Elizabeth. J. Legge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elizabeth. J. Legge has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Andrew John Pollard
National Physical Laboratory
5 shared publications - Natalie A. Belsey
Chemical and Biological Sciences Department, National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, UK
4 shared publications - Caterina Minelli
National Physical Laboratory, Hampton Road, Teddington, TW11 0LW, UK
3 shared publications - Barry Brennan
Atlantic Technological University Ash Lane F91 YW50 Sligo Ireland
2 shared publications - Cinzia Casiraghi
Department of Chemistry, University of Manchester, Manchester, M13 9PL, UK
2 shared publications - Dimitrios Tsikritsis
National Physical Laboratory , Hampton Road
2 shared publications
Latest Publications
- Open Access
- 11 March 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (13) , 2682-2691
Optimisation of through-vial Raman analysis of turbid samples by modelling the Raman intensity-depth decay response
Predicting Raman signal decay in particulate samples for optimised quantitative measurements.
- 11 March 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (13) , 2682-2691
Open AccessOptimisation of through-vial Raman analysis of turbid samples by modelling the Raman intensity-depth decay response
Predicting Raman signal decay in particulate samples for optimised quantitative measurements.
- Open Access
- 11 June 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (14) , 3077-3088
Benchmarking TERS and TEPL probes: towards a reference sample for quantification of near-field enhancement factors in gap and non-gap modes
A potential reference sample was developed for facile quantification of near-field Raman and photoluminescence contrast factors in gap and non-gap modes.
- 11 June 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (14) , 3077-3088
Open AccessBenchmarking TERS and TEPL probes: towards a reference sample for quantification of near-field enhancement factors in gap and non-gap modes
A potential reference sample was developed for facile quantification of near-field Raman and photoluminescence contrast factors in gap and non-gap modes.
- Open Access
- 3 January 2025
- Published by Royal Society of Chemistry (RSC) in RSC Pharmaceutics
- Vol. 2 (2) , 279-291
Non-invasive quantitative chemical measurements of liposomal formulations using Raman spectroscopy
Raman spectroscopy methods for quantitative chemical measurements of nanomedicines, applied to liposomal doxorubicin through the wall of a glass vial.
- 3 January 2025
- Published by Royal Society of Chemistry (RSC) in RSC Pharmaceutics
- Vol. 2 (2) , 279-291
Open AccessNon-invasive quantitative chemical measurements of liposomal formulations using Raman spectroscopy
Raman spectroscopy methods for quantitative chemical measurements of nanomedicines, applied to liposomal doxorubicin through the wall of a glass vial.
- Open Access
- 20 May 2024
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 113 (8) , 2464-2474
Advanced Chemical and Imaging Methods for Studying Structure Morphology and Excipients Solid State Transformations in Pharmaceutical Multiparticulate Formulations
- 20 May 2024
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 113 (8) , 2464-2474
Open AccessAdvanced Chemical and Imaging Methods for Studying Structure Morphology and Excipients Solid State Transformations in Pharmaceutical Multiparticulate Formulations
- Open Access
- 5 March 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
Crystallization of molecular layers produced under confinement onto a surface
It is well known that molecules confined very close to a surface arrange into molecular layers. Because solid-liquid interfaces are ubiquitous in the chemical, biological and physical sciences, it is crucial to develop methods to easily access molecular layers and exploit their distinct properties by producing molecular layered crystals. Here we report a method based on crystallization in ultra-thin puddles enabled by gas blowing, which allows to produce molecular layered crystals with thickness down to the monolayer onto a surface, making them directly accessible for characterization and further processing. By selecting four molecules with different types of polymorphs, we observed exclusive crystallization of polymorphs with Van der Waals interlayer interactions, which have not been observed with traditional confinement methods. In conclusion, the gas blowing approach unveils the opportunity to perform materials chemistry under confinement onto a surface, enabling the formation of distinct crystals with selected polymorphism.
- 5 March 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
Open AccessCrystallization of molecular layers produced under confinement onto a surface
It is well known that molecules confined very close to a surface arrange into molecular layers. Because solid-liquid interfaces are ubiquitous in the chemical, biological and physical sciences, it is crucial to develop methods to easily access molecular layers and exploit their distinct properties by producing molecular layered crystals. Here we report a method based on crystallization in ultra-thin puddles enabled by gas blowing, which allows to produce molecular layered crystals with thickness down to the monolayer onto a surface, making them directly accessible for characterization and further processing. By selecting four molecules with different types of polymorphs, we observed exclusive crystallization of polymorphs with Van der Waals interlayer interactions, which have not been observed with traditional confinement methods. In conclusion, the gas blowing approach unveils the opportunity to perform materials chemistry under confinement onto a surface, enabling the formation of distinct crystals with selected polymorphism.
