Camila Maia Rabelo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Camila Maia Rabelo has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Giannella Samelli
Universidade de São Paulo, Brasil
9 shared publications - Carla Gentile Matas
Universidade de São Paulo, Faculdade de Medicina, Departamento de Fisioterapia, Fonoaudiologia e Terapia Ocupacional, São Paulo SP, Brazil
5 shared publications - Fernanda Yasmin Odila Maestri Miguel Padilha
I Universidade de São Paulo. Faculdade de Medicina. Departamento de Fisioterapia, Fonoaudiologia e Terapia Ocupacional. São Paulo, SP, Brasil
5 shared publications - Renata Rodrigues Moreira
Universidade de São Paulo, Brazil
5 shared publications - Eliane Schochat
Universidade de São Paulo, Brazil
4 shared publications - Isabela Martins Bensenor
Clinical and Epidemiological Research Center, University Hospital, University of São Paulo, São Paulo, Brazil
4 shared publications
Latest Publications
- Open Access
- 15 June 2026
- Vol. 60, e22
Hearing loss and postural balance performance in adults and the elderly in ELSA-Brazil
To investigate the association between hearing loss and postural balance in adults and the elderly participating in the Estudo Longitudinal da Saúde do Adulto (ELSA-Brazil - Longitudinal Study of Adult Health). Cross-sectional study with data from the fourth wave (2020–2025) of ELSA-Brazil, in the center of São Paulo. Sociodemographic, clinical, and audiological variables were analyzed. Hearing loss was defined by the average of the tonal thresholds (> 25 dBHL) in different criteria: PTA (0.5 kHz-2kHz), speech-frequency PTA (0.5 kHz-4kHz), and high-frequency PTA (3 kHz-8kHz), considering the better and the worst hearing ear. Balance was assessed using the modified Romberg test, in four progressive conditions (eyes open on a firm surface, eyes closed on a firm surface, eyes open on a soft surface, and eyes closed on a soft surface), with a binary classification (pass/fail). The outcome was performance in the balance test. A total of 540 participants were assessed, mostly women, self-declared white, mean age of 63.1 years, mean Body Mass Index (BMI) of 28.4 kg/m2, with higher education and income between R$ 1,245.00 and R$ 3,319.00. The rate of balance failure was 13.3%. The prevalence of hearing loss ranged from 13.7% to 59.8%, depending on the criteria used. There was an association between hearing loss and worse performance in the balance test, especially for high-frequency PTA. In the logistic regression models, there was a significant association between the explanatory variable age and failure in the balance test. After excluding the age variable, there was an association for hearing loss, BMI, schooling, and income. There was an association between hearing loss and poorer balance performance. The highest proportion of failures was for the hearing loss criterion that included high frequencies. Age was the most relevant explanatory variable in balance test performance, in addition to hearing loss, schooling, income, and BMI, emphasizing the need for a multifactorial view of this function.
- 15 June 2026
- Vol. 60, e22
Open AccessHearing loss and postural balance performance in adults and the elderly in ELSA-Brazil
To investigate the association between hearing loss and postural balance in adults and the elderly participating in the Estudo Longitudinal da Saúde do Adulto (ELSA-Brazil - Longitudinal Study of Adult Health). Cross-sectional study with data from the fourth wave (2020–2025) of ELSA-Brazil, in the center of São Paulo. Sociodemographic, clinical, and audiological variables were analyzed. Hearing loss was defined by the average of the tonal thresholds (> 25 dBHL) in different criteria: PTA (0.5 kHz-2kHz), speech-frequency PTA (0.5 kHz-4kHz), and high-frequency PTA (3 kHz-8kHz), considering the better and the worst hearing ear. Balance was assessed using the modified Romberg test, in four progressive conditions (eyes open on a firm surface, eyes closed on a firm surface, eyes open on a soft surface, and eyes closed on a soft surface), with a binary classification (pass/fail). The outcome was performance in the balance test. A total of 540 participants were assessed, mostly women, self-declared white, mean age of 63.1 years, mean Body Mass Index (BMI) of 28.4 kg/m2, with higher education and income between R$ 1,245.00 and R$ 3,319.00. The rate of balance failure was 13.3%. The prevalence of hearing loss ranged from 13.7% to 59.8%, depending on the criteria used. There was an association between hearing loss and worse performance in the balance test, especially for high-frequency PTA. In the logistic regression models, there was a significant association between the explanatory variable age and failure in the balance test. After excluding the age variable, there was an association for hearing loss, BMI, schooling, and income. There was an association between hearing loss and poorer balance performance. The highest proportion of failures was for the hearing loss criterion that included high frequencies. Age was the most relevant explanatory variable in balance test performance, in addition to hearing loss, schooling, income, and BMI, emphasizing the need for a multifactorial view of this function.
