The sizes, shapes, and materials of the microplastics were successfully identified.
- Open Access
- 4 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (5) , 830-839
Thermal Flow Sensor With a Bidirectional Thermal Reference
Conventional thermal flow sensors require samples to be heated; however, the temperature rise of the measuring tools limits their use in biological applications. To address this limitation, in this study, we propose a thermal flow sensor with a bidirectional thermal reference. We fabricated an integrated calorimetric and hot-film thermal flow sensor with a bidirectional thermal reference using a Peltier module to produce a thermal distribution that depends on the flow rate. The integrated thermal flow sensors enable high-resolution and wide-range flow rate measurements in a microfluidic device without the use of heating reagents in the cooling measurement mode. In addition, the sensor can be used as a typical heating thermal flow sensor by inverting the current applied to the Peltier module. Computational fluid dynamics simulations and experiments were performed to evaluate the performance of the integrated sensors in heating and cooling modes. In both modes, the calorimetric sensor measured low flow rates with a resolution of 100 nL/min, whereas the hot-film sensor measured a wide range of flow rates up to 200 $\mu \text{L}$ /min. The proposed sensor expands the use of the thermal flow sensors by switching between the cooling and heating modes according to the sample temperature and maximum temperature limit. [2022-0090]
- 4 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (5) , 830-839
Open AccessThermal Flow Sensor With a Bidirectional Thermal Reference
Conventional thermal flow sensors require samples to be heated; however, the temperature rise of the measuring tools limits their use in biological applications. To address this limitation, in this study, we propose a thermal flow sensor with a bidirectional thermal reference. We fabricated an integrated calorimetric and hot-film thermal flow sensor with a bidirectional thermal reference using a Peltier module to produce a thermal distribution that depends on the flow rate. The integrated thermal flow sensors enable high-resolution and wide-range flow rate measurements in a microfluidic device without the use of heating reagents in the cooling measurement mode. In addition, the sensor can be used as a typical heating thermal flow sensor by inverting the current applied to the Peltier module. Computational fluid dynamics simulations and experiments were performed to evaluate the performance of the integrated sensors in heating and cooling modes. In both modes, the calorimetric sensor measured low flow rates with a resolution of 100 nL/min, whereas the hot-film sensor measured a wide range of flow rates up to 200 $\mu \text{L}$ /min. The proposed sensor expands the use of the thermal flow sensors by switching between the cooling and heating modes according to the sample temperature and maximum temperature limit. [2022-0090]
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 967-970
Via-Less Two-Axis Electromagnetic Scanner Using An Asymmetric Frame On A One-Axis Lateral Magnetic Field
We developed a two-axis resonant electromagnetic scanner having an asymmetric frame that generates two-axis torques from a one-axis lateral external magnetic field. Two driving forces are generated by two independent electromagnetic actuators placed at both sides of the asymmetric frame, and the frame converts the one-directional forces into two-axis torques. As the two driving actuators are independent, driving current paths are isolated, and the proposed device also meets the other criteria: via-less single-metal-layer fabrication and no current path on the mirror part. We demonstrated biaxial scanning with the proposed structure having a 4-mm mirror. The optical scanning angle was 16.1° for the 1.308 kHz X-axis scan and 4.84° for the 2.568 kHz Y-axis scan when the currents of 300 mA were applied to the X-axis and Y-axis driving actuators independently.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 967-970
Via-Less Two-Axis Electromagnetic Scanner Using An Asymmetric Frame On A One-Axis Lateral Magnetic Field
We developed a two-axis resonant electromagnetic scanner having an asymmetric frame that generates two-axis torques from a one-axis lateral external magnetic field. Two driving forces are generated by two independent electromagnetic actuators placed at both sides of the asymmetric frame, and the frame converts the one-directional forces into two-axis torques. As the two driving actuators are independent, driving current paths are isolated, and the proposed device also meets the other criteria: via-less single-metal-layer fabrication and no current path on the mirror part. We demonstrated biaxial scanning with the proposed structure having a 4-mm mirror. The optical scanning angle was 16.1° for the 1.308 kHz X-axis scan and 4.84° for the 2.568 kHz Y-axis scan when the currents of 300 mA were applied to the X-axis and Y-axis driving actuators independently.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 527-530
