Noé Demesa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Noé Demesa has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Armando Huicochea
Universidad Autónoma del Estado de Morelos
5 shared publications J. Siqueiros
3 shared publicationsJ.A. Hernández
3 shared publications- Juan Manuel Belman Flores
Grupo de Investigación IRSE, Departamento de Ingeniería Mecánica, División de Ingenierías, Campus Irapuato-Salamanca, Universidad de Guanajuato, Salamanca-Valle de Santiago km. 3.5+1.8, Salamanca C.P. 36885, Guanajuato, Mexico
3 shared publications - Juan Serrano-Arellano
División de Estudios de Posgrado e Investigación, Tecnológico Nacional de México, Instituto Tecnológico de Pachuca, Carretera México-Pachuca Km. 87.5, Colonia Venta Prieta, Pachuca de Soto 42080, Mexico
3 shared publications J.A. Hernandez
2 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by MDPI AG in Preprints.org
Numerical Study and Improvement of a Directional Thermal Decoupling Strategy for High-Capacity Pouch-Type Lithium-Ion Battery Modules
The sustained increase in energy density in lithium-ion battery modules requires robust thermal management strategies to mitigate excessive heat accumulation. In this study, a directional thermal decoupling strategy is systematically evaluated in an 8S2P module comprising 60 Ah pouch cells by implementing a three-dimensional coupled electrochemical–thermal conjugate framework. Under continuous 2C discharge at an elevated ambient temperature, five inter-cell insulation sheets and five lateral thermal interface materials coupled to serpentine cold plates are comparatively evaluated. Nanoporous aerogel-like barriers limit heat conduction along the stacking direction but significantly hinder lateral diffusion toward the module edges, raising the maximum temperature to between 332.5 and 333.7 K and the temperature difference to 13.5 K, while yielding lower heat rejection rates ranging from 169.8 to 171.7 W. Conversely, anisotropic graphite sheets enhance in-plane heat spreading, reduce maximum volumetric heat generation, decrease maximum temperature to 322.3K, and raise Q˙rej to 187.0W. At the lateral interface, a conformable AlN/PDMS composite minimizes conductive resistance, yielding an optimal heat rejection rate of 188.94 W and maintaining maximum temperature at 321.97K. These findings establish quantitative design criteria to effectively balance inter-cell thermal isolation with active heat evacuation under severe nominal operating regimes.
- 20 October 2026
- Published by MDPI AG in Preprints.org
Open AccessNumerical Study and Improvement of a Directional Thermal Decoupling Strategy for High-Capacity Pouch-Type Lithium-Ion Battery Modules
The sustained increase in energy density in lithium-ion battery modules requires robust thermal management strategies to mitigate excessive heat accumulation. In this study, a directional thermal decoupling strategy is systematically evaluated in an 8S2P module comprising 60 Ah pouch cells by implementing a three-dimensional coupled electrochemical–thermal conjugate framework. Under continuous 2C discharge at an elevated ambient temperature, five inter-cell insulation sheets and five lateral thermal interface materials coupled to serpentine cold plates are comparatively evaluated. Nanoporous aerogel-like barriers limit heat conduction along the stacking direction but significantly hinder lateral diffusion toward the module edges, raising the maximum temperature to between 332.5 and 333.7 K and the temperature difference to 13.5 K, while yielding lower heat rejection rates ranging from 169.8 to 171.7 W. Conversely, anisotropic graphite sheets enhance in-plane heat spreading, reduce maximum volumetric heat generation, decrease maximum temperature to 322.3K, and raise Q˙rej to 187.0W. At the lateral interface, a conformable AlN/PDMS composite minimizes conductive resistance, yielding an optimal heat rejection rate of 188.94 W and maintaining maximum temperature at 321.97K. These findings establish quantitative design criteria to effectively balance inter-cell thermal isolation with active heat evacuation under severe nominal operating regimes.
