Sebastian Schmitter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sebastian Schmitter has a total of 254 co-authors. Here are the top co-authors by number of shared publications:
- Christoph Stefan Aigner
Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
18 shared publications - Pierre-François Van de Moortele
Center for Magnetic Resonance Research (CMRR) University of Minnesota Minneapolis Minnesota USA
13 shared publications - Tobias Schaeffter
Physikalisch‐Technische Bundesanstalt Berlin Germany
12 shared publications Kâmil Uğurbil
Center for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota, Minneapolis, Minnesota
11 shared publications- Armin Michael Nagel
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Germany (A.M.N.).
10 shared publications - Edward J. Auerbach
Center for Magnetic Resonance Research (CMRR) University of Minnesota Minneapolis Minnesota USA
10 shared publications
Latest Publications
- Open Access
- 14 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2988-3001
Evaluation of 7 Tesla pTx Body Coils Regarding Transmit and Receive Performance
Purpose: Most sites develop and use custom coils for 7 T body MRI since no standard pTx body coil exists, leading to diverse coil designs differing in transmit element type, layout, and number of receive channels. This study investigates and compares eight existing coils, including one remote body coil array and seven local arrays, regarding their transmit and receive performance. Methods: Phantom measurements were conducted with all coils on the same 7 T scanner, using the same phantom and imaging protocol. Transmit performance was compared in terms of B 1 + efficiency and coverage. Receive performance was compared in terms of SNR, coverage, noise correlation, and g‐factors. Results: Mean B 1 + efficiency ranged from 2.02 to 4.33 μT/√kW across configurations, lowest for the remote array and highest for an 8Tx8Rx local array. Central SNR ranged from 278 to 1072, increasing with receive element count and peaking for an 8Tx32Rx configuration. HF‐excitation‐coverage ranged from 34 to 384 mm, and HF‐receive‐coverage from 135 to 384 mm, with the remote array combined with a local 32Rx array achieving highest coverage. Acceleration performance improved with increasing receive element count in the corresponding direction. An 8Tx16Rx and an 8Tx32Rx arrays performed best in LR‐/AP‐direction and the 32Rx array in HF‐direction. Conclusion: No existing local pTx coil provides universally optimal performance, as each design offers different advantages in either B 1 + efficiency, coverage, SNR, or acceleration. Among the local arrays, the 8Tx32Rx array (C5) might represent a reasonable compromise with respect to the parameters evaluated in this study, as it exhibits the highest central SNR, high coverage, and acceleration.
- 14 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2988-3001
Open AccessEvaluation of 7 Tesla pTx Body Coils Regarding Transmit and Receive Performance
Purpose: Most sites develop and use custom coils for 7 T body MRI since no standard pTx body coil exists, leading to diverse coil designs differing in transmit element type, layout, and number of receive channels. This study investigates and compares eight existing coils, including one remote body coil array and seven local arrays, regarding their transmit and receive performance. Methods: Phantom measurements were conducted with all coils on the same 7 T scanner, using the same phantom and imaging protocol. Transmit performance was compared in terms of B 1 + efficiency and coverage. Receive performance was compared in terms of SNR, coverage, noise correlation, and g‐factors. Results: Mean B 1 + efficiency ranged from 2.02 to 4.33 μT/√kW across configurations, lowest for the remote array and highest for an 8Tx8Rx local array. Central SNR ranged from 278 to 1072, increasing with receive element count and peaking for an 8Tx32Rx configuration. HF‐excitation‐coverage ranged from 34 to 384 mm, and HF‐receive‐coverage from 135 to 384 mm, with the remote array combined with a local 32Rx array achieving highest coverage. Acceleration performance improved with increasing receive element count in the corresponding direction. An 8Tx16Rx and an 8Tx32Rx arrays performed best in LR‐/AP‐direction and the 32Rx array in HF‐direction. Conclusion: No existing local pTx coil provides universally optimal performance, as each design offers different advantages in either B 1 + efficiency, coverage, SNR, or acceleration. Among the local arrays, the 8Tx32Rx array (C5) might represent a reasonable compromise with respect to the parameters evaluated in this study, as it exhibits the highest central SNR, high coverage, and acceleration.
