SGStephen A. Graves

Stephen A. Graves

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephen A. Graves has a total of 271 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A full Monte Carlo reconstruction algorithm for improved precision via dual-photopeak Lu-177 imaging

    by Lucas A. Polson, Frederick Wilson, Joseph Grudzinski, Stephen A. Graves

  • Open Access

    Targeting CXCR4 with [ 212 Pb/ 203 Pb]-Pentixather Significantly Increases Overall Survival in Small Cell Lung Cancer

    by Keegan A. Christensen, Melissa A. Fath, Jordan T. Ewald, Claudia Robles-Planells, Stephen A. Graves, Spenser S. Johnson, Zeb R. Zacharias, Jon C.D. Houtman, M Sue O’dorisio, Michael K. Schultz, et al.

    Introduction: Small cell lung cancer (SCLC) has a 7% 5-year overall survival. C-X-C chemokine receptor 4 (CXCR4), an attractive target for theranostic agents, is highly expressed in SCLCs, and can be targeted with pentixather using the theranostic pair 212 Pb/ 203 Pb. The hypothesis that [ 212 Pb/ 203 Pb]-pentixather can be used safely and effectively for imaging and therapy in SCLC in xenograft models was tested. Results: SPECT/CT imaging and biodistribution studies of tumor bearing mice injected with [ 203 Pb]-pentixather demonstrated CXCR4-dependent uptake in tumors and accumulation of radioligand in kidneys and livers. Dosimetry calculations estimated [ 212 Pb]-pentixather uptake in tumor and normal tissue. [ 212 Pb]-pentixather treatment (37-111 kBq/g) of SCLC xenografts (DMS273 and H69AR) significantly prolonged survival and delayed tumor growth. When NSG mice grafted with human hCD34+ bone marrow were treated with [ 212 Pb]-pentixather (37-111 kBq/g), significant cytopenias were observed in peripheral blood complete blood counts (CBCs) at 13-18 days post treatment which resolved by day 28-31. Flow cytometry of bone marrow hematopeotic stem cells in these animals at day 28-31 demonstrated a significantly reduced frequency of the human hematopoietic marker CD45 (hCD45+) and reconstitution of the bone marrow with murine CD45+ (mCD45+) lineages. Conclusions: [ 203 Pb]-pentixather can be used to image CXCR4 expressing SCLC xenografts and treatment with alpha emitter [ 212 Pb]-pentixather significantly prolongs SCLC xenograft median overall survival. Significantly greater mCD45+ bone marrow repopulation was detected in NSG mice engrafted with human bone marrow 28-31 days following [ 212 Pb]-pentixather treatment, relative to hCD45+ bone marrow.


  • Open Access

    Lumbar and Thoracic Vertebrae Segmentation in CT Scans Using a 3D Multi-Object Localization and Segmentation CNN

    by Xiaofan Xiong, Stephen A. Graves, Brandie A. Gross, John M. Buatti, Reinhard R. Beichel

    Radiation treatment of cancers like prostate or cervix cancer requires considering nearby bone structures like vertebrae. In this work, we present and validate a novel automated method for the 3D segmentation of individual lumbar and thoracic vertebra in computed tomography (CT) scans. It is based on a single, low-complexity convolutional neural network (CNN) architecture which works well even if little application-specific training data are available. It is based on volume patch-based processing, enabling the handling of arbitrary scan sizes. For each patch, it performs segmentation and an estimation of up to three vertebrae center locations in one step, which enables utilizing an advanced post-processing scheme to achieve high segmentation accuracy, as required for clinical use. Overall, 1763 vertebrae were used for the performance assessment. On 26 CT scans acquired for standard radiation treatment planning, a Dice coefficient of 0.921 ± 0.047 (mean ± standard deviation) and a signed distance error of 0.271 ± 0.748 mm was achieved. On the large-sized publicly available VerSe2020 data set with 129 CT scans depicting lumbar and thoracic vertebrae, the overall Dice coefficient was 0.940 ± 0.065 and the signed distance error was 0.109 ± 0.301 mm. A comparison to other methods that have been validated on VerSe data showed that our approach achieved a better overall segmentation performance.


  • Open Access

    On the Use of 203Pb Imaging to Inform 212Pb Dosimetry for 203/212Pb Image-Guided Alpha-Particle Therapy for Cancer

