Zahra Mohammadi
Research Subjects
Zahra Mohammadi has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Abdorreza Sheikh-Mehdi Mesgar
Biomaterials Laboratory Division of Biomedical Engineering Department of Life Science Engineering Faculty of New Sciences and Technologies University of Tehran Tehran Iran
8 shared publications A.A. Ziaei-Moayyed
Institut fur Werk Explosiv-und Betriebsstoffe (WIWEB), 85435 Erding, Germany
3 shared publicationsShaghayegh Kohzadi
Collage of Interdisciplinary Science and Technology., University of Tehran,Biocer and Implant Lab.,Dept. of Life Science Engineering,Tehran,Iran
2 shared publicationsA A Ziaei-Moayyed
1 shared publicationA Sheikh-Mehdi Mesgar
1 shared publication- Alexander Leonidovich Vasiliev
National Research Centre “Kurchatov Institute”, Moscow, Russia
1 shared publication
Latest Publications
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1467-1469
Shape Memory Polymer-Based Scaffolds for Bone Tissue Engineering
In recent years, bone tissue engineering has become a highly promising approach, in which biomaterial scaffolds play a central role by providing structural and biological support for bone regeneration. Among various scaffolding materials, shape-memory polymers (SMPs) have become widely studied because of their ability to recover their original shape from a temporary form when triggered by external stimuli such as heat. This property enables minimally invasive implantation and conformal fitting into irregular bone defects, thereby enhancing osseointegration and tissue ingrowth, making them excellent candidates for bone tissue engineering scaffolds.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1467-1469
Shape Memory Polymer-Based Scaffolds for Bone Tissue Engineering
In recent years, bone tissue engineering has become a highly promising approach, in which biomaterial scaffolds play a central role by providing structural and biological support for bone regeneration. Among various scaffolding materials, shape-memory polymers (SMPs) have become widely studied because of their ability to recover their original shape from a temporary form when triggered by external stimuli such as heat. This property enables minimally invasive implantation and conformal fitting into irregular bone defects, thereby enhancing osseointegration and tissue ingrowth, making them excellent candidates for bone tissue engineering scaffolds.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 26-28
Innovative Biomimetic Skin Repair Strategies Utilizing Barium Titanate
Skin healing is guided by endogenous electric fields, and while external electrical stimulation can help, it's impractical due to bulky equipment. Piezoelectric materials like barium titanate offer a self-powered solution by generating electrical signals from body movements. This review highlights barium titanate-based wound dressings, which are biocompatible, flexible, and efficient. When combined with other materials, they enhance healing by promoting cell activity, tissue regeneration, and providing antibacterial and antiinflammatory effects. These dressings show strong potential for regeneration and repair of chronic and infected wounds without external power sources.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 26-28
Innovative Biomimetic Skin Repair Strategies Utilizing Barium Titanate
Skin healing is guided by endogenous electric fields, and while external electrical stimulation can help, it's impractical due to bulky equipment. Piezoelectric materials like barium titanate offer a self-powered solution by generating electrical signals from body movements. This review highlights barium titanate-based wound dressings, which are biocompatible, flexible, and efficient. When combined with other materials, they enhance healing by promoting cell activity, tissue regeneration, and providing antibacterial and antiinflammatory effects. These dressings show strong potential for regeneration and repair of chronic and infected wounds without external power sources.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-31
Metal-Organic Frameworks: A Promising Class of Materials for Next-Generation Antibacterial Drug Delivery Systems
Bacterial infections that are resistant to drugs represent a significant risk to global public health, highlighting the urgent necessity of developing new antibacterial agents. Metal-Organic Frameworks (MOFs) with their hybrid organicinorganic composition, large specific surface area, adjustable porosity, biodegradability, and biocompatibility have become highly potential nanomaterial frameworks for future antibacterial applications. This review summarizes the latest advances in the application of MOFs as antibacterial drug delivery systems with an emphasis on their multifaceted antibacterial mechanisms based on physical interaction, metal ion release, organic ligand release, antibiotic and therapeutic gas loading, and catalytic activity.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 29-31
