WYWilliam T. Yost

William T. Yost

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William T. Yost has a total of 103 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nondestructive evaluation of interfacial bond strength in single lap joints via swept-frequency ultrasonic phase measurements

    by Harold A. Haldren, Daniel F. Perey, William T. Yost, K. Elliott Cramer, Mool C. Gupta

    As adhesive bonding is a preferred method of joining advanced composite structures for modern aerospace and automotive designs, the need for a quantitative nondestructive evaluation (NDE) method for adhesive bond strength has sharply increased. For many years, adhesively bonded joints have been examined with conventional NDE methods, but none have proved able to detect weak or “kissing” bonds, except where major bonding defects occur. Here, the problem of weak interfacial bonding is investigated with a novel swept-frequency ultrasonic phase measurement method. High- resolution, swept-frequency ultrasonic phase measurements are obtained at each frequency through the use of a constant- frequency pulsed phase-lock-loop instrument. The method is tested on single lap joints fabricated with polished glass adherents and adhesive cured with ultraviolet (UV) light. The cohesive and adhesive bonding properties are modified by varying the adhesive’s exposure time to UV light and thereby changing the degree-of-cure. After fitting the measured phase response to a model of the ultrasonic response of the bonded joint, the stiffness constant of the adhesive/adherent interface is found. The interfacial stiffness constant is shown to have a strong linear correlation with measured mechanical tensile strength. As such, high-resolution swept-frequency phase measurements are shown to have a sensitivity to interfacial bond strength without the presence of gross bonding defects, allowing for bond strength quantification rather than a simple identification of “good” or “bad” bonding. This method has the potential to be a quality control and service life assessment method for both newly-fabricated and in-service bonded joints for the aerospace, automotive, and other industries.


  • Optically stimulated electron emission analysis of surface contamination levels on epoxy composites and effect on failure mode of adhesively bonded specimens

    by Rodolfo I. Ledesma, William T. Yost, Frank L. Palmieri, John W. Connell

    Adhesive bonding is adversely affected by contamination on the adherend surfaces. Various surface monitoring techniques have been developed to assure that surfaces are sufficiently free from those contaminants, which can be adsorbed on to the adherend surfaces prior to applying the adhesive and degrade bond performance. Contaminants, even at low concentrations, can pose a risk to adhesive bonding and the durability of the bonded structure. It remains a challenge to measure residual surface concentrations of critical contaminant molecules (e.g. molecules from mold release agents) by current surface control procedures. Recently, we have made advances in an existing technique, optically stimulated electron emission (OSEE), originally developed for detection of contamination on metallic surfaces. Improvements in instrument design and in measurement analysis have extended this measurement modality to low levels of molecular species of contaminants on carbon fiber reinforced polymer (CFRP) materials. In this work, we present the basics of the measurement analysis and give some typical measurement results on smooth and laser ablated surfaces. We confirm the mercury spectral absorption mechanism of the contaminant species polydimethylsiloxane (PDMS), a major component of silicone-based mold release agents. Effects of PDMS levels on adhesive bond performance through analysis of double cantilever beam (DCB) testing is shown. Service life implications from failure modes of adhesive bonding onto PDMS-contaminated surfaces are made.


  • Swept-frequency ultrasonic phase evaluation of adhesive bonding in tri-layer structures

    by Harold A. Haldren, Daniel F. Perey, William T. Yost, K. Elliott Cramer, Mool C. Gupta

    As modern aerospace and automotive designs continually strive for higher performance, and thus rely on advanced composite structures where adhesive bonding is a preferred method of joining, the need for a robust quantitative nondestructive bond strength measurement method has increased. As such, advanced nondestructive evaluation methods have been researched for increased sensitivity to weak interfacial bonding and ultimately to detect “kissing” bonds. In this work, a phase-based method for interrogating bonded joints and detecting weak adhesion is developed by using swept-frequency phase measurements of ultrasonic waves reflected from an adhesive joint and modeling adhesive interfaces as a distributed spring system. The method's sensitivity to bond strength is explored by ultrasonic phase evaluation of tri-layer joints with bond quality varied by controlling ultraviolet light exposure and extracting interfacial stiffness constants of the bonds. Mechanical tensile tests found each joint failed adhesively, allowing a linear correlation to be drawn between interfacial stiffness and tensile strength, consistent with previous theoretical research. The ultrasonic phase measurement method identifies intermediate bond strengths, rather than simply detecting good or bad bonds. This technique has the potential for the verification of bond quality in lightweight aerospace and automotive designs utilizing advanced composite structures with adhesive attachments.