- Open Access
- 16 August 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (21) , 4642-4656
Practical considerations for quantitative and reproducible measurements with stimulated Raman scattering microscopy
This tutorial review presents the most important practical considerations for sample preparation, instrument set-up, image acquisition and data analysis to obtain reproducible SRS measurements.
- 16 August 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (21) , 4642-4656
Open AccessPractical considerations for quantitative and reproducible measurements with stimulated Raman scattering microscopy
This tutorial review presents the most important practical considerations for sample preparation, instrument set-up, image acquisition and data analysis to obtain reproducible SRS measurements.
- 20 May 2022
- Published by IOP Publishing in 2D Materials
- Vol. 9 (3) , 035010
International interlaboratory comparison of Raman spectroscopic analysis of CVD-grown graphene
There is a pressing need for reliable, reproducible and accurate measurements of graphene’s properties, through international standards, to facilitate industrial growth. However, trustworthy and verified standards require rigorous metrological studies, determining, quantifying and reducing the sources of measurement uncertainty. Towards this effort, we report the procedure and the results of an international interlaboratory comparison (ILC) study, conducted under Versailles Project on Advanced Materials and Standards. This ILC focusses on the comparability of Raman spectroscopy measurements of chemical vapour deposition (CVD) grown graphene using the same measurement protocol across different institutes and laboratories. With data gathered from 17 participants across academia, industry (including instrument manufacturers) and national metrology institutes, this study investigates the measurement uncertainty contributions from both Raman spectroscopy measurements and data analysis procedures, as well as provides solutions for improved accuracy and precision. While many of the reported Raman metrics were relatively consistent, significant and meaningful outliers occurred due to differences in the instruments and data analysis. These variations resulted in inconsistent reports of peak intensity ratios, peak widths and the coverage of graphene. Due to a lack of relative intensity calibration, the relative difference reported in the 2D- and G peak intensity ratios ( I 2 D / I G ) was up to 200%. It was also shown that the standard deviation for Γ 2 D values reported by different software packages, was 15× larger for Lorentzian fit functions than for pseudo-Voigt functions. This study has shown that by adopting a relative intensity calibration and consistent peak fitting and data analysis methodologies, these large, and previously unquantified, variations can be significantly reduced, allowing more reproducible and comparable measurements for the graphene community, supporting fundamental research through to the growing graphene industry worldwide. This project and its findings directly underpin the development of the ISO/IEC standard ‘ DTS 21356-2—Nanotechnologies—Structural Characterisation of CVD-grown Graphene ’.
- 20 May 2022
- Published by IOP Publishing in 2D Materials
- Vol. 9 (3) , 035010
International interlaboratory comparison of Raman spectroscopic analysis of CVD-grown graphene
There is a pressing need for reliable, reproducible and accurate measurements of graphene’s properties, through international standards, to facilitate industrial growth. However, trustworthy and verified standards require rigorous metrological studies, determining, quantifying and reducing the sources of measurement uncertainty. Towards this effort, we report the procedure and the results of an international interlaboratory comparison (ILC) study, conducted under Versailles Project on Advanced Materials and Standards. This ILC focusses on the comparability of Raman spectroscopy measurements of chemical vapour deposition (CVD) grown graphene using the same measurement protocol across different institutes and laboratories. With data gathered from 17 participants across academia, industry (including instrument manufacturers) and national metrology institutes, this study investigates the measurement uncertainty contributions from both Raman spectroscopy measurements and data analysis procedures, as well as provides solutions for improved accuracy and precision. While many of the reported Raman metrics were relatively consistent, significant and meaningful outliers occurred due to differences in the instruments and data analysis. These variations resulted in inconsistent reports of peak intensity ratios, peak widths and the coverage of graphene. Due to a lack of relative intensity calibration, the relative difference reported in the 2D- and G peak intensity ratios ( I 2 D / I G ) was up to 200%. It was also shown that the standard deviation for Γ 2 D values reported by different software packages, was 15× larger for Lorentzian fit functions than for pseudo-Voigt functions. This study has shown that by adopting a relative intensity calibration and consistent peak fitting and data analysis methodologies, these large, and previously unquantified, variations can be significantly reduced, allowing more reproducible and comparable measurements for the graphene community, supporting fundamental research through to the growing graphene industry worldwide. This project and its findings directly underpin the development of the ISO/IEC standard ‘ DTS 21356-2—Nanotechnologies—Structural Characterisation of CVD-grown Graphene ’.
