Hernando Leon-Rodriguez
Research Subjects
Hernando Leon-Rodriguez has a total of 465 co-authors. Here are the top co-authors by number of shared publications:
Jong-Oh Park
10 shared publicationsCheong Lee
6 shared publicationsSukho Park
School of Mechanical Engineering, Chonnam National University, Gwangju 500-757, Korea
6 shared publicationsTariq P. Sattar
Centre for Automated and Robotic NDT, Faculty of Engineering, Science & the Built Environment, London South Bank University, 103 Borough Road, London SE1 0AA, UK
6 shared publications- Alvaro Uribe-Quevedo
Game Development and Interactive Media Program, Ontario Tech University, Oshawa, ON L1G 0C5, Canada
5 shared publications Seong Young Ko
School of Mechanical Engineering, Chonnam National University, Gwangju, 500-757, Korea
5 shared publications
Latest Publications
- Open Access
Bifacial Solar Modules Under Real Operating Conditions: Insights into Rear Irradiance, Installation Type and Model Accuracy
Bifacial Photovoltaic (bPV) technology is rapidly becoming the standard in the solar photovoltaic (PV) industry due to its ability to capture reflected radiation and generate additional energy. This experimental study analyses the electrical performance of bPV modules under specific installation conditions, including varying heights, module tilt angles (MTA), and surface reflectivity. The methodology combines controlled indoor testing with outdoor experiments that replicate real-world operating environments. The outdoor test setup was carefully designed and included dual data acquisition systems: one with independent sensors and another with wireless telemetry for data transfer from the inverter. A thermal performance model was used to estimate energy output and was benchmarked against experimental measurements. All electrical parameters were obtained in accordance with international standards, including current-voltage characteristic (I–V curve) corrections, using calibrated instruments to monitor irradiance and temperature. Indoor measurements under Standard Test Conditions yielded at bifaciality coefficient , a rear bifacial power gain , and a relative bifacial gain . The outdoor configuration employed volcanic red stone (Tezontle) as a reflective surface, simulating a typical mid-latitude installation with modules mounted 1.5 m above ground, tilted from 0° to 90° regarding floor and oriented true south. The study was conducted at a site located at 18.8° N latitude during the early summer season. Results revealed significant non-uniformity in rear-side irradiance, with a 32% variation between the lower edge and the centre of the bPV module. The thermal model used to determine electrical performance provides power values higher than those measured in the time interval between 10 a.m. and 3 p.m. Maximum energy output was observed at a MTA of , which closely aligns with the optimal summer tilt angle for the site’s latitude. Bifacial energy gain decreased as the MTA increased from to . These findings offer practical, data-driven insights for optimizing bPV installations, particularly in regions between and north latitude, and emphasize the importance of tailored surface designs to maximize performance.Open AccessBifacial Solar Modules Under Real Operating Conditions: Insights into Rear Irradiance, Installation Type and Model Accuracy
Bifacial Photovoltaic (bPV) technology is rapidly becoming the standard in the solar photovoltaic (PV) industry due to its ability to capture reflected radiation and generate additional energy. This experimental study analyses the electrical performance of bPV modules under specific installation conditions, including varying heights, module tilt angles (MTA), and surface reflectivity. The methodology combines controlled indoor testing with outdoor experiments that replicate real-world operating environments. The outdoor test setup was carefully designed and included dual data acquisition systems: one with independent sensors and another with wireless telemetry for data transfer from the inverter. A thermal performance model was used to estimate energy output and was benchmarked against experimental measurements. All electrical parameters were obtained in accordance with international standards, including current-voltage characteristic (I–V curve) corrections, using calibrated instruments to monitor irradiance and temperature. Indoor measurements under Standard Test Conditions yielded at bifaciality coefficient , a rear bifacial power gain , and a relative bifacial gain . The outdoor configuration employed volcanic red stone (Tezontle) as a reflective surface, simulating a typical mid-latitude installation with modules mounted 1.5 m above ground, tilted from 0° to 90° regarding floor and oriented true south. The study was conducted at a site located at 18.8° N latitude during the early summer season. Results revealed significant non-uniformity in rear-side irradiance, with a 32% variation between the lower edge and the centre of the bPV module. The thermal model used to determine electrical performance provides power values higher than those measured in the time interval between 10 a.m. and 3 p.m. Maximum energy output was observed at a MTA of , which closely aligns with the optimal summer tilt angle for the site’s latitude. Bifacial energy gain decreased as the MTA increased from to . These findings offer practical, data-driven insights for optimizing bPV installations, particularly in regions between and north latitude, and emphasize the importance of tailored surface designs to maximize performance. - Open Access
