Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jann Lennard Scharf has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Michael Gembicki

    Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University of Luebeck, University Hospital Schleswig-Holstein, Luebeck, Germany

    10 shared publications
  • Jan Weichert

    University Hospital of Schleswig-Holstein

    9 shared publications
  • Amrei Welp

    Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University of Luebeck, University Hospital Schleswig-Holstein, Luebeck, Germany

    7 shared publications
  • Christoph Dracopoulos

    Department of Gynecology and Obstetrics Division of Prenatal Medicine University Hospital of Schleswig‐Holstein Lübeck Germany

    7 shared publications
  • Jan Weichert

    Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University of Luebeck, University Hospital Schleswig-Holstein, Luebeck, Germany

    7 shared publications
  • Achim Rody

    Department of Gynecology and Obstetrics, Division of Prenatal Medicine , University Hospital of Schleswig-Holstein , Lübeck , Germany

    6 shared publications

Latest Publications

  • Open Access

    Life-threatening fetal goiter: diagnosis and outcomes in four consecutive cases with critical appraisal—why this diagnosis is not obviously trivial

    by Jann Lennard Scharf, Michael Gembicki, Amrei Welp, Guido Stichtenoth, Verena Sailer, Jan Weichert

    Background: The diagnosis of a fetal goiter constitutes a potentially life-threatening in utero condition for the fetus. Even with early diagnosis and close therapy with highly specialized interdisciplinary management, the prognosis remains poor. We discuss diagnostic and therapeutic challenges regarding the pre- and postnatal outcome based on four consecutive cases with a critical appraisal of latest heterogeneous recommendations in literature. Methods: A retrospective review of four cases of fetal goiter is presented that were diagnosed at a tertiary university centre during targeted ultrasound (US) examination in second and third trimester. All cases underwent close and intensive pre- and postnatal diagnostics and treatment. A detailed workup of current diagnostic and therapeutic recommendations with identifying potential pitfalls was carried out. Case series: In one case, the mother suffered from Graves’ disease with euthyroid blood parameters under medication. The other three gravidae largely had an uneventful medical history including euthyroid metabolism. In all cases, fetal hypothyroidism was suspected and in three of them, cordocentesis was performed and intraamniotic levothyroxine (LT4) was given. In none of the cases, sonographic signs of tracheoesophageal compression had been noticed. In all four cases, a planned cesarean section was performed between 32 and 39 weeks of gestation (weeks). Out of all four cases, only one fetus managed to survive: one fetus died antenatally at 35 weeks, one newborn died due to insufficient ventilation, and one due to fetal cardiac decompensation with bilateral hydrothorax with suspected ductal obstruction. The fetus who survived showed primary hypothyroidism. Two of the deceased fetuses underwent autopsy, one showed ectopic thyroid tissue in the trachea. Conclusion: Prenatal diagnosis of congenital fetal goiter remains a serious condition in specialized centers. In practice, the following crucial considerations might impede proper application of the non-standardized recommendations suggested in available literature. In addition to the assessment of the underlying etiology, the evaluation of fetal cervical structures with determination of fetal tracheoesophageal patency and cardiac functional diagnostics requires adequate practical expertise. Interdisciplinary cooperation is mandatory when determining the time and mode of delivery and planning an ex utero intrapartum treatment (EXIT) strategy.


  • Open Access

    Advantages of fully automated AI-enhanced algorithm (5D CNS+™) for generating a fetal neurosonogram in clinical routine

    by Jann Lennard Scharf, Michael Gembicki, Achim Rody, Amrei Welp, Jan Weichert

    Objectives: The objective was to demonstrate superiority of a fully vs. semi-automated approach (5D CNS+™) and to verify operators could handle and benefit from a fully automated rendering volumetric datasets to generate a complete fetal neurosonogram. Methods: A total of 136 stored three-dimensional (3D) volumes of the brain of unselected, structurally normal fetuses were examined. Two operators applied both software versions for detailed assessment of the fetal central nervous system (CNS). The procession time was measured for each operator and for both program versions. The number of correctly calibrated planes were evaluated and necessity for manual adjustment of the planes was registered. Results: The intraclass correlation coefficient was 0.507 (0.307–0.648) for semi-automated and 0.782 (0.693–0.846) for fully automated 5D CNS+™. The acquisition time of application for semi-automated 5D CNS+™ was 27.70 s ± 6.28 s for operator 1 and 33.20 s ± 9.67 s for operator 2, for fully automated 5D CNS+™ 10.89 s ± 0.85 s for operator 1 and 10.79 s ± 0.60 s for operator 2 (p<0.0001). The statistical analysis for manually corrected planes by both operators between both software algorithms showed a Bland-Altman-Bias of 1.44/9 planes for operator 1 and 1.45/9 planes for operator 2. Conclusions: The fully automated 5D CNS+™ algorithm applied on 3D volume datasets provides examiners regardless their expertise not only enormous time efficiency, but also diagnostic confidence in evaluating details of the fetal CNS. This tremendously simplifies application in clinical routine.


