Viktor Steixner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Viktor Steixner has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Clemens M. Zierhofer
Department of Mechatronics, University of Innsbruck, Innsbruck, Austria
4 shared publications P. Zoller
3 shared publications- Peter Rabl
Technical University of Munich
3 shared publications Andreas Griessner
UNIVERSITY OF INNSBRUCK, INNSBRUCK, Austria
2 shared publications- Andreas Griessner
Department of Mechatronics, University of Innsbruck, Innsbruck, Austria
2 shared publications - David Lanthaler
Department of Mechatronics, University of Innsbruck, Innsbruck, Austria
2 shared publications
Latest Publications
- Open Access
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1740-1750
A Wearable Research System for Combined Cochleo-Vestibular Stimulation
Cochlear implants (CI) are a well-established treatment option for patients with severe to profound hearing loss, while vestibular implant (VI) trials give a promising outlook for patients with severely impaired vestibular function. In a number of subjects these two conditions may also present together, necessitating treatment with a cochleo-vestibular implant (CVI). While the feasibility of CVIs has been demonstrated, no wearable processor has existed to provide target-specific, modulated stimulation for both systems over extended periods. We introduce a first wearable audio-motion processor (AMP) system designed to be used in conjunction with a CVI. We first present the architecture of the AMP, along with the possible modes of operation. We then use a testbench to show the functionality and limits of the presented device. Important performance characteristics of such a system are the latency between head movements and resulting vestibular stimulation pulses, and the deviations of stimulation amplitudes and pulse rates from a programmed transfer function (TF). The device was tested using amplitude- and rate-modulated vestibular pulses in response to predefined single-axis rotations performed on a rotary platform, while providing simultaneous auditory stimulation to cochlear electrodes. We were able to achieve a recorded latency comparable to the physiological response time of normal vestibular organs. The results for the TF showed that the measured values for the pulse rates and the amplitudes followed the reference values very accurately. This audio-motion processor is the world’s first wearable processor capable of delivering combined, specifically modulated cochlear and vestibular stimulation.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1740-1750
Open AccessA Wearable Research System for Combined Cochleo-Vestibular Stimulation
Cochlear implants (CI) are a well-established treatment option for patients with severe to profound hearing loss, while vestibular implant (VI) trials give a promising outlook for patients with severely impaired vestibular function. In a number of subjects these two conditions may also present together, necessitating treatment with a cochleo-vestibular implant (CVI). While the feasibility of CVIs has been demonstrated, no wearable processor has existed to provide target-specific, modulated stimulation for both systems over extended periods. We introduce a first wearable audio-motion processor (AMP) system designed to be used in conjunction with a CVI. We first present the architecture of the AMP, along with the possible modes of operation. We then use a testbench to show the functionality and limits of the presented device. Important performance characteristics of such a system are the latency between head movements and resulting vestibular stimulation pulses, and the deviations of stimulation amplitudes and pulse rates from a programmed transfer function (TF). The device was tested using amplitude- and rate-modulated vestibular pulses in response to predefined single-axis rotations performed on a rotary platform, while providing simultaneous auditory stimulation to cochlear electrodes. We were able to achieve a recorded latency comparable to the physiological response time of normal vestibular organs. The results for the TF showed that the measured values for the pulse rates and the amplitudes followed the reference values very accurately. This audio-motion processor is the world’s first wearable processor capable of delivering combined, specifically modulated cochlear and vestibular stimulation.
- Open Access
- 16 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1644-1650
Speech Perception With Novel Stimulation Strategies for CombinedCochleo-Vestibular Systems
Cochlear implants are very well established in the rehabilitation of hearing loss and are regarded as the most successful neuroprostheses to date. While a lot of progress has also been made in the neighboring field of specific vestibular implants, some diseases affect the entire inner ear, leading to both hearing and vestibular hypo- or dysfunction. The proximity of the cochlear and vestibular organs suggests a single combined implant as a means to alleviate the associated impairments. While both organs can be stimulated in a similar way with electric pulses applied through implanted electrodes, the typical phase durations needed in the vestibular system seem to be substantially larger than those typically needed in the cochlear system. Therefore, when using sequential stimulation in a combined implant, the pulse stream to the cochlea is interrupted by comparatively large gaps in which vestibular stimulation can occur. We investigate the impact of these gaps in the auditory stream on speech perception. Specifically, we compare a number of stimulation strategies with different gap lengths and distributions and evaluate whether it is feasible to use them without having a noticeable decline in perception and quality of speech. This is a prerequisite for any practicable stimulation strategy of a combined system and can be investigated even in recipients of a normal cochlear implant. Our results show that there is no significant deterioration in speech perception for the different strategies examined in this paper, leaving the strategies as viable candidates for prospective combined cochleo-vestibular implants.
