Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


José Ramón Lillo-Beviá has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Strength as a Predictor of Aerobic Power in Competitive Cyclists: National Team Insights

    by Alejandro Javaloyes, Cristóbal Sánchez-Muñoz, José-Antonio Salas-Montoro, José Ramón Lillo-Bevia, Manuel Moya-Ramón, Manuel Mateo-March

    Maximal aerobic power and time-to-exhaustion at maximal aerobic power are critical for cycling performance, yet the role of maximal lower-body strength in enhancing these metrics across sex, category, and discipline in cyclists remains underexplored. This study investigated the relationships between 1RM, maximal aerobic power, and time-to-exhaustion at maximal aerobic power in 69 high-level and professional cyclists from the same national team, stratified by sex, category, and discipline. Cyclists underwent a 2-day protocol to assess maximal aerobic power via a graded exercise test, time-to-exhaustion at maximal aerobic power, and 1RM via a velocity-based parallel back squat test. Spearman correlations, mixed models, generalized additive models, structural equation modeling, and cluster analysis examined strength–performance relationships, adjusted for covariates. 1RM strongly predicted maximal aerobic power (r=0.73, β=0.86, p<0.001; 2.47 W increase per kg) and relative 1RM predicted maximal aerobic power relative to body mass nonlinearly (r=0.58, β=0.84, p0.05). Women exhibited lower maximal aerobic power (−71.67 W, p<0.001), mountain bike cyclists showed longer time-to-exhaustion (+0.61 standard deviation, p=0.049), and elite cyclists had higher maximal aerobic power (+21.51 W, p=0.030), reflecting physiological and discipline-specific differences. Clusters highlighted strength-power distinctions. These findings demonstrate that maximal strength is associated with maximal aerobic power but not time-to-exhaustion, with associations varying according to sex, discipline, and category.


  • Open Access

    Torque–Cadence Profile and Maximal Dynamic Force in Cyclists: A Novel Approach

    by Víctor Rodríguez-Rielves, David Barranco-Gil, Ángel Buendía-Romero, Alejandro Hernández-Belmonte, Enrique Higueras-Liébana, Jon Iriberri, Iván R. Sánchez-Redondo, José Ramón Lillo-Beviá, Alejandro Martínez-Cava, Raúl de Pablos, et al.

    We aimed to determine the feasibility, test–retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load. To examine the test–retest reliability and long-term stability of torque–cadence values, the progressive test was repeated after 72 h and also after 10 weeks of aerobic and strength training. The participants’ MDF averaged 13.4 ± 1.3 N·kg−1, which was attained with an average pedal cadence of 21 ± 3 rpm. Participants’ highest power output value was attained with a cadence of 110 ± 16 rpm (52 ± 5% MDF). The relationship between the MDF and cadence proved to be very strong (R2 = 0.978) and independent of the cyclists’ MDF (p = 0.66). Cadence values derived from this relationship revealed a very high test–retest repeatability (mean SEM = 4 rpm, 3.3%) and long-term stability (SEM = 3 rpm, 2.3%); despite increases in the MDF following the 10-week period. Our findings support the validity, reliability and long-term stability of this method for the assessment of the torque–cadence profile and MDF in cyclists.


  • Open Access

    No evidence of association between HRV and training volume in a pool of professional athletes before, during, and after the first COVID-19 lockdown

    by A. Javaloyes, D. Marinazzo, D. Sanabria, M. Moya-Ramon, J.R. Lillo-Bevia, M. Mateo-March

  • Open Access

    Power Profile Index: An Adjustable Metric for Load Monitoring in Road Cycling

    by Manuel Mateo-March, José Ramón Lillo-Beviá, Gabriel della Mattia, Xabier Muriel, David Barranco-Gil, Mikel Zabala, Javier Courel-Ibáñez, José Antonio Salas-Montoro