    by Stephen Graves, Mengshi Li, Dongyoul Lee, Michael K. Schultz

    Alpha-emitting radiopharmaceutical therapy shows promise for improving the therapeutic efficacy of existing and future targeting ligands by limiting off-target irradiation and by preempting many cell survival mechanisms. Dosimetry-guided therapies are emerging as potentially safer and more effective than approaches based on a fixed-activity-administration paradigm. Among the candidates of alpha-emitting radionuclides, 212Pb shows promise for use under an image-guided dosimetry-informed theranostic paradigm, whereby 203Pb can be used for dosimetry and treatment planning. In this chapter, we model an approach to accurately estimate the dosimetry of 212Pb-based radiopharmaceuticals using 203Pb as a surrogate. However, uncertainties arise in dosimetric predictions for 212Pb based on 203Pb imaging due to the potential for migration of 212Pb radionuclide progeny (i.e., 212Bi, 212Po, 208Tl) from the site of 212Pb decay. On the other hand, based on distinct gamma-ray energies of the 212Pb progeny, the design of in vivo experiments is described that have the potential to define these uncertainties more precisely, so as to gain insights into the potential toxicity of bioconjugated and potentially decoupled 212Bi in tissues. The promise of alpha-particle radionuclide therapy is evidenced by a tenfold increase in publications over the last 30 years, and it is anticipated that the elementally matched 203Pb/212Pb radionuclide pair will play a key role in our progress toward personalized receptor-targeted alpha-particle therapy for cancer.


  • Open Access

    Head and Neck Cancer Segmentation in FDG PET Images: Performance Comparison of Convolutional Neural Networks and Vision Transformers

    by Xiaofan Xiong, Brian J. Smith, Stephen A. Graves, Michael M. Graham, John M. Buatti, Reinhard R. Beichel

    Convolutional neural networks (CNNs) have a proven track record in medical image segmentation. Recently, Vision Transformers were introduced and are gaining popularity for many computer vision applications, including object detection, classification, and segmentation. Machine learning algorithms such as CNNs or Transformers are subject to an inductive bias, which can have a significant impact on the performance of machine learning models. This is especially relevant for medical image segmentation applications where limited training data are available, and a model’s inductive bias should help it to generalize well. In this work, we quantitatively assess the performance of two CNN-based networks (U-Net and U-Net-CBAM) and three popular Transformer-based segmentation network architectures (UNETR, TransBTS, and VT-UNet) in the context of HNC lesion segmentation in volumetric [F-18] fluorodeoxyglucose (FDG) PET scans. For performance assessment, 272 FDG PET-CT scans of a clinical trial (ACRIN 6685) were utilized, which includes a total of 650 lesions (primary: 272 and secondary: 378). The image data used are highly diverse and representative for clinical use. For performance analysis, several error metrics were utilized. The achieved Dice coefficient ranged from 0.833 to 0.809 with the best performance being achieved by CNN-based approaches. U-Net-CBAM, which utilizes spatial and channel attention, showed several advantages for smaller lesions compared to the standard U-Net. Furthermore, our results provide some insight regarding the image features relevant for this specific segmentation application. In addition, results highlight the need to utilize primary as well as secondary lesions to derive clinically relevant segmentation performance estimates avoiding biases.


  • Open Access

    Pre-clinical Evaluation of Biomarkers for Early Detection of Nephrotoxicity Following Alpha-particle Radioligand Therapy

    by Mengshi Li, Claudia Robles-Planells, Dijie Liu, Stephen A. Graves, Gabriela Vasquez-Martinez, Gabriel Mayoral-Andrade, Dongyoul Lee, Prerna Rastogi, Brenna M. Marks, Edwin A. Sagastume, et al.

    Purpose: Cancer treatment with alpha-emitter-based radioligand therapies (α-RLTs) demonstrates promising tumor responses. Radiolabeled peptides are filtered through glomeruli, followed by potential reabsorption of a fraction by proximal tubules, which may cause acute kidney injury (AKI) and chronic kidney disease (CKD). Because tubular cells are considered the primary site of radiopeptides’ renal reabsorption and potential injury, the current use of kidney biomarkers of glomerular functional loss limits the evaluation of possible nephrotoxicity and its early detection. This study aimed to investigate whether urinary secretion of tubular injury biomarkers could be used as additional non-invasive sensitive diagnostic tool to identify unrecognizable tubular damage and risk of long-term α-RLTs nephrotoxicity. Methods: A bifunctional cyclic peptide, melanocortin ligand-1(MC1L), labeled with [ 203 Pb]Pb-MC1L, was used for [ 212 Pb]Pb-MC1L biodistribution and absorbed dose measurements in CD-1 Elite mice. Mice were treated with [ 212 Pb]Pb-MC1L in a dose escalation study up to levels of radioactivity intended to induce kidney injury. The approach enabled prospective kidney functional and injury biomarker evaluation and late kidney histological analysis to validate these biomarkers. Results: Biodistribution analysis identified [ 212 Pb]Pb-MC1L reabsorption in kidneys with a dose deposition of 2.8, 8.9, and 20 Gy for 0.9, 3.0, and 6.7 MBq injected [ 212 Pb]Pb-MC1L doses, respectively. As expected, mice receiving 6.7 MBq had significant weight loss and CKD evidence based on serum creatinine, cystatin C, and kidney histological alterations 28 weeks after treatment. A dose-dependent urinary Neutrophil gelatinase-associated lipocalin (NGAL, tubular injury biomarker) urinary excretion the day after [ 212 Pb]Pb-MC1L treatment highly correlated with the severity of late tubulointerstitial injury and histological findings. Conclusion: urine NGAL secretion could be a potential early diagnostic tool to identify unrecognized tubular damage and predict long-term α-RLT-related nephrotoxicity.