- Open Access
- 5 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
A Physiologic Left Ventricle Flow Phantom for 4D Flow MRI Applications and CFD Verification
Purpose: In vivo verification for the development of cardiac MRI and CFD simulations is limited by scan time and motion artifacts. We developed a subject-specific, MRI-compatible left ventricle (LV) phantom within a closed-loop circulation system driven by an MRI-safe pump to reproduce cardiac motion and provide robust data for high-fidelity model validation. Methods: The LV was fabricated from a PVA-based hydrogel to ensure MRI contrast, mechanical stability, and reusability. The complete setup fulfills key requirements for long-term leakage-free operation, close coil placement, and resembles in vivo soft-tissue contrasts. The setup reproduces healthy end-diastolic and end-systolic geometries, including physiologic contraction and papillary muscles. Integrated aortic and mitral valves approximate physiological opening and closing. High image contrast enabled time-resolved segmentation of the LV geometry. Results: The LV shape matched the target anatomy well, despite minor deviations at the basal transition and in valve orifice, with mild aortic stenosis and mitral regurgitation. 4D flow MRI confirmed physiological flow patterns, including diastolic vortex ring formation and realistic systolic outflow. Velocity estimates confirmed the phantom’s applicability in an in vitro setting without scan time limitations. The acquired time-resolved MRI data enabled CFD simulations incorporating LV and valve motion, although segmentation accuracy remains a primary source of uncertainty. Conclusion: This LV phantom provides a stable, MRI-compatible platform for generating reproducible data to validate modeling of intracardiac hemodynamics. Its realistic anatomy, motion, and flow patterns support both simulation validation and MRI sequence development. Future work will focus on improving valve kinematics and LV motion fidelity.
- 5 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
Open AccessA Physiologic Left Ventricle Flow Phantom for 4D Flow MRI Applications and CFD Verification
Purpose: In vivo verification for the development of cardiac MRI and CFD simulations is limited by scan time and motion artifacts. We developed a subject-specific, MRI-compatible left ventricle (LV) phantom within a closed-loop circulation system driven by an MRI-safe pump to reproduce cardiac motion and provide robust data for high-fidelity model validation. Methods: The LV was fabricated from a PVA-based hydrogel to ensure MRI contrast, mechanical stability, and reusability. The complete setup fulfills key requirements for long-term leakage-free operation, close coil placement, and resembles in vivo soft-tissue contrasts. The setup reproduces healthy end-diastolic and end-systolic geometries, including physiologic contraction and papillary muscles. Integrated aortic and mitral valves approximate physiological opening and closing. High image contrast enabled time-resolved segmentation of the LV geometry. Results: The LV shape matched the target anatomy well, despite minor deviations at the basal transition and in valve orifice, with mild aortic stenosis and mitral regurgitation. 4D flow MRI confirmed physiological flow patterns, including diastolic vortex ring formation and realistic systolic outflow. Velocity estimates confirmed the phantom’s applicability in an in vitro setting without scan time limitations. The acquired time-resolved MRI data enabled CFD simulations incorporating LV and valve motion, although segmentation accuracy remains a primary source of uncertainty. Conclusion: This LV phantom provides a stable, MRI-compatible platform for generating reproducible data to validate modeling of intracardiac hemodynamics. Its realistic anatomy, motion, and flow patterns support both simulation validation and MRI sequence development. Future work will focus on improving valve kinematics and LV motion fidelity.
- Open Access
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2370-2378
Analytical Ground Truth for Phase-Contrast MRI Experiments and Simulations: Open-Source Precision-Controlled Bidirectional Rotational Phantom
We present a fully open-source, air-driven bidirectional, rotational MRI phantom. It enables an accurate and reproducible evaluation of displacement artefacts for any MRI sequence and velocity field and acceleration sensitivity for phase-contrast MRI (PC-MRI) sequences. Its unique feature of analytically defined motion is expected to narrow the gap between simulations and experiments for in-silico and in-vitro experiments using the very same sequence code. A rotational phantom was bidirectionally driven (clockwise (CW) / counterclockwise (CCW)) by an actively controlled airflow. The rotating cylinder filled with a Polyvinylpyrrolidone-water mixture was monitored via an external laser-based tachometer system. Vendor-supplied and custom open-source PC-MRI sequences were evaluated on a 3T MRI system and used as input for Bloch simulations. Resulting magnitude and velocity images were evaluated against the phantom's ground truth data. For physiological angular velocities, displacement errors resulted in a 10% radial stretch while apparent acceleration sensitivity is 5% of venc. The time difference between velocity