Metal-Organic Frameworks: A Promising Class of Materials for Next-Generation Antibacterial Drug Delivery Systems
Bacterial infections that are resistant to drugs represent a significant risk to global public health, highlighting the urgent necessity of developing new antibacterial agents. Metal-Organic Frameworks (MOFs) with their hybrid organicinorganic composition, large specific surface area, adjustable porosity, biodegradability, and biocompatibility have become highly potential nanomaterial frameworks for future antibacterial applications. This review summarizes the latest advances in the application of MOFs as antibacterial drug delivery systems with an emphasis on their multifaceted antibacterial mechanisms based on physical interaction, metal ion release, organic ligand release, antibiotic and therapeutic gas loading, and catalytic activity.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 940-942
GelMA Synthesis and Experimental Challenges
Gelatin methacryloyl (GelMA) is a popular material in tissue engineering. It is made from gelatin and methacrylic anhydride (MAA) and capable of being photocrosslinked. GelMA is widely studied in tissue engineering due to its biocompatibility, tunability, and photocrosslinking capability. This study reviews the standard synthesis protocol and reports experimental challenges observed across three laboratory trials. In the first trial, rapid addition of MAA resulted in uneven reaction kinetics, and only 50% of the freeze-dried Falcon tubes yielded usable GelMA powder. In the second trial, dropwise addition improved reaction uniformity; however, overfilled tubes led to incomplete lyophilization, requiring a second cycle to achieve full drying. Re-drying recovered approximately 80% of the material as stable powder. In the third trial, casting into Petri dishes increased surface area and reduced thickness, enabling complete drying in a single cycle with $\mathbf{> 9 0 \%}$ recovery of dry GelMA. These results highlight the critical influence of reagent addition rate, pH stability, and mass-transfer efficiency on product consistency. The findings demonstrate that careful control of reaction and drying conditions is essential for reproducible GelMA suitable for biomedical applications.- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 940-942
GelMA Synthesis and Experimental Challenges
Gelatin methacryloyl (GelMA) is a popular material in tissue engineering. It is made from gelatin and methacrylic anhydride (MAA) and capable of being photocrosslinked. GelMA is widely studied in tissue engineering due to its biocompatibility, tunability, and photocrosslinking capability. This study reviews the standard synthesis protocol and reports experimental challenges observed across three laboratory trials. In the first trial, rapid addition of MAA resulted in uneven reaction kinetics, and only 50% of the freeze-dried Falcon tubes yielded usable GelMA powder. In the second trial, dropwise addition improved reaction uniformity; however, overfilled tubes led to incomplete lyophilization, requiring a second cycle to achieve full drying. Re-drying recovered approximately 80% of the material as stable powder. In the third trial, casting into Petri dishes increased surface area and reduced thickness, enabling complete drying in a single cycle with $\mathbf{> 9 0 \%}$ recovery of dry GelMA. These results highlight the critical influence of reagent addition rate, pH stability, and mass-transfer efficiency on product consistency. The findings demonstrate that careful control of reaction and drying conditions is essential for reproducible GelMA suitable for biomedical applications.- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 23-25
Conductive Hydrogels in Biomedical Engineering: Current Status and Challenges
Hydrogels are rapidly emerging as a pivotal class of materials across diverse disciplines, largely owing to their exceptional attributes such as biocompatibility, biodegradability, and inherent hydrophilicity. Furthermore, their notable adhesive qualities and impressive elasticity enable seamless integration with myriad surfaces. Within their extensive range of applications, particular interest has been directed towards how these substances influence vital biological phenomena, including cellular migration, neovascularization, and the moderation of inflammatory responses. The present paper is dedicated to elucidating the action mechanisms of conductive hydrogels in promoting wound recovery. Concurrently, it offers an overview of advancements in relevant materials and methodologies, discusses prevailing challenges, and forecasts future directions within this specialized domain.
