Jyoti Ranjan Nayak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jyoti Ranjan Nayak has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Binod Kumar Sahu
Department of Electrical Engineering, FET, ITER, Siksha ‘O’ Anusandhan Deemed to be University, Bhubaneswar, India
14 shared publications Binod Shaw
National Institute of Technology
11 shared publicationsTridipta Kumar Pati
7 shared publications- Sanjeeb Kumar Kar
Siksha ‘O’ Anusandhan (Deemed to be University)
3 shared publications - Amiya Naik
Department of Electrical Engineering, ITER, Siksha O Anusandhan Deemed to be University, Bhubaneswar, India
2 shared publications - Jugajyoti Sahu
Department of Electrical Engineering, ITER, Siksha O Anusandhan Deemed to be University, Bhubaneswar, India
2 shared publications
Latest Publications
- 14 August 2024
- Published by Springer Nature in Evolving Systems
- Vol. 15 (6) , 2169-2191
Short-term electric load forecasting using empirical mode decomposition based optimized extreme learning machine
- 14 August 2024
- Published by Springer Nature in Evolving Systems
- Vol. 15 (6) , 2169-2191
Short-term electric load forecasting using empirical mode decomposition based optimized extreme learning machine
- 3 October 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (1) , 1053-1077
Optimally designed fuzzy-based controller using Craziness-based CSA technique for AGC performance enhancement of power system
- 3 October 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (1) , 1053-1077
Optimally designed fuzzy-based controller using Craziness-based CSA technique for AGC performance enhancement of power system
- 19 September 2022
- Published by Springer Nature
- p. 223-232
Design of Quasi-Oppositional-Based CSA Optimized Cascade Pi-Fractional Order PID Controller for Interconnected Power System
- 19 September 2022
- Published by Springer Nature
- p. 223-232
Design of Quasi-Oppositional-Based CSA Optimized Cascade Pi-Fractional Order PID Controller for Interconnected Power System
- Open Access
- 1 September 2022
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 33, 101071
Fuzzy adaptive selfish herd optimization based optimal sliding mode controller for frequency stability enhancement of a microgrid
- 1 September 2022
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 33, 101071
Open AccessFuzzy adaptive selfish herd optimization based optimal sliding mode controller for frequency stability enhancement of a microgrid
- Open Access
- 4 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (13) , 2430-2440
Implementation of hybrid SSA–SA based three‐degree‐of‐freedom fractional‐order PID controller for AGC of a two‐area power system integrated with small hydro plants
In this work, a comparative study is analysed between the fractional‐order controllers such as fractional‐order proportional–integral–derivative (FOPID), two‐degree‐of‐freedom proportional–integral–derivative (DOF FOPID) and 3DOF FOPID, and conventional controllers such as proportional–integral–derivative (PID), 2DOF PID and 3DOF PID employed in automatic generation control (AGC) in power system. The proposed 3DOF FOPID controller is validated as superior one among all other controllers. The gains of all the controllers are optimally plucked by novel salp swarm algorithm (SSA). Further, hybrid salp swarm algorithm–simulated annealing (hSSA‐SA) algorithm is introduced to enhance the proficiency of 3DOF FOPID controller by sensibly plucking the gain parameters. The proposed approaches are implemented in a two‐area thermal‐hydro‐diesel system. Small hydro plants (SHPs) of similar characteristics are enforced in both areas with their dynamic responses by conceding frequency deviations of each area. Further, sensitivity and robustness analysis of the system with and without SHP are observed by varying some important parameters of the system. Finally, the supremacy of three novel approaches (fractional based controllers, hSSA‐SA and SHP) is substantiated gracefully.
- 4 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (13) , 2430-2440
Open AccessImplementation of hybrid SSA–SA based three‐degree‐of‐freedom fractional‐order PID controller for AGC of a two‐area power system integrated with small hydro plants
In this work, a comparative study is analysed between the fractional‐order controllers such as fractional‐order proportional–integral–derivative (FOPID), two‐degree‐of‐freedom proportional–integral–derivative (DOF FOPID) and 3DOF FOPID, and conventional controllers such as proportional–integral–derivative (PID), 2DOF PID and 3DOF PID employed in automatic generation control (AGC) in power system. The proposed 3DOF FOPID controller is validated as superior one among all other controllers. The gains of all the controllers are optimally plucked by novel salp swarm algorithm (SSA). Further, hybrid salp swarm algorithm–simulated annealing (hSSA‐SA) algorithm is introduced to enhance the proficiency of 3DOF FOPID controller by sensibly plucking the gain parameters. The proposed approaches are implemented in a two‐area thermal‐hydro‐diesel system. Small hydro plants (SHPs) of similar characteristics are enforced in both areas with their dynamic responses by conceding frequency deviations of each area. Further, sensitivity and robustness analysis of the system with and without SHP are observed by varying some important parameters of the system. Finally, the supremacy of three novel approaches (fractional based controllers, hSSA‐SA and SHP) is substantiated gracefully.
