Hatam Amanzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hatam Amanzadeh has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Yadollah Yamini
Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
7 shared publications - Khalil Farhadi
Department of Analytical Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iran
4 shared publications Morteza Moradi
Department of Semiconductors, Materials and Energy Research Center, Karaj, Iran
3 shared publicationsPourya Biparva
Department of Basic Sciences, Sari Agricultural Sciences and Natural Resources University, Sari, Iran
3 shared publicationsAli Morsali
Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
2 shared publicationsAmir Abbas Farshid
Department of Pathobiology, Faculty of Veterinary Medicine, Urmia University, Urmia, Iran
2 shared publications
Latest Publications
- 18 December 2017
- Published by Springer Nature in Microchimica Acta
- Vol. 185 (1) , 62
A nanocomposite prepared from a zinc-based metal-organic framework and polyethersulfone as a novel coating for the headspace solid-phase microextraction of organophosphorous pesticides
The authors describe a zinc-based metal-organic framework/polyethersulfone nanocomposite (TMU-4/PES) coating deposited on a stainless steel wire via a single-phase inversion method. The nanocomposite represents a novel fiber coating for headspace solid-phase microextraction of organophosphorous pesticides (OPPs) from environmental water and soil samples. The synergistic effects of the high surface area and unique porous structure of TMU-4 as well as the rich π electron stacking and mechanical attributes of the PES polymer result in a high affinity of the composite for OPPs. Following thermal desorption, the OPPS were quantified by gas chromatography with a nitrogen-phosphorus detector. The preparation of the coating is simple, and the coated fiber is highly stable and reusable in that it can be used in about 100 consecutive extractions/desorption cycles. A central composite design was used for assessing the effect of the experimental parameters on the extraction process. Under optimized conditions, the limits of detection are in the 5–8 ng mL−1 range for the OPPs diazinon, fenitrothion, malathion and chlorpyrifos. The average repeatability and fiber-to-fiber reproducibility are 6.5% and 8.7%, respectively. The method was applied to the trace determination of OPPs in (spiked) water and soil samples where it gave good recovery (88–108%) and satisfactory reproducibility (5.9–10.1%).
- 18 December 2017
- Published by Springer Nature in Microchimica Acta
- Vol. 185 (1) , 62
A nanocomposite prepared from a zinc-based metal-organic framework and polyethersulfone as a novel coating for the headspace solid-phase microextraction of organophosphorous pesticides
The authors describe a zinc-based metal-organic framework/polyethersulfone nanocomposite (TMU-4/PES) coating deposited on a stainless steel wire via a single-phase inversion method. The nanocomposite represents a novel fiber coating for headspace solid-phase microextraction of organophosphorous pesticides (OPPs) from environmental water and soil samples. The synergistic effects of the high surface area and unique porous structure of TMU-4 as well as the rich π electron stacking and mechanical attributes of the PES polymer result in a high affinity of the composite for OPPs. Following thermal desorption, the OPPS were quantified by gas chromatography with a nitrogen-phosphorus detector. The preparation of the coating is simple, and the coated fiber is highly stable and reusable in that it can be used in about 100 consecutive extractions/desorption cycles. A central composite design was used for assessing the effect of the experimental parameters on the extraction process. Under optimized conditions, the limits of detection are in the 5–8 ng mL−1 range for the OPPs diazinon, fenitrothion, malathion and chlorpyrifos. The average repeatability and fiber-to-fiber reproducibility are 6.5% and 8.7%, respectively. The method was applied to the trace determination of OPPs in (spiked) water and soil samples where it gave good recovery (88–108%) and satisfactory reproducibility (5.9–10.1%).
- 13 December 2017
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 54 (5) , 507-510
Electrophoretic deposition of ordered mesoporous carbon nitride on a stainless steel wire as a high-performance solid phase microextraction coating
An electrophoretic deposition approach was developed to fabricate a robust ordered mesoporous carbon nitride (MCN) coating for solid-phase microextraction.
- 13 December 2017
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 54 (5) , 507-510
Electrophoretic deposition of ordered mesoporous carbon nitride on a stainless steel wire as a high-performance solid phase microextraction coating
An electrophoretic deposition approach was developed to fabricate a robust ordered mesoporous carbon nitride (MCN) coating for solid-phase microextraction.
