PDPiotr Dunst

Piotr Dunst

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Piotr Dunst has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intercontinental frequency ratio measurement of 171 Yb and 88 Sr optical lattice clocks

    by Piotr Morzyński, Sławomir Bilicki, Marcin Bober, Domagoj Kovačić, Roman Ciuryło, Michał Zawada, Jerzy Nawrocki, Piotr Dunst, Takumi Kobayashi, Kazumoto Hosaka, et al.

    We report a remote, intercontinental frequency comparison between 171Yb (NMIJ) and 88Sr (UMK) optical lattice clocks. The frequencies were compared via the Global Positioning System Precise Point Positioning technique over the period from 10 March 2020, 00:00 UTC until 15 March 2020, 00:00 UTC. The comparison of the optical clocks yields results with a relative frequency uncertainty of 6.3 × 10 − 15 .


  • Operation of caesium fountain frequency standards with remote hydrogen maser references

    by K Szymaniec, R J Hendricks, K Turza, B Nagórny, P Dunst, J Nawrocki, P Krehlik, Ł Śliwczyński, A Czubla

    We report on the operation of a Cs fountain primary frequency standard using as a reference for its microwave source a hydrogen maser located in a remote laboratory up to hundreds of kilometres away. The 10 MHz reference signal for the microwave synthesizer is transferred via a dedicated optical fibre link with an electronically stabilized time delay. Such referencing to a remote maser was first tested with a 50 km spooled fibre on two separate fountain systems using either a quartz-based microwave source or an ultrastable optically-derived one. We subsequently ran two fountains with quartz-based local oscillators, one co-located with a referencing maser and the second linked to it by 34 km of buried optical fibre forming part of telecommunication infrastructure. Finally, the second fountain was referenced to a different maser located much farther away via a link extended to 390 km. We find that in all configurations the addition of the delay-stabilized fibre link, delivering the remote 10 MHz reference, does not degrade the short-term stability of the fountain standard—as long as the bandwidth of a servo locking the local oscillator to the maser reference is optimized.


  • Design and performance of Cs fountain frequency standards constructed for metrology laboratories

    by R.J. Hendricks, F. Ozimek, K. Szymaniec, P. Dunst, B. Nagorny, J. Nawrocki, S. Beattie, B. Jian, W. Chen, K. Gibble

    Following a refined NPL design, we have constructed several Cs fountain primary frequency standards for use in different metrology laboratories. In this paper we describe the design of these new systems and present measurements of their performance.

  • OPTIME - final release

    by L. Buczek, J. Kolodziej, P. Krehlik, M. Lipinski, L. Sliwczynski, A. Binczewski, W. Bogacki, P. Ostapowicz, M. Stroinski, K. Turza, et al.

    The OPTIME project creates an ultra-precise time and frequency signals dissemination system based on telecommunication networks. End users obtain access to these signals without incurring huge costs for the purchase of their own atomic clocks, and receive the service related to laboratories generating international atomic time scales, to which any precise time must be referred. This document describes the final stage of OPTIME project - which developed a self-calibrating, high precision dissemination system for time and frequency reference signals based on optical fiber links and ELSTAB devices developed at AGH University.


  • Open Access

    Absolute measurement of the 1S0 − 3P0 clock transition in neutral 88Sr over the 330 km-long stabilized fibre optic link

    by Piotr Morzyński, Marcin Bober, Dobrosława Bartoszek-Bober, Jerzy Nawrocki, Przemysław Krehlik, Łukasz Śliwczyński, Marcin Lipiński, Piotr Masłowski, Agata Cygan, Piotr Dunst, et al.

    We report a stability below 7 × 10−17 of two independent optical lattice clocks operating with bosonic 88Sr isotope. The value (429 228 066 418 008.3(1.9)syst (0.9)stat Hz) of the absolute frequency of the 1S0 – 3P0 transition was measured with an optical frequency comb referenced to the local representation of the UTC by the 330 km-long stabilized fibre optical link. The result was verified by series of measurements on two independent optical lattice clocks and agrees with recommendation of Bureau International des Poids et Mesures.


  • OPTIME - the system grows - a new 330 km line

    by L. Buczek, J. Kolodziej, P. Krehlik, M. Lipinski, L. Sliwczynski, A. Binczewski, W. Bogacki, P. Ostapowicz, M. Stroinski, K. Turza, et al.