  • Correlation of Trace Silicone Contamination Analyses on Epoxy Composites Using X-ray Photoelectron Spectroscopy (XPS) and Laser-Induced Breakdown Spectroscopy (LIBS)

    by Rodolfo Ledesma, Frank Palmieri, Brooke Campbell, William Yost, James Fitz-Gerald, Giles Dillingham, John Connell

    Surface treatment and surface characterization techniques are critical to ensure that adherends are chemically activated and free of contaminants before adhesive bonding. Silicone contamination from mold release agents and other sources can interfere with interfacial bonding, decreasing the durability and performance of bonded composite structures. It is necessary to have tools and methods that can be used in a production environment to reliably detect low levels of contaminants in a rapid, simple, and cost-effective manner to improve bond reliability. In this work, surface characterization of carbon fiber reinforced polymer (CFRP) composites with epoxy matrix was performed using laser-induced breakdown spectroscopy (LIBS), and the results were compared with those obtained from X-ray photoelectron spectroscopy (XPS). Laser-induced breakdown spectroscopy offers many advantages over XPS in terms of ease of use, sample preparation, and real-time results. The objective of the comparison was to study the sensitivity of LIBS and to investigate the quantification of the surface species measured by LIBS. Another objective was to assess the reliability of each technique for surface contaminant characterization. The as-processed CFRP panels had trace surface silicone contamination from the fabrication process, the source of which was not investigated. The composites were laser treated at select average laser power levels, resulting in varying levels of contamination reduction. The Si atomic percentage measurements using XPS were conducted on both control and laser-ablated surfaces. The results showed an excellent correlation in Si concentration between the two techniques.


  • A digital, constant-frequency pulsed phase-locked-loop instrument for real-time, absolute ultrasonic phase measurements

    by H. A. Haldren, D. F. Perey, W. T. Yost, K. E. Cramer, M. C. Gupta

    A digitally controlled instrument for conducting single-frequency and swept-frequency ultrasonic phase measurements has been developed based on a constant-frequency pulsed phase-locked-loop (CFPPLL) design. This instrument uses a pair of direct digital synthesizers to generate an ultrasonically transceived tone-burst and an internal reference wave for phase comparison. Real-time, constant-frequency phase tracking in an interrogated specimen is possible with a resolution of 0.000 38 rad (0.022°), and swept-frequency phase measurements can be obtained. Using phase measurements, an absolute thickness in borosilicate glass is presented to show the instrument’s efficacy, and these results are compared to conventional ultrasonic pulse-echo time-of-flight (ToF) measurements. The newly developed instrument predicted the thickness with a mean error of −0.04 μm and a standard deviation of error of 1.35 μm. Additionally, the CFPPLL instrument shows a lower measured phase error in the absence of changing temperature and couplant thickness than high-resolution cross-correlation ToF measurements at a similar signal-to-noise ratio. By showing higher accuracy and precision than conventional pulse-echo ToF measurements and lower phase errors than cross-correlation ToF measurements, the new digitally controlled CFPPLL instrument provides high-resolution absolute ultrasonic velocity or path-length measurements in solids or liquids, as well as tracking of material property changes with high sensitivity. The ability to obtain absolute phase measurements allows for many new applications than possible with previous ultrasonic pulsed phase-locked loop instruments. In addition to improved resolution, swept-frequency phase measurements add useful capability in measuring properties of layered structures, such as bonded joints, or materials which exhibit non-linear frequency-dependent behavior, such as dispersive media.


  • Light diffraction by large amplitude ultrasonic waves

    by Laszlo Adler, John H. Cantrell, William T. Yost

    Light diffraction from ultrasound, which can be used to investigate nonlinear acoustic phenomena in liquids, is reported for wave amplitudes larger than that typically reported in the literature. Large amplitude waves result in waveform distortion due to the nonlinearity of the medium that generates harmonics and produces asymmetries in the light diffraction pattern. For standing waves with amplitudes above a threshold value, subharmonics are generated in addition to the harmonics and produce additional diffraction orders of the incident light. With increasing drive amplitude above the threshold a cascade of period-doubling subharmonics are generated, terminating in a region characterized by a random, incoherent (chaotic) diffraction pattern. To explain the experimental results a toy model is introduced, which is derived from traveling wave solutions of the nonlinear wave equation corresponding to the fundamental and second harmonic standing waves. The toy model reduces the nonlinear partial differential equation to a mathematically more tractable nonlinear ordinary differential equation. The model predicts the experimentally observed cascade of period-doubling subharmonics terminating in chaos that occurs with increasing drive amplitudes above the threshold value. The calculated threshold amplitude is consistent with the value estimated from the experimental data.


  • Subharmonic generation, chaos, and subharmonic resurrection in an acoustically driven fluid-filled cavity

    by John H. Cantrell, Laszlo Adler, William T. Yost

    Traveling wave solutions of the nonlinear acoustic wave equation are obtained for the fundamental and second harmonic resonances of a fluid-filled cavity. The solutions lead to the development of a non-autonomous toy model for cavity oscillations. Application of the Melnikov method to the model equation predicts homoclinic bifurcation of the Smale horseshoe type leading to a cascade of period doublings with increasing drive displacement amplitude culminating in chaos. The threshold value of the drive displacement amplitude at tangency is obtained in terms of the acoustic drive frequency and fluid attenuation coefficient. The model prediction of subharmonic generation leading to chaos is validated from acousto-optic diffraction measurements in a water-filled cavity using a 5 MHz acoustic drive frequency and from the measured frequency spectrum in the bifurcation cascade regime. The calculated resonant threshold amplitude of 0.2 nm for tangency is consistent with values estimated for the experimental set-up. Experimental evidence for the appearance of a stable subharmonic beyond chaos is reported.