Alessandra Julie Schuster
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alessandra Julie Schuster has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Fernanda Faot
Federal University of Pelotas
13 shared publications - Amália Machado Bielemann
Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, RS, Brazil
7 shared publications - Otacílio Luiz Chagas Júnior
Federal University of Pelotas
5 shared publications Amália Machado Bielemann
Postdoctoral Research Fellow, Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas (UFPel), Pelotas, Brazil
4 shared publications- Gustavo Giacommelli Nascimento
School of Dentistry, University of Utah, Salt Lake City, UT, USA
4 shared publications - Raissa Micaella Marcello-Machado
Paulista University
4 shared publications
Latest Publications
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 36, e081
Prosthetic complications and quality of life among wearers of mandibular overdenture with the Facility-Equator system
This longitudinal study aimed to assess the performance of the Facility-Equator system as mandibular overdenture (MO) retainers from a prosthetic perspective during 2 years of loading and to investigate the oral health-related quality of life (OHRQoL) and whether prosthetic events can affect the OHRQoL. Twenty-four patients (68.1 ± 7.51 years) reported their OHRQoL through the Geriatric Oral Health Assessment Index (GOHAI) and Oral Health Impact Profile (OHIP-EDENT) questionnaires before MO loading and after 1 and 2 years of usage. Prosthetic occurrences were recorded during this period. Data were analyzed using the Wilcoxon test, Mann-Whitney test, and Spearman correlation coefficients. Of the 127 prosthetic events that occurred in the first year, the most frequent events were prosthesis adjustments (16.5%), dislodgement of the Equator attachment (14.17%), and O-ring replacement (11.8%). Eighty-seven prosthetic events were recorded in the second year, the most frequent events being prosthesis adjustments (27.6%), O-ring replacement (20.7%), and recapturing the female matrix (11.5%). All domains of the GOHAI and OHIP-EDENT questionnaires exhibited a significant difference (p < 0.05) between the baseline and 1- and 2-year evaluations, except in the Social Disability and Psychological Discomfort domains (p > 0.05) of OHIP-EDENT after 1 year. Complications related to prosthetic maintenance, such as fracturing of the prosthesis, Equator dislodgement, prosthesis rebasing, and new overdenture confection, affect the OHRQoL (p < 0.05), primarily the Physical Pain and Discomfort domains, especially in the first year of MO loading.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 36, e081
Open AccessProsthetic complications and quality of life among wearers of mandibular overdenture with the Facility-Equator system
This longitudinal study aimed to assess the performance of the Facility-Equator system as mandibular overdenture (MO) retainers from a prosthetic perspective during 2 years of loading and to investigate the oral health-related quality of life (OHRQoL) and whether prosthetic events can affect the OHRQoL. Twenty-four patients (68.1 ± 7.51 years) reported their OHRQoL through the Geriatric Oral Health Assessment Index (GOHAI) and Oral Health Impact Profile (OHIP-EDENT) questionnaires before MO loading and after 1 and 2 years of usage. Prosthetic occurrences were recorded during this period. Data were analyzed using the Wilcoxon test, Mann-Whitney test, and Spearman correlation coefficients. Of the 127 prosthetic events that occurred in the first year, the most frequent events were prosthesis adjustments (16.5%), dislodgement of the Equator attachment (14.17%), and O-ring replacement (11.8%). Eighty-seven prosthetic events were recorded in the second year, the most frequent events being prosthesis adjustments (27.6%), O-ring replacement (20.7%), and recapturing the female matrix (11.5%). All domains of the GOHAI and OHIP-EDENT questionnaires exhibited a significant difference (p < 0.05) between the baseline and 1- and 2-year evaluations, except in the Social Disability and Psychological Discomfort domains (p > 0.05) of OHIP-EDENT after 1 year. Complications related to prosthetic maintenance, such as fracturing of the prosthesis, Equator dislodgement, prosthesis rebasing, and new overdenture confection, affect the OHRQoL (p < 0.05), primarily the Physical Pain and Discomfort domains, especially in the first year of MO loading.
