Sinan Gucluer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sinan Gucluer has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Adem Ozcelik
Department of Mechanical Engineering, Aydin Adnan Menderes University, Aydin 09010, Türkiye
5 shared publications - Fatih Akkoyun
İzmir Demokrasi Üniversitesi
2 shared publications A. Çakan
Abant Izzet Baysal University, Faculty of Eng. & Architecture, Bolu, Turkey
1 shared publication- Adnan Sözen
Gazi Üniversitesi
1 shared publication - Ali Ercetin
Department of Naval Architecture and Marine Engineering, Maritime Faculty, Bandırma Onyedi Eylul University, Bandırma, Türkiye
1 shared publication Cuma Kilinc
Gazi University, Technology Faculty, Energy Systems Engineering Department, Ankara, TURKEY
1 shared publication
Latest Publications
- Open Access
- 12 November 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (11) , 1365
A Simple Pump-Free Approach to Generating High-Throughput Microdroplets Using Oscillating Microcone Arrays
Droplet generation is crucial in various scientific and industrial fields, such as drug delivery, diagnostics, and inkjet printing. While microfluidic platforms enable precise droplet formation, traditional methods often require costly and complex setups, limiting their accessibility. This study introduces a simple, low-cost approach using an off-the-shelf unit and a 3D-printed reservoir. The device, equipped with a driver board, piezo-ring transducer, and a metal sheet with holes, generates oil-in-water (O/W) droplets with an average diameter of 4.62 ± 0.67 µm without external fluid pumps. Its simplicity, cost-effectiveness, and scalability make it highly suitable for both lab-on-chip and industrial applications, demonstrating the feasibility of large-scale uniform droplet production.
- 12 November 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (11) , 1365
Open AccessA Simple Pump-Free Approach to Generating High-Throughput Microdroplets Using Oscillating Microcone Arrays
Droplet generation is crucial in various scientific and industrial fields, such as drug delivery, diagnostics, and inkjet printing. While microfluidic platforms enable precise droplet formation, traditional methods often require costly and complex setups, limiting their accessibility. This study introduces a simple, low-cost approach using an off-the-shelf unit and a 3D-printed reservoir. The device, equipped with a driver board, piezo-ring transducer, and a metal sheet with holes, generates oil-in-water (O/W) droplets with an average diameter of 4.62 ± 0.67 µm without external fluid pumps. Its simplicity, cost-effectiveness, and scalability make it highly suitable for both lab-on-chip and industrial applications, demonstrating the feasibility of large-scale uniform droplet production.
- Open Access
- 15 April 2024
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 28 (5) , 1-9
A 3D printed acoustofluidic nozzle-diffuser microfluidic pump
Microfluidic flow control systems are critical components for on-chip biomedical applications. This study introduces a new micropump for on-chip sample preparation and analysis by using an acoustic nozzle diffuser mechanism. The micropump implements a commercially available transducer and control board kit with 3D-printed fluid reservoirs. In this micropump, conic-shaped micro-holes on the metal sheet cover of the transducer are employed as oscillating nozzle diffuser micro arrays to achieve directional flow control. The micropump is shown to efficiently pump water and particle mixtures exceeding flow rates of 515 µl/min at a 12-volt input voltage. In addition, owing to the small size of the nozzle hole opening, larger particles can also be filtered out from a sample solution during fluid pumping enabling a new function. Importantly, the micropump can be fabricated and assembled without needing a cleanroom, making it more accessible. This feature is advantageous for researchers and practitioners, eliminating a significant barrier to entry. By combining commercially available components with 3D printing technology, this micropump presents a cost-effective and versatile solution for on-chip applications in biomedical research and analysis.
- 15 April 2024
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 28 (5) , 1-9
Open AccessA 3D printed acoustofluidic nozzle-diffuser microfluidic pump
Microfluidic flow control systems are critical components for on-chip biomedical applications. This study introduces a new micropump for on-chip sample preparation and analysis by using an acoustic nozzle diffuser mechanism. The micropump implements a commercially available transducer and control board kit with 3D-printed fluid reservoirs. In this micropump, conic-shaped micro-holes on the metal sheet cover of the transducer are employed as oscillating nozzle diffuser micro arrays to achieve directional flow control. The micropump is shown to efficiently pump water and particle mixtures exceeding flow rates of 515 µl/min at a 12-volt input voltage. In addition, owing to the small size of the nozzle hole opening, larger particles can also be filtered out from a sample solution during fluid pumping enabling a new function. Importantly, the micropump can be fabricated and assembled without needing a cleanroom, making it more accessible. This feature is advantageous for researchers and practitioners, eliminating a significant barrier to entry. By combining commercially available components with 3D printing technology, this micropump presents a cost-effective and versatile solution for on-chip applications in biomedical research and analysis.