- Open Access
- 9 October 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (20) , 10280
From Traditional Passive Design to Artificial Intelligence-Based Optimization: A Systematic Review of Passive Design in Residential Buildings
Buildings account for a significant share of global energy consumption and greenhouse gas emissions, highlighting the importance of passive design strategies for improving residential energy efficiency and thermal comfort. This systematic review, conducted and reported in accordance with PRISMA 2020, examines the evolution of passive residential design from bioclimatic principles toward building energy simulation, computational optimization, and artificial intelligence (AI). A total of 191 studies were included in the systematic evidence synthesis. The reviewed evidence identifies orientation, insulation, glazing properties, window-to-wall ratio, shading, thermal mass, and ventilation as recurrent design variables influencing residential energy and thermal performance. The literature also reveals a methodological transition from the evaluation of individual passive strategies toward integrated computational frameworks combining building-performance simulation, predictive modeling, and multi-objective optimization. Validation or verification was explicitly reported in 72 of the 191 studies (37.7%), highlighting an important methodological limitation in the transferability of simulation- and AI-derived results. Methodological heterogeneity, climatic uncertainty, occupant behavior, and restricted transferability across climatic and construction contexts also remain important challenges. Overall, the evidence indicates that AI can complement rather than replace the physical principles of passive design by supporting prediction, design-space exploration, and optimization. From an engineering perspective, the findings support a hierarchical workflow in which passive variables guide early design decisions, simulation evaluates their interactions, multi-objective optimization explores performance trade-offs, and AI or surrogate models provide decision support only after adequate validation for the specific climate and building context.
- 9 October 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (20) , 10280
Open AccessFrom Traditional Passive Design to Artificial Intelligence-Based Optimization: A Systematic Review of Passive Design in Residential Buildings
Buildings account for a significant share of global energy consumption and greenhouse gas emissions, highlighting the importance of passive design strategies for improving residential energy efficiency and thermal comfort. This systematic review, conducted and reported in accordance with PRISMA 2020, examines the evolution of passive residential design from bioclimatic principles toward building energy simulation, computational optimization, and artificial intelligence (AI). A total of 191 studies were included in the systematic evidence synthesis. The reviewed evidence identifies orientation, insulation, glazing properties, window-to-wall ratio, shading, thermal mass, and ventilation as recurrent design variables influencing residential energy and thermal performance. The literature also reveals a methodological transition from the evaluation of individual passive strategies toward integrated computational frameworks combining building-performance simulation, predictive modeling, and multi-objective optimization. Validation or verification was explicitly reported in 72 of the 191 studies (37.7%), highlighting an important methodological limitation in the transferability of simulation- and AI-derived results. Methodological heterogeneity, climatic uncertainty, occupant behavior, and restricted transferability across climatic and construction contexts also remain important challenges. Overall, the evidence indicates that AI can complement rather than replace the physical principles of passive design by supporting prediction, design-space exploration, and optimization. From an engineering perspective, the findings support a hierarchical workflow in which passive variables guide early design decisions, simulation evaluates their interactions, multi-objective optimization explores performance trade-offs, and AI or surrogate models provide decision support only after adequate validation for the specific climate and building context.
- Open Access
- 18 June 2026
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 17 (6) , 316
A Review of the Thermal Management System of Lithium-Ion Batteries in Electric Vehicles According to the Classification of Phase Change Materials
Thermal regulation of lithium-ion (Li-ion) battery modules is a critical constraint for electric vehicle (EV) safety and durability, particularly during high-C-rate operation. Phase change materials (PCMs) have emerged as promising passive solutions due to their latent heat storage capability; however, current literature is heavily biased toward organic paraffin-based systems and lacks structured benchmarking across PCM categories and integration architectures. This review provides a systematic comparative assessment of PCM-based battery thermal management systems (BTMSs) comprising organic, inorganic, and eutectic materials under EV-relevant discharge conditions. The review is structured according to the conventional classification of PCMs; however, the available literature is predominantly focused on organic materials, particularly paraffin-based PCMs, leading to greater depth of analysis for this category. Thermophysical properties are analyzed in conjunction with discharge rate, module configuration, and hybrid cooling strategies. The results indicate that peak temperature mitigation is weakly correlated with latent heat magnitude when thermal conductivity remains below critical values. Conductivity-enhanced composites incorporating expanded graphite or metal foams significantly improve heat diffusion, reducing hotspot intensity and inter-cell temperature gradients under medium-to-high C-rates. Pure passive PCM systems exhibit thermodynamic limitations during sustained high-power operation due to saturation effects, underscoring the need for hybrid architectures for continuous heat rejection. This work establishes a structured benchmarking framework and demonstrates that effective thermal conductivity, integration strategy, and discharge-dependent design dominate BTMS performance over latent heat alone. The findings also reveal that inorganic and eutectic PCM-based BTMSs remain comparatively less explored in the literature, particularly at the battery module level and under realistic electric vehicle operating conditions, highlighting opportunities for future research.