- 8 August 2020
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 47 (10) , 1278-1286
Masticatory function and oral health‐related quality of life of patients with atrophic and non‐atrophic mandibles using implant‐retained mandibular overdentures: 3‐year results of a prospective clinical study
Background: Long‐term changes in masticatory function, oral health‐related quality of life (OHRQoL) and prosthetic complications in implant‐retained mandibular overdenture (IMO) wearers as a function of bone atrophy require detailed investigations.Objective: Investigating the evolution of masticatory function, OHRQoL and prosthetic occurrences of IMO wearers according to mandibular bone atrophy over 3 years of usage.Methods: This study evaluated 26 IMO wearers after 2 and 3 years of IMO loading categorised according to mandibular resorption degree into atrophic mandible (AM) and a non‐atrophic mandible (NAM) group. Masticatory function was assessed by the Masticatory Performance (MP) and Swallowing Threshold (ST) tests; OHRQoL and satisfaction via the Dental Impact on Daily Living (DIDL) questionnaire; and the prosthetic maintenance requirements and complications were monitored.Results: After the second year, the AM Group performed 32% more cycles (P = .047) than the NAM Group during the ST test. The DIDL questionnaire showed no significant difference for all domains, except for a moderate effect size in the General Performance domain after the third year. AM Group had more prosthetic occurrences (n = 109) than NAM Group (n = 60) in the first year, mainly due to Equator attachment dislodgment. During the third year, NAM Group presented a greater number of events (n = 45) than AM Group (n = 21) due to the greater number of O‐ring exchanges.Conclusion: Masticatory function and OHRQoL are not related to mandibular bone atrophy until 3 years after IMO rehabilitation. The prosthetic complications profile differs between groups, mainly in the first year.
- 8 August 2020
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 47 (10) , 1278-1286
Masticatory function and oral health‐related quality of life of patients with atrophic and non‐atrophic mandibles using implant‐retained mandibular overdentures: 3‐year results of a prospective clinical study
Background: Long‐term changes in masticatory function, oral health‐related quality of life (OHRQoL) and prosthetic complications in implant‐retained mandibular overdenture (IMO) wearers as a function of bone atrophy require detailed investigations.Objective: Investigating the evolution of masticatory function, OHRQoL and prosthetic occurrences of IMO wearers according to mandibular bone atrophy over 3 years of usage.Methods: This study evaluated 26 IMO wearers after 2 and 3 years of IMO loading categorised according to mandibular resorption degree into atrophic mandible (AM) and a non‐atrophic mandible (NAM) group. Masticatory function was assessed by the Masticatory Performance (MP) and Swallowing Threshold (ST) tests; OHRQoL and satisfaction via the Dental Impact on Daily Living (DIDL) questionnaire; and the prosthetic maintenance requirements and complications were monitored.Results: After the second year, the AM Group performed 32% more cycles (P = .047) than the NAM Group during the ST test. The DIDL questionnaire showed no significant difference for all domains, except for a moderate effect size in the General Performance domain after the third year. AM Group had more prosthetic occurrences (n = 109) than NAM Group (n = 60) in the first year, mainly due to Equator attachment dislodgment. During the third year, NAM Group presented a greater number of events (n = 45) than AM Group (n = 21) due to the greater number of O‐ring exchanges.Conclusion: Masticatory function and OHRQoL are not related to mandibular bone atrophy until 3 years after IMO rehabilitation. The prosthetic complications profile differs between groups, mainly in the first year.
- Open Access
- 1 August 2020
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 31 (4) , 399-403
Evaluation of Bite Force and Masticatory Performance: Complete Denture vs Mandibular Overdenture Users
This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed bilaterally with an occlusal force device. During the MP test, patients were asked to chew Optocal particles for 40 cycles. The Shapiro Wilk test was employed to verify the normality of the data, the student t test to identify differences between groups, and Pearson’s correlation to investigate interrelationships between variables. A multiple linear regression was subsequently performed via the stepwise method. P values ≤0.05 were considered statistically significant. Unlike IMO users, CCD users presented a significant difference (25.6%) in BF between the dominant and non-dominant chewing side (p=0.04). IMO users presented significantly higher BF (p=0.01) without presenting a dominant side (p=0.38), and also performed significantly better for the following MP parameters: MPX50 values decreased by 27.25% in IMO users (p=0.01), MPB decreased by 48.38% (p=0.01), and ME 5.6 decreased by 53.25% (p=0.02), while ME2.8 increased by 151.57% (p=0.01). The BF and MPX50 in the IMO wearers group were negatively correlated (-0.57; p=0.05); this correlation coefficient was the only parameter included in the multivariate regression model. IMO users have higher BF and better masticatory performance than CCD users, especially in terms of chewed particles size reduction. MP is correlated with a higher BF in IMO users through better particle trituration.