- Open Access
- 8 August 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1570
Continuous Flow Separation of Live and Dead Cells Using Gravity Sedimentation
The separation of target cell species is an important step for various biomedical applications ranging from single cell studies to drug testing and cell-based therapies. The purity of cell solutions is critical for therapeutic application. For example, dead cells and debris can negatively affect the efficacy of cell-based therapies. This study presents a cost-effective method for the continuous separation of live and dead cells using a 3D resin-printed microfluidic device. Saccharomyces cerevisiae yeast cells are used for cell separation experiments. Both numerical and experimental studies are presented to show the effectiveness of the presented device for the isolation of dead cells from cell solutions. The experimental results show that the 3D-printed microfluidic device successfully separates live and dead cells based on density differences. Separation efficiencies of over 95% are achieved at optimum flow rates, resulting in purer cell populations in the outlets. This study highlights the simplicity, cost-effectiveness, and potential applications of the 3D-printed microfluidic device for cell separation. The implementation of 3D printing technology in microfluidics holds promise for advancing the field and enabling the production of customized devices for biomedical applications.
- 8 August 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1570
Open AccessContinuous Flow Separation of Live and Dead Cells Using Gravity Sedimentation
The separation of target cell species is an important step for various biomedical applications ranging from single cell studies to drug testing and cell-based therapies. The purity of cell solutions is critical for therapeutic application. For example, dead cells and debris can negatively affect the efficacy of cell-based therapies. This study presents a cost-effective method for the continuous separation of live and dead cells using a 3D resin-printed microfluidic device. Saccharomyces cerevisiae yeast cells are used for cell separation experiments. Both numerical and experimental studies are presented to show the effectiveness of the presented device for the isolation of dead cells from cell solutions. The experimental results show that the 3D-printed microfluidic device successfully separates live and dead cells based on density differences. Separation efficiencies of over 95% are achieved at optimum flow rates, resulting in purer cell populations in the outlets. This study highlights the simplicity, cost-effectiveness, and potential applications of the 3D-printed microfluidic device for cell separation. The implementation of 3D printing technology in microfluidics holds promise for advancing the field and enabling the production of customized devices for biomedical applications.
- Open Access
- 12 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1409
A Miniaturized Archimedean Screw Pump for High-Viscosity Fluid Pumping in Microfluidics
Microfluidic devices have revolutionized the field of lab-on-a-chip by enabling precise manipulation of small fluid volumes for various biomedical applications. However, most existing microfluidic pumps struggle to handle high-viscosity fluids, limiting their applicability in certain areas that involve bioanalysis and on-chip sample processing. In this paper, the design and fabrication of a miniaturized Archimedean screw pump for pumping high-viscosity fluids within microfluidic channels are presented. The pump was 3D-printed and operated vertically, allowing for continuous and directional fluid pumping. The pump’s capabilities were demonstrated by successfully pumping polyethylene glycol (PEG) solutions that are over 100 times more viscous than water using a basic mini-DC motor. Efficient fluid manipulation at low voltages was achieved by the pump, making it suitable for point-of-care and field applications. The flow rates of water were characterized, and the effect of different screw pitch lengths on the flow rate was investigated. Additionally, the pump’s capacity for pumping high-viscosity fluids was demonstrated by testing it with PEG solutions of increasing viscosity. The microfluidic pump’s simple fabrication and easy operation position it as a promising candidate for lab-on-a-chip applications involving high-viscosity fluids.
- 12 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1409
Open AccessA Miniaturized Archimedean Screw Pump for High-Viscosity Fluid Pumping in Microfluidics
Microfluidic devices have revolutionized the field of lab-on-a-chip by enabling precise manipulation of small fluid volumes for various biomedical applications. However, most existing microfluidic pumps struggle to handle high-viscosity fluids, limiting their applicability in certain areas that involve bioanalysis and on-chip sample processing. In this paper, the design and fabrication of a miniaturized Archimedean screw pump for pumping high-viscosity fluids within microfluidic channels are presented. The pump was 3D-printed and operated vertically, allowing for continuous and directional fluid pumping. The pump’s capabilities were demonstrated by successfully pumping polyethylene glycol (PEG) solutions that are over 100 times more viscous than water using a basic mini-DC motor. Efficient fluid manipulation at low voltages was achieved by the pump, making it suitable for point-of-care and field applications. The flow rates of water were characterized, and the effect of different screw pitch lengths on the flow rate was investigated. Additionally, the pump’s capacity for pumping high-viscosity fluids was demonstrated by testing it with PEG solutions of increasing viscosity. The microfluidic pump’s simple fabrication and easy operation position it as a promising candidate for lab-on-a-chip applications involving high-viscosity fluids.