- 13 March 2020
- Published by Springer Nature
- p. 1-10
Fractional-Order PID Controller Optimized by SCA for Solar System
- 13 March 2020
- Published by Springer Nature
- p. 1-10
Fractional-Order PID Controller Optimized by SCA for Solar System
- 5 March 2020
- Published by Elsevier in Journal of Engineering Research
- Vol. 8 (1)
Hybrid alopex based DECRPSO algorithm optimized Fuzzy-PID controller for AGC
This paper is corroborated the hybrid Alopex based DECRPSO algorithm (ADECRPSO) over DE, ADE, PSO, and CRPSO algorithms to pursuit the gain parameters of the PID and Fuzzy PID (FPID) controller. In a two area thermal-hydro-diesel power system, primacy of FPID controller is endorsed with PID controller tuned with assorted techniques. The hybrid ADECRPSO algorithm is affirmed over above mentioned algorithms to tune PID controller in a two area hydro-thermal system. PSO, DE, CRPSO, ADE and ADECRPSO are executed individually to optimize the controller to enhance the transient analysis by conceding undershoot, overshoot, and settling time of the system. The compilation of advantages of alopex based DE and craziness based PSO causes an adequate hybrid algorithm which enhances the performance of Automatic Generation Control (AGC). The step load uprise in area-1 is imposed to observe the activities of AGC. Undeniably, FPID controller optimized by ADECRPSO commits superior performance over PSO, DE, CRPSO, and ADE optimized controller as proposed AGC system. So, the modified mutation of DE by alopex scheme enhances the potentiality to tune the system variables.
- 5 March 2020
- Published by Elsevier in Journal of Engineering Research
- Vol. 8 (1)
Hybrid alopex based DECRPSO algorithm optimized Fuzzy-PID controller for AGC
This paper is corroborated the hybrid Alopex based DECRPSO algorithm (ADECRPSO) over DE, ADE, PSO, and CRPSO algorithms to pursuit the gain parameters of the PID and Fuzzy PID (FPID) controller. In a two area thermal-hydro-diesel power system, primacy of FPID controller is endorsed with PID controller tuned with assorted techniques. The hybrid ADECRPSO algorithm is affirmed over above mentioned algorithms to tune PID controller in a two area hydro-thermal system. PSO, DE, CRPSO, ADE and ADECRPSO are executed individually to optimize the controller to enhance the transient analysis by conceding undershoot, overshoot, and settling time of the system. The compilation of advantages of alopex based DE and craziness based PSO causes an adequate hybrid algorithm which enhances the performance of Automatic Generation Control (AGC). The step load uprise in area-1 is imposed to observe the activities of AGC. Undeniably, FPID controller optimized by ADECRPSO commits superior performance over PSO, DE, CRPSO, and ADE optimized controller as proposed AGC system. So, the modified mutation of DE by alopex scheme enhances the potentiality to tune the system variables.
- 13 February 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (5)
Novel application of optimal fuzzy‐adaptive symbiotic organism search‐based two‐degree‐of‐freedom fuzzy proportional integral derivative controller for automatic generation control study
A knowledgeable and intelligent control strategy for automatic generation control (AGC) is required to supply reliable, secure, and stable power in most complex power system. So a proficient controller for AGC is indispensable to supply quality power with frequent load demand divergence. A novel two degree of freedom optimized fuzzy PID (2DOF OFPID) controller is proposed for the purpose to counterbalance generation and demand power expeditiously. This proposed controller is incorporated by blending the benefits of 2DOF PID and optimized fuzzy logic controller (FLC). The parameters and rules of proposed controller are decided by symbiotic organism search (SOS) and proposed passing vehicle search optimized fuzzy‐based SOS (PVSOFSOS) algorithms. In this work, the decisive parameters of SOS algorithm are decided by FLC. The rules of FLC in proposed algorithm are decided by PVS algorithm. The preeminence of proposed algorithm over SOS and PVS algorithms is demonstrated by resolving 12 benchmark functions (constraint and unconstrained). Further, the proposed approaches are implemented in two‐area and three‐area thermal power systems with load variation enforced in area 1. The effectiveness of the proposed approaches are graded by conceding maximum undershoot/overshoot and settling time. Sensitivity analysis of the system with proposed optimal controller is validated with large variations of system parameters. It is observed that PVSOFSOS‐based 2DOF OFPID controller proposed for AGC is more adequate as compared to some recently proposed techniques.
- 13 February 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (5)
Novel application of optimal fuzzy‐adaptive symbiotic organism search‐based two‐degree‐of‐freedom fuzzy proportional integral derivative controller for automatic generation control study
A knowledgeable and intelligent control strategy for automatic generation control (AGC) is required to supply reliable, secure, and stable power in most complex power system. So a proficient controller for AGC is indispensable to supply quality power with frequent load demand divergence. A novel two degree of freedom optimized fuzzy PID (2DOF OFPID) controller is proposed for the purpose to counterbalance generation and demand power expeditiously. This proposed controller is incorporated by blending the benefits of 2DOF PID and optimized fuzzy logic controller (FLC). The parameters and rules of proposed controller are decided by symbiotic organism search (SOS) and proposed passing vehicle search optimized fuzzy‐based SOS (PVSOFSOS) algorithms. In this work, the decisive parameters of SOS algorithm are decided by FLC. The rules of FLC in proposed algorithm are decided by PVS algorithm. The preeminence of proposed algorithm over SOS and PVS algorithms is demonstrated by resolving 12 benchmark functions (constraint and unconstrained). Further, the proposed approaches are implemented in two‐area and three‐area thermal power systems with load variation enforced in area 1. The effectiveness of the proposed approaches are graded by conceding maximum undershoot/overshoot and settling time. Sensitivity analysis of the system with proposed optimal controller is validated with large variations of system parameters. It is observed that PVSOFSOS‐based 2DOF OFPID controller proposed for AGC is more adequate as compared to some recently proposed techniques.