Abel Ibrahim Balbín Tamayo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abel Ibrahim Balbín Tamayo has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Ana Margarita Esteva Guas
Department of Analytical Chemistry, Faculty of Chemistry, University of Havana, Zapata s/n between G and Carlitos Aguirre, Vedado, Plaza de la Revolución, CP 10400. Havana, Cuba
2 shared publications- Baolin Liu
USST-UH International Joint Laboratory for Tumor Diagnosis and Energy Treatment, University of Shanghai for Science and Technology, Shanghai 200093, China; School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
2 shared publications Lan Jiang
Institute of Bismuth and Rhenium Science, School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, China
2 shared publications- Leodanis Correa Fajardo
Department of Analytical Chemistry, Faculty of Chemistry, University of Havana, Havana, Cuba
2 shared publications - Ruizhuo Ouyang
Institute of Bismuth and Rhenium Science, University of Shanghai for Science and Technology, Shanghai, 200093, China; USST-UH International Joint Laboratory for Tumor Diagnosis and Energy Treatment, University of Shanghai for Science and Technology, Shanghai, 200093, China
2 shared publications Xianjin Xie
Institute of Bismuth and Rhenium Science, School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 18 September 2025
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Chemical Engineering
- Vol. 69 (3) , 493-499
Screen-printed Potentiometric Selective Electrode Based on an Ammonium Quaternary Salt for Nitrate Detection
In this study, a screen-printed electrode for nitrate ions was evaluated with a selective membrane based on tetradecyl ammonium nitrate as the ionophore, o-nitrophenyl octyl ether as the plasticizer, and polyvinyl chloride as the polymeric matrix. The electrodes were printed on polyethylene terephthalate sheets using a screen-printing frame with the electrode template. Then, the selective membrane was deposited by drop casting. The principal analytical parameters were determined by the method of additions recommended by IUPAC. The membrane showed a good linear response range of 5.38 × 10−6 to 1 × 10−2 mol/L, being Nernstian according to the slope of −57.13 mV/dec (theoretical slope: −59.16 mV/dec), with a practical detection limit of 2.96 × 10−6 mol/L and a lower limit of linear response of 5.38 × 10−6 mol/L. The potentiometric selectivity coefficients for Cl−, Br−, I−, SO42−, and IO3− ions were determined using the mixed solutions method. The Br− ion was found to be the most relevant interferent. The electrode showed a fast stable response (20 s), as well as the possibility of use in a wide pH range (3–12) without compromising the potentiometric response.
- 18 September 2025
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Chemical Engineering
- Vol. 69 (3) , 493-499
Open AccessScreen-printed Potentiometric Selective Electrode Based on an Ammonium Quaternary Salt for Nitrate Detection
In this study, a screen-printed electrode for nitrate ions was evaluated with a selective membrane based on tetradecyl ammonium nitrate as the ionophore, o-nitrophenyl octyl ether as the plasticizer, and polyvinyl chloride as the polymeric matrix. The electrodes were printed on polyethylene terephthalate sheets using a screen-printing frame with the electrode template. Then, the selective membrane was deposited by drop casting. The principal analytical parameters were determined by the method of additions recommended by IUPAC. The membrane showed a good linear response range of 5.38 × 10−6 to 1 × 10−2 mol/L, being Nernstian according to the slope of −57.13 mV/dec (theoretical slope: −59.16 mV/dec), with a practical detection limit of 2.96 × 10−6 mol/L and a lower limit of linear response of 5.38 × 10−6 mol/L. The potentiometric selectivity coefficients for Cl−, Br−, I−, SO42−, and IO3− ions were determined using the mixed solutions method. The Br− ion was found to be the most relevant interferent. The electrode showed a fast stable response (20 s), as well as the possibility of use in a wide pH range (3–12) without compromising the potentiometric response.