- Open Access
- 1 January 2026
- Published by Georg Thieme Verlag KG in International Archives of Otorhinolaryngology
- Vol. 30 (01) , 001-006
Assessment of Two Types of Headphones Used in a Tablet-Based Automated Hearing Screening Method in Different Noise Conditions
To compare the performance of two types of supra-aural headphones in both silence and noise in automated hearing screening in adults via tablet computers. Basic audiological assessments and audiometry screenings via tablet were conducted in silence and noise in 35 participants. The hearing screening application assesses frequencies of 1, 2, and 4 kHz (20 dBHL) and 0.5 kHz (30 dBHL) in each ear separately. Two different headphones were tested: TDH 39 (Telephonics Corporation) and Sennheiser HD 280 PRO (Sennheiser) (with passive noise cancellation)—in silence, white noise, and cafeteria noise, emitted in a free field. The screening results were compared with the gold standard (audiometry). The results of the 35 participants with Sennheiser HD 280 PRO were compatible with the gold standard in the 3 situations. With TDH 39, the results of 33 individuals in silence and 34 in white noise were compatible with the gold standard. Both headphones, in automated screening in silence and noise, had 100% sensitivity, more than 93% specificity, and more than 94% accuracy. Both headphones performed well in the tablet automated hearing screening in the three situations. The HD 280 PRO performed better in silence and noise regarding specificity and accuracy. In cafeteria noise, there was no difference between the two headphones.
- 1 January 2026
- Published by Georg Thieme Verlag KG in International Archives of Otorhinolaryngology
- Vol. 30 (01) , 001-006
Open AccessAssessment of Two Types of Headphones Used in a Tablet-Based Automated Hearing Screening Method in Different Noise Conditions
To compare the performance of two types of supra-aural headphones in both silence and noise in automated hearing screening in adults via tablet computers. Basic audiological assessments and audiometry screenings via tablet were conducted in silence and noise in 35 participants. The hearing screening application assesses frequencies of 1, 2, and 4 kHz (20 dBHL) and 0.5 kHz (30 dBHL) in each ear separately. Two different headphones were tested: TDH 39 (Telephonics Corporation) and Sennheiser HD 280 PRO (Sennheiser) (with passive noise cancellation)—in silence, white noise, and cafeteria noise, emitted in a free field. The screening results were compared with the gold standard (audiometry). The results of the 35 participants with Sennheiser HD 280 PRO were compatible with the gold standard in the 3 situations. With TDH 39, the results of 33 individuals in silence and 34 in white noise were compatible with the gold standard. Both headphones, in automated screening in silence and noise, had 100% sensitivity, more than 93% specificity, and more than 94% accuracy. Both headphones performed well in the tablet automated hearing screening in the three situations. The HD 280 PRO performed better in silence and noise regarding specificity and accuracy. In cafeteria noise, there was no difference between the two headphones.