Pattern Reconfigurable Ultrasonic Sound Source Using Laser-Induced Graphene Interdigitated Electrodes
We realized a pattern reconfigurable ultrasonic sound source using laser-induced graphene (LIG). In the proposed device, interdigitated electrodes composed of LIG are patterned on a polyimide film. By placing a conductive material on the device's backside, the current is transmitted only in the contact area using the capacitance coupling between the film and the conductive material. While conventional thermoacoustic sound sources cannot change an active LIG area without remaking, the proposed device can reconfigure the active area only by changing the pattern of the conductive material. We confirmed turning on the sound pressure emission from the fabricated device when placing an aluminum block as the conductive material. The sound pressure emitted by the device is maximized at 50 kHz. The results indicate that the device is helpful for pattern optimization for ultrasonic sound directivity.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 527-530
Pattern Reconfigurable Ultrasonic Sound Source Using Laser-Induced Graphene Interdigitated Electrodes
We realized a pattern reconfigurable ultrasonic sound source using laser-induced graphene (LIG). In the proposed device, interdigitated electrodes composed of LIG are patterned on a polyimide film. By placing a conductive material on the device's backside, the current is transmitted only in the contact area using the capacitance coupling between the film and the conductive material. While conventional thermoacoustic sound sources cannot change an active LIG area without remaking, the proposed device can reconfigure the active area only by changing the pattern of the conductive material. We confirmed turning on the sound pressure emission from the fabricated device when placing an aluminum block as the conductive material. The sound pressure emitted by the device is maximized at 50 kHz. The results indicate that the device is helpful for pattern optimization for ultrasonic sound directivity.
- Open Access
Mask-Type Sensor for Pulse Wave and Respiration Measurements and Eye Blink Detection
This paper reports on a mask-type sensor for simultaneous pulse wave and respiration measurements and eye blink detection that uses only one sensing element. In the proposed sensor, a flexible air bag-shaped chamber whose inner pressure change can be measured by a microelectromechanical system-based piezoresistive cantilever was used as the sensing element. The air bag-shaped chamber is fabricated by wrapping a sponge pad with plastic film and polyimide tape. The polyimide tape has a hole to which the substrate with the piezoresistive cantilever adheres. By attaching the sensor device to a mask where it contacts the nose of the subject, the sensor can detect the pulses and eye blinks of the subject by detecting the vibration and displacement of the nose skin caused by these physiological parameters. Moreover, the respiration of the subject causes pressure changes in the space between the mask and the face of the subject as well as slight vibrations of the mask. Therefore, information about the respiration of the subject can be extracted from the sensor signal using either the low-frequency component (100 Hz). This paper describes the sensor fabrication and provides demonstrations of the pulse wave and respiration measurements as well as eye blink detection using the fabricated sensor.
Open AccessMask-Type Sensor for Pulse Wave and Respiration Measurements and Eye Blink Detection
This paper reports on a mask-type sensor for simultaneous pulse wave and respiration measurements and eye blink detection that uses only one sensing element. In the proposed sensor, a flexible air bag-shaped chamber whose inner pressure change can be measured by a microelectromechanical system-based piezoresistive cantilever was used as the sensing element. The air bag-shaped chamber is fabricated by wrapping a sponge pad with plastic film and polyimide tape. The polyimide tape has a hole to which the substrate with the piezoresistive cantilever adheres. By attaching the sensor device to a mask where it contacts the nose of the subject, the sensor can detect the pulses and eye blinks of the subject by detecting the vibration and displacement of the nose skin caused by these physiological parameters. Moreover, the respiration of the subject causes pressure changes in the space between the mask and the face of the subject as well as slight vibrations of the mask. Therefore, information about the respiration of the subject can be extracted from the sensor signal using either the low-frequency component (100 Hz). This paper describes the sensor fabrication and provides demonstrations of the pulse wave and respiration measurements as well as eye blink detection using the fabricated sensor.