- 26 July 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 74
Dimensionless analysis and novel configuration for enhanced natural convection cooling in lithium-ion batteries
- 26 July 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 74
Open AccessDimensionless analysis and novel configuration for enhanced natural convection cooling in lithium-ion batteries
- 11 August 2020
- Published by Springer Nature
- p. 384-393
Kinematic Model Analysis and ROS Control of Cable Driven Continuous Robot Manipulator
- 11 August 2020
- Published by Springer Nature
- p. 384-393
Kinematic Model Analysis and ROS Control of Cable Driven Continuous Robot Manipulator
- 9 October 2019
- Published by Springer Nature
- p. 135-146
Maze Solution Device with Stewart’s Platform and OpenCV
- 9 October 2019
- Published by Springer Nature
- p. 135-146
Maze Solution Device with Stewart’s Platform and OpenCV
- 9 October 2019
- Published by Springer Nature
- p. 64-77
Path Tracking Control for Micro-robots with Helmholtz-Maxwell Coils Actuation
- 9 October 2019
- Published by Springer Nature
- p. 64-77
Path Tracking Control for Micro-robots with Helmholtz-Maxwell Coils Actuation
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Eyes and Neck Kinematic Model Analysis with Limited Human Gestures
Human emotions such as happiness, sadness, despair, amazement among others are produced by the limbic system which causes the movement of the facial muscles as a result of those emotions. In the realization of Rudolf, the animatronic, was considered, the simulation, interpretation and imitation of human movements of eyes, neck and mouth, in order to respond immediately to the emotions of the human being. Each of these movements were analysed kinematically and dynamically by the Denavit-Hartenberg matrices. In order to imitate the facial gestures of a human, the dynamics of the eyes, their degrees of freedom (DOF), as well as the neck and lower jaw, were physically analysed in order to perfect the imitation of a human being. On the other hand, the neural system of real-time image storage, activation of actuators and facial recognition was made through programming in Python and decoding with the Raspberry Pi Hardware.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Eyes and Neck Kinematic Model Analysis with Limited Human Gestures
Human emotions such as happiness, sadness, despair, amazement among others are produced by the limbic system which causes the movement of the facial muscles as a result of those emotions. In the realization of Rudolf, the animatronic, was considered, the simulation, interpretation and imitation of human movements of eyes, neck and mouth, in order to respond immediately to the emotions of the human being. Each of these movements were analysed kinematically and dynamically by the Denavit-Hartenberg matrices. In order to imitate the facial gestures of a human, the dynamics of the eyes, their degrees of freedom (DOF), as well as the neck and lower jaw, were physically analysed in order to perfect the imitation of a human being. On the other hand, the neural system of real-time image storage, activation of actuators and facial recognition was made through programming in Python and decoding with the Raspberry Pi Hardware.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Developed of a Cartesian CNC System for Plasma Metal Sheet Cutting
A Cartesian system was one of the first mechanism used to carried out a kinematical model, which characterise its advantages and restrictions in order to enhance different motions for industrial applications. This paper describes one of the most used applications in the industry called Computerized Numerical Control (CNC) used as a machine automated tool. The project development is divided into two large structures, the mechanical system and the electronic system. The 3 DOF automated CNC machine is driven with transmission by tooth-belt and spindle attached with to one manual plasma cutting equipment; with the constraint of generation of high index of electromagnetic interference due to its configuration of arc start by high frequency. It limitations was solved and highly decrease thanks to the implementation of complementary electronic designs such as filters, opto-couplers and a physical grounded. The execution of G-codes is compliances with established technical standards ensuring a uniform fluid-arc and safe behaviour.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Developed of a Cartesian CNC System for Plasma Metal Sheet Cutting
A Cartesian system was one of the first mechanism used to carried out a kinematical model, which characterise its advantages and restrictions in order to enhance different motions for industrial applications. This paper describes one of the most used applications in the industry called Computerized Numerical Control (CNC) used as a machine automated tool. The project development is divided into two large structures, the mechanical system and the electronic system. The 3 DOF automated CNC machine is driven with transmission by tooth-belt and spindle attached with to one manual plasma cutting equipment; with the constraint of generation of high index of electromagnetic interference due to its configuration of arc start by high frequency. It limitations was solved and highly decrease thanks to the implementation of complementary electronic designs such as filters, opto-couplers and a physical grounded. The execution of G-codes is compliances with established technical standards ensuring a uniform fluid-arc and safe behaviour.