  • Open Access

    Advancements in Artificial Intelligence for Fetal Neurosonography: A Comprehensive Review

    by Jan Weichert, Jann Lennard Scharf

    The detailed sonographic assessment of the fetal neuroanatomy plays a crucial role in prenatal diagnosis, providing valuable insights into timely, well-coordinated fetal brain development and detecting even subtle anomalies that may impact neurodevelopmental outcomes. With recent advancements in artificial intelligence (AI) in general and medical imaging in particular, there has been growing interest in leveraging AI techniques to enhance the accuracy, efficiency, and clinical utility of fetal neurosonography. The paramount objective of this focusing review is to discuss the latest developments in AI applications in this field, focusing on image analysis, the automation of measurements, prediction models of neurodevelopmental outcomes, visualization techniques, and their integration into clinical routine.


  • Open Access

    Advancements in Artificial Intelligence for Fetal Neurosonography: A Comprehensive Review

    by Jan Weichert, Jann Lennard Scharf

    Detailed sonographic assessment of the fetal neuroanatomy plays a crucial role in prenatal diagnosis, providing valuable insights into timely well-coordinated fetal brain development and detecting even subtle anomalies that may impact neurodevelopmental outcomes. With recent advancements in artificial intelligence (AI) in general and medical imaging in particular, there has been growing interest in leveraging AI techniques to enhance the accuracy, efficiency, and clinical utility of fetal neurosonography. The paramount objective of this scoping review is to discuss the latest developments in AI applications in this field, focusing on image analysis, automation of measurements, prediction models for neurodevelopmental outcomes, visualization techniques, and integration into clinical routine.


  • Open Access

    How automated techniques ease functional assessment of the fetal heart: Applicability of two‐dimensional speckle‐tracking echocardiography for comprehensive analysis of global and segmental cardiac deformation using fetalHQ®

    by Jann Lennard Scharf, Christoph Dracopoulos, Michael Gembicki, Achim Rody, Amrei Welp, Jan Weichert

    Background: Prenatal echocardiographic assessment of fetal cardiac function has become increasingly important. Fetal two‐dimensional speckle‐tracking echocardiography (2D‐STE) allows the determination of global and segmental functional cardiac parameters. Prenatal diagnostics is relying increasingly on artificial intelligence, whose algorithms transform the way clinicians use ultrasound in their daily workflow. The purpose of this study was to demonstrate the feasibility of whether less experienced operators can handle and might benefit from an automated tool of 2D‐STE in the clinical routine.Methods: A total of 136 unselected, normal, singleton, second‐ and third‐trimester fetuses with normofrequent heart rates were examined by targeted ultrasound. 2D‐STE was performed separately by beginner and expert semiautomatically using a GE Voluson E10 (FetalHQ®, GE Healthcare, Chicago, IL). Several fetal cardiac parameters were calculated (end‐diastolic diameter [ED], sphericity index [SI], global longitudinal strain [EndoGLS], fractional shortening [FS]) and assigned to gestational age (GA). Bland‐Altman plots were used to test agreement between both operators.Results: The mean maternal age was 33 years, and the mean maternal body mass index prior to pregnancy was 24.78 kg/m2. The GA ranged from 16.4 to 32.0 weeks (average 22.9 weeks). Averaged endoGLS value of the beginner was ‐18.57% ± 6.59 percentage points (pp) for the right and ‐19.58% ± 5.63 pp for the left ventricle, that of the expert ‐14.33% ± 4.88 pp and ‐16.37% ± 5.42 pp. With increasing GA, right ventricular endoGLS decreased slightly while the left ventricular was almost constant. The statistical analysis for endoGLS showed a Bland‐Altman‐Bias of ‐4.24 pp ± 8.06 pp for the right and ‐3.21 pp ± 7.11 pp for the left ventricle. The Bland‐Altman‐Bias of the ED in both ventricles in all analyzed segments ranged from ‐.49 mm ± 1.54 mm to ‐.10 mm ± 1.28 mm, that for FS from ‐.33 pp ± 11.82 pp to 3.91 pp ± 15.56 pp and that for SI from ‐.38 ± .68 to ‐.15 ± .45.Conclusions: Between both operators, our data indicated that 2D‐STE analysis showed excellent agreement for cardiac morphometry parameters (ED and SI), and good agreement for cardiac function parameters (EndoGLS and FS). Due to its complexity, the application of fetal 2D‐STE remains the domain of scientific‐academic perinatal ultrasound and should be placed preferably in the hands of skilled operators. At present, from our perspective, an implementation into clinical practice “on‐the‐fly” cannot be recommended.