- Open Access
- 16 June 2025
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 15 (4) , 2751
Development of graphite-epoxy screen-printed electrodes selective to nitrate ions
High concentrations of nitrate ions in water can cause eutrophication, while ingestion of these ions can cause methemoglobin and various cancers. Therefore, there is a need for sensitive, selective and inexpensive analytical tools, as an alternative to expensive conventional techniques, to monitor and evaluate the concentration of these ions. The aim of the present investigation is to develop printed graphite-epoxy electrodes modified with PVC membranes for the potentiometric determination of nitrate ions. The electrodes were manually printed in the laboratory with inks prepared from epoxy resin and graphite at different percentages and particle sizes. The printed electrodes were characterized by cyclic voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy, prior to their modification with PVC membrane. The chrono-potentiometric response of the electrodes was evaluated with NO3- ion solutions. The best printing and electrochemical behavior of electrodes was obtained with inks containing 76 % of modified conductive phase-modified graphite nanoparticles. The developed ion-selective electrodes showed response to nitrate ions with a super-Nernstian slope, detection limits in the order of 10 mmol L-1, response times of 10 to 12 seconds and selectivity in the presence of NO2-, SO42-, Cl-, Br-, I- and CrO42- ions. The developed electrodes were used for the indirect determination of chloride ions in water samples by potentiometric titration.
- 16 June 2025
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 15 (4) , 2751
Open AccessDevelopment of graphite-epoxy screen-printed electrodes selective to nitrate ions
High concentrations of nitrate ions in water can cause eutrophication, while ingestion of these ions can cause methemoglobin and various cancers. Therefore, there is a need for sensitive, selective and inexpensive analytical tools, as an alternative to expensive conventional techniques, to monitor and evaluate the concentration of these ions. The aim of the present investigation is to develop printed graphite-epoxy electrodes modified with PVC membranes for the potentiometric determination of nitrate ions. The electrodes were manually printed in the laboratory with inks prepared from epoxy resin and graphite at different percentages and particle sizes. The printed electrodes were characterized by cyclic voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy, prior to their modification with PVC membrane. The chrono-potentiometric response of the electrodes was evaluated with NO3- ion solutions. The best printing and electrochemical behavior of electrodes was obtained with inks containing 76 % of modified conductive phase-modified graphite nanoparticles. The developed ion-selective electrodes showed response to nitrate ions with a super-Nernstian slope, detection limits in the order of 10 mmol L-1, response times of 10 to 12 seconds and selectivity in the presence of NO2-, SO42-, Cl-, Br-, I- and CrO42- ions. The developed electrodes were used for the indirect determination of chloride ions in water samples by potentiometric titration.
- 14 January 2023
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (2) , 1-12
Ti3C2@Bi2O3 nanoaccordion for electrochemical determination of miRNA-21
Based on a dual signal amplification strategy of novel accordion-like Bi2O3-decorated Ti3C2 (Ti3C2@Bi2O3) nanocomposites and hybridization chain reaction (HCR), an ultra-sensitive electrochemical biosensor was constructed for miRNA-21 detection. By etching Ti3AlC2 with HF, Ti3C2 with an accordion-like structure was first obtained and subsequently covered by Bi2O3 nanoparticles (NPs), forming Ti3C2@Bi2O3. A layer of Au NPs was electrodeposited on the glassy carbon electrode coated with Ti3C2@Bi2O3, which not only significantly improved the electron transport capacity of the electrode but also greatly increased its surface active area. Upon the immobilization of the thiolated capture probe (SH-CP) on the electrode, the target miRNA-21 specifically hybridized with SH-CP and thus opened its hairpin structure, triggering HCR to form a long double strand with the primers H1 and H2. A large number of the electrochemical indicator molecules were thus embedded inside the long double strands to produce the desirable electrochemical signal at a potential of − 0.19 V (vs. Ag/AgCl). Such dual signal amplification strategy successfully endowed the biosensor with ultra-high sensitivity for miRNA-21 detection in a wide linear range from 1 fM to 100 pM with a detection limit as low as 0.16 fM. The excellent detection of miRNA-21 in human blood plasma displayed a broad prospect in clinical diagnosis. Graphical Abstract An ultra-sensitive electrochemical biosensor was successfully constructed for miRNA-21 detection in human blood plasma based on the dual signal amplification strategy of novel accordion-like Bi2O3 decorated Ti3C2 (Ti3C2@Bi2O3) nanocomposites and hybridization chain reaction.