- 19 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 23-25
Conductive Hydrogels in Biomedical Engineering: Current Status and Challenges
Hydrogels are rapidly emerging as a pivotal class of materials across diverse disciplines, largely owing to their exceptional attributes such as biocompatibility, biodegradability, and inherent hydrophilicity. Furthermore, their notable adhesive qualities and impressive elasticity enable seamless integration with myriad surfaces. Within their extensive range of applications, particular interest has been directed towards how these substances influence vital biological phenomena, including cellular migration, neovascularization, and the moderation of inflammatory responses. The present paper is dedicated to elucidating the action mechanisms of conductive hydrogels in promoting wound recovery. Concurrently, it offers an overview of advancements in relevant materials and methodologies, discusses prevailing challenges, and forecasts future directions within this specialized domain.
- 17 June 2019
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 50 (6) , 747-760
Effect of setting time and artificial saliva on the strength evaluated by different methods of dental silver amalgam: A comparative study
The aim of this study is to evaluate the effect of setting time and artificial saliva on the strength of dental amalgam by diametral compressive strength, Hertzian failure loading testing and compressive strength test methods. Nine dental amalgam products are evaluated using three strength measurements, compressive, diametral, and Hertzian loading testing at early (1 h or 2 h), 24 h and 30 days after setting at 37 °C. The trituted amalgams are used to prepare Hertzian, tapered disc by manual condensation according to the ISO standard procedure (ISO 17988: 2014). The compressive and diametral testing specimens are obtained using the mechanical condensation by two apparatus with different specimen dimensions of height and diameter, 8.0 mm×4.0 mm and 2.0 mm×8.0 mm, respectively. The apparatus and schedule specification for preparing compressive testing specimens are according to ISO 24234: 2015 while dimensions of some parts of diametral testing apparatus were modified and the schedule was optimized to provide sound disc test‐pieces by a one‐shot procedure. The diametral and Hertzian testing specimens are also evaluated after 30 days under dry storage conditions and after aging in the artificial saliva. The artificial saliva was prepared according to ISO17988: 2014 standard specifications. The single diametral or “triple‐cleft” fracture path, and radial cracking are observed in all products for diametral and Hertzian testing methods, respectively. The discriminatory power in early strength tests is in order to Hertzian < diametral < compressive. A significant correlation between diametral and compressive strength value is observed at early setting time. It is found a correlation between diametral and Hertzian strength mean value and variance ratio in immersion test.
- 17 June 2019
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 50 (6) , 747-760
Effect of setting time and artificial saliva on the strength evaluated by different methods of dental silver amalgam: A comparative study
The aim of this study is to evaluate the effect of setting time and artificial saliva on the strength of dental amalgam by diametral compressive strength, Hertzian failure loading testing and compressive strength test methods. Nine dental amalgam products are evaluated using three strength measurements, compressive, diametral, and Hertzian loading testing at early (1 h or 2 h), 24 h and 30 days after setting at 37 °C. The trituted amalgams are used to prepare Hertzian, tapered disc by manual condensation according to the ISO standard procedure (ISO 17988: 2014). The compressive and diametral testing specimens are obtained using the mechanical condensation by two apparatus with different specimen dimensions of height and diameter, 8.0 mm×4.0 mm and 2.0 mm×8.0 mm, respectively. The apparatus and schedule specification for preparing compressive testing specimens are according to ISO 24234: 2015 while dimensions of some parts of diametral testing apparatus were modified and the schedule was optimized to provide sound disc test‐pieces by a one‐shot procedure. The diametral and Hertzian testing specimens are also evaluated after 30 days under dry storage conditions and after aging in the artificial saliva. The artificial saliva was prepared according to ISO17988: 2014 standard specifications. The single diametral or “triple‐cleft” fracture path, and radial cracking are observed in all products for diametral and Hertzian testing methods, respectively. The discriminatory power in early strength tests is in order to Hertzian < diametral < compressive. A significant correlation between diametral and compressive strength value is observed at early setting time. It is found a correlation between diametral and Hertzian strength mean value and variance ratio in immersion test.