  • Radiation Safety Considerations of Household Waste Disposal After Release of Patients Who Have Received [177Lu]Lu-PSMA-617

    by Stephen A. Graves

    Patients with metastatic prostate cancer are more likely than other groups to present for radiopharmaceutical therapy with urinary incontinence due to complications from prior local prostate cancer treatment. A consequence of urinary incontinence in patients receiving radiopharmaceutical therapy is the potential production of contaminated solid waste, which must be managed by the licensee and, at home, managed by and disposed of by the patient. Prolonging the patient stay in the treating facility after radiopharmaceutical therapy administration, until the first urinary void or potentially overnight, may moderately reduce the quantity of contaminated waste being managed by the patient at home. However, this approach does not fully mitigate the need for a patient waste-management strategy. In this brief communication, the relative radiation safety merits of contaminated waste disposal in the normal household waste stream in comparison to other waste management strategies are evaluated. Visual Abstract


  • Practical Considerations for Implementation of177Lu-DOTATATE Neuroendocrine Tumor Treatment Programs

    by Diane K. Soulek, Molly E. Martin, Nic J. Mastascusa, Stephen A. Graves

    The 2018 FDA approval of 177Lu-DOTATATE for the treatment of somatostatin receptor-positive (SSTR) neuroendocrine tumors (NETs) represents a paradigm shifting approach to cancer treatments around the globe. Gastroenteropancreatic (GEP) NETs overexpress the somatostatin subtype receptor 2, which is now exploited for receptor-based imaging and therapy, thus generating significant progress in the diagnosis and treatment of this orphan disease. The recent FDA approval of receptor-based PET radiopharmaceuticals and a new peptide receptor radiopharmaceutical therapy (PRRT), 177Lu-DOTATATE, has dramatically impacted NET patient management. The focus of this paper is to review clinical considerations associated with implementing a 177Lu-DOTATATE program. We review receptor-based NET radiopharmaceuticals, 177Lu-DOTATATE patient selection criteria, administration methods, clinical, regulatory, and radiation safety considerations, technical factors, tissue dosimetry, and reimbursement guidelines.


  • SIR-Spheres Activity Measurements Reveal Systematic Miscalibration

    by Stephen A. Graves, Molly Martin, Ashok Tiwari, Michael J Merrick, John J Sunderland

    Purpose: Accurate dosimetry-guided radiopharmaceutical therapy fundamentally relies on knowledge of the quantity of radioactivity administered to patients. The purpose of this work was to perform an independent and NIST-traceable activity measurement of 90Y SIR-Spheres®. Methods: Gamma spectroscopic measurements of the 90Y internal pair production decay mode were made using a high-purity germanium detector. Un-modified patient SIR-Spheres® vials were placed within a high-density polyethylene source holder positioned at a distance of 210 cm from the detector, with acquisition durations of 3 – 6 hours. Measured annihilation radiation detection rates were corrected for radioactive decay during acquisition, dead time, source attenuation, and source geometry effects. Detection efficiency was determined by two independent and NIST-traceable methods. Resulting 90Y activity measurements were compared against the manufacturer activity calibration. Results: Measured SIR-Sphere® vials (n = 5) were found to contain more activity than specified by the manufacturer calibration – on average the ratio of measured activity to calibrated was 1.233 ± 0.030. Activity measurements made using two distinct efficiency calibration methods were found to agree within 1%. Uncertainty in individual measurements was dominated by counting statistical uncertainty (~2.5%), uncertainty in the internal pair production branching ratio of 90Y (1.5%), and efficiency calibration (1.2% – 1.9%). Conclusion: The primary SIR-Spheres® activity calibration appears to be a significant underestimate of true activity. This mis-calibration has likely been consistent for as long as the SIR-Sphere® product has been available. This finding should be independently verified, and steps should be taken by the manufacturer to establish an accurate and traceable activity standard.


  • Reimbursement Approaches for Radiopharmaceutical Dosimetry: Current Status and Future Opportunities

    by Stephen A. Graves, Alexandru Bageac, James R. Crowley, Denise A.M. Merlino

    Interest in performing dosimetry for clinical radiopharmaceutical therapy procedures has grown in recent years. Several approved therapies include dosimetry in the Food and Drug Administration–approved label instructions, and other therapies are best used under a patient-tailored paradigm. This paper, which is a product of the Society of Nuclear Medicine and Molecular Imaging Dosimetry Task Force, presents motivations and general workflows for radiopharmaceutical therapy dosimetry, as well as existing strategies for obtaining reimbursement for clinical activities related to dosimetry. Several specific patient examples are provided, including suggested codes for reimbursement. In addition to current reimbursement approaches, key dosimetry services that are not supported under the current coding structure are presented and suggested as areas of focus in the coming years.