- Top Cited Papers
- 9 February 2025
- Published by SAGE Publications in Journal of Alzheimer’s Disease
- Vol. 104 (1) , 283-293
Hearing loss and cognitive decline in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) during eight years of follow-up
Background: Hearing loss (HL) of moderate or higher grades is common in older adults with increasing prevalence as people age, rising from 12% at the age of 60 years to over 58% at 90 years. HL in midlife is one of the main potentially modifiable risk factors for dementia. It is estimated that 7% of dementia cases globally could be avoided if this risk factor was eliminated. However, much of the research conducted has been in high-income countries even though low- and middle-income countries have the highest prevalence of dementia. Objective: To study the association between HL and cognitive decline during eight years of follow-up in a Brazilian sample. Methods: Participants from the São Paulo center of the Brazilian Longitudinal Study of Adult Health were evaluated in three study waves (2008–10, 2012–14, and 2017–19). HL was defined as pure-tone audiometry above 25 dB in the better ear. Cognitive performance was evaluated with six tests related to memory, verbal fluency, and trail-making tests. A global cognitive z-score was derived from these tests. The association between HL and cognitive decline was evaluated with linear mixed-effects models adjusted for sociodemographic, lifestyle, and clinical factors. Results: Of 805 participants (mean age 51 ± 9 years, 52% women, 60% White), 62 had HL. During follow-up, HL was associated with faster global cognitive decline (β = −0.012, 95% CI = −0.023; 0.000, p = 0.039). Conclusions: HL was significantly associated with a faster rate of global cognitive decline after a median follow-up of eight years in a sample of middle-income country.
- 9 February 2025
- Published by SAGE Publications in Journal of Alzheimer’s Disease
- Vol. 104 (1) , 283-293
Top Cited PapersHearing loss and cognitive decline in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) during eight years of follow-up
Background: Hearing loss (HL) of moderate or higher grades is common in older adults with increasing prevalence as people age, rising from 12% at the age of 60 years to over 58% at 90 years. HL in midlife is one of the main potentially modifiable risk factors for dementia. It is estimated that 7% of dementia cases globally could be avoided if this risk factor was eliminated. However, much of the research conducted has been in high-income countries even though low- and middle-income countries have the highest prevalence of dementia. Objective: To study the association between HL and cognitive decline during eight years of follow-up in a Brazilian sample. Methods: Participants from the São Paulo center of the Brazilian Longitudinal Study of Adult Health were evaluated in three study waves (2008–10, 2012–14, and 2017–19). HL was defined as pure-tone audiometry above 25 dB in the better ear. Cognitive performance was evaluated with six tests related to memory, verbal fluency, and trail-making tests. A global cognitive z-score was derived from these tests. The association between HL and cognitive decline was evaluated with linear mixed-effects models adjusted for sociodemographic, lifestyle, and clinical factors. Results: Of 805 participants (mean age 51 ± 9 years, 52% women, 60% White), 62 had HL. During follow-up, HL was associated with faster global cognitive decline (β = −0.012, 95% CI = −0.023; 0.000, p = 0.039). Conclusions: HL was significantly associated with a faster rate of global cognitive decline after a median follow-up of eight years in a sample of middle-income country.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 35 (6) , e20220185
Avaliação das funções cognitivas em idosos com e sem alterações no processamento auditivo central
RESUMO Objetivo Avaliar e comparar as funções cognitivas entre idosos com e sem alteração do processamento auditivo central. Método Vinte e oito idosos saudáveis (14 do grupo controle e 14 do grupo Transtorno do Processamento Auditivo Central - TPAC) participaram do estudo. Todos os idosos foram submetidos à bateria mínima de avaliação do processamento auditivo central (PAC), ao potencial auditivo cognitivo P300 e a bateria cognitiva breve (BCB). Na comparação entre sujeitos, foi aplicado o teste de Mann-Whitney e na comparação intra-sujeitos, utilizamos o teste de postos sinalizados de Wilcoxon. Para verificar se houve associação entre o desempenho do PAC e das variáveis cognitivas, foi utilizada a correlação de Spearman. Resultados Não houve diferenças estatisticamente significantes entre os grupos ‘Controle’ e TPAC para a maioria das habilidades cognitivas avaliadas por meio da BCB, bem como para as variáveis do potencial cognitivo P300. Contudo, houve diferença estatisticamente significante entre o desempenho do grupo ‘Controle’ e TPAC para a prova do desenho do relógio. Além disso, foi possível observar correlação entre o desempenho do teste do relógio e no TPF. Conclusão Idosos com TPAC não apresentaram alteração na maior parte dos testes cognitivos, com exceção da prova do desenho do relógio, cuja tarefa envolve múltiplas funções cognitivas, incluindo processamento visuoespacial, função executiva, memória semântica e planejamento.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 35 (6) , e20220185