- 18 June 2026
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 17 (6) , 316
Open AccessA Review of the Thermal Management System of Lithium-Ion Batteries in Electric Vehicles According to the Classification of Phase Change Materials
Thermal regulation of lithium-ion (Li-ion) battery modules is a critical constraint for electric vehicle (EV) safety and durability, particularly during high-C-rate operation. Phase change materials (PCMs) have emerged as promising passive solutions due to their latent heat storage capability; however, current literature is heavily biased toward organic paraffin-based systems and lacks structured benchmarking across PCM categories and integration architectures. This review provides a systematic comparative assessment of PCM-based battery thermal management systems (BTMSs) comprising organic, inorganic, and eutectic materials under EV-relevant discharge conditions. The review is structured according to the conventional classification of PCMs; however, the available literature is predominantly focused on organic materials, particularly paraffin-based PCMs, leading to greater depth of analysis for this category. Thermophysical properties are analyzed in conjunction with discharge rate, module configuration, and hybrid cooling strategies. The results indicate that peak temperature mitigation is weakly correlated with latent heat magnitude when thermal conductivity remains below critical values. Conductivity-enhanced composites incorporating expanded graphite or metal foams significantly improve heat diffusion, reducing hotspot intensity and inter-cell temperature gradients under medium-to-high C-rates. Pure passive PCM systems exhibit thermodynamic limitations during sustained high-power operation due to saturation effects, underscoring the need for hybrid architectures for continuous heat rejection. This work establishes a structured benchmarking framework and demonstrates that effective thermal conductivity, integration strategy, and discharge-dependent design dominate BTMS performance over latent heat alone. The findings also reveal that inorganic and eutectic PCM-based BTMSs remain comparatively less explored in the literature, particularly at the battery module level and under realistic electric vehicle operating conditions, highlighting opportunities for future research.
- Open Access
Experimental Investigation of a Miniature Refrigeration System Using R134a and a Low GWP Blend R515B
Miniature vapor compression refrigeration systems are gaining increasing relevance in cutting-edge applications such as drone docking station cooling, electric vehicle battery thermal management, portable medical and diagnostic devices, compact beverage dispensers, field-mounted telecom cabinet cooling, as well as the already established fields of electronics and personal cooling. These systems offer a promising pathway to localized and mobile cooling solutions. When coupled with the implementation of alternative low-GWP refrigerants that match or even enhance system performance, the result is a more efficient, environmentally responsible, and potentially sustainable refrigeration technology. Therefore, this study experimentally evaluates the performance of R515B as a low-GWP drop-in replacement for R134a in a miniature vapor compression refrigeration system. Key parameters were analyzed to determine the most suitable operating conditions, resulting in a capillary length of 1.25 m, refrigerant charge of 110 g, compressor speed of 4500 rpm, and high condenser fan speed, under which R515B achieved a COP of 5.16 and a cooling capacity of 252.20 W, representing improvements of 38% and 6.5%, respectively, compared to R134a. These results confirm the viability of R515B as an efficient, environmentally friendly alternative for miniature small-scale vapor compression systems.
Open AccessExperimental Investigation of a Miniature Refrigeration System Using R134a and a Low GWP Blend R515B
Miniature vapor compression refrigeration systems are gaining increasing relevance in cutting-edge applications such as drone docking station cooling, electric vehicle battery thermal management, portable medical and diagnostic devices, compact beverage dispensers, field-mounted telecom cabinet cooling, as well as the already established fields of electronics and personal cooling. These systems offer a promising pathway to localized and mobile cooling solutions. When coupled with the implementation of alternative low-GWP refrigerants that match or even enhance system performance, the result is a more efficient, environmentally responsible, and potentially sustainable refrigeration technology. Therefore, this study experimentally evaluates the performance of R515B as a low-GWP drop-in replacement for R134a in a miniature vapor compression refrigeration system. Key parameters were analyzed to determine the most suitable operating conditions, resulting in a capillary length of 1.25 m, refrigerant charge of 110 g, compressor speed of 4500 rpm, and high condenser fan speed, under which R515B achieved a COP of 5.16 and a cooling capacity of 252.20 W, representing improvements of 38% and 6.5%, respectively, compared to R134a. These results confirm the viability of R515B as an efficient, environmentally friendly alternative for miniature small-scale vapor compression systems.
