Cees Bruggink
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cees Bruggink has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Manfred Wuhrer
Center for Proteomics and Metabolomics, Leiden University Medical Center, Leiden, The Netherlands
6 shared publications - Sebastiaan Eeltink
Department of Chemical Engineering Vrije Universiteit Brussel (VUB) Brussels Belgium
5 shared publications J. van der Greef
Division of Analytical Chemistry, Leiden/Amsterdam Center for Drug Research, P.O. Box, 2300 RA Leiden, The Netherlands
4 shared publicationsYury Agroskin
Thermo Fisher Scientific, Sunnyvale CA, USA
4 shared publicationsAndré M. Deelder
Biomolecular Mass Spectrometry Unit, Department of Parasitology, Leiden University Medical Center, Leiden, The Netherlands
3 shared publicationsBert Wouters
Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium
3 shared publications
Latest Publications
- 1 February 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1484, 26-33
Microfluidic membrane suppressor module design and evaluation for capillary ion chromatography
- 1 February 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1484, 26-33
Microfluidic membrane suppressor module design and evaluation for capillary ion chromatography
- Open Access
- 1 October 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1033-1034, 342-352
Applying mini-bore HPAEC-MS/MS for the characterization and quantification of Fc N -glycans from heterogeneously glycosylated IgGs
- 1 October 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1033-1034, 342-352
Open AccessApplying mini-bore HPAEC-MS/MS for the characterization and quantification of Fc N -glycans from heterogeneously glycosylated IgGs
- 5 August 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (5) , 739-747
Novel Determination of Organic Acids in Diesel and Motor Oil by Ion Chromatography
A robust analytical method is required for the determination of low-molecular weight organic acids, which are potential causes of refinery and internal combustion engine corrosion. The ion chromatographic method developed in this study allows the determination of acetic acid and formic acid in diesel oil mixtures with a motor oil volume fraction of up to 10%. The hydrophobic matrix is automatically removed in-line through a matrix elution step with organic solvent and nonaqueous anion-exchange analyte extraction. Acetic acid and formic acid, as the smallest and most acidic aliphatic naphthenic acids, were determined. Gradient anion-exchange chromatography on high-capacity columns in combination with suppressed conductivity detection allowed their selective and sensitive determination. Typical recovery values were from 82 to 107% for each acid in the matrices evaluated with reproducibility less than 5% for acid fortified samples.
- 5 August 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (5) , 739-747
Novel Determination of Organic Acids in Diesel and Motor Oil by Ion Chromatography
A robust analytical method is required for the determination of low-molecular weight organic acids, which are potential causes of refinery and internal combustion engine corrosion. The ion chromatographic method developed in this study allows the determination of acetic acid and formic acid in diesel oil mixtures with a motor oil volume fraction of up to 10%. The hydrophobic matrix is automatically removed in-line through a matrix elution step with organic solvent and nonaqueous anion-exchange analyte extraction. Acetic acid and formic acid, as the smallest and most acidic aliphatic naphthenic acids, were determined. Gradient anion-exchange chromatography on high-capacity columns in combination with suppressed conductivity detection allowed their selective and sensitive determination. Typical recovery values were from 82 to 107% for each acid in the matrices evaluated with reproducibility less than 5% for acid fortified samples.
- 1 November 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1370, 63-69
Using contemporary liquid chromatography theory and technology to improve capillary gradient ion-exchange separations
- 1 November 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1370, 63-69
Using contemporary liquid chromatography theory and technology to improve capillary gradient ion-exchange separations
- 1 August 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1355, 253-260
Design and performance evaluation of a microfluidic ion-suppression module for anion-exchange chromatography
- 1 August 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1355, 253-260
Design and performance evaluation of a microfluidic ion-suppression module for anion-exchange chromatography
- 2 November 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (24) , 3461-3468
Performance evaluation of ion‐exchange chromatography in capillary format
The performance of a recently introduced capillary ion‐exchange chromatography system was explored. Experiments were conducted in isocratic mode with a commercial capillary anion‐exchange column (id = 0.4 mm, L = 15 cm) using a five‐anion standard mixture. The achieved results were compared to the performance of a standard bore ion‐exchange system (id = 4 mm, L = 15 cm), which was considered as a reference. The first‐generation capillary columns exhibited a minimal reduced plate‐height value below two witnessing a good packing quality and system performance. However, compared to the standard bore system the capillary system displayed an increased apparent C‐term which could be due to a difference in packing morphology and/or possible external band‐broadening contributions. For fast separations, the standard bore system outperformed the capillary system, while for complex separations both systems performed nearly equally well. In addition, the retention characteristics of the capillary system were investigated. To illustrate the suitability of the capillary system, the analysis of real‐world water samples originating from two local Belgian rivers was demonstrated.