Open AccessAvaliação das funções cognitivas em idosos com e sem alterações no processamento auditivo central
RESUMO Objetivo Avaliar e comparar as funções cognitivas entre idosos com e sem alteração do processamento auditivo central. Método Vinte e oito idosos saudáveis (14 do grupo controle e 14 do grupo Transtorno do Processamento Auditivo Central - TPAC) participaram do estudo. Todos os idosos foram submetidos à bateria mínima de avaliação do processamento auditivo central (PAC), ao potencial auditivo cognitivo P300 e a bateria cognitiva breve (BCB). Na comparação entre sujeitos, foi aplicado o teste de Mann-Whitney e na comparação intra-sujeitos, utilizamos o teste de postos sinalizados de Wilcoxon. Para verificar se houve associação entre o desempenho do PAC e das variáveis cognitivas, foi utilizada a correlação de Spearman. Resultados Não houve diferenças estatisticamente significantes entre os grupos ‘Controle’ e TPAC para a maioria das habilidades cognitivas avaliadas por meio da BCB, bem como para as variáveis do potencial cognitivo P300. Contudo, houve diferença estatisticamente significante entre o desempenho do grupo ‘Controle’ e TPAC para a prova do desenho do relógio. Além disso, foi possível observar correlação entre o desempenho do teste do relógio e no TPF. Conclusão Idosos com TPAC não apresentaram alteração na maior parte dos testes cognitivos, com exceção da prova do desenho do relógio, cuja tarefa envolve múltiplas funções cognitivas, incluindo processamento visuoespacial, função executiva, memória semântica e planejamento.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 35 (6) , e20220185
Evaluation of cognitive functions in the elderly with and without central auditory processing disorder
Purpose Evaluate and compare the performance of cognitive functions between elderly with and without auditory processing disorders. Methods Twenty-eight healthy elderly (14 Control group and 14 Auditory Processing Disorder group - APD group) participated in the study. All elderly were submitted to (central) auditory processing evaluation, P300 event-related potential and brief cognitive battery (BCB). In the comparison between subjects, the Mann-Whitney test was applied and in the intra-subjects comparison, the Wilcoxon signed rank test was used. To verify if there was an association between the performance of the PAC and the cognitive variables, Spearman's correlation was used. Results There were no statistically significant differences between the Control and APD groups for the cognitive abilities assessed by BCB, as well as for the P300 cognitive potential variables. Conclusion Elderly with auditory processing disorders do not seem to show greater cognitive difficulties compared to elderly of the same age group without auditory processing disorders, exception of the clock drawing test, whose task involves multiple cognitive functions, including visuospatial processing, executive function, semantic memory, and planning.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 35 (6) , e20220185
Open AccessEvaluation of cognitive functions in the elderly with and without central auditory processing disorder
Purpose Evaluate and compare the performance of cognitive functions between elderly with and without auditory processing disorders. Methods Twenty-eight healthy elderly (14 Control group and 14 Auditory Processing Disorder group - APD group) participated in the study. All elderly were submitted to (central) auditory processing evaluation, P300 event-related potential and brief cognitive battery (BCB). In the comparison between subjects, the Mann-Whitney test was applied and in the intra-subjects comparison, the Wilcoxon signed rank test was used. To verify if there was an association between the performance of the PAC and the cognitive variables, Spearman's correlation was used. Results There were no statistically significant differences between the Control and APD groups for the cognitive abilities assessed by BCB, as well as for the P300 cognitive potential variables. Conclusion Elderly with auditory processing disorders do not seem to show greater cognitive difficulties compared to elderly of the same age group without auditory processing disorders, exception of the clock drawing test, whose task involves multiple cognitive functions, including visuospatial processing, executive function, semantic memory, and planning.