- 25 July 2017
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 67 (5) , 267-276
Improvement of mechanical properties and in vitro bioactivity of freeze-dried gelatin/chitosan scaffolds by functionalized carbon nanotubes
Functionalized multiwall carbon nanotubes (f-MWCNTs) were used to reinforce the freeze-dried gelatin (G)/chitosan (Ch) scaffolds for bone graft substitution. Two types of G/Ch scaffolds at a ratio of 2:1 and 3:1 by weight incorporated with 0.025, 0.05, or 0.1 and 0.2 or 0.4 wt% f-MWCNT, respectively, were prepared by freeze drying, and their structure, morphology, and physicochemical and compressive mechanical properties were evaluated. The scaffolds exhibited porous structure with pore size of 80–300 and 120–140 µm for the reinforced scaffolds of G/Ch 2:1 and 3:1, respectively, and porosity 90–93% which slightly decreased with an increase in f-MWCNTs content for both types. Incorporation of f-MWCNTs led to 11- and 9.6-fold increase in modulus, with respect to their pure biopolymer blend scaffolds at a level of 0.05 wt% for G/Ch 2:1 and 0.2 wt% for G/Ch 3:1, respectively. The higher content of f-MWCNTs resulted in loss of mechanical properties due to agglomeration. The highest value of compressive strength and modulus was obtained for G/Ch 2:1 with 0.05 wt% f-MWCNT as 411 kPa and 18.7 MPa, respectively. Improvement of in vitro bioactivity as a result of f-MWCNTs incorporation was proved by formation of a bone-like apatite layer on the surface of scaffolds upon immersion in simulated body fluid. The findings indicate that the f-MWCNT-reinforced gelatin/chitosan scaffolds may be a suitable candidate for bone tissue engineering.
- 25 July 2017
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 67 (5) , 267-276
Improvement of mechanical properties and in vitro bioactivity of freeze-dried gelatin/chitosan scaffolds by functionalized carbon nanotubes
Functionalized multiwall carbon nanotubes (f-MWCNTs) were used to reinforce the freeze-dried gelatin (G)/chitosan (Ch) scaffolds for bone graft substitution. Two types of G/Ch scaffolds at a ratio of 2:1 and 3:1 by weight incorporated with 0.025, 0.05, or 0.1 and 0.2 or 0.4 wt% f-MWCNT, respectively, were prepared by freeze drying, and their structure, morphology, and physicochemical and compressive mechanical properties were evaluated. The scaffolds exhibited porous structure with pore size of 80–300 and 120–140 µm for the reinforced scaffolds of G/Ch 2:1 and 3:1, respectively, and porosity 90–93% which slightly decreased with an increase in f-MWCNTs content for both types. Incorporation of f-MWCNTs led to 11- and 9.6-fold increase in modulus, with respect to their pure biopolymer blend scaffolds at a level of 0.05 wt% for G/Ch 2:1 and 0.2 wt% for G/Ch 3:1, respectively. The higher content of f-MWCNTs resulted in loss of mechanical properties due to agglomeration. The highest value of compressive strength and modulus was obtained for G/Ch 2:1 with 0.05 wt% f-MWCNT as 411 kPa and 18.7 MPa, respectively. Improvement of in vitro bioactivity as a result of f-MWCNTs incorporation was proved by formation of a bone-like apatite layer on the surface of scaffolds upon immersion in simulated body fluid. The findings indicate that the f-MWCNT-reinforced gelatin/chitosan scaffolds may be a suitable candidate for bone tissue engineering.