- 1 February 2021
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 141 (2) , 39-43
Transfer of Ferroelectric Thin Film Capacitor Using Internal Stress of Plated Film
The purpose of this article is for the establish of the releasing technologies of ferroelectric thin film capacitors using the internal stress of plated film. The stress analysis in simulation and the confirmation of experiment was carried out. As a result, it was demonstrated that the thin film capacitor can be actually released off. It was also confirmed that the performance as a capacitor after releasing was also good for the expected application.
- 1 February 2021
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 141 (2) , 39-43
Transfer of Ferroelectric Thin Film Capacitor Using Internal Stress of Plated Film
The purpose of this article is for the establish of the releasing technologies of ferroelectric thin film capacitors using the internal stress of plated film. The stress analysis in simulation and the confirmation of experiment was carried out. As a result, it was demonstrated that the thin film capacitor can be actually released off. It was also confirmed that the performance as a capacitor after releasing was also good for the expected application.
- Open Access
MEMS-Based Pulse Wave Sensor Utilizing a Piezoresistive Cantilever
This paper reports on a microelectromechanical systems (MEMS)-based sensor for pulse wave measurement. The sensor consists of an air chamber with a thin membrane and a 300-nm thick piezoresistive cantilever placed inside the chamber. When the membrane of the chamber is in contact with the skin above a vessel of a subject, the pulse wave of the subject causes the membrane to deform, leading to a change in the chamber pressure. This pressure change results in bending of the cantilever and change in the resistance of the cantilever, hence the pulse wave of the subject can be measured by monitoring the resistance of the cantilever. In this paper, we report the sensor design and fabrication, and demonstrate the measurement of the pulse wave using the fabricated sensor. Finally, measurement of the pulse wave velocity (PWV) is demonstrated by simultaneously measuring pulse waves at two points using the two fabricated sensor devices. Furthermore, the effect of breath holding on PWV is investigated. We showed that the proposed sensor can be used to continuously measure the PWV for each pulse, which indicates the possibility of using the sensor for continuous blood pressure measurement.
Open AccessMEMS-Based Pulse Wave Sensor Utilizing a Piezoresistive Cantilever
This paper reports on a microelectromechanical systems (MEMS)-based sensor for pulse wave measurement. The sensor consists of an air chamber with a thin membrane and a 300-nm thick piezoresistive cantilever placed inside the chamber. When the membrane of the chamber is in contact with the skin above a vessel of a subject, the pulse wave of the subject causes the membrane to deform, leading to a change in the chamber pressure. This pressure change results in bending of the cantilever and change in the resistance of the cantilever, hence the pulse wave of the subject can be measured by monitoring the resistance of the cantilever. In this paper, we report the sensor design and fabrication, and demonstrate the measurement of the pulse wave using the fabricated sensor. Finally, measurement of the pulse wave velocity (PWV) is demonstrated by simultaneously measuring pulse waves at two points using the two fabricated sensor devices. Furthermore, the effect of breath holding on PWV is investigated. We showed that the proposed sensor can be used to continuously measure the PWV for each pulse, which indicates the possibility of using the sensor for continuous blood pressure measurement.
- Open Access
MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate
The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are highly desired. Accordingly, a device that can measure multiple vital signs simultaneously using a single sensing element is important in order to reduce the number of devices attached to the wearer’s body, thereby reducing user discomfort. Thus, in this study, we propose a device with a microelectromechanical systems (MEMS)-based pressure sensor that can simultaneously measure the blood pulse wave and respiration rate using only one sensing element. In particular, in the proposed device, a thin silicone tube, whose inner pressure can be measured via a piezoresistive cantilever, is attached to the nose pad of a pair of eyeglasses. On wearing the eyeglasses, the tube of sensor device is in contact with the area above the angular artery and nasal cavity of the subject, and thus, both pulse wave and breath of the subject cause the tube’s inner pressure to change. We experimentally show that it is possible to extract information related to pulse wave and respiration as the low-frequency and high-frequency components of the sensor signal, respectively.