- 16 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1644-1650
Open AccessSpeech Perception With Novel Stimulation Strategies for CombinedCochleo-Vestibular Systems
Cochlear implants are very well established in the rehabilitation of hearing loss and are regarded as the most successful neuroprostheses to date. While a lot of progress has also been made in the neighboring field of specific vestibular implants, some diseases affect the entire inner ear, leading to both hearing and vestibular hypo- or dysfunction. The proximity of the cochlear and vestibular organs suggests a single combined implant as a means to alleviate the associated impairments. While both organs can be stimulated in a similar way with electric pulses applied through implanted electrodes, the typical phase durations needed in the vestibular system seem to be substantially larger than those typically needed in the cochlear system. Therefore, when using sequential stimulation in a combined implant, the pulse stream to the cochlea is interrupted by comparatively large gaps in which vestibular stimulation can occur. We investigate the impact of these gaps in the auditory stream on speech perception. Specifically, we compare a number of stimulation strategies with different gap lengths and distributions and evaluate whether it is feasible to use them without having a noticeable decline in perception and quality of speech. This is a prerequisite for any practicable stimulation strategy of a combined system and can be investigated even in recipients of a normal cochlear implant. Our results show that there is no significant deterioration in speech perception for the different strategies examined in this paper, leaving the strategies as viable candidates for prospective combined cochleo-vestibular implants.
- Open Access
- 5 January 2017
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 16 (1) , 1-18
Reduction of eddy current losses in inductive transmission systems with ferrite sheets
Improvements in eddy current suppression are necessary to meet the demand for increasing miniaturization of inductively driven transmission systems in industrial and biomedical applications. The high magnetic permeability and the simultaneously low electrical conductivity of ferrite materials make them ideal candidates for shielding metallic surfaces. For systems like cochlear implants the transmission of data as well as energy over an inductive link is conducted within a well-defined parameter set. For these systems, the shielding can be of particular importance if the properties of the link can be preserved. In this work, we investigate the effect of single and double-layered substrates consisting of ferrite and/or copper on the inductance and coupling of planar spiral coils. The examined link systems represent realistic configurations for active implantable systems such as cochlear implants. Experimental measurements are complemented with analytical calculations and finite element simulations, which are in good agreement for all measured parameters. The results are then used to study the transfer efficiency of an inductive link in a series–parallel resonant topology as a function of substrate size, the number of coil turns and coil separation. We find that ferrite sheets can be used to shield the system from unwanted metallic surfaces and to retain the inductive link parameters of the unperturbed system, particularly its transfer efficiency. The required size of the ferrite plates is comparable to the size of the coils, which makes the setup suitable for practical implementations. Since the sizes and geometries chosen for the studied inductive links are comparable to those of cochlear implants, our conclusions apply in particular to these systems.
- 5 January 2017
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 16 (1) , 1-18
Open AccessReduction of eddy current losses in inductive transmission systems with ferrite sheets
Improvements in eddy current suppression are necessary to meet the demand for increasing miniaturization of inductively driven transmission systems in industrial and biomedical applications. The high magnetic permeability and the simultaneously low electrical conductivity of ferrite materials make them ideal candidates for shielding metallic surfaces. For systems like cochlear implants the transmission of data as well as energy over an inductive link is conducted within a well-defined parameter set. For these systems, the shielding can be of particular importance if the properties of the link can be preserved. In this work, we investigate the effect of single and double-layered substrates consisting of ferrite and/or copper on the inductance and coupling of planar spiral coils. The examined link systems represent realistic configurations for active implantable systems such as cochlear implants. Experimental measurements are complemented with analytical calculations and finite element simulations, which are in good agreement for all measured parameters. The results are then used to study the transfer efficiency of an inductive link in a series–parallel resonant topology as a function of substrate size, the number of coil turns and coil separation. We find that ferrite sheets can be used to shield the system from unwanted metallic surfaces and to retain the inductive link parameters of the unperturbed system, particularly its transfer efficiency. The required size of the ferrite plates is comparable to the size of the coils, which makes the setup suitable for practical implementations. Since the sizes and geometries chosen for the studied inductive links are comparable to those of cochlear implants, our conclusions apply in particular to these systems.