- 3 November 2021
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 155 (17) , 174703
Understanding the bonding mechanisms of organic molecules deposited on graphene for biosensing applications
Graphene is an ideal material for biosensors due to the large surface area for multiple bonding sites, the high electrical conductivity allowing for high sensitivity, and the high tensile strength providing durability in fabricated sensor devices. For graphene to be successful as a biosensing platform, selectivity must be achieved through functionalization with specific chemical groups. However, the device performance and sensor sensitivity must still be maintained after functionalization, which can be challenging. We compare phenyl amine and 1,5-diaminonaphthalene functionalization methods for chemical vapor deposition grown graphene, both used to obtain graphene modified with amine groups—which is required for surface attachment of highly selective antibody bio-receptors. Through atomic force microscopy (AFM), Raman spectroscopy, and time-of-flight secondary ion mass spectrometry imaging of co-located areas, the chemistry, thickness, and coverage of the functional groups bound to the graphene surface have been comprehensively analyzed. We demonstrate the modification of functionalized graphene using AFM, which unexpectedly suggests the removal of covalently bonded functional groups, resulting in a “recovered” graphene structure with reduced disorder, confirmed with Raman spectroscopy. This removal explains the decrease in the ID/IG ratio observed in Raman spectra from other studies on functionalized graphene after mechanical strain or a chemical reaction and reveals the possibility of reverting to the non-functionalized graphene structure. Through this study, preferred functionalization processes are recommended to maintain the performance properties of graphene as a biosensor.
- 3 November 2021
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 155 (17) , 174703
Understanding the bonding mechanisms of organic molecules deposited on graphene for biosensing applications
Graphene is an ideal material for biosensors due to the large surface area for multiple bonding sites, the high electrical conductivity allowing for high sensitivity, and the high tensile strength providing durability in fabricated sensor devices. For graphene to be successful as a biosensing platform, selectivity must be achieved through functionalization with specific chemical groups. However, the device performance and sensor sensitivity must still be maintained after functionalization, which can be challenging. We compare phenyl amine and 1,5-diaminonaphthalene functionalization methods for chemical vapor deposition grown graphene, both used to obtain graphene modified with amine groups—which is required for surface attachment of highly selective antibody bio-receptors. Through atomic force microscopy (AFM), Raman spectroscopy, and time-of-flight secondary ion mass spectrometry imaging of co-located areas, the chemistry, thickness, and coverage of the functional groups bound to the graphene surface have been comprehensively analyzed. We demonstrate the modification of functionalized graphene using AFM, which unexpectedly suggests the removal of covalently bonded functional groups, resulting in a “recovered” graphene structure with reduced disorder, confirmed with Raman spectroscopy. This removal explains the decrease in the ID/IG ratio observed in Raman spectra from other studies on functionalized graphene after mechanical strain or a chemical reaction and reveals the possibility of reverting to the non-functionalized graphene structure. Through this study, preferred functionalization processes are recommended to maintain the performance properties of graphene as a biosensor.
- Open Access
- 7 November 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (65) , 37540-37549
Physicochemical characterisation of reduced graphene oxide for conductive thin films
Graphene is a desirable material for next generation technology. However, producing high yields of single-layer flakes with industrially applicable methods is currently limited. We introduce a combined process for the reduction of graphene oxide (GO) via vitamin C (ascorbic acid) and thermal annealing at temperatures of −1, suitable for microelectronics, display technology and optoelectronic applications. The in-depth physicochemical characterisation of the products at different stages of GO preparation and reduction allows for further understanding of the process and demonstrates the suitability for industrial production methodologies due to an environmentally-friendly reducing agent, solution processability and no requirement for high temperatures. The presence of the vitamin C lowers the temperature required to thermally reduce the GO into an electrically conducting thin film, making the technique suitable for thermally sensitive substrates, such as low melting point polymers. Simultaneous spray coating and reduction of GO allows for large area deposition of conductive coatings without sacrificing solution processability, often lost through particle agglomeration, making it compatible with industrial processes, and applicable to, for example, the production of sensors, energy devices and flexible conductive electrodes for touchscreens.
- 7 November 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (65) , 37540-37549
Open AccessPhysicochemical characterisation of reduced graphene oxide for conductive thin films
Graphene is a desirable material for next generation technology. However, producing high yields of single-layer flakes with industrially applicable methods is currently limited. We introduce a combined process for the reduction of graphene oxide (GO) via vitamin C (ascorbic acid) and thermal annealing at temperatures of −1, suitable for microelectronics, display technology and optoelectronic applications. The in-depth physicochemical characterisation of the products at different stages of GO preparation and reduction allows for further understanding of the process and demonstrates the suitability for industrial production methodologies due to an environmentally-friendly reducing agent, solution processability and no requirement for high temperatures. The presence of the vitamin C lowers the temperature required to thermally reduce the GO into an electrically conducting thin film, making the technique suitable for thermally sensitive substrates, such as low melting point polymers. Simultaneous spray coating and reduction of GO allows for large area deposition of conductive coatings without sacrificing solution processability, often lost through particle agglomeration, making it compatible with industrial processes, and applicable to, for example, the production of sensors, energy devices and flexible conductive electrodes for touchscreens.