- Open Access
- 28 November 2018
- Published by Universidad de Pamplona in REVISTA COLOMBIANA DE TECNOLOGIAS DE AVANZADA
- Vol. 2 (32)
MICRO ROBOTS CONTROLADOS POR ACTUADORES ELECTROMAGNÉTICOS EN APLICACIONES MÉDICAS
Los robots para aplicaciones médicas en la micro escala son la combinación de la tecnología de fabricación tradicional con tecnología de MEMS (micro electro-mechanical systems) sumadas con tecnologías como nano-tecnología, ingeniería biomédica y ciencia de los Materiales. Los robots en escala humana aplicados a la medicina son dispositivos desarrollados y adaptados con tecnologías de aplicaciones industriales. Sin embargo, en la actualidad la ciencia médica busca miniaturización para minimizar las cirugías, el dolor y el sangrado en el paciente; es aquí donde los micros robots son una tecnología emergente que permitirá llevar con micro-cámaras, micro-manipuladores, y nano-sensores a áreas del cuerpo que no requerirán cirugía sino la utilización de los orificios naturales del cuerpo. Este artículo presenta una revisión de los dispositivos robóticos médicos del presente y del futuro cercano en la salud.
- 28 November 2018
- Published by Universidad de Pamplona in REVISTA COLOMBIANA DE TECNOLOGIAS DE AVANZADA
- Vol. 2 (32)
Open AccessMICRO ROBOTS CONTROLADOS POR ACTUADORES ELECTROMAGNÉTICOS EN APLICACIONES MÉDICAS
Los robots para aplicaciones médicas en la micro escala son la combinación de la tecnología de fabricación tradicional con tecnología de MEMS (micro electro-mechanical systems) sumadas con tecnologías como nano-tecnología, ingeniería biomédica y ciencia de los Materiales. Los robots en escala humana aplicados a la medicina son dispositivos desarrollados y adaptados con tecnologías de aplicaciones industriales. Sin embargo, en la actualidad la ciencia médica busca miniaturización para minimizar las cirugías, el dolor y el sangrado en el paciente; es aquí donde los micros robots son una tecnología emergente que permitirá llevar con micro-cámaras, micro-manipuladores, y nano-sensores a áreas del cuerpo que no requerirán cirugía sino la utilización de los orificios naturales del cuerpo. Este artículo presenta una revisión de los dispositivos robóticos médicos del presente y del futuro cercano en la salud.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 633-634
Intraousseous Access Simulator in Newborns VR System
Simulators in medical procedures are important tools for learning, teaching and training allowing practices in a wide range of scenarios of life-like situations. In the field of vascular access, the use of virtual reality has been emerging as a complement to address the current problems due to the low availability of simulation manikins for training and its high cost. Intraosseous access in newborns is an invasive, fast and effective medical procedure of high complexity employed in critically ill newborns as an option to access veins after peripheral access has failed. Due to vein vasoconstriction present in neonatal shock and cardiorespiratory arrest among other life-threatening conditions it is difficult to perform any other forms of venous access. Intraosseous access requires the proper handling of the related equipment and knowledge, this is only possible with continuous training that cannot be done in real patients. Mastering this technique is required to preserve patient's life, achieve a good recovery and reduce the risk of infection or even death. This paper presents the development of a newborn's intraosseous access simulator for training covering the required steps involved in the procedure. To increase the immersion of the simulation, a force feedback haptic device is integrated to simulate the needle insertion beneath leg tissues to the bone with a biomechanical tissue model, which is the more important skill to be developed in this procedure, and a consumer head mounted display to provide a stereo view of the operation room to give depth to the user when approaching to the patient leg. Our preliminary results were evaluated by a medical expert in terms of usability of the prototype.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 633-634