Open AccessMEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate
The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are highly desired. Accordingly, a device that can measure multiple vital signs simultaneously using a single sensing element is important in order to reduce the number of devices attached to the wearer’s body, thereby reducing user discomfort. Thus, in this study, we propose a device with a microelectromechanical systems (MEMS)-based pressure sensor that can simultaneously measure the blood pulse wave and respiration rate using only one sensing element. In particular, in the proposed device, a thin silicone tube, whose inner pressure can be measured via a piezoresistive cantilever, is attached to the nose pad of a pair of eyeglasses. On wearing the eyeglasses, the tube of sensor device is in contact with the area above the angular artery and nasal cavity of the subject, and thus, both pulse wave and breath of the subject cause the tube’s inner pressure to change. We experimentally show that it is possible to extract information related to pulse wave and respiration as the low-frequency and high-frequency components of the sensor signal, respectively.
- Open Access
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2017, 519
Driving tests of acceleration monitoring system due to vibration power generation using the vibration of air compressor
The necessity for the development of micro power supply technologies for mobile phones and portable electronics has increased in recent years. Methods of self power generation using the vibration loads of structures have attracted attention as the power supply technologies. In this study, we focused on lead zirconate titanate (Pb(Zr,Ti)O3, PZT) as the generating piezoelectric element. The purpose of the study isto develop a high-efficiency PZT generator element that utilizes the vibration loads in the support members of a structure. However, piezoelectric elements only generate power in the order of several microwatts, so improving their power generation capacity is of the utmost importance. In this paper, experiments of driving the accelerometer module using the laminated PZT elements under vibration loads of air compressor are reported. Acceleration monitoring system was composed of capacitor, switching circuit, voltage sensor and accelerometer module. The charges generated from the laminated PZT element are charged by the capacitor. And it reaches to the accelerometer module through the switching circuit. To show the laminated PZT element as an effective electric power source, this experiment has driven the accelerometer module with two batteries. As a result, it is possible to obtain the acceleration information, and the laminated PZT generated an electric power for driving the acceleration module by using the vibration of the air compressor. And by driving the battery, it was shown that the laminated of PZT element is effort of a electric power supply method. In this experiment, Receivable distance of the data has been evaluated. Based on these results, the laminated PZT can be applied to monitoring sensor and other applications.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2017, 519
Open AccessDriving tests of acceleration monitoring system due to vibration power generation using the vibration of air compressor
The necessity for the development of micro power supply technologies for mobile phones and portable electronics has increased in recent years. Methods of self power generation using the vibration loads of structures have attracted attention as the power supply technologies. In this study, we focused on lead zirconate titanate (Pb(Zr,Ti)O3, PZT) as the generating piezoelectric element. The purpose of the study isto develop a high-efficiency PZT generator element that utilizes the vibration loads in the support members of a structure. However, piezoelectric elements only generate power in the order of several microwatts, so improving their power generation capacity is of the utmost importance. In this paper, experiments of driving the accelerometer module using the laminated PZT elements under vibration loads of air compressor are reported. Acceleration monitoring system was composed of capacitor, switching circuit, voltage sensor and accelerometer module. The charges generated from the laminated PZT element are charged by the capacitor. And it reaches to the accelerometer module through the switching circuit. To show the laminated PZT element as an effective electric power source, this experiment has driven the accelerometer module with two batteries. As a result, it is possible to obtain the acceleration information, and the laminated PZT generated an electric power for driving the acceleration module by using the vibration of the air compressor. And by driving the battery, it was shown that the laminated of PZT element is effort of a electric power supply method. In this experiment, Receivable distance of the data has been evaluated. Based on these results, the laminated PZT can be applied to monitoring sensor and other applications.