    Workload is calculated from exercise volume and intensity. In endurance sports, intensity has been measured using heart rate or RPE, giving rise to load indexes such as sRPE or TRIMP. In cycling, the advent of power meters led to new indexes, such as TSS. All these indexes have limitations, especially for high intensity exercise. Therefore, a new index for cycling is proposed, the Power Profile Index (PPi), which includes a weighting factor obtained from the relative exercise intensity and stage type. Using power data from 67 WorldTour cyclists and fatigue records in different stage types from 102 road cyclists, weighting factors for intensity and stage type were determined. Subsequently, the PPi was computed and compared to current indexes using data from a WorldTour team during the 2018 Tour de France. The proposed index showed a strong correlation with perceived fatigue as a function of stage type (R2 = 0.9996), as well as no differences in the load quantification in different types of stage profiles (p = 0.292), something that does not occur with other indexes such as TSS, RPE, or eTRIMP (p < 0.001). Therefore, PPi is a new index capable of quantifying the high intensity efforts that produce greater fatigue, as well as considering the stage type.


  • Reproducibility of the Rotor 2INpower Crankset for Monitoring Cycling Power Output: A Comprehensive Analysis in Different Real-Context Situations

    by Víctor Rodríguez-Rielves, Alejandro Martínez-Cava, Ángel Buendía-Romero, José Ramón Lillo-Beviá, Javier Courel-Ibáñez, Alejandro Hernández-Belmonte, Jesús G. Pallarés

    Purpose: To examine the reproducibility (intradevice and interdevice agreement) of the Rotor 2INpower device under a wide range of cycling conditions. Methods: Twelve highly trained male cyclists and triathletes completed 5 cycling tests, including graded exercise tests at different cadences (70–100 rpm), workloads (100–650 W), pedaling positions (seated and standing), and vibration conditions (20–40 Hz) and an 8-second maximal sprint (>1000 W). An intradevice analysis included a comparison between the power output registered by 3 units of Rotor 2INpower, whereas the power output provided by each one of these units and the gold-standard SRM crankset were compared for the interdevice analysis. Among others, statistical calculations included the standard error of measurement, expressed in absolute (in watts) and relative terms as the coefficient of variation (CV). Results: Except for the graded exercise test seated at 100 rpm/100 W (CV = 10.2%), the intradevice analysis showed an acceptable magnitude of error (CV ≤ 6.9%, standard error of measurement ≤ 12.3 W) between the 3 Rotor 2INpower. Similarly, these 3 units showed an acceptable agreement with the gold standard in all graded exercise test situations (CV ≤ 4.0%, standard error of measurement ≤ 13.1 W). On the other hand, both the intradevice and interdevice agreements proved to be slightly reduced under high cadences (intradevice: CV ≤ 10.2%; interdevice: CV ≤ 4.0%) and vibration (intradevice: CV ≤ 4.0%; interdevice: CV ≤ 3.6%), as well as during standing pedaling (intradevice: CV ≤ 4.1%; interdevice: CV ≤ 2.5%). Although within the limits of an acceptable agreement, measurement errors increased during the sprint tests (CV ≤ 7.4%). Conclusions: Based on these results, the Rotor 2INpower could be considered a reproducible tool to monitor power output in most cycling situations.


  • Open Access

    Are the Assioma Favero Power Meter Pedals a Reliable Tool for Monitoring Cycling Power Output?

    by Víctor Rodríguez-Rielves, José Ramón Lillo-Beviá, Ángel Buendía-Romero, Alejandro Martínez-Cava, Alejandro Hernández-Belmonte, Javier Courel-Ibáñez, Jesús G. Pallarés

    This study aimed to examine the validity and reliability of the recently developed Assioma Favero pedals under laboratory cycling conditions. In total, 12 well-trained male cyclists and triathletes (VO2max = 65.7 ± 8.7 mL·kg−1·min−1) completed five cycling tests including graded exercises tests (GXT) at different cadences (70–100 revolutions per minute, rpm), workloads (100–650 Watts, W), pedaling positions (seated and standing), vibration stress (20–40 Hz), and an 8-s maximal sprint. Tests were completed using a calibrated direct drive indoor trainer for the standing, seated, and vibration GXTs, and a friction belt cycle ergometer for the high-workload step protocol. Power output (PO) and cadence were collected from three different brand, new pedal units against the gold-standard SRM crankset. The three units of the Assioma Favero exhibited very high within-test reliability and an extremely high agreement between 100 and 250 W, compared to the gold standard (Standard Error of Measurement, SEM from 2.3–6.4 W). Greater PO produced a significant underestimating trend (p < 0.05, Effect size, ES ≥ 0.22), with pedals showing systematically lower PO than SRM (1–3%) but producing low bias for all GXT tests and conditions (1.5–7.4 W). Furthermore, vibrations ≥ 30 Hz significantly increased the differences up to 4% (p < 0.05, ES ≥ 0.24), whereas peak and mean PO differed importantly between devices during the sprints (p < 0.03, ES ≥ 0.39). These results demonstrate that the Assioma Favero power meter pedals provide trustworthy PO readings from 100 to 650 W, in either seated or standing positions, with vibrations between 20 and 40 Hz at cadences of 70, 85, and 100 rpm, or even at a free chosen cadence.