- Open Access
- 6 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7938
A Low-Cost Laser-Prototyped Microfluidic Device for Separating Cells and Bacteria
Simple and rapid fabrication of microfluidic devices can enable widespread implementation of lab-on-chip devices in resource-limited environments. However, currently most of the microfluidic devices are fabricated in cleanroom facilities that are well-funded and not accessible to most of the researchers in developing countries. Herein, a simple, low-cost, and reliable method is shown to fabricate microfluidic devices for separating cells and bacteria-size microparticles. For this purpose, serpentine and spiral microfluidic channels are designed and fabricated using rapid laser prototyping. This single inlet microfluidic device is shown to successfully separate yeast cells and smaller microparticles with an efficiency of 85% which is very promising for many lab-on-chip applications including cell-based diagnostics and therapeutics.
- 6 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7938
Open AccessA Low-Cost Laser-Prototyped Microfluidic Device for Separating Cells and Bacteria
Simple and rapid fabrication of microfluidic devices can enable widespread implementation of lab-on-chip devices in resource-limited environments. However, currently most of the microfluidic devices are fabricated in cleanroom facilities that are well-funded and not accessible to most of the researchers in developing countries. Herein, a simple, low-cost, and reliable method is shown to fabricate microfluidic devices for separating cells and bacteria-size microparticles. For this purpose, serpentine and spiral microfluidic channels are designed and fabricated using rapid laser prototyping. This single inlet microfluidic device is shown to successfully separate yeast cells and smaller microparticles with an efficiency of 85% which is very promising for many lab-on-chip applications including cell-based diagnostics and therapeutics.
- Open Access
A Multi-Flow Production Line for Sorting of Eggs Using Image Processing
In egg production facilities, the classification of eggs is carried out either manually or by using sophisticated systems such as load cells. However, there is a need for the classification of eggs to be carried out with faster and cheaper methods. In the agri-food industry, the use of image processing technology is continuously increasing due to the data processing speed and cost-effective solutions. In this study, an image processing approach was used to classify chicken eggs on an industrial roller conveyor line in real-time. A color camera was used to acquire images in an illumination cabinet on a motorized roller conveyor while eggs are moving on the movement halls. The system successfully operated for the grading of eggs in the industrial multi-flow production line in real-time. There were significant correlations among measured weights of the eggs after image processing. The coefficient of linear correlation (R2) between measured and actual weights was 0.95.
Open AccessA Multi-Flow Production Line for Sorting of Eggs Using Image Processing
In egg production facilities, the classification of eggs is carried out either manually or by using sophisticated systems such as load cells. However, there is a need for the classification of eggs to be carried out with faster and cheaper methods. In the agri-food industry, the use of image processing technology is continuously increasing due to the data processing speed and cost-effective solutions. In this study, an image processing approach was used to classify chicken eggs on an industrial roller conveyor line in real-time. A color camera was used to acquire images in an illumination cabinet on a motorized roller conveyor while eggs are moving on the movement halls. The system successfully operated for the grading of eggs in the industrial multi-flow production line in real-time. There were significant correlations among measured weights of the eggs after image processing. The coefficient of linear correlation (R2) between measured and actual weights was 0.95.
- Open Access
- 20 December 2021
- Published by European Mechanical Science in European Mechanical Science
- Vol. 5 (4) , 201-205
A Battery Powered on-Chip Peristaltic Pump for Lab-On-A-Chip Applications
Low-cost and controllable fluid manipulation in small scale is important to biomedical research, and disease testing and diagnostics. In the midst of global disease outbreaks and pandemics such as Ebola and Covid-19, rapid and low-cost testing and diagnostics have become even more crucial. Lab-on-a-chip platforms are good candidates to be applied in these circumstances due their small footprints and lower-costs which enable rapid-prototyping of these devices. However, providing controlled fluid flow handling in small scale for on-chip devices is not currently suitable for point-of-care applications due to the expensive fluid pumping systems that currently used in most of the lab-on-a-chip devices. In this work, a low-cost and practical peristaltic pump is developed using 3D printing and open-sourced microcontroller platform Arduino boards. The entire system is designed to be portable and capable of producing metered fluid flow in small scale devices. The developed device is characterized to provide adjustable fluid flow control between 1.7 µL/s to 23 µL/s which is suitable for many on-chip applications. The peristaltic pump developed in this work can be used in lab-on-a-chip applications due to its simplicity and low-cost.