- 2 November 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (24) , 3461-3468
Performance evaluation of ion‐exchange chromatography in capillary format
The performance of a recently introduced capillary ion‐exchange chromatography system was explored. Experiments were conducted in isocratic mode with a commercial capillary anion‐exchange column (id = 0.4 mm, L = 15 cm) using a five‐anion standard mixture. The achieved results were compared to the performance of a standard bore ion‐exchange system (id = 4 mm, L = 15 cm), which was considered as a reference. The first‐generation capillary columns exhibited a minimal reduced plate‐height value below two witnessing a good packing quality and system performance. However, compared to the standard bore system the capillary system displayed an increased apparent C‐term which could be due to a difference in packing morphology and/or possible external band‐broadening contributions. For fast separations, the standard bore system outperformed the capillary system, while for complex separations both systems performed nearly equally well. In addition, the retention characteristics of the capillary system were investigated. To illustrate the suitability of the capillary system, the analysis of real‐world water samples originating from two local Belgian rivers was demonstrated.
- 2 August 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (16) , 7212-7217
Capillary Ion Chromatography at High Pressure and Temperature
The application of high pressure and temperature in ion chromatography (IC) can significantly improve the efficiency and reduce the analysis time. In this work, the kinetic-performance limits of capillary IC columns with inner diameters of 400 μm packed with 4 and 7 μm macroporous anion-exchange particles were investigated employing a capillary ion-exchange instrument allowing column pressures up to 34 MPa and column temperatures up to 80 °C. Plate heights below 10 μm could be realized using capillary columns packed with 4 μm particles. Compared to conventional IC using 7 μm particles and pressures up to 21 MPa, a 40% improvement in plate number could be achieved when working at the kinetic performance limits at 34 MPa and using columns packed with 4 μm particles. Using coupled columns with a total length of 400 mm, a mixture of seven anions was separated within 7.5 min while yielding 20 000 plates. Increasing the temperature improved the performance limits when operating in the C-term region (for fast IC separation using columns <75 cm). Temperature also affected the retention properties and hence the selectivity. At higher temperature, retention for monovalent ions was mainly governed by ion diameter. An increase in retention with temperature was observed for small ions, and there was a decrease for ions having a larger diameter. The retention factor for divalent and trivalent anions increased with temperature.
- 2 August 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (16) , 7212-7217
Capillary Ion Chromatography at High Pressure and Temperature
The application of high pressure and temperature in ion chromatography (IC) can significantly improve the efficiency and reduce the analysis time. In this work, the kinetic-performance limits of capillary IC columns with inner diameters of 400 μm packed with 4 and 7 μm macroporous anion-exchange particles were investigated employing a capillary ion-exchange instrument allowing column pressures up to 34 MPa and column temperatures up to 80 °C. Plate heights below 10 μm could be realized using capillary columns packed with 4 μm particles. Compared to conventional IC using 7 μm particles and pressures up to 21 MPa, a 40% improvement in plate number could be achieved when working at the kinetic performance limits at 34 MPa and using columns packed with 4 μm particles. Using coupled columns with a total length of 400 mm, a mixture of seven anions was separated within 7.5 min while yielding 20 000 plates. Increasing the temperature improved the performance limits when operating in the C-term region (for fast IC separation using columns <75 cm). Temperature also affected the retention properties and hence the selectivity. At higher temperature, retention for monovalent ions was mainly governed by ion diameter. An increase in retention with temperature was observed for small ions, and there was a decrease for ions having a larger diameter. The retention factor for divalent and trivalent anions increased with temperature.