  • Time to exhaustion during cycling is not well predicted by critical power calculations

    by Jesus G. Pallarés, Jose R. Lillo-Bevia, Ricardo Morán-Navarro, Victor Cerezuela-Espejo, Ricardo Mora-Rodriguez

    Three to 5 cycling tests to exhaustion allow prediction of time to exhaustion (TTE) at power output based on calculation of critical power (CP). We aimed to determine the accuracy of CP predictions of TTE at power outputs habitually endured by cyclists. Fourteen endurance-trained male cyclists underwent 4 randomized cycle-ergometer TTE tests at power outputs eliciting (i) mean Wingate anaerobic test (WAnTmean), (ii) maximal oxygen consumption, (iii) respiratory compensation threshold (VT2), and (iv) maximal lactate steady state (MLSS). Tests were conducted in duplicate with coefficient of variation of 5%–9%. Power outputs were 710 ± 63 W for WAnTmean, 366 ± 26 W for maximal oxygen consumption, 302 ± 31 W for VT2 and 247 ± 20 W for MLSS. Corresponding TTE were 00:29 ± 00:06, 03:23 ± 00:45, 11:29 ± 05:07, and 76:05 ± 13:53 min:s, respectively. Power output associated with CP was only 2% lower than MLSS (242 ± 19 vs. 247 ± 20 W; P < 0.001). The CP predictions overestimated TTE at WAnTmean (00:24 ± 00:10 mm:ss) and MLSS (04:41 ± 11:47 min:s), underestimated TTE at VT2 (–04:18 ± 03:20 mm:ss; P < 0.05), and correctly predicted TTE at maximal oxygen consumption. In summary, CP accurately predicts MLSS power output and TTE at maximal oxygen consumption. However, it should not be used to estimate time to exhaustion in trained cyclists at higher or lower power outputs (e.g., sprints and 40-km time trials). Novelty CP calculation enables to predict TTE at any cycling power output. We tested those predictions against measured TTE in a wide range of cycling power outputs. CP appropriately predicted TTE at maximal oxygen consumption intensity but err at higher and lower cycling power outputs.


  • Is the Functional Threshold Power a Valid Metric to Estimate the Maximal Lactate Steady State in Cyclists?

    by José Ramón Lillo-Beviá, Javier Courel-Ibáñez, Victor Cerezuela-Espejo, Ricardo Morán-Navarro, Alejandro Martínez-Cava, Jesús G. Pallarés

    Lillo-Beviá, JR, Courel-Ibáñez, J, Cerezuela-Espejo, V, Morán-Navarro, R, Martínez-Cava, A, and Pallarés, JG. Is the functional threshold power a valid metric to estimate the maximal lactate steady state in cyclists? J Strength Cond Res 36(1): 167–173, 2022—The aims of this study were to determine (a) the repeatability of a 20-minute time-trial (TT20), (b) the location of the TT20 in relation to the main physiological events of the aerobic-anaerobic transition, and (c) the predictive power of a list of correction factors and linear/multiple regression analysis applied to the TT20 result to estimate the individual maximal lactate steady state (MLSS). Under laboratory conditions, 11 trained male cyclists and triathletes (V̇ o 2 max 59.7 ± 3.0 ml·kg −1 ·min −1 ) completed a maximal graded exercise test to record the power output associated with the first and second ventilatory thresholds and V̇ o 2 max measured by indirect calorimetry, several 30 minutes constant tests to determine the MLSS, and 2 TT20 tests with a short warm-up. Very high repeatability of TT20 tests was confirmed (standard error of measurement of ±3 W and smallest detectable change of ±9 W). Validity results revealed that MLSS differed substantially from TT20 (bias = 26 ± 7 W). The maximal lactate steady state was then estimated from the traditional 95% factor (bias = 12 ± 7 W) and a novel individual correction factor (ICF% = MLSS/TT20), resulting in 91% (bias = 1 ± 6 W). Complementary linear (MLSS = 0.7488 × TT20 + 43.24; bias = 0 ± 5 W) and multiple regression analysis (bias = 0 ± 4 W) substantially improved the individual MLSS workload estimation. These findings suggest reconsidering the TT20 procedures and calculations to increase the effectiveness of the MLSS prediction.