- 5 August 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Experimental study of an absorber with bronze disks for an absorption heat transformer
- 5 August 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Experimental study of an absorber with bronze disks for an absorption heat transformer
- 9 December 2024
- Published by Wiley in Heat Transfer
- Vol. 54 (2) , 1691-1710
Numerical Analysis of the Heat and Mass Transfer in a Ventilated Cavity for Turbulent Convective Flow With Extreme Hot and Humid Climate Conditions
To analyze the temperature and relative humidity (RH) in a room located in the Lacandona jungle in Chiapas, Mexico, a numerical heat and mass transfer study was performed. The study was carried out in a ventilated cavity, by introducing air flow into user‐occupied spaces. The study analyzed the combination of temperature and humidity percentage to create thermal comfort conditions. The finite volume method was used to solve the governing equations, while pressure–velocity coupling was done with the SIMPLEC algorithm. Turbulent airflow was considered, and modeled using the k–ε turbulence model, with Reynolds numbers (Re) in the range from 100 to 5000. Seven sets of weather conditions were considered for a warm April day with solar radiation values that ranged from 0 to 981 W/m², outdoor temperatures between 19.9°C and 35.3°C, as well as RH from 42% up to 100%. The study analyzed temperature, RH, distribution efficiencies, and heat fluxes. It was found that the average temperature closest to thermal comfort was 25.8°C. This corresponds to an Re = 5000, being the best hygrothermal conditions with an average RH of 50%. However, this level of RH is unattainable by many air conditioning systems.
- 9 December 2024
- Published by Wiley in Heat Transfer
- Vol. 54 (2) , 1691-1710
Numerical Analysis of the Heat and Mass Transfer in a Ventilated Cavity for Turbulent Convective Flow With Extreme Hot and Humid Climate Conditions
To analyze the temperature and relative humidity (RH) in a room located in the Lacandona jungle in Chiapas, Mexico, a numerical heat and mass transfer study was performed. The study was carried out in a ventilated cavity, by introducing air flow into user‐occupied spaces. The study analyzed the combination of temperature and humidity percentage to create thermal comfort conditions. The finite volume method was used to solve the governing equations, while pressure–velocity coupling was done with the SIMPLEC algorithm. Turbulent airflow was considered, and modeled using the k–ε turbulence model, with Reynolds numbers (Re) in the range from 100 to 5000. Seven sets of weather conditions were considered for a warm April day with solar radiation values that ranged from 0 to 981 W/m², outdoor temperatures between 19.9°C and 35.3°C, as well as RH from 42% up to 100%. The study analyzed temperature, RH, distribution efficiencies, and heat fluxes. It was found that the average temperature closest to thermal comfort was 25.8°C. This corresponds to an Re = 5000, being the best hygrothermal conditions with an average RH of 50%. However, this level of RH is unattainable by many air conditioning systems.
- Open Access
- 30 June 2021
- Published by ECORFAN in Revista de Tecnologías en procesos Industriales
- p. 24-32
Potencial of energy saving in the fish and seafood cold storage in San Francisco de Campeche
The following paper focuses on energy efficiency applied to a company dedicated to the conservation and freezing of seafood products located in the city of San Francisco de Campeche, Camp, Mexico. For this, a theoretical study is carried out to determine the energy saving potential of one of the refrigeration systems currently installed in the company to fulfill the hypothesis of obtaining savings of up to 3% in energy consumption by reducing 1 °C the condensing temperature of the system. The main thermal loads of the system are Mayan octopus, shrimp, and fish (various). With the help of the Genetron Properties Software, the different calculations are carried out by making variations in the condensation and conservation temperatures, without varying the thermal load, but considering a correct and incorrect heat exchange of the condensing units with the outside.
- 30 June 2021
- Published by ECORFAN in Revista de Tecnologías en procesos Industriales
- p. 24-32
Open AccessPotencial of energy saving in the fish and seafood cold storage in San Francisco de Campeche
The following paper focuses on energy efficiency applied to a company dedicated to the conservation and freezing of seafood products located in the city of San Francisco de Campeche, Camp, Mexico. For this, a theoretical study is carried out to determine the energy saving potential of one of the refrigeration systems currently installed in the company to fulfill the hypothesis of obtaining savings of up to 3% in energy consumption by reducing 1 °C the condensing temperature of the system. The main thermal loads of the system are Mayan octopus, shrimp, and fish (various). With the help of the Genetron Properties Software, the different calculations are carried out by making variations in the condensation and conservation temperatures, without varying the thermal load, but considering a correct and incorrect heat exchange of the condensing units with the outside.