- Open Access
- 24 October 2016
- Published by Springer Nature in EURASIP Journal on Audio, Speech, and Music Processing
- Vol. 2016 (1) , 17
Fast fundamental frequency determination via adaptive autocorrelation
- 24 October 2016
- Published by Springer Nature in EURASIP Journal on Audio, Speech, and Music Processing
- Vol. 2016 (1) , 17
Open AccessFast fundamental frequency determination via adaptive autocorrelation
- 3 February 2006
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 96 (4) , 043003
Feedback Cooling of a Single Trapped Ion
Based on a real-time measurement of the motion of a single ion in a Paul trap, we demonstrate its electromechanical cooling below the Doppler limit by homodyne feedback control (cold damping). The feedback cooling results are well described by a model based on a quantum mechanical master equation.
- 3 February 2006
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 96 (4) , 043003
Feedback Cooling of a Single Trapped Ion
Based on a real-time measurement of the motion of a single ion in a Paul trap, we demonstrate its electromechanical cooling below the Doppler limit by homodyne feedback control (cold damping). The feedback cooling results are well described by a model based on a quantum mechanical master equation.
- 2 December 2005
- Published by American Physical Society (APS) in Physical Review A
- Vol. 72 (6) , 069902
Publisher's Note: Quantum-limited velocity readout and quantum feedback cooling of a trapped ion via electromagnetically induced transparency [Phys. Rev. A72, 043823 (2005)]
DOI:https://doi.org/10.1103/PhysRevA.72.069902
- 2 December 2005
- Published by American Physical Society (APS) in Physical Review A
- Vol. 72 (6) , 069902
Publisher's Note: Quantum-limited velocity readout and quantum feedback cooling of a trapped ion via electromagnetically induced transparency [Phys. Rev. A72, 043823 (2005)]
DOI:https://doi.org/10.1103/PhysRevA.72.069902
- 31 October 2005
- Published by American Physical Society (APS) in Physical Review A
- Vol. 72 (4) , 043826
Quantum feedback cooling of a single trapped ion in front of a mirror
We develop a theory of quantum feedback cooling of a single ion trapped in front of a mirror. By monitoring the motional sidebands of the light emitted into the mirror mode we infer the position of the ion, and act back with an appropriate force to cool the ion. We derive a feedback master equation along the lines of the quantum feedback theory developed by Wiseman and Milburn, which provides us with cooling times and final temperatures as a function of feedback gain and various system parameters.
- 31 October 2005
- Published by American Physical Society (APS) in Physical Review A
- Vol. 72 (4) , 043826
Quantum feedback cooling of a single trapped ion in front of a mirror
We develop a theory of quantum feedback cooling of a single ion trapped in front of a mirror. By monitoring the motional sidebands of the light emitted into the mirror mode we infer the position of the ion, and act back with an appropriate force to cool the ion. We derive a feedback master equation along the lines of the quantum feedback theory developed by Wiseman and Milburn, which provides us with cooling times and final temperatures as a function of feedback gain and various system parameters.
- 27 October 2005
- Published by American Physical Society (APS) in Physical Review A
- Vol. 72 (4) , 043823
Quantum-limited velocity readout and quantum feedback cooling of a trapped ion via electromagnetically induced transparency
We discuss continuous observation of the momentum of a single atom by employing the high velocity sensitivity of the index of refraction in a driven -system based on electromagnetically induced transparency. In the ideal limit of unit collection efficiency this provides a quantum-limited measurement with minimal backaction on the atomic motion. A feedback loop, which drives the atom with a force proportional to measured signal, provides a cooling mechanism for the atomic motion. We derive the master equation which describes the feedback cooling and show that in the Lamb-Dicke limit the steady state energies are close to the ground state, limited only by the photon collection efficiency. Outside of the Lamb-Dicke regime the predicted temperatures are well below the Doppler limit.- 27 October 2005
- Published by American Physical Society (APS) in Physical Review A
- Vol. 72 (4) , 043823
Quantum-limited velocity readout and quantum feedback cooling of a trapped ion via electromagnetically induced transparency
We discuss continuous observation of the momentum of a single atom by employing the high velocity sensitivity of the index of refraction in a driven -system based on electromagnetically induced transparency. In the ideal limit of unit collection efficiency this provides a quantum-limited measurement with minimal backaction on the atomic motion. A feedback loop, which drives the atom with a force proportional to measured signal, provides a cooling mechanism for the atomic motion. We derive the master equation which describes the feedback cooling and show that in the Lamb-Dicke limit the steady state energies are close to the ground state, limited only by the photon collection efficiency. Outside of the Lamb-Dicke regime the predicted temperatures are well below the Doppler limit.