- 20 December 2021
- Published by European Mechanical Science in European Mechanical Science
- Vol. 5 (4) , 201-205
Open AccessA Battery Powered on-Chip Peristaltic Pump for Lab-On-A-Chip Applications
Low-cost and controllable fluid manipulation in small scale is important to biomedical research, and disease testing and diagnostics. In the midst of global disease outbreaks and pandemics such as Ebola and Covid-19, rapid and low-cost testing and diagnostics have become even more crucial. Lab-on-a-chip platforms are good candidates to be applied in these circumstances due their small footprints and lower-costs which enable rapid-prototyping of these devices. However, providing controlled fluid flow handling in small scale for on-chip devices is not currently suitable for point-of-care applications due to the expensive fluid pumping systems that currently used in most of the lab-on-a-chip devices. In this work, a low-cost and practical peristaltic pump is developed using 3D printing and open-sourced microcontroller platform Arduino boards. The entire system is designed to be portable and capable of producing metered fluid flow in small scale devices. The developed device is characterized to provide adjustable fluid flow control between 1.7 µL/s to 23 µL/s which is suitable for many on-chip applications. The peristaltic pump developed in this work can be used in lab-on-a-chip applications due to its simplicity and low-cost.
- Open Access
- 24 November 2021
- Published by AIP Publishing in Biomicrofluidics
- Vol. 15 (6)
Potential of the acoustic micromanipulation technologies for biomedical research
Acoustic micromanipulation technologies are a set of versatile tools enabling unparalleled micromanipulation capabilities. Several characteristics put the acoustic micromanipulation technologies ahead of most of the other tweezing methods. For example, acoustic tweezers can be adapted as non-invasive platforms to handle single cells gently or as probes to stimulate or damage tissues. Besides, the nature of the interactions of acoustic waves with solids and liquids eliminates labeling requirements. Considering the importance of highly functional tools in biomedical research for empowering important discoveries, acoustic micromanipulation can be valuable for researchers in biology and medicine. Herein, we discuss the potential of acoustic micromanipulation technologies from technical and application points of view in biomedical research.
- 24 November 2021
- Published by AIP Publishing in Biomicrofluidics
- Vol. 15 (6)
Open AccessPotential of the acoustic micromanipulation technologies for biomedical research
Acoustic micromanipulation technologies are a set of versatile tools enabling unparalleled micromanipulation capabilities. Several characteristics put the acoustic micromanipulation technologies ahead of most of the other tweezing methods. For example, acoustic tweezers can be adapted as non-invasive platforms to handle single cells gently or as probes to stimulate or damage tissues. Besides, the nature of the interactions of acoustic waves with solids and liquids eliminates labeling requirements. Considering the importance of highly functional tools in biomedical research for empowering important discoveries, acoustic micromanipulation can be valuable for researchers in biology and medicine. Herein, we discuss the potential of acoustic micromanipulation technologies from technical and application points of view in biomedical research.
- Open Access
- 1 January 2019
- Published by National Library of Serbia in Thermal Science
- Vol. 23 (6 Part B) , 3917-3928
The heat transfer enhancement of concurrent flow and counter current flow concentric tube heat exchangers by using hexagonal boron nitride/water nanofluid
Heat exchangers are used in many applications including chemical, oil, and gas power generation, refrigeration, pharmaceuticals, and food processing. Because of their widespread usage, they have various types to serve at different working conditions. Increasing the performance of heat exchangers has become a very interesting field of study since the efficiency of various industrial and domestic systems depend on them. In this study, a coaxial double tube experimental set-up was prepared, and the effect of using nanohexagonal boron nitride nanofluid as hot working fluid on the heat transfer performance increase was investigated. The experiments were carried out in concurrent flow and counter flow conditions for various hot fluid-flow rates to obtain the heat transfer coefficients. Nanohexagonal boron nitride obtained in powder form was used to prepare the nanofluid by a two-step method. The 4 kg nanofluid containing 2% nanohexagonal boron nitride with 0.5% Triton X-100 as a surfactant in terms of mass ratio was prepared for the experiments. Heat transfer experiments were carried out three times by using the prepared nanohexagonal boron nitride/water nanofluid and pure water as hot fluid to reach more precise results. In the result of this study, the total heat transfer coefficient showed an average improvement of 48.78% for the concurrent flow heat exchanger, while an average improvement of 0.36% was observed in the counter flow conditions compared to the base fluid. This study shows the potential of application of nanohexagonal boron nitride/water nanofluid in heat management applications.