- 14 January 2023
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (2) , 1-12
Ti3C2@Bi2O3 nanoaccordion for electrochemical determination of miRNA-21
Based on a dual signal amplification strategy of novel accordion-like Bi2O3-decorated Ti3C2 (Ti3C2@Bi2O3) nanocomposites and hybridization chain reaction (HCR), an ultra-sensitive electrochemical biosensor was constructed for miRNA-21 detection. By etching Ti3AlC2 with HF, Ti3C2 with an accordion-like structure was first obtained and subsequently covered by Bi2O3 nanoparticles (NPs), forming Ti3C2@Bi2O3. A layer of Au NPs was electrodeposited on the glassy carbon electrode coated with Ti3C2@Bi2O3, which not only significantly improved the electron transport capacity of the electrode but also greatly increased its surface active area. Upon the immobilization of the thiolated capture probe (SH-CP) on the electrode, the target miRNA-21 specifically hybridized with SH-CP and thus opened its hairpin structure, triggering HCR to form a long double strand with the primers H1 and H2. A large number of the electrochemical indicator molecules were thus embedded inside the long double strands to produce the desirable electrochemical signal at a potential of − 0.19 V (vs. Ag/AgCl). Such dual signal amplification strategy successfully endowed the biosensor with ultra-high sensitivity for miRNA-21 detection in a wide linear range from 1 fM to 100 pM with a detection limit as low as 0.16 fM. The excellent detection of miRNA-21 in human blood plasma displayed a broad prospect in clinical diagnosis. Graphical Abstract An ultra-sensitive electrochemical biosensor was successfully constructed for miRNA-21 detection in human blood plasma based on the dual signal amplification strategy of novel accordion-like Bi2O3 decorated Ti3C2 (Ti3C2@Bi2O3) nanocomposites and hybridization chain reaction.
- Open Access
- 13 April 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (19) , 11867-11876
Rapid electrochemical detection of MiRNA-21 facilitated by the excellent catalytic ability of Pt@CeO2 nanospheres
New Pt@CeO2 nanospheres with advanced catalytic ability were successfully applied to fabricate a highly sensitive electrochemical RNA sensor for rapid detection of miRNA-21 in real blood samples.
- 13 April 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (19) , 11867-11876
Open AccessRapid electrochemical detection of MiRNA-21 facilitated by the excellent catalytic ability of Pt@CeO2 nanospheres
New Pt@CeO2 nanospheres with advanced catalytic ability were successfully applied to fabricate a highly sensitive electrochemical RNA sensor for rapid detection of miRNA-21 in real blood samples.
- Open Access
- 1 October 2021
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 11 (4) , 247-261
Characterization of graphite-epoxy composite electrodes for free electrochemical detection of adenine and guanine in DNA
Graphite-epoxy composites (GECs) are alternative construction materials for electrochemical sensors. For these materials, the electron transfer rate constant of some redox reaction depends additionally on the stoichiometric relationship between the insulating and conducting phases of the composite. In this work, the influence of different ratios of araldite/hardener/graphite on the electrochemical properties of GEC electrodes is evaluated for the simultaneous determination of adenine and guanine in the single chain DNA, using the square wave voltammetry technique. Six GEC electrodes were prepared with different ratios of components, and electrochemically characterized by cyclic voltammetry in the presence of ferri/ferrocyanide redox couple as a redox probe. GEC electrodes that showed the best electrochemical responses of redox probe were characterized by thermogravimetric analysis (TGA) and used for the simultaneous determination of free adenine and guanine in a solution, and DNA oligonucleotides. The best results were obtained for GEC electrodes containing twice higher volume of araldite resin with respect to the hardener. TGA analysis revealed presence of 15-26 % of resin for these GEC electrodes. The obtained results revealed potential application of these GEC electrodes as DNA sensors based on the oxidation signal of guanine.