- Open Access
- 22 April 2022
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais in Revista de Saúde Pública
- Vol. 56, 28
ELSA-Brasil: a 4-year incidence of hearing loss in adults with and without hypertension
OBJECTIVE To compare the incidence of hearing loss among adults stratified by the occurrence of hypertension, and to investigate the association between hypertension and hearing loss. METHODS Longitudinal observational study, part of the Estudo Longitudinal da Saúde do Adulto (ELSA-Brasil, Longitudinal Study on Adult’s Health). Data from the first and second waves were analyzed, including information from audiological assessment and general health of the subjects. As outcome, we considered the presence of hearing loss (hearing thresholds above 25 dBHL at frequencies from 500 Hz to 8 kHz) and, as exposure variable, hypertension (report of medical diagnosis of hypertension; and/or use of drugs to treat hypertension; and/or pressure systolic blood pressure ≥ 140 mmHg; or diastolic blood pressure ≥ 90 mmHg). As covariables for adjustment were considered: sex, age, education, race / ethnicity, income, smoking, diabetes, and occupational exposure to noise. Poisson regression analysis was conducted, estimating the crude and adjusted relative risks, with 95% confidence intervals, in order to assess the factors associated with hearing loss. RESULTS In crude analyses, the incidence of hearing loss was higher for subjects with hypertension (9.7% versus 5.4%). The crude relative risks for hearing loss was almost double (1.93; 95%CI: 1.10–3.39) for subjects with hypertension in the right ear. In the adjusted analyses, the relative risks was not significant for the hypertension variable (1.42; 95%CI: 0.75–2.67). Being 60 years or older (RR: 5.41; 95%CI: 2.79–10.50) showed a statistically significant association with hearing loss, indicating that older adults have higher relative risks for hearing loss. CONCLUSION In the adjusted analyses controlled for multiple risk factors there was no association between hypertension and hearing loss. The dichotomous variable age (being 60 years or older), on the other hand, has shown a significant association with hearing loss.
- 22 April 2022
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais in Revista de Saúde Pública
- Vol. 56, 28
Open AccessELSA-Brasil: a 4-year incidence of hearing loss in adults with and without hypertension
OBJECTIVE To compare the incidence of hearing loss among adults stratified by the occurrence of hypertension, and to investigate the association between hypertension and hearing loss. METHODS Longitudinal observational study, part of the Estudo Longitudinal da Saúde do Adulto (ELSA-Brasil, Longitudinal Study on Adult’s Health). Data from the first and second waves were analyzed, including information from audiological assessment and general health of the subjects. As outcome, we considered the presence of hearing loss (hearing thresholds above 25 dBHL at frequencies from 500 Hz to 8 kHz) and, as exposure variable, hypertension (report of medical diagnosis of hypertension; and/or use of drugs to treat hypertension; and/or pressure systolic blood pressure ≥ 140 mmHg; or diastolic blood pressure ≥ 90 mmHg). As covariables for adjustment were considered: sex, age, education, race / ethnicity, income, smoking, diabetes, and occupational exposure to noise. Poisson regression analysis was conducted, estimating the crude and adjusted relative risks, with 95% confidence intervals, in order to assess the factors associated with hearing loss. RESULTS In crude analyses, the incidence of hearing loss was higher for subjects with hypertension (9.7% versus 5.4%). The crude relative risks for hearing loss was almost double (1.93; 95%CI: 1.10–3.39) for subjects with hypertension in the right ear. In the adjusted analyses, the relative risks was not significant for the hypertension variable (1.42; 95%CI: 0.75–2.67). Being 60 years or older (RR: 5.41; 95%CI: 2.79–10.50) showed a statistically significant association with hearing loss, indicating that older adults have higher relative risks for hearing loss. CONCLUSION In the adjusted analyses controlled for multiple risk factors there was no association between hypertension and hearing loss. The dichotomous variable age (being 60 years or older), on the other hand, has shown a significant association with hearing loss.