    The OPTIME project creates an ultra-precise time and frequency signals dissemination system based on telecommunication networks. End users obtain access to these signals without incurring huge costs for the purchase of their own atomic clocks, and receive the service related to laboratories generating international atomic time scales, to which any precise time must be referred. OPTIME dissemination system is based on three main elements: reference time and frequency laboratories, local time and frequency repositories and fiber optical network with specialized transmission equipment to transfers signals between laboratories, repositories and end users. This article describes OPTIME system with particular emphasis on a new 330 km long dissemination line between Space Research Centre PAS, Astrogeodynamic Observatory (AOS) at Borowiec and National Laboratory of Atomic, Molecular and Optical Physics (KL FAMO) at Torun.


  • OPTIME - Time and frequency dissemination system based on fiber optical network - Local repository project

    by L. Buczek, J. Kolodziej, P. Krehlik, M. Lipinski, L. Sliwczynski, A. Czubla, W. Adamowicz, J. Igalson, T. Pawszak, J. Pieczerak, et al.

    The main goal of OPTIME project is to design and to create an infrastructure for a long range dissemination system for transfer of ultraprecise time scale and reference frequency signals in telecommunication networks. OPTIME dissemination system is based on three main elements: reference time and frequency laboratories, local time and frequency repositories and fiber optical network with specialized transmission equipment to transfers signals between laboratories, repositories and end-users. This article describes all elements of OPTIME system with particular emphasis on local time and frequency repositories. Moreover this article also describes experience gained during more than two years of experiments on fiber connection between Central Office of Measures (GUM) in Warsaw and the Astrogeodynamic Observatory (AOS) in Borowiec, which are reference laboratories in OPTIME system.

  • Towards the distribution network of time and frequency

    by M. Lipinski, P. Krehlik, L. Sliwczynski, L. Buczek, J. Kolodziej, J. Nawrocki, P. Nogas, P. Dunst, D. Lemanski, A. Czubla, et al.

  • Precise Point Positioning technique for short and long baselines time transfer

    by P. Lejba, J. Nawrocki, D. Lemanski, P. Nogas, P. Dunst

    In this work the clock parameters determination of several timing receivers TTS-4 (AOS, PL), ASHTECH-Z-XII3T (PTB, USNO) and SEPTENTRIO POLARX4TR (ORB,) by use of the Precise Point Positioning (PPP) technique were presented. The clock parameters were determined for several time links based on the data delivered by time and frequency laboratories mentioned above. The computations cover the period from June 1 2012 to May 31, 2013 and were performed in two modes with 7-day and one-month solution for all links. All RINEX data files which include phase and code GPS data were recorded in 30-second intervals. All calculations were performed by means of Natural Resource Canada's GPS Precise Point Positioning (GPS-PPP) software based on high-quality precise satellite coordinates and satellite clock delivered by IGS as the final products. The received results were compared with the results obtained by GPS CV and TWSTFT. The used independent PPP technique is a very powerful and simple method which allows for better control of antenna positions in AOS and a verification of other time transfer techniques like GPS CV, GLONASS CV and TWSTFT. The precision of the PPP technique is only comparable to the glass fiber link PL-AOS realized at present by PL and AOS time labs. Currently PPP technique is one of the main time transfer methods used at AOS considerably improving and strengthening the quality of the Polish time scales UTC(AOS), UTC(PL), and TA(PL).


  • OPTIME — Time and frequency dissemination system based on fiber optical network — PIONIER

    by L. Buczek, J. Kolodziej, P. Krehlik, M. Lipinski, L. Sliwczynski, A. Czubla, A. Binczewski, W. Bogacki, P. Ostapowicz, M. Stroinski, et al.

    The OPTIME project creates a long range dissemination system for transfer ultraprecise time scale and the references frequency signals in telecommunication networks. The highest accuracy signal is available only on fiber optical networks, but other type of networks can be used to transfer of signals with lower accuracy to adapt it to the needs of different user groups. Article also describes experience gained during an over-a-year experiment of connection between Central Office of Measures (GUM) in Warsaw and the Astrogeodynamic Observatory (AOS) in Borowiec.