and spatial encoding time points of 1.9ms determining the severity of the artefacts could be quantified without prior knowledge of details about the MR sequence. Simulation and experiment yielded excellent agreement. The phantom enables an easy, precise and repeatable evaluation of motion sensitivity of MR sequences and may offer a future reference measurement. Additional timing parameters of MR sequences may be reported in future literature to improve comparability. The seamless MRI sequence definition for in-silico and in-vitro experiments narrows a significant gap in MR research. This work establishes a reproducible, standardized validation framework for PC-MRI techniques that can be readily implemented across institutions, facilitating quality assurance procedures and supporting the development of more accurate flow quantification methods in clinical applications.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2370-2378
Open AccessAnalytical Ground Truth for Phase-Contrast MRI Experiments and Simulations: Open-Source Precision-Controlled Bidirectional Rotational Phantom
We present a fully open-source, air-driven bidirectional, rotational MRI phantom. It enables an accurate and reproducible evaluation of displacement artefacts for any MRI sequence and velocity field and acceleration sensitivity for phase-contrast MRI (PC-MRI) sequences. Its unique feature of analytically defined motion is expected to narrow the gap between simulations and experiments for in-silico and in-vitro experiments using the very same sequence code. A rotational phantom was bidirectionally driven (clockwise (CW) / counterclockwise (CCW)) by an actively controlled airflow. The rotating cylinder filled with a Polyvinylpyrrolidone-water mixture was monitored via an external laser-based tachometer system. Vendor-supplied and custom open-source PC-MRI sequences were evaluated on a 3T MRI system and used as input for Bloch simulations. Resulting magnitude and velocity images were evaluated against the phantom's ground truth data. For physiological angular velocities, displacement errors resulted in a 10% radial stretch while apparent acceleration sensitivity is 5% of venc. The time difference between velocity and spatial encoding time points of 1.9ms determining the severity of the artefacts could be quantified without prior knowledge of details about the MR sequence. Simulation and experiment yielded excellent agreement. The phantom enables an easy, precise and repeatable evaluation of motion sensitivity of MR sequences and may offer a future reference measurement. Additional timing parameters of MR sequences may be reported in future literature to improve comparability. The seamless MRI sequence definition for in-silico and in-vitro experiments narrows a significant gap in MR research. This work establishes a reproducible, standardized validation framework for PC-MRI techniques that can be readily implemented across institutions, facilitating quality assurance procedures and supporting the development of more accurate flow quantification methods in clinical applications.
- Open Access
- 6 April 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (5) , e70263
Cross‐Site Generalization of CNN‐Based B1+ Mapping in UHF MRI
Convolutional neural networks (CNNs) can rapidly predict channel‐wise maps from 7T localizer images, reducing acquisition time to seconds. This paper investigates if a CNN trained on one site's data can generalize to predict maps for brain imaging at unseen sites supporting the feasibility of a universal network for subject‐specific ‐ mapping. We evaluated a U‐Net CNN cross‐site generalization by training on datasets from two different 7T sites and testing its performance across three 7T sites (1 additional testing site) to assess robustness, adaptability, and generalization. The study design included both commercially same systems and the identical physical hardware unit transported between two sites, enabling a more insightful attribution of performance differences to either hardware issues or dataset‐specific variations. To assess prediction quality, we examined magnitude/phase images, error maps, correlation plots, Pearson coefficients, and residual spread plots. Quantitative evaluation included RMSE and SSIM scores. Finally, we calculated 4 kT‐points pulses with both on‐site and cross‐site CNNs to evaluate the effectiveness of the obtained maps for parallel‐transmission (pTx). While on‐site transversal magnitude RMSE scores were as low as 3.0% and 3.1% for the two CNNs, their respective transfer yielded 3.6% and 4.1%. The dynamic pTx‐application showed a CV of 6.5% when using maps predicted by a network trained on its own site. The transfer case, using a map predicted from a network trained on a different site, yielded an increased CV of 13.7%. Although cross‐site applications introduced larger deviations, the predicted maps remained qualitatively plausible and enabled practical use cases, such as calculating dynamic‐pTx. These findings support the potential of cross‐site training, suggesting CNNs trained at one site may generalize sufficiently to unseen sites without additional adjustments. This strengthens the feasibility of a transferable training approach where a single network could be deployed across different institutions without extensive retraining.