Intraousseous Access Simulator in Newborns VR System
Simulators in medical procedures are important tools for learning, teaching and training allowing practices in a wide range of scenarios of life-like situations. In the field of vascular access, the use of virtual reality has been emerging as a complement to address the current problems due to the low availability of simulation manikins for training and its high cost. Intraosseous access in newborns is an invasive, fast and effective medical procedure of high complexity employed in critically ill newborns as an option to access veins after peripheral access has failed. Due to vein vasoconstriction present in neonatal shock and cardiorespiratory arrest among other life-threatening conditions it is difficult to perform any other forms of venous access. Intraosseous access requires the proper handling of the related equipment and knowledge, this is only possible with continuous training that cannot be done in real patients. Mastering this technique is required to preserve patient's life, achieve a good recovery and reduce the risk of infection or even death. This paper presents the development of a newborn's intraosseous access simulator for training covering the required steps involved in the procedure. To increase the immersion of the simulation, a force feedback haptic device is integrated to simulate the needle insertion beneath leg tissues to the bone with a biomechanical tissue model, which is the more important skill to be developed in this procedure, and a consumer head mounted display to provide a stereo view of the operation room to give depth to the user when approaching to the patient leg. Our preliminary results were evaluated by a medical expert in terms of usability of the prototype.
- 1 January 2018
- Published by INSTICC
- p. 487-495
Improving the Joint Mobility of Acute Rotator Cuff Injury by Portable Rehabilitation Device
The incidence of shoulder pain in the general population is around 11.2 cases per 1,000 patients per year. It is considered to be the most prevalent soft tissue pathology, with an estimated incidence of rotator cuff injuries of 3.7 per 100,000 per year. The deterioration of the components of the rotator cuff is one of the most frequent causes of musculoskeletal pain and disability in the world. The conditions of the rotator cuff increase with the age and overuse of the joint, therefore, elderly patients are more affected. This paper presents the development of one soft and portable rehabilitation prototype robot that aims to be evaluated with patients in near future as a suitable device for rehabilitating acute rotator cuff injuries through clinical examinations. The portable robot presented was design from biomechanical analysis and ranges of kinematics and joint dynamics; aspects that determined important requirements for obtaining greater functionality of the prototypeś portability
- 1 January 2018
- Published by INSTICC
- p. 487-495
Improving the Joint Mobility of Acute Rotator Cuff Injury by Portable Rehabilitation Device
The incidence of shoulder pain in the general population is around 11.2 cases per 1,000 patients per year. It is considered to be the most prevalent soft tissue pathology, with an estimated incidence of rotator cuff injuries of 3.7 per 100,000 per year. The deterioration of the components of the rotator cuff is one of the most frequent causes of musculoskeletal pain and disability in the world. The conditions of the rotator cuff increase with the age and overuse of the joint, therefore, elderly patients are more affected. This paper presents the development of one soft and portable rehabilitation prototype robot that aims to be evaluated with patients in near future as a suitable device for rehabilitating acute rotator cuff injuries through clinical examinations. The portable robot presented was design from biomechanical analysis and ranges of kinematics and joint dynamics; aspects that determined important requirements for obtaining greater functionality of the prototypeś portability