  • Open Access

    How automated techniques ease functional assessment of the fetal heart: applicability of two-dimensional speckle-tracking echocardiography for comprehensive analysis of global and segmental cardiac deformation using fetalHQ®

    by Jann Lennard Scharf, Christoph Dracopoulos, Michael Gembicki, Achim Rody, Amrei Welp, Jan Weichert

    Background Prenatal echocardiographic assessment of fetal cardiac function has become increasingly important. Fetal two-dimensional speckle-tracking echocardiography (2D-STE) allows the determination of global and segmental functional cardiac parameters. Prenatal diagnostics is relying increasingly on artificial intelligence, whose algorithms transform the way clinicians use ultrasound in their daily workflow. The purpose of this study was to demonstrate the feasibility of whether less experienced operators can handle and might benefit from an automated tool of 2D-STE in the clinical routine. Methods A total of 136 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by targeted ultrasound. 2D-STE was performed separately by beginner and expert semiautomatically using a GE Voluson E10 (FetalHQ®, GE Healthcare, Chicago, IL, USA). Several fetal cardiac parameters were calculated (end-diastolic diameter (ED), sphericity index (SI), global longitudinal strain (EndoGLS), fractional shortening (FS)) and assigned to gestational age (GA). Bland-Altman plots were used to test agreement between both operators. Results The mean maternal age was 33 years, and the mean maternal body mass index prior to pregnancy was 24.78 kg/m 2 . The GA ranged from 16.4 to 32.0 weeks (average 22.9 weeks). Averaged endoGLS value of the beginner was -18.57 % ± 6.59 percentage points (pp) for the right and -19.58 % ± 5.63 pp for the left ventricle, that of the expert -14.33 % ± 4.88 pp and -16.37 % ± 5.42 pp. With increasing GA, right ventricular endoGLS decreased slightly while the left ventricular were almost constant. The statistical analysis for endoGLS showed a Bland-Altman-Bias of -4.24 pp ± 8.06 pp for the right and -3.21 pp ± 7.11 pp for the left ventricle. The Bland-Altman-Bias of the ED in both ventricles in all analyzed segments ranged from -0.49 mm ± 1.54 mm to -0.10 mm ± 1.28 mm, that for FS from -0.33 pp ± 11.82 pp to 3.91 pp ± 15.56 pp and that for SI from -0.38 ± 0.68 to -0.15 ± 0.45. Conclusions Between both operators, our data indicated that 2D-STE analysis showed excellent agreement for cardiac morphometry parameters (ED and SI), and good agreement for cardiac function parameters (EndoGLS and FS). Due to its complexity, the application of fetal 2D-STE remains the domain of scientific-academic perinatal ultrasound and should be placed preferably in the hands of skilled operators. At present, from our perspective, an implementation into clinical practice ‘on-the-fly’ cannot be recommended.