- 6 April 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (5) , e70263
Open AccessCross‐Site Generalization of CNN‐Based B1+ Mapping in UHF MRI
Convolutional neural networks (CNNs) can rapidly predict channel‐wise maps from 7T localizer images, reducing acquisition time to seconds. This paper investigates if a CNN trained on one site's data can generalize to predict maps for brain imaging at unseen sites supporting the feasibility of a universal network for subject‐specific ‐ mapping. We evaluated a U‐Net CNN cross‐site generalization by training on datasets from two different 7T sites and testing its performance across three 7T sites (1 additional testing site) to assess robustness, adaptability, and generalization. The study design included both commercially same systems and the identical physical hardware unit transported between two sites, enabling a more insightful attribution of performance differences to either hardware issues or dataset‐specific variations. To assess prediction quality, we examined magnitude/phase images, error maps, correlation plots, Pearson coefficients, and residual spread plots. Quantitative evaluation included RMSE and SSIM scores. Finally, we calculated 4 kT‐points pulses with both on‐site and cross‐site CNNs to evaluate the effectiveness of the obtained maps for parallel‐transmission (pTx). While on‐site transversal magnitude RMSE scores were as low as 3.0% and 3.1% for the two CNNs, their respective transfer yielded 3.6% and 4.1%. The dynamic pTx‐application showed a CV of 6.5% when using maps predicted by a network trained on its own site. The transfer case, using a map predicted from a network trained on a different site, yielded an increased CV of 13.7%. Although cross‐site applications introduced larger deviations, the predicted maps remained qualitatively plausible and enabled practical use cases, such as calculating dynamic‐pTx. These findings support the potential of cross‐site training, suggesting CNNs trained at one site may generalize sufficiently to unseen sites without additional adjustments. This strengthens the feasibility of a transferable training approach where a single network could be deployed across different institutions without extensive retraining.
- Open Access
- 18 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (3) , 1489-1502
Flip Angle Errors in Actual Flip Angle Imaging Using Polyvinylpyrrolidone/Water‐Based Phantoms
Purpose: The aim of this work is to report and investigate unexpected errors in actual flip angle imaging (AFI) applied to phantom fillings based on polyvinylpyrrolidone (PVP). Methods: Flip angle maps of PVP/water mixtures with different PVP ratios were acquired at 3 T and 7 T using a 3D cartesian AFI. The influence of spoiling was investigated by varying the RF‐spoiling phase increment Φ 0 for different settings of the spoiling gradient moments. The results were compared with a reference method and EPG simulations. AFI measurements with varying TE were carried out to investigate non‐spoiling‐related errors. Furthermore, 1 H‐NMR spectroscopy was performed on PVP samples. Results: Measurements reveal spoiling curves of PVP/water mixtures that lack the symmetry around Φ 0 = 90° that has been observed in prior work. Depending on the TE and PVP ratio, substantial deviations from the reference value are found, which are not observed in water samples. Varying the TE shows oscillatory behavior of the AFI signals in PVP/water mixtures that match with the existence of PVP bands found in 1 H‐NMR spectra. Including a signal component with a precession frequency that matches a PVP band into the simulations allows the reproduction of the asymmetric spoiling curves. Conclusion: Under certain conditions, AFI of PVP/water mixtures suffers from errors originating from interferences of the water and PVP signal components. This can severely reduce the accuracy of the AFI and must be considered for mapping with AFI. The impact of this effect can be reduced by increased TE as well as high PVP ratios.
- 18 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (3) , 1489-1502
Open AccessFlip Angle Errors in Actual Flip Angle Imaging Using Polyvinylpyrrolidone/Water‐Based Phantoms
Purpose: The aim of this work is to report and investigate unexpected errors in actual flip angle imaging (AFI) applied to phantom fillings based on polyvinylpyrrolidone (PVP). Methods: Flip angle maps of PVP/water mixtures with different PVP ratios were acquired at 3 T and 7 T using a 3D cartesian AFI. The influence of spoiling was investigated by varying the RF‐spoiling phase increment Φ 0 for different settings of the spoiling gradient moments. The results were compared with a reference method and EPG simulations. AFI measurements with varying TE were carried out to investigate non‐spoiling‐related errors. Furthermore, 1 H‐NMR spectroscopy was performed on PVP samples. Results: Measurements reveal spoiling curves of PVP/water mixtures that lack the symmetry around Φ 0 = 90° that has been observed in prior work. Depending on the TE and PVP ratio, substantial deviations from the reference value are found, which are not observed in water samples. Varying the TE shows oscillatory behavior of the AFI signals in PVP/water mixtures that match with the existence of PVP bands found in 1 H‐NMR spectra. Including a signal component with a precession frequency that matches a PVP band into the simulations allows the reproduction of the asymmetric spoiling curves. Conclusion: Under certain conditions, AFI of PVP/water mixtures suffers from errors originating from interferences of the water and PVP signal components. This can severely reduce the accuracy of the AFI and must be considered for mapping with AFI. The impact of this effect can be reduced by increased TE as well as high PVP ratios.