- 1 October 2021
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 11 (4) , 247-261
Open AccessCharacterization of graphite-epoxy composite electrodes for free electrochemical detection of adenine and guanine in DNA
Graphite-epoxy composites (GECs) are alternative construction materials for electrochemical sensors. For these materials, the electron transfer rate constant of some redox reaction depends additionally on the stoichiometric relationship between the insulating and conducting phases of the composite. In this work, the influence of different ratios of araldite/hardener/graphite on the electrochemical properties of GEC electrodes is evaluated for the simultaneous determination of adenine and guanine in the single chain DNA, using the square wave voltammetry technique. Six GEC electrodes were prepared with different ratios of components, and electrochemically characterized by cyclic voltammetry in the presence of ferri/ferrocyanide redox couple as a redox probe. GEC electrodes that showed the best electrochemical responses of redox probe were characterized by thermogravimetric analysis (TGA) and used for the simultaneous determination of free adenine and guanine in a solution, and DNA oligonucleotides. The best results were obtained for GEC electrodes containing twice higher volume of araldite resin with respect to the hardener. TGA analysis revealed presence of 15-26 % of resin for these GEC electrodes. The obtained results revealed potential application of these GEC electrodes as DNA sensors based on the oxidation signal of guanine.
- 1 January 2018
- Published by MedCrave Group Kft. in International Journal of Biosensors & Bioelectronics
- Vol. 4 (5)
Free-label electrochemical detection of of HIV-1 proviral DNA in clinical sample
- 1 January 2018
- Published by MedCrave Group Kft. in International Journal of Biosensors & Bioelectronics
- Vol. 4 (5)
Free-label electrochemical detection of of HIV-1 proviral DNA in clinical sample
- Open Access
- 1 January 2018
- Published by MedCrave Group Kft. in International Journal of Biosensors & Bioelectronics
- Vol. 4 (4) , 1
Essential aspects in the design of electrochemical biosensors: mini review
- 1 January 2018
- Published by MedCrave Group Kft. in International Journal of Biosensors & Bioelectronics
- Vol. 4 (4) , 1
Open AccessEssential aspects in the design of electrochemical biosensors: mini review
- Open Access
- 5 December 2014
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 4 (4) , 145-154
Analytical method for heavy metal determination in algae and turtle eggs from Guanahacabibes Protected Sea Park
A standard digestion method coupled to electrochemical detection for the monitoring of heavy metals in biological samples has been used for the simultaneous analysis of the target analytes. Square wave anodic stripping voltammetry (SWASV) coupled to disposable screen-printed electrodes (SPEs) was employed as a fast and sensitive electroanalytical method for the detection of heavy metals. The aim of our study was to determine Cd, Pb and Cu by SWASV in brown algae (Sargasum natan) and green turtle eggs (Chelonia mydas) using screen-printed electrodes. The method proved useful for the simultaneous analysis of these metals by comparison between two different procedures for preparing the samples. Two different approaches in digestion protocols were assessed. The study was focused on Guanahacabibes brown algae and green turtle eggs because the metal concentrations recorded in this area may be used for intraspecific comparison within the Guanahacabibes Protected Sea Park area, a body of water for which information is still very scarce. The best results were obtained by digesting biological samples with the EPA 3050B method. This treatment allowed the fast and quantitative extraction from brown algae and green turtle eggs of the target analytes, with high sensitivity and avoiding organic residues, eventually affecting electrochemical measurements.
- 5 December 2014
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 4 (4) , 145-154
Open AccessAnalytical method for heavy metal determination in algae and turtle eggs from Guanahacabibes Protected Sea Park
A standard digestion method coupled to electrochemical detection for the monitoring of heavy metals in biological samples has been used for the simultaneous analysis of the target analytes. Square wave anodic stripping voltammetry (SWASV) coupled to disposable screen-printed electrodes (SPEs) was employed as a fast and sensitive electroanalytical method for the detection of heavy metals. The aim of our study was to determine Cd, Pb and Cu by SWASV in brown algae (Sargasum natan) and green turtle eggs (Chelonia mydas) using screen-printed electrodes. The method proved useful for the simultaneous analysis of these metals by comparison between two different procedures for preparing the samples. Two different approaches in digestion protocols were assessed. The study was focused on Guanahacabibes brown algae and green turtle eggs because the metal concentrations recorded in this area may be used for intraspecific comparison within the Guanahacabibes Protected Sea Park area, a body of water for which information is still very scarce. The best results were obtained by digesting biological samples with the EPA 3050B method. This treatment allowed the fast and quantitative extraction from brown algae and green turtle eggs of the target analytes, with high sensitivity and avoiding organic residues, eventually affecting electrochemical measurements.