- 7 June 2017
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 100 (10) , 4719-4733
Bioactive monetite‐containing whisker‐like fibers reinforced chitosan scaffolds
The aim of this work was to develop bioactive chitosan scaffolds reinforced with monetite‐containing whisker‐like fibers. The fibers synthesized by homogeneous precipitation were characterized as monetite/hydroxyapatite short fibers ( MAF s), using XRD , FTIR and SEM . The pure chitosan and MAF s/chitosan composite scaffolds were produced by freeze‐drying, and characterized with respect to porosity, pore size, swelling behavior, compressive strength and modulus, and in vitro bioactivity. The incorporation of MAF s in chitosan matrices led to increase the pore size, according to the evaluation by FE ‐ SEM , and decrease the porosity of composite scaffolds. The swelling ratio decreased as MAF s content of scaffolds increased. The compressive strength and modulus of scaffolds were improved by an increase in MAF s content. The noncross‐linked scaffolds with a chitosan: MAF s weight ratio of 1:1 ( CW 3) showed a porosity of 75.5%, and the strength and modulus of 259 kP a and 2.8 MP a in dry state, respectively. The crosslinking by glutaraldehyde resulted in improved mechanical properties. The strength and modulus of cross‐linked CW 3 scaffolds in wet state reached to 345 kP a and 1.8 MP a, respectively. The in vitro bioactivity of the reinforced scaffolds, evaluated by FE ‐ SEM / EDS , XRD , and ATR ‐ FTIR , was confirmed by the formation of a carbonated apatite layer on their surfaces when they soaked in simulated body fluid ( SBF ). The results of this initial study indicate that the monetite‐containing whisker‐like fibers may be an appropriate reinforcement of chitosan scaffolds.
- 7 June 2017
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 100 (10) , 4719-4733
Bioactive monetite‐containing whisker‐like fibers reinforced chitosan scaffolds
The aim of this work was to develop bioactive chitosan scaffolds reinforced with monetite‐containing whisker‐like fibers. The fibers synthesized by homogeneous precipitation were characterized as monetite/hydroxyapatite short fibers ( MAF s), using XRD , FTIR and SEM . The pure chitosan and MAF s/chitosan composite scaffolds were produced by freeze‐drying, and characterized with respect to porosity, pore size, swelling behavior, compressive strength and modulus, and in vitro bioactivity. The incorporation of MAF s in chitosan matrices led to increase the pore size, according to the evaluation by FE ‐ SEM , and decrease the porosity of composite scaffolds. The swelling ratio decreased as MAF s content of scaffolds increased. The compressive strength and modulus of scaffolds were improved by an increase in MAF s content. The noncross‐linked scaffolds with a chitosan: MAF s weight ratio of 1:1 ( CW 3) showed a porosity of 75.5%, and the strength and modulus of 259 kP a and 2.8 MP a in dry state, respectively. The crosslinking by glutaraldehyde resulted in improved mechanical properties. The strength and modulus of cross‐linked CW 3 scaffolds in wet state reached to 345 kP a and 1.8 MP a, respectively. The in vitro bioactivity of the reinforced scaffolds, evaluated by FE ‐ SEM / EDS , XRD , and ATR ‐ FTIR , was confirmed by the formation of a carbonated apatite layer on their surfaces when they soaked in simulated body fluid ( SBF ). The results of this initial study indicate that the monetite‐containing whisker‐like fibers may be an appropriate reinforcement of chitosan scaffolds.
- 1 August 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 61, 590-599
Reinforcement of freeze-dried chitosan scaffolds with multiphasic calcium phosphate short fibers
- 1 August 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 61, 590-599
Reinforcement of freeze-dried chitosan scaffolds with multiphasic calcium phosphate short fibers
- 1 May 2016
- Published by Elsevier in Ceramics International
- Vol. 42 (6) , 6955-6961
Preparation and characterization of single phase, biphasic and triphasic calcium phosphate whisker-like fibers by homogenous precipitation using urea
- 1 May 2016
- Published by Elsevier in Ceramics International
- Vol. 42 (6) , 6955-6961
Preparation and characterization of single phase, biphasic and triphasic calcium phosphate whisker-like fibers by homogenous precipitation using urea