- Open Access
- 4 October 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 1140-1154
Quantitative Confounder Analysis of Electrocardiogram Signals in Cardiac Magnetic Resonance at 1.5, 3 and 7 T—Assessing Standardized Electrode Positions and Sequence Types—Towards Quality Assurance
Background: The electrocardiogram (ECG) used for gating in cardiac MRI may be compromised by multiple confounders inside the scanner bore. Purpose: To quantify the influence of magnetic field strengths (1.5 T/3 T/7 T), standardized electrode positions, and imaging sequences on ECG signals used for gating. Study Type: Prospective. Population: Sixteen healthy volunteers (eight male; mean age 26.25 ± 7.67 years). Field Strength/Sequence: Balanced steady‐state free precession cine (1.5 T/3 T), fast low‐angle shot cine (7 T), and 4D flow (1.5 T/3 T/7 T) sequences. Assessment: ECG‐signals were recorded during breath‐hold and non‐breath‐hold short axis cine (sax‐bh and sax‐nbh, respectively) and 4D flow scans at 1.5 T/3 T/7 T. All scans were repeated with 4 standardized electrode positionings (pos1–4) at each field strength. Pos1/2 were vendor‐recommended positionings for 1.5 T/3 T/7 T scans, respectively, whereas pos3/4 were alternative positionings recommended in previous studies. Similarity between confounded ECG‐signals and unconfounded baseline ECG‐signals was assessed by QRS‐feature correlation. Cine image quality (IQ) was assessed by 3 readers (with 6, 10, and 22 years experience) on a four‐point Likert scale. Statistical Tests: Linear mixed models with type III tests of fixed effects (overall) and t tests with adjusted degrees of freedom (pairwise subgroup‐comparisons) at significance level p < 0.05. Results: Increasing field strength resulted in significantly decreasing similarity to baseline measurements, with r values (provided with 95% confidence interval) of 1.5 T: 97% (92.6–101.3); 3 T: 91.4% (87.1–95.8); 7 T: 50.4% (46–54.9) and lower IQ: 1.5 T: 2.33 (2.12–2.55); 3 T: 1.96 (1.75–2.17); 7 T: 0.91 (0.7–1.12). Vendor‐specified electrode positions pos1: 91.8% (87.2–96.5), pos2: 88.3% (83.7–92.9) showed significantly higher correlation with baseline measurements than alternative positions pos3: 67.5% (62.9–72.1) and pos4: 70.8% (66.2–75.4). The evaluated standardized sequences showed similar amounts of electrocardiogram distortion, with r values of: sax‐bh: 77.3% (73–81.7); 4D: 79.3% (75–83.7), p = 0.54; sax‐nbh: 82.1% (77.8–86.5), p = 0.31, but the difference between sax‐bh and sax‐nbh: 4.8% (2.88–6.72) was significant. Data Conclusion: Increasing field strength leads to significant ECG signal distortions. Vendor‐specified positions 1/2 resulted in less distorted ECG signals than alternative positions 3/4 recommended in previous publications. Level of Evidence: 2. Technical Efficacy: Stage 5.
- 4 October 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 1140-1154
Open AccessQuantitative Confounder Analysis of Electrocardiogram Signals in Cardiac Magnetic Resonance at 1.5, 3 and 7 T—Assessing Standardized Electrode Positions and Sequence Types—Towards Quality Assurance
Background: The electrocardiogram (ECG) used for gating in cardiac MRI may be compromised by multiple confounders inside the scanner bore. Purpose: To quantify the influence of magnetic field strengths (1.5 T/3 T/7 T), standardized electrode positions, and imaging sequences on ECG signals used for gating. Study Type: Prospective. Population: Sixteen healthy volunteers (eight male; mean age 26.25 ± 7.67 years). Field Strength/Sequence: Balanced steady‐state free precession cine (1.5 T/3 T), fast low‐angle shot cine (7 T), and 4D flow (1.5 T/3 T/7 T) sequences. Assessment: ECG‐signals were recorded during breath‐hold and non‐breath‐hold short axis cine (sax‐bh and sax‐nbh, respectively) and 4D flow scans at 1.5 T/3 T/7 T. All scans were repeated with 4 standardized electrode positionings (pos1–4) at each field strength. Pos1/2 were vendor‐recommended positionings for 1.5 T/3 T/7 T scans, respectively, whereas pos3/4 were alternative positionings recommended in previous studies. Similarity between confounded ECG‐signals and unconfounded baseline ECG‐signals was assessed by QRS‐feature correlation. Cine image quality (IQ) was assessed by 3 readers (with 6, 10, and 22 years experience) on a four‐point Likert scale. Statistical Tests: Linear mixed models with type III tests of fixed effects (overall) and t tests with adjusted degrees of freedom (pairwise subgroup‐comparisons) at significance level p < 0.05. Results: Increasing field strength resulted in significantly decreasing similarity to baseline measurements, with r values (provided with 95% confidence interval) of 1.5 T: 97% (92.6–101.3); 3 T: 91.4% (87.1–95.8); 7 T: 50.4% (46–54.9) and lower IQ: 1.5 T: 2.33 (2.12–2.55); 3 T: 1.96 (1.75–2.17); 7 T: 0.91 (0.7–1.12). Vendor‐specified electrode positions pos1: 91.8% (87.2–96.5), pos2: 88.3% (83.7–92.9) showed significantly higher correlation with baseline measurements than alternative positions pos3: 67.5% (62.9–72.1) and pos4: 70.8% (66.2–75.4). The evaluated standardized sequences showed similar amounts of electrocardiogram distortion, with r values of: sax‐bh: 77.3% (73–81.7); 4D: 79.3% (75–83.7), p = 0.54; sax‐nbh: 82.1% (77.8–86.5), p = 0.31, but the difference between sax‐bh and sax‐nbh: 4.8% (2.88–6.72) was significant. Data Conclusion: Increasing field strength leads to significant ECG signal distortions. Vendor‐specified positions 1/2 resulted in less distorted ECG signals than alternative positions 3/4 recommended in previous publications. Level of Evidence: 2. Technical Efficacy: Stage 5.