- 11 September 2017
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 41 (20) , 12035-12043
Nanostructured metal–organic frameworks, TMU-4, TMU-5, and TMU-6, as novel adsorbents for solid phase microextraction of polycyclic aromatic hydrocarbons
In the current study, three zinc(II) based metal–organic frameworks with different ligands, namely, TMU-4, TMU-5, and TMU-6, were prepared and coated onto the surface of stainless steel (SS) wire. Their applications were evaluated for the headspace solid phase microextraction (HS-SPME) of polycyclic aromatic hydrocarbons (PAHs) from water and soil samples. Due to the large surface area and unique porous structure of the MOFs as well as hydrophobic effects and π–π stacking interactions between the analytes and the MOF ligands, the prepared coated fibers showed a high affinity towards the PAHs. Among the three MOF coatings, the TMU-6 was the best candidate for the preconcentration of the PAHs. The TMU-6 coated fiber exhibited a long lifetime and high reusability for the analysis of PAHs; a single fiber could be used for about 60 consecutive extraction/desorption cycles without any significant loss of its extraction performance. Under the optimized conditions, low limits of detection (0.005–0.008 μg L−1) and a wide linear range (0.02–50 μg L−1) were obtained for the determination of PAHs in aqueous samples. Finally, the method was applied to the trace analysis of the PAHs in river water, hookah water, and soil samples, and relative recoveries in the range of 89–105% with relative standard deviations (RSDs) ranging from 5.3% to 9.6% (n = 3) were obtained. Single fiber repeatability and fiber-to-fiber reproducibility values expressed as RSDs were in the ranges of 5.9–7.9% and 8.6–10.4%, respectively.
- 11 September 2017
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 41 (20) , 12035-12043
Nanostructured metal–organic frameworks, TMU-4, TMU-5, and TMU-6, as novel adsorbents for solid phase microextraction of polycyclic aromatic hydrocarbons
In the current study, three zinc(II) based metal–organic frameworks with different ligands, namely, TMU-4, TMU-5, and TMU-6, were prepared and coated onto the surface of stainless steel (SS) wire. Their applications were evaluated for the headspace solid phase microextraction (HS-SPME) of polycyclic aromatic hydrocarbons (PAHs) from water and soil samples. Due to the large surface area and unique porous structure of the MOFs as well as hydrophobic effects and π–π stacking interactions between the analytes and the MOF ligands, the prepared coated fibers showed a high affinity towards the PAHs. Among the three MOF coatings, the TMU-6 was the best candidate for the preconcentration of the PAHs. The TMU-6 coated fiber exhibited a long lifetime and high reusability for the analysis of PAHs; a single fiber could be used for about 60 consecutive extraction/desorption cycles without any significant loss of its extraction performance. Under the optimized conditions, low limits of detection (0.005–0.008 μg L−1) and a wide linear range (0.02–50 μg L−1) were obtained for the determination of PAHs in aqueous samples. Finally, the method was applied to the trace analysis of the PAHs in river water, hookah water, and soil samples, and relative recoveries in the range of 89–105% with relative standard deviations (RSDs) ranging from 5.3% to 9.6% (n = 3) were obtained. Single fiber repeatability and fiber-to-fiber reproducibility values expressed as RSDs were in the ranges of 5.9–7.9% and 8.6–10.4%, respectively.
- 1 February 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 953, 1-9
A new generation of nano-structured supramolecular solvents based on propanol/gemini surfactant for liquid phase microextraction
- 1 February 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 953, 1-9
A new generation of nano-structured supramolecular solvents based on propanol/gemini surfactant for liquid phase microextraction
- 1 September 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1465, 38-46
Determination of phthalate esters in drinking water and edible vegetable oil samples by headspace solid phase microextraction using graphene/polyvinylchloride nanocomposite coated fiber coupled to gas chromatography-flame ionization detector
- 1 September 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1465, 38-46
Determination of phthalate esters in drinking water and edible vegetable oil samples by headspace solid phase microextraction using graphene/polyvinylchloride nanocomposite coated fiber coupled to gas chromatography-flame ionization detector
- 1 November 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1419, 10-18
Dynamic electromembrane extraction: Automated movement of donor and acceptor phases to improve extraction efficiency
- 1 November 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1419, 10-18
Dynamic electromembrane extraction: Automated movement of donor and acceptor phases to improve extraction efficiency