VRVenkata R. Reddy

Venkata R. Reddy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Venkata R. Reddy has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modulated Dual-Voltage-Vector Model-Free Predictive Current Controller for Synchronous Reluctance Motor Drives With Online Duty Cycle Calculation

    by Venkata R. Reddy, Crestian Almazan Agustin, Cheng-Kai Lin, Jung-Chieh Chen

    In this paper, a modulated dual-voltage-vector model-free predictive current control with online duty cycle calculation is proposed and applied to drive a synchronous reluctance motor. The dual-voltage-vector modulation scheme reduces the current ripples and errors in the single-voltage-vector method. The proposed method reduces the predictive current controller’s calculation time by first setting the initial value of the duty cycle to a constant. Then, an optimal switching mode can be selected by minimizing a cost function. Next, the required duty cycle can be calculated directly by the proposed method without any differential calculations instead of its initial value. The proposed method can effectively track the stator current, reducing the maximum average current error by 34.8% compared to the conventional single-voltage-vector scheme. Finally, the correctness and feasibility of the modulated model-free predictive current controller with the online duty cycle calculation proposed in this article are verified by the experimental results using Texas Instruments microcontroller TMS320F28379D.


  • A Hybrid Islanding Detection Method for One Cycle Controlled PV Inverter System

    by Venkata R. Reddy, E. S. Sreeraj

    Features like phase-locked-loop free implementation, simple-structure, grid voltage sensor-less operation, and its feedback response make one-cycle-control (OCC) inverters suitable and cost-effective for small singlephase photovoltaic distributed-generator (DG) units. The feedback nature of OCC makes passive islanding detection more effective in comparison with other control methods. A novel hybrid islanding detection method (IDM), which is suitable for OCC inverters, is proposed in this paper. The hybridization is done in two levels and is aimed at reducing the non-detection zone (NDZ) of the existing feedback based passive IDM. The passive first level defense, which is always present, is due to the feedback-nature of OCC. When islanding is suspected, the active second level defense is initiated by injecting a short real power disturbance. This accelerates the feedback action and helps in timely detection of islanding. Unlike other active methods, the disturbance is injected only when an islanding condition is suspected. The induced disturbance in real power is momentary, and the inverter goes back to the normal operation under non-islanded conditions. Simulation and experimental studies are performed to verify the effectiveness of the proposed IDM.


  • A Feedback Based Hybrid Islanding Detection Method and Voltage Ride-Through of One Cycle Controlled PV Inverter

    by Venkata R Reddy, Es Sreeraj

    One cycle control (OCC) based single-phase grid connected inverters are becoming popular for photovoltaic (PV) distributed generator (DG) units, because of its simple structure, cost-effectiveness and phase-locked-loop free implementation. The grid connected DG unit should have a robust islanding detection mechanism incorporated into it. This paper proposes a novel hybrid islanding detection method (IDM), which is suitable for OCC based DG systems. The nature of the OCC based inverter, which drives the VPCC away from the normal operating voltage during an islanding event is utilized to incorporate a feedback based IDM. However, when the difference between the inverter output power and the load power is near to zero, this IDM may fail to detect the condition. To overcome this drawback, a hybrid IDM, which combines the feedback effect and injection of real power disturbance, is proposed. The proposed method, unlike other active methods, injects disturbance into the grid only when an islanding condition is suspected. The induced change in power delivered by the inverter is only for a small duration of time, and the inverter goes back to the normal operation under non-islanded condition. A simple voltage ride-through which meets the recent standards for grid integration is integrated with the proposed IDM. Simulation studies are performed to verify the effectiveness of the proposed IDM.


  • A Feedback-Based Passive Islanding Detection Technique for One-Cycle-Controlled Single-Phase Inverter Used in Photovoltaic Systems

    by Venkata R. Reddy, Sreeraj E.S.

    Single-stage, single-phase photovoltaic (PV) distributed generation (DG) systems rated below 5 kW are becoming popular because of the reduction in the cost of PV panels and also due to various policy initiatives. One cycle control (OCC) based inverters are ideally suitable for such DG systems because of its cost-effectiveness, simple structure, and phase-locked loop free implementation. These inverter-based DG systems should have a robust islanding detection method (IDM) incorporated into it and should fulfill the recent standard requirements. This article proposes a novel feedback-based passive IDM, which is suitable for OCC-based grid-connected PV inverter system. The proposed method relies on the inbuilt feedback nature of OCC-based system, which drives the voltage at the point of common coupling outside the normal range of operation during an islanding condition. The proposed IDM works effectively under the new standard requirements with negligible nondetection zone. The IDM does not rely on additional computational effort or injection of external disturbance into the grid. Simulation studies are performed to verify the effectiveness of the proposed IDM. A laboratory prototype has been developed, and experimental studies are conducted to ascertain the viability of the proposed method.


  • Integration of ripple correlation MPPT technique with one-cycle-controlled transformerless inverter for single-phase single-stage photovoltaic systems

    by Venkata R. Reddy, E. S. Sreeraj

    With the advent of distributed generation, single-phase rooftop solar photovoltaic (PV) generators of small rating, feeding power to the utility grid has become popular. Cost and performance of the inverters used to integrate such systems to the grid depends upon the topology of the inverter used, modulation scheme employed, and the efficiency of auxiliary functions like maximum power point tracking (MPPT). The appropriate modulation scheme is generally decided by looking at the topology of inverter. For example, a transformerless H-bridge inverter is generally switched using bipolar modulation in order to avoid large leakage currents. However, selecting the appropriate technique for auxiliary functions like MPPT, is done independently and is generally not integrated with the control scheme. A large number of MPPT techniques were proposed in the literature, and choosing an appropriate technique suitable for the chosen inverter topology and the modulation scheme might be advantageous. This paper proposes the integration of one cycle control (OCC) modulation scheme for single-phase single-stage transformerless PV inverter with ripple correlation control (RCC) MPPT technique. Detailed numerical simulation studies are carried out to verify the effectiveness of the proposed integrated method. Real-time simulation studies are also carried out using the real-time digital simulator (RTDS) to verify the efficacy of the system further.