- Open Access
- 29 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 1157-1168
Evaluation of an interleaved acquisition scheme for improved robustness of channel‐wise relative B 1 + mapping at 7 T
Purpose: The purpose was to evaluate, whether an interleaved acquisition scheme for a fast relative mapping method at 7 T reduces the likelihood of errors from exceeding the linear flip angle (FA) regime compared to a conventional sequential acquisition. Methods: Simulations of a channel‐wise relative mapping sequence were performed for sequential and interleaved acquisition schemes at different reference voltages (≙ different FAs). The simulations were performed for a phantom, the heart and the prostate and were based on 7 T ground‐truth (GT) data acquired with an actual FA imaging sequence (phantom) or obtained from electromagnetic field simulations (heart/prostate). Acquisition schemes were evaluated based on their signal linearity by calculating a normalized mean FA error between simulated signal intensities and GT data. Additionally, validation measurements of relative maps with the sequential and interleaved acquisition schemes were acquired for the phantom. Results: Validation measurements showed a good agreement with the simulation results for both acquisition schemes and displayed stronger deviations to the GT data for the sequential scheme. The quantitative evaluation yielded higher FA errors for the sequential acquisition scheme for all three regions and all simulated reference voltages. At the same level of error, mean signals were higher for the interleaved acquisition scheme in all cases. Differences between interleaved and sequential acquisition schemes were most pronounced in the steady‐state. Conclusion: An interleaved acquisition of channel‐wise relative maps extends the range of the linear FA regime, reducing the likelihood of errors and increasing the robustness of the approach.
- 29 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 1157-1168
Open AccessEvaluation of an interleaved acquisition scheme for improved robustness of channel‐wise relative B 1 + mapping at 7 T
Purpose: The purpose was to evaluate, whether an interleaved acquisition scheme for a fast relative mapping method at 7 T reduces the likelihood of errors from exceeding the linear flip angle (FA) regime compared to a conventional sequential acquisition. Methods: Simulations of a channel‐wise relative mapping sequence were performed for sequential and interleaved acquisition schemes at different reference voltages (≙ different FAs). The simulations were performed for a phantom, the heart and the prostate and were based on 7 T ground‐truth (GT) data acquired with an actual FA imaging sequence (phantom) or obtained from electromagnetic field simulations (heart/prostate). Acquisition schemes were evaluated based on their signal linearity by calculating a normalized mean FA error between simulated signal intensities and GT data. Additionally, validation measurements of relative maps with the sequential and interleaved acquisition schemes were acquired for the phantom. Results: Validation measurements showed a good agreement with the simulation results for both acquisition schemes and displayed stronger deviations to the GT data for the sequential scheme. The quantitative evaluation yielded higher FA errors for the sequential acquisition scheme for all three regions and all simulated reference voltages. At the same level of error, mean signals were higher for the interleaved acquisition scheme in all cases. Differences between interleaved and sequential acquisition schemes were most pronounced in the steady‐state. Conclusion: An interleaved acquisition of channel‐wise relative maps extends the range of the linear FA regime, reducing the likelihood of errors and increasing the robustness of the approach.