- 1 August 2020
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 31 (4) , 399-403
Open AccessEvaluation of Bite Force and Masticatory Performance: Complete Denture vs Mandibular Overdenture Users
This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed bilaterally with an occlusal force device. During the MP test, patients were asked to chew Optocal particles for 40 cycles. The Shapiro Wilk test was employed to verify the normality of the data, the student t test to identify differences between groups, and Pearson’s correlation to investigate interrelationships between variables. A multiple linear regression was subsequently performed via the stepwise method. P values ≤0.05 were considered statistically significant. Unlike IMO users, CCD users presented a significant difference (25.6%) in BF between the dominant and non-dominant chewing side (p=0.04). IMO users presented significantly higher BF (p=0.01) without presenting a dominant side (p=0.38), and also performed significantly better for the following MP parameters: MPX50 values decreased by 27.25% in IMO users (p=0.01), MPB decreased by 48.38% (p=0.01), and ME 5.6 decreased by 53.25% (p=0.02), while ME2.8 increased by 151.57% (p=0.01). The BF and MPX50 in the IMO wearers group were negatively correlated (-0.57; p=0.05); this correlation coefficient was the only parameter included in the multivariate regression model. IMO users have higher BF and better masticatory performance than CCD users, especially in terms of chewed particles size reduction. MP is correlated with a higher BF in IMO users through better particle trituration.
- Open Access
- 1 January 2020
- Published by Wiley in Case Reports in Dentistry
- Vol. 2020 (1)
Clinical Versatility of the Facility‐Equator Implant System as Mandibular Overdenture Retainers
The use of mandibular overdentures (MO) for the rehabilitation of totally edentulous individuals with limited bone availability is widespread and has proven clinical success. Narrow diameter implants (NDI) are available on the market as MO retainers to solve problems related to limited bone availability and bone thickness, providing a low‐cost, minimally invasive treatment option. This technique evolved over the years, and changes frequently involved the number of implants used as MO retainers, as the adoption of a smaller number of implants can generate biomechanical disadvantages, contributing to the increased stress in peri‐implant tissues, which may accelerate marginal bone loss (MBL), in addition to reducing masticatory capacity and satisfaction with rehabilitation. Some studies pointed out that the use of 3 or more implants as MO retainers improves the biomechanics. Thus, the objective of this study was to report 3 different clinical cases where 3 or more NDI were adopted to retain mandibular overdentures in association with diverse loading protocols: (i) 3 implants adopting conventional loading, (ii) 4 implants using progressive loading, and (iii) 4 implants with hybrid loading. The case with 4 implants and progressive loading showed a slight worsening of masticatory function at 1 year, in addition to a more pronounced MBL compared to other cases, but with improvements in satisfaction and oral health‐related quality of life. Thus, NDI can be used as MO retainers with predictability and clinical success, using different numbers of implants and loading protocols.
- 1 January 2020
- Published by Wiley in Case Reports in Dentistry
- Vol. 2020 (1)
Open AccessClinical Versatility of the Facility‐Equator Implant System as Mandibular Overdenture Retainers
The use of mandibular overdentures (MO) for the rehabilitation of totally edentulous individuals with limited bone availability is widespread and has proven clinical success. Narrow diameter implants (NDI) are available on the market as MO retainers to solve problems related to limited bone availability and bone thickness, providing a low‐cost, minimally invasive treatment option. This technique evolved over the years, and changes frequently involved the number of implants used as MO retainers, as the adoption of a smaller number of implants can generate biomechanical disadvantages, contributing to the increased stress in peri‐implant tissues, which may accelerate marginal bone loss (MBL), in addition to reducing masticatory capacity and satisfaction with rehabilitation. Some studies pointed out that the use of 3 or more implants as MO retainers improves the biomechanics. Thus, the objective of this study was to report 3 different clinical cases where 3 or more NDI were adopted to retain mandibular overdentures in association with diverse loading protocols: (i) 3 implants adopting conventional loading, (ii) 4 implants using progressive loading, and (iii) 4 implants with hybrid loading. The case with 4 implants and progressive loading showed a slight worsening of masticatory function at 1 year, in addition to a more pronounced MBL compared to other cases, but with improvements in satisfaction and oral health‐related quality of life. Thus, NDI can be used as MO retainers with predictability and clinical success, using different numbers of implants and loading protocols.