- Open Access
- 20 April 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 403 (6) , 1671-1683
Analysis of urinary oligosaccharides in lysosomal storage disorders by capillary high-performance anion-exchange chromatography–mass spectrometry
Many lysosomal storage diseases are characterized by an increased urinary excretion of glycoconjugates and oligosaccharides that are characteristic for the underlying enzymatic defect. Here, we have used capillary high-performance anion-exchange chromatography (HPAEC) hyphenated to mass spectrometry to analyze free oligosaccharides from urine samples of patients suffering from the lysosomal storage disorders fucosidosis, α-mannosidosis, GM1-gangliosidosis, GM2-gangliosidosis, and sialidosis. Glycan fingerprints were registered, and the patterns of accumulated oligosaccharides were found to reflect the specific blockages of the catabolic pathway. Our analytical approach allowed structural analysis of the excreted oligosaccharides and revealed several previously unpublished oligosaccharides. In conclusion, using online coupling of HPAEC with mass spectrometric detection, our study provides characteristic urinary oligosaccharide fingerprints with diagnostic potential for lysosomal storage disorders.
- 20 April 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 403 (6) , 1671-1683
Open AccessAnalysis of urinary oligosaccharides in lysosomal storage disorders by capillary high-performance anion-exchange chromatography–mass spectrometry
Many lysosomal storage diseases are characterized by an increased urinary excretion of glycoconjugates and oligosaccharides that are characteristic for the underlying enzymatic defect. Here, we have used capillary high-performance anion-exchange chromatography (HPAEC) hyphenated to mass spectrometry to analyze free oligosaccharides from urine samples of patients suffering from the lysosomal storage disorders fucosidosis, α-mannosidosis, GM1-gangliosidosis, GM2-gangliosidosis, and sialidosis. Glycan fingerprints were registered, and the patterns of accumulated oligosaccharides were found to reflect the specific blockages of the catabolic pathway. Our analytical approach allowed structural analysis of the excreted oligosaccharides and revealed several previously unpublished oligosaccharides. In conclusion, using online coupling of HPAEC with mass spectrometric detection, our study provides characteristic urinary oligosaccharide fingerprints with diagnostic potential for lysosomal storage disorders.
- Open Access
- 10 June 2010
- Published by Wiley in The FEBS Journal
- Vol. 277 (14) , 2970-2986
Glycan profiling of urine, amniotic fluid and ascitic fluid from galactosialidosis patients reveals novel oligosaccharides with reducing end hexose and aldohexonic acid residues
Urine, amniotic fluid and ascitic fluid samples of galactosialidosis patients were analyzed and structurally characterized for free oligosaccharides using capillary high-performance anion-exchange chromatography with pulsed amperometric detection and online mass spectrometry. In addition to the expected endo-β-N-acetylglucosaminidase-cleaved products of complex-type sialylated N-glycans, O-sulfated oligosaccharide moieties were detected. Moreover, novel carbohydrate moieties with reducing-end hexose residues were detected. On the basis of structural features such as a hexose–N-acetylhexosamine–hexose–hexose consensus sequence and di-sialic acid units, these oligosaccharides are thought to represent, at least in part, glycan moieties of glycosphingolipids. In addition, C1-oxidized, aldohexonic acid-containing versions of most of these oligosaccharides were observed. These observations suggest an alternative catabolism of glycosphingolipids in galactosialidosis patients: oligosaccharide moieties from glycosphingolipids would be released by a hitherto unknown ceramide glycanase activity. The results show the potential and versatility of the analytical approach for structural characterization of oligosaccharides in various body fluids.
- 10 June 2010
- Published by Wiley in The FEBS Journal
- Vol. 277 (14) , 2970-2986
Open AccessGlycan profiling of urine, amniotic fluid and ascitic fluid from galactosialidosis patients reveals novel oligosaccharides with reducing end hexose and aldohexonic acid residues
Urine, amniotic fluid and ascitic fluid samples of galactosialidosis patients were analyzed and structurally characterized for free oligosaccharides using capillary high-performance anion-exchange chromatography with pulsed amperometric detection and online mass spectrometry. In addition to the expected endo-β-N-acetylglucosaminidase-cleaved products of complex-type sialylated N-glycans, O-sulfated oligosaccharide moieties were detected. Moreover, novel carbohydrate moieties with reducing-end hexose residues were detected. On the basis of structural features such as a hexose–N-acetylhexosamine–hexose–hexose consensus sequence and di-sialic acid units, these oligosaccharides are thought to represent, at least in part, glycan moieties of glycosphingolipids. In addition, C1-oxidized, aldohexonic acid-containing versions of most of these oligosaccharides were observed. These observations suggest an alternative catabolism of glycosphingolipids in galactosialidosis patients: oligosaccharide moieties from glycosphingolipids would be released by a hitherto unknown ceramide glycanase activity. The results show the potential and versatility of the analytical approach for structural characterization of oligosaccharides in various body fluids.