- Open Access
- 22 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1930-1945
Quantitative abdominal sodium MRI combined with 32‐channel proton pTx MRI at 7 Tesla in a large field‐of‐view
Purpose: To combine large field‐of‐view abdominal and quantitative sodium () MRI in the same position at 7 T to enable the quantification of the tissue sodium concentration via MRI and the anatomical assignment in images without repositioning in several tissues and organs at once.Methods: A custom‐built birdcage coil and reference vial setup together with a 32‐channel pTx array were employed at 7 T to allow dual‐nuclei MRI in the same position for a field‐of‐view (FOV) of . relaxation effects in the reference vials and phantom were corrected, maps were measured, and maps were simulated to correct the acquired data in post‐processing. These corrections were evaluated in a phantom and then applied in vivo in three healthy volunteers.Results: In the phantom, it was demonstrated that proton and quantitative sodium MR images share the same large FOV. Phantom measurements showed an improved sodium concentration accuracy after the performed corrections. Large FOV and quantitative in vivo MRI was demonstrated in three healthy volunteers.Conclusion: This work shows the feasibility of combined and quantitative imaging at 7 T in a large FOV both under free breathing in , laying the ground work for an accurate evaluation of the tissue sodium concentration in several organs at once.
- 22 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1930-1945
Open AccessQuantitative abdominal sodium MRI combined with 32‐channel proton pTx MRI at 7 Tesla in a large field‐of‐view
Purpose: To combine large field‐of‐view abdominal and quantitative sodium () MRI in the same position at 7 T to enable the quantification of the tissue sodium concentration via MRI and the anatomical assignment in images without repositioning in several tissues and organs at once.Methods: A custom‐built birdcage coil and reference vial setup together with a 32‐channel pTx array were employed at 7 T to allow dual‐nuclei MRI in the same position for a field‐of‐view (FOV) of . relaxation effects in the reference vials and phantom were corrected, maps were measured, and maps were simulated to correct the acquired data in post‐processing. These corrections were evaluated in a phantom and then applied in vivo in three healthy volunteers.Results: In the phantom, it was demonstrated that proton and quantitative sodium MR images share the same large FOV. Phantom measurements showed an improved sodium concentration accuracy after the performed corrections. Large FOV and quantitative in vivo MRI was demonstrated in three healthy volunteers.Conclusion: This work shows the feasibility of combined and quantitative imaging at 7 T in a large FOV both under free breathing in , laying the ground work for an accurate evaluation of the tissue sodium concentration in several organs at once.
- Open Access
- 18 June 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (8) , e70080
Accurate MRF‐Based 3D Multi‐Channel B1+ Mapping in the Human Body at 7 T
This work proposes a 3D multi‐transmit channel B1+ mapping approach based on magnetic resonance fingerprinting (MRF) for the human abdomen at 7 T. A stack‐of‐stars acquisition is employed to achieve motion‐robust 3D encoding, along with a hybrid method where transmit (Tx) channel‐wise B1+ information is obtained through low flip angle GRE images. B1+ mapping at ultra‐high field (UHF) in the human abdomen is particularly challenging due to the large dynamic range of B1+, the extensive field of view (FOV), and the effects of respiratory motion. Few methods have been proposed to address these challenges, with a significant limitation being the relatively low RF power available at UHF, especially for pTx systems with a 8 × 1 kW power configuration. This limitation makes it difficult to achieve FAs greater than 30° in central body regions, which are required for accurate results with classical methods. In contrast, Tx channel‐combined MRF‐based B1+ mapping has been validated as accurate for FAs greater than 6°, offering improved accuracy at low FAs. Here, two Tx channel‐combined MRF‐based B1+ maps (B1‐MRF) are acquired using two tailored complementary phase shims to obtain absolute B1+ information across the entire FOV. The 3D hybrid approach was validated against a 2D reference using phantoms and in vivo free‐breathing scans in three subjects with varying BMIs, where only one Tx channel was active at a time. The comparison showed strong agreement, with the 3D hybrid acquisition demonstrating improved performance in regions affected by flow, low FAs, or low signal‐to‐noise ratio compared to the 2D implementation. The higher accuracy and level of detail provided by the proposed method, in contrast to existing methods, are particularly relevant for several applications, including the validation of faster approaches, validation of electromagnetic simulations (which are safety‐critical), and the creation of B1+ map libraries for applications such as AI‐based B1+ mapping or universal pulse calculations.