- 27 February 2021
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 28 (2) , 1227-1234
Effects of hearing protector devices on speech intelligibility: the importance of individualized assessment
Objectives. This study aimed to compare speech intelligibility in noise with and without hearing protection devices (HPDs). Methods. Fifty-one workers were distributed into three groups: noise-induced hearing loss group (NIHLG), normally hearing noise-exposed group (NG) and normally hearing non-exposed to noise group (CG). A free field system was used to emit monosyllables (65, 70 and 75 dB) and pink noise in different signal-to-noise ratios (SNRs) (0, −5, −10 and −15). Results. In situations with HPDs, all groups showed a decrease in the percentage of correct responses with an increase in noise level. The HPD had little effect on speech intelligibility in the NIHLG and NG. Considering the effect caused by the HPD on speech intelligibility, it was observed that the group with the greatest loss was the CG for SNRs of −5, −10 and −15. Conclusion. Although speech intelligibility is influenced by the hearing threshold, the noise level and SNR are crucial for good speech intelligibility, either with or without an HPD. It is highlighted that the NG had worse results when compared with the CG, which may indicate changes in the auditory pathway resulting from continuous noise exposure, even in the absence of changes in the audiometric thresholds.
- 27 February 2021
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 28 (2) , 1227-1234
Effects of hearing protector devices on speech intelligibility: the importance of individualized assessment
Objectives. This study aimed to compare speech intelligibility in noise with and without hearing protection devices (HPDs). Methods. Fifty-one workers were distributed into three groups: noise-induced hearing loss group (NIHLG), normally hearing noise-exposed group (NG) and normally hearing non-exposed to noise group (CG). A free field system was used to emit monosyllables (65, 70 and 75 dB) and pink noise in different signal-to-noise ratios (SNRs) (0, −5, −10 and −15). Results. In situations with HPDs, all groups showed a decrease in the percentage of correct responses with an increase in noise level. The HPD had little effect on speech intelligibility in the NIHLG and NG. Considering the effect caused by the HPD on speech intelligibility, it was observed that the group with the greatest loss was the CG for SNRs of −5, −10 and −15. Conclusion. Although speech intelligibility is influenced by the hearing threshold, the noise level and SNR are crucial for good speech intelligibility, either with or without an HPD. It is highlighted that the NG had worse results when compared with the CG, which may indicate changes in the auditory pathway resulting from continuous noise exposure, even in the absence of changes in the audiometric thresholds.
- Open Access
Hearing loss, tinnitus, and hypertension: analysis of the baseline data from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil)
To investigate the association among hypertension, tinnitus, and sensorineural hearing loss and evaluate the influence of other covariates on this association.Baseline data (2008-2010) from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) ...
Open AccessHearing loss, tinnitus, and hypertension: analysis of the baseline data from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil)
To investigate the association among hypertension, tinnitus, and sensorineural hearing loss and evaluate the influence of other covariates on this association.Baseline data (2008-2010) from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) ...
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Revista CEFAC
- Vol. 22 (2)
Audiological and electrophysiological assessment of professional orchestral musicians
Purpose: to verify whether the frequent musical exposure can impair peripheral and central auditory pathway responses in professional orchestral musicians. Methods: 45 male individuals from 19 to 40 years old participated in the study. They were divided into two groups: one comprising 30 orchestral musicians who played strings or wind instruments, and another with 15 nonmusicians. The two groups were submitted to both conventional and high-frequency pure-tone audiometry, transient-evoked otoacoustic emissions, and frequency-following response. The results were subjected to descriptive and inferential statistical analysis, using the one-way ANOVA unmatched samples parametric test, with a 5% significance level. Results: no significant differences were observed between the hearing thresholds in both conventional and high-frequency audiometry and frequency-following response. However, there were statistically significant differences between transient-evoked otoacoustic emission responses, with lower responses to musicians in comparison to the nonmusician group. Conclusion: the results suggest that frequent musical exposure experienced by orchestral musicians can impair the cochlear hair cells’ function. Therefore, audiological monitoring is important to detect subclinical impairments.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Revista CEFAC
- Vol. 22 (2)
Open AccessAudiological and electrophysiological assessment of professional orchestral musicians
Purpose: to verify whether the frequent musical exposure can impair peripheral and central auditory pathway responses in professional orchestral musicians. Methods: 45 male individuals from 19 to 40 years old participated in the study. They were divided into two groups: one comprising 30 orchestral musicians who played strings or wind instruments, and another with 15 nonmusicians. The two groups were submitted to both conventional and high-frequency pure-tone audiometry, transient-evoked otoacoustic emissions, and frequency-following response. The results were subjected to descriptive and inferential statistical analysis, using the one-way ANOVA unmatched samples parametric test, with a 5% significance level. Results: no significant differences were observed between the hearing thresholds in both conventional and high-frequency audiometry and frequency-following response. However, there were statistically significant differences between transient-evoked otoacoustic emission responses, with lower responses to musicians in comparison to the nonmusician group. Conclusion: the results suggest that frequent musical exposure experienced by orchestral musicians can impair the cochlear hair cells’ function. Therefore, audiological monitoring is important to detect subclinical impairments.