  • Open Access

    A Clinical Approach to Semiautomated Three-Dimensional Fetal Brain Biometry—Comparing the Strengths and Weaknesses of Two Diagnostic Tools: 5DCNS+TM and SonoCNSTM

    by Michael Gembicki, Amrei Welp, Jann Lennard Scharf, Christoph Dracopoulos, Jan Weichert

    (1) Objective: We aimed to evaluate the accuracy and efficacy of AI-assisted biometric measurements of the fetal central nervous system (CNS) by comparing two semiautomatic postprocessing tools. We further aimed to discuss the additional value of semiautomatically generated sagittal and coronal planes of the CNS. (2) Methods: Three-dimensional (3D) volumes were analyzed with two semiautomatic software tools, 5DCNS+™ and SonoCNS™. The application of 5DCNS+™ results in nine planes (axial, coronal and sagittal) displayed in a single template; SonoCNS™ depicts three axial cutting sections. The tools were compared regarding automatic biometric measurement accuracy. (3) Results: A total of 129 fetuses were included for final analysis. Our data indicate that, in terms of the biometric quantification of head circumference (HC), biparietal diameter (BPD), transcerebellar diameter (TCD) and cisterna magna (CM), the accuracy of SonoCNS™ was higher with respect to the manual measurement of an experienced examiner compared to 5DCNS+™, whereas it was the other way around regarding the diameter of the posterior horn of the lateral ventricle (Vp). The inclusion of four orthogonal coronal views in 5DCNS+™ gives valuable information regarding spatial arrangements, particularly of midline structures. (4) Conclusions: Both tools were able to ease assessment of the intracranial anatomy, highlighting the additional value of automated algorithms in clinical use. SonoCNS™ showed a superior accuracy of plane reconstruction and biometry, but volume reconstruction using 5DCNS+™ provided more detailed information, which is needed for an entire neurosonogram as suggested by international guidelines.


  • Open Access

    How Automated Techniques Ease Functional Assessment of the Fetal Heart: Applicability of MPI+™ for Direct Quantification of the Modified Myocardial Performance Index

    by Jann Lennard Scharf, Christoph Dracopoulos, Michael Gembicki, Amrei Welp, Jan Weichert

    (1) Objectives: In utero functional cardiac assessments using echocardiography have become increasingly important. The myocardial performance index (MPI, Tei index) is currently used to evaluate fetal cardiac anatomy, hemodynamics and function. An ultrasound examination is highly examiner-dependent, and training is of enormous significance in terms of proper application and subsequent interpretation. Future experts will progressively be guided by applications of artificial intelligence, on whose algorithms prenatal diagnostics will rely on increasingly. The objective of this study was to demonstrate the feasibility of whether less experienced operators might benefit from an automated tool of MPI quantification in the clinical routine. (2) Methods: In this study, a total of 85 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by a targeted ultrasound. The modified right ventricular MPI (RV-Mod-MPI) was measured, both by a beginner and an expert. A calculation was performed semiautomatically using a Samsung Hera W10 ultrasound system (MPI+™, Samsung Healthcare, Gangwon-do, South Korea) by taking separate recordings of the right ventricle’s in- and outflow using a conventional pulsed-wave Doppler. The measured RV-Mod-MPI values were assigned to gestational age. The data were compared between the beginner and the expert using a Bland-Altman plot to test the agreement between both operators, and the intraclass correlation was calculated. (3) Results: The mean maternal age was 32 years (19 to 42 years), and the mean maternal pre-pregnancy body mass index was 24.85 kg/m2 (ranging from 17.11 to 44.08 kg/m2). The mean gestational age was 24.44 weeks (ranging from 19.29 to 36.43 weeks). The averaged RV-Mod-MPI value of the beginner was 0.513 ± 0.09, and that of the expert was 0.501 ± 0.08. Between the beginner and the expert, the measured RV-Mod-MPI values indicated a similar distribution. The statistical analysis showed a Bland-Altman bias of 0.01136 (95% limits of agreement from −0.1674 to 0.1902). The intraclass correlation coefficient was 0.624 (95% confidence interval from 0.423 to 0.755). (4) Conclusions: For experts as well as for beginners, the RV-Mod-MPI is an excellent diagnostic tool for the assessment of fetal cardiac function. It is a time-saving procedure, offers an intuitive user interface and is easy to learn. There is no additional effort required to measure the RV-Mod-MPI. In times of reduced resources, such assisted systems of fast value acquisition represent clear added value. The establishment of the automated measurement of the RV-Mod-MPI in clinical routine should be the next level in cardiac function assessment.


  • Aktuelle Aspekte zur künstlichen Intelligenz in der gynäkologischen Diagnostik

    by Jann Lennard Scharf, Christoph Dracopoulos, Michael Gembicki, Amrei Welp, Jan Weichert