- 18 June 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (8) , e70080
Open AccessAccurate MRF‐Based 3D Multi‐Channel B1+ Mapping in the Human Body at 7 T
This work proposes a 3D multi‐transmit channel B1+ mapping approach based on magnetic resonance fingerprinting (MRF) for the human abdomen at 7 T. A stack‐of‐stars acquisition is employed to achieve motion‐robust 3D encoding, along with a hybrid method where transmit (Tx) channel‐wise B1+ information is obtained through low flip angle GRE images. B1+ mapping at ultra‐high field (UHF) in the human abdomen is particularly challenging due to the large dynamic range of B1+, the extensive field of view (FOV), and the effects of respiratory motion. Few methods have been proposed to address these challenges, with a significant limitation being the relatively low RF power available at UHF, especially for pTx systems with a 8 × 1 kW power configuration. This limitation makes it difficult to achieve FAs greater than 30° in central body regions, which are required for accurate results with classical methods. In contrast, Tx channel‐combined MRF‐based B1+ mapping has been validated as accurate for FAs greater than 6°, offering improved accuracy at low FAs. Here, two Tx channel‐combined MRF‐based B1+ maps (B1‐MRF) are acquired using two tailored complementary phase shims to obtain absolute B1+ information across the entire FOV. The 3D hybrid approach was validated against a 2D reference using phantoms and in vivo free‐breathing scans in three subjects with varying BMIs, where only one Tx channel was active at a time. The comparison showed strong agreement, with the 3D hybrid acquisition demonstrating improved performance in regions affected by flow, low FAs, or low signal‐to‐noise ratio compared to the 2D implementation. The higher accuracy and level of detail provided by the proposed method, in contrast to existing methods, are particularly relevant for several applications, including the validation of faster approaches, validation of electromagnetic simulations (which are safety‐critical), and the creation of B1+ map libraries for applications such as AI‐based B1+ mapping or universal pulse calculations.
- Open Access
- 24 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1604-1615
Human liver CEST imaging at 7 T: Impact of B1+ shimming
Purpose: To explore the feasibility of CEST imaging in the human liver at 7 T with shimming. Methods: CEST MRI was performed on a 7 T whole‐body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx ( shimming) was applied to locally maximize the magnitude per input power within a given region of interest (ROI) of approximately 30 mm diameter (ROI shim ). Relaxation‐compensated inverse magnetization transfer ratio (MTR Rex ) values were quantified for amide protons, guanidino protons, and relayed nuclear Overhauser effect signals based on five‐pool Lorentzian fit analysis. MTR Rex values were corrected for B 1 inhomogeneities using an absolute, accurate MR fingerprinting–based mapping technique. Results: Within the ROI shim , reliable MTR Rex values could be calculated for an average of 85% of voxels. The mean MTR Rex values and corresponding coefficient of variations across the group are: 0.113 ± 0.009, 8.8% for amide; 0.167 ± 0.010, 6.3% for nuclear Overhauser effect; and 0.079 ± 0.010, 12.9% for guanidino. MTR Rex values exhibit low variation between subjects, as reflected by low coefficient of variations. Conclusion: In this study, we have demonstrated for the first time the feasibility of acquiring and quantifying relaxation‐compensated CEST contrasts in the human liver at ultrahigh field. The application of static pTx effectively eliminates dropouts and allows for accurate CEST contrast quantification within the selected ROI. In addition, the proposed mapping technique shows efficacy for enhanced MTR Rex B 1 corrections in the abdomen.
- 24 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1604-1615
Open AccessHuman liver CEST imaging at 7 T: Impact of B1+ shimming
Purpose: To explore the feasibility of CEST imaging in the human liver at 7 T with shimming. Methods: CEST MRI was performed on a 7 T whole‐body scanner with a parallel transmission (pTx) system in five healthy volunteers. Static pTx ( shimming) was applied to locally maximize the magnitude per input power within a given region of interest (ROI) of approximately 30 mm diameter (ROI shim ). Relaxation‐compensated inverse magnetization transfer ratio (MTR Rex ) values were quantified for amide protons, guanidino protons, and relayed nuclear Overhauser effect signals based on five‐pool Lorentzian fit analysis. MTR Rex values were corrected for B 1 inhomogeneities using an absolute, accurate MR fingerprinting–based mapping technique. Results: Within the ROI shim , reliable MTR Rex values could be calculated for an average of 85% of voxels. The mean MTR Rex values and corresponding coefficient of variations across the group are: 0.113 ± 0.009, 8.8% for amide; 0.167 ± 0.010, 6.3% for nuclear Overhauser effect; and 0.079 ± 0.010, 12.9% for guanidino. MTR Rex values exhibit low variation between subjects, as reflected by low coefficient of variations. Conclusion: In this study, we have demonstrated for the first time the feasibility of acquiring and quantifying relaxation‐compensated CEST contrasts in the human liver at ultrahigh field. The application of static pTx effectively eliminates dropouts and allows for accurate CEST contrast quantification within the selected ROI. In addition, the proposed mapping technique shows efficacy for enhanced MTR Rex B 1 corrections in the abdomen.