  • Validity and Reliability of the Cycleops Hammer Cycle Ergometer

    by José R. Lillo-Bevia, Jesús G. Pallarés

    Purpose: To validate the new drive indoor trainer Hammer designed by Cycleops®. Methods: A total of 11 cyclists performed 44 randomized and counterbalanced graded exercise tests (100–500 W) at 70-, 85-, and 100-rpm cadences in seated and standing positions on 3 different Hammer units, while a scientific SRM system continuously recorded cadence and power output data. Results: No significant differences were detected between the 3 Hammer devices and the SRM for any workload, cadence, or pedaling condition (P value between 1.00 and .350), except for some minor differences (P = .03 and .04) found in the Hammer 1 at low workloads and for Hammer 2 and 3 at high workloads, all in seated position. Strong intraclass correlation coefficients were found between the power output values recorded by the Hammers and the SRM (≥.996; P = .001), independently from the cadence condition and seated position. Bland–Altman analysis revealed low bias (−5.5 to 3.8) and low SD of bias (2.5–5.3) for all testing conditions, except marginal values found for the Hammer 1 at high cadences and seated position (9.6 [6.6]). High absolute reliability values were detected for the 3 Hammers (150–500 W; coefficient of variation Conclusions: This new Cycleops trainer is a valid and reliable device to drive and measure power output in cyclists, providing an alternative to larger and more expensive laboratory ergometers and allowing cyclists to use their own bicycles.


  • Open Access

    A 1-day maximal lactate steady-state assessment protocol for trained cyclists

    by Jose Ramon Lillo-Bevia, Ricardo Moran-Navarro, Alejandro Martinez-Cava, Victor Cerezuela, Jesus G. Pallares

    The main aim of this study is to assess the validity of a new cycling protocol to estimate the Maximal Lactate Steady-State workload (MLSS) through a one-day incremental protocol (1day_MLSS). Eleven well-trained male cyclists performed 3 to 4 trials of 30-min constant load test (48-72h in between) to determine their respective MLSS workload. Then, on separate days, each cyclist carried out two identical graded exercise tests, comprised of four 10-minute long stages, with the initial load at 63% of their respective maximal aerobic power, 0.2 W·Kg-1 increments, and blood lactate concentration (BLC) determinations each 5 min. The results of the 1day_MLSS tests were analysed through three different constructs: i) BLC difference between 5th and 10th min of each stage (DIF_5to10), ii) BLC difference between the 10th min of two consecutive stages (DIF_10to10), and iii) difference in the mean BLC between the 5th and 10th min of two consecutive stages (DIF_mean). For all constructs, the physiological steady state was determined as the highest workload that could be maintained with a BLC rise lower than 1mmol·L-1. No significant differences were detected between the MLSS workload (247 ± 22W) and any of the 1day_MLSS data analysis (250 ± 24W, 245 ± 23W and 243 ± 21W, respectively; p>0.05). When compared to the MLSS workload, strong ICCs and low bias values were found for these three constructs, especially for the DIF_10to10 workload (r=0.960; Bias=2.2 W). High within-subject reliability data were found for the DIF10_10 construct (ICC=0.846; CV=0.4%; Bias=2.2 ± 6.4W). The 1day_MLSS test and DIF_10to10 data analysis is a valid assessment to predict the MLSS workload in cycling, that considerably reduces the dedicated time, effort and human resources that requires the original test. The validity and reliability values reported in this project are higher than those achieved by other previous MLSS estimation tests.