- Open Access
- 1 May 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (5) , 055103
Correlation between Raman spectra and color of tungsten trioxide (WO3) thermally evaporated from a tungsten filament
The color exhibited by tungsten trioxide (WO3) can be associated with both its stoichiometry and crystallinity. Correlation between the color exhibited by WO3 powders and their purity and crystalline properties is reported in this paper. The WO3 powders were deposited by evaporation of tungsten trioxide from the surface of a tungsten filament. The WO3 powders exhibited three different shades of blue: navy, royal, and sky. The color of the WO3 powders changed to white after thermal treatment at 500 °C for 30 min in an ambient atmosphere. Raman analyses showed that transition from amorphous to crystalline WO3 started when the powders exhibited navy-blue color and ended when WO3 powders exhibited a white color. Scanning electron microscopy analysis showed particle agglomeration characteristics in all WO3 powders, even after they were thermally treated. The mechanism of deposition of WO3 from the tungsten filament was suggested to be governed by thermal evaporation of tungsten trioxide from the surface of the oxidized tungsten filament.
- 1 May 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (5) , 055103
Open AccessCorrelation between Raman spectra and color of tungsten trioxide (WO3) thermally evaporated from a tungsten filament
The color exhibited by tungsten trioxide (WO3) can be associated with both its stoichiometry and crystallinity. Correlation between the color exhibited by WO3 powders and their purity and crystalline properties is reported in this paper. The WO3 powders were deposited by evaporation of tungsten trioxide from the surface of a tungsten filament. The WO3 powders exhibited three different shades of blue: navy, royal, and sky. The color of the WO3 powders changed to white after thermal treatment at 500 °C for 30 min in an ambient atmosphere. Raman analyses showed that transition from amorphous to crystalline WO3 started when the powders exhibited navy-blue color and ended when WO3 powders exhibited a white color. Scanning electron microscopy analysis showed particle agglomeration characteristics in all WO3 powders, even after they were thermally treated. The mechanism of deposition of WO3 from the tungsten filament was suggested to be governed by thermal evaporation of tungsten trioxide from the surface of the oxidized tungsten filament.
- 11 February 2020
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 34 (2) , 140-161
Experimental assessment of heat exchangers with nested helical coils for an absorption heat transformer
The studies of nested helical coil heat exchangers for an absorption heat transformer are very limited, although this arrangement has a greater heat transfer area in a smaller volume. The heat exchangers are vertically placed to develop the desorption, condensation, evaporation and absorption processes by falling film mode. The usage of energy from point of qualitative view in these times is mandatory, due to the fossil fuels reduction and pollution. This experimental study analyses the behavior the nested helical coils heat exchangers through the first and second law of thermodynamics. The physical and chemical exergy for the main components and whole system is calculated by using the conventional method. All the experimental tests are carried out by varying the source temperature from 343.15 to 358.15 K with heating mass flow rate in the generator between 0.07 and 0.13 kg/s. For this study, the condensation and absorption processes reach the highest exergy destruction at high temperatures, while the solution heat exchanger presents the lowest irreversibility. The exergy coefficient of performance always improves when the supplied heat in the generator increases owing to the heating mass flow rate and temperature, however there is an increment considerably of total irreversibility at 349.15 K.
- 11 February 2020
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 34 (2) , 140-161
Experimental assessment of heat exchangers with nested helical coils for an absorption heat transformer
The studies of nested helical coil heat exchangers for an absorption heat transformer are very limited, although this arrangement has a greater heat transfer area in a smaller volume. The heat exchangers are vertically placed to develop the desorption, condensation, evaporation and absorption processes by falling film mode. The usage of energy from point of qualitative view in these times is mandatory, due to the fossil fuels reduction and pollution. This experimental study analyses the behavior the nested helical coils heat exchangers through the first and second law of thermodynamics. The physical and chemical exergy for the main components and whole system is calculated by using the conventional method. All the experimental tests are carried out by varying the source temperature from 343.15 to 358.15 K with heating mass flow rate in the generator between 0.07 and 0.13 kg/s. For this study, the condensation and absorption processes reach the highest exergy destruction at high temperatures, while the solution heat exchanger presents the lowest irreversibility. The exergy coefficient of performance always improves when the supplied heat in the generator increases owing to the heating mass flow rate and temperature, however there is an increment considerably of total irreversibility at 349.15 K.
- 1 May 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 120, 342-349
Heat transfer coefficients for helical components inside an Absorption Heat Transformer
- 1 May 2018
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 120, 342-349
Heat transfer coefficients for helical components inside an Absorption Heat Transformer