- 1 January 2019
- Published by National Library of Serbia in Thermal Science
- Vol. 23 (6 Part B) , 3917-3928
Open AccessThe heat transfer enhancement of concurrent flow and counter current flow concentric tube heat exchangers by using hexagonal boron nitride/water nanofluid
Heat exchangers are used in many applications including chemical, oil, and gas power generation, refrigeration, pharmaceuticals, and food processing. Because of their widespread usage, they have various types to serve at different working conditions. Increasing the performance of heat exchangers has become a very interesting field of study since the efficiency of various industrial and domestic systems depend on them. In this study, a coaxial double tube experimental set-up was prepared, and the effect of using nanohexagonal boron nitride nanofluid as hot working fluid on the heat transfer performance increase was investigated. The experiments were carried out in concurrent flow and counter flow conditions for various hot fluid-flow rates to obtain the heat transfer coefficients. Nanohexagonal boron nitride obtained in powder form was used to prepare the nanofluid by a two-step method. The 4 kg nanofluid containing 2% nanohexagonal boron nitride with 0.5% Triton X-100 as a surfactant in terms of mass ratio was prepared for the experiments. Heat transfer experiments were carried out three times by using the prepared nanohexagonal boron nitride/water nanofluid and pure water as hot fluid to reach more precise results. In the result of this study, the total heat transfer coefficient showed an average improvement of 48.78% for the concurrent flow heat exchanger, while an average improvement of 0.36% was observed in the counter flow conditions compared to the base fluid. This study shows the potential of application of nanohexagonal boron nitride/water nanofluid in heat management applications.
- 18 August 2009
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 40 (8) , 638-642
Mechanical properties of friction stir butt‐welded Al‐5086 H32 plate
Al‐5086 H32 plates with a thickness of 3 mm were friction stir butt‐welded using different welding speeds at a tool rotational speed of 1600 rpm. The effect of welding speed on the weld performance of the joints was investigated by conducting optical microscopy, microhardness measurements and mechanical tests (i.e. tensile and bend tests). The effect of heat input during friction stir welding on the microstructure, and thus mechanical properties, of cold‐rolled Al‐ 5086 plates was also determined. The experimental results indicated that the maximum tensile strength of the joints, which is about 75 % that of the base plate, was obtained with a traverse speed of 200 mm/min at the tool rotational speed used, e.g. 1600 rpm, and the maximum bending angle of the joints can reach 180o. The maximum ductility performance of the joints was, on the other hand, relatively low, e.g. about 20 %. These results are not unexpected due to the loss of the cold‐work strengthening in the weld region as a result of the heat input during welding, and thus the confined plasticity within the stirred zone owing to strength undermatching. Higher joint performances can also be achieved by increasing the penetration depth of the stirring probe in butt‐friction stir welding of Al‐5086 H32 plates.
- 18 August 2009
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 40 (8) , 638-642
Mechanical properties of friction stir butt‐welded Al‐5086 H32 plate
Al‐5086 H32 plates with a thickness of 3 mm were friction stir butt‐welded using different welding speeds at a tool rotational speed of 1600 rpm. The effect of welding speed on the weld performance of the joints was investigated by conducting optical microscopy, microhardness measurements and mechanical tests (i.e. tensile and bend tests). The effect of heat input during friction stir welding on the microstructure, and thus mechanical properties, of cold‐rolled Al‐ 5086 plates was also determined. The experimental results indicated that the maximum tensile strength of the joints, which is about 75 % that of the base plate, was obtained with a traverse speed of 200 mm/min at the tool rotational speed used, e.g. 1600 rpm, and the maximum bending angle of the joints can reach 180o. The maximum ductility performance of the joints was, on the other hand, relatively low, e.g. about 20 %. These results are not unexpected due to the loss of the cold‐work strengthening in the weld region as a result of the heat input during welding, and thus the confined plasticity within the stirred zone owing to strength undermatching. Higher joint performances can also be achieved by increasing the penetration depth of the stirring probe in butt‐friction stir welding of Al‐5086 H32 plates.