- 30 September 2018
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 26 (3) , 140-149
Tablet-based tele-audiometry: Automated hearing screening for schoolchildren
Introduction: To assess the performance of a tablet-based tele-audiometry method for automated hearing screening of schoolchildren through a comparison of the results of various hearing screening approaches. Methods: A total of 244 children were evaluated. Tablet-based screening results were compared with gold-standard pure-tone audiometry. Acoustic immittance measurements were also conducted. To pass the tablet-based screening, the children were required to respond to at least two out of three sounds for all the frequencies in each ear. Several hearing screening methods were analysed: exclusively tablet-based (with and without 500 Hz checked) and combined tests (series and parallel). The sensitivity, specificity, positive and negative predictive values and accuracy were calculated. Results: A total of 9.43% of children presented with mild to moderate conductive hearing loss (unilateral or bilateral). Diagnostic values varied among the different hearing screening approaches that were evaluated: sensitivities ranged from 60 to 95%, specificities ranged from 44 to 91%, positive predictive values ranged from 15 to 44%, negative predictive values ranged from 95 to 99%, accuracy values ranged from 49 to 88%, and area under curve values ranged from 0.690 to 0.883. Regarding diagnostic values, the highest results were found for the tablet-based screening method and for the series approach. Discussion: Compared with the results obtained by conventional audiometry and considering the diagnostic values of the different hearing screening approaches, the highest diagnostic values were generally obtained using the automated hearing screening method (including 500 Hz). Thus, this application, which was developed for the tablet computer, was shown to be a valuable hearing screening tool for use with schoolchildren. Therefore, we suggest that this hearing screening protocol has the potential to improve asynchronous tele-audiology service delivery.
- 30 September 2018
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 26 (3) , 140-149
Tablet-based tele-audiometry: Automated hearing screening for schoolchildren
Introduction: To assess the performance of a tablet-based tele-audiometry method for automated hearing screening of schoolchildren through a comparison of the results of various hearing screening approaches. Methods: A total of 244 children were evaluated. Tablet-based screening results were compared with gold-standard pure-tone audiometry. Acoustic immittance measurements were also conducted. To pass the tablet-based screening, the children were required to respond to at least two out of three sounds for all the frequencies in each ear. Several hearing screening methods were analysed: exclusively tablet-based (with and without 500 Hz checked) and combined tests (series and parallel). The sensitivity, specificity, positive and negative predictive values and accuracy were calculated. Results: A total of 9.43% of children presented with mild to moderate conductive hearing loss (unilateral or bilateral). Diagnostic values varied among the different hearing screening approaches that were evaluated: sensitivities ranged from 60 to 95%, specificities ranged from 44 to 91%, positive predictive values ranged from 15 to 44%, negative predictive values ranged from 95 to 99%, accuracy values ranged from 49 to 88%, and area under curve values ranged from 0.690 to 0.883. Regarding diagnostic values, the highest results were found for the tablet-based screening method and for the series approach. Discussion: Compared with the results obtained by conventional audiometry and considering the diagnostic values of the different hearing screening approaches, the highest diagnostic values were generally obtained using the automated hearing screening method (including 500 Hz). Thus, this application, which was developed for the tablet computer, was shown to be a valuable hearing screening tool for use with schoolchildren. Therefore, we suggest that this hearing screening protocol has the potential to improve asynchronous tele-audiology service delivery.