- 1 November 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 122 (5) , 450-458
Influence of facial patterns on the masticatory function and quality of life of completely edentulous patients during the transition to implant-retained mandibular overdentures
- 1 November 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 122 (5) , 450-458
Influence of facial patterns on the masticatory function and quality of life of completely edentulous patients during the transition to implant-retained mandibular overdentures
- 1 March 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (3) , 432-439
Is predicting masticatory function based on mandibular bone atrophy as defined by clinical and radiographic parameters possible? A clinical study
- 1 March 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (3) , 432-439
Is predicting masticatory function based on mandibular bone atrophy as defined by clinical and radiographic parameters possible? A clinical study
- 19 November 2018
- Published by Wiley in Journal of Periodontal Research
- Vol. 54 (3) , 241-250
Healing differences in narrow diameter implants submitted to immediate and conventional loading in mandibular overdentures: A randomized clinical trial
Background: Biological responses to different loading protocols during the bone healing phase in subjects with long time since edentulism, rehabilitated with narrow diameter implants (NDIs) to retain mandibular overdentures (MOs), are still unavailable.Objective: This randomized clinical trial compared the peri‐implant health, implant stability, and concentrations of pro‐ and anti‐inflammatory cytokines in the peri‐implant crevicular fluid (PICF) in mandibular edentulous patients under conventional (CL) and immediate loading (IML) during healing.Methodology: Twenty totally edentulous patients received two NDIs (2.9 × 10 mm, Facility NeoPoros) placed in mandible anterior region and were randomly assigned to two loading protocols: CL (n = 10) and IML (n = 10). The following clinical outcomes were evaluated 1, 2, 4, 8, and 12 weeks after surgery: (a) peri‐implant tissue health (gingival index‐GI, plaque index‐PI, calculus‐presence CP, probing depth‐PD, and bleeding on probing‐BOP); (b) implant stability quotient (ISQ); and (c) IL‐1β, IL‐6, IL‐10, and TNF‐α levels in the PICF analyzed by ELISA.Results: The CL group showed significantly higher CP scores at weeks 8 and 12. The IML group showed significantly higher GI from the first week onwards. The IML group presented significantly lower PD at all follow‐up times, and higher BOP rates than CL at week 12. The ISQ values of the CL group were higher than those of the IML group, except at week 4. The IML group released significantly more TNF‐α between weeks 1 and 4 and more IL‐1β during week 4‐12, while releasing less IL‐6 until week 8, mainly at week 2 (−47.6%). The release of IL‐10 was similar for both groups and increased progressively over time. At week 12, the IML group released 45.74% more IL‐10 than the CL group. The survival rates were 95% and 90% for CL and IML, respectively.Conclusion: The IML group presented more favorable PD at all evaluation times; the differences between the other clinical parameters were less systematic. The implant stability and the inflammatory marker concentrations were more stable in the CL group.
- 19 November 2018
- Published by Wiley in Journal of Periodontal Research
- Vol. 54 (3) , 241-250
Healing differences in narrow diameter implants submitted to immediate and conventional loading in mandibular overdentures: A randomized clinical trial
Background: Biological responses to different loading protocols during the bone healing phase in subjects with long time since edentulism, rehabilitated with narrow diameter implants (NDIs) to retain mandibular overdentures (MOs), are still unavailable.Objective: This randomized clinical trial compared the peri‐implant health, implant stability, and concentrations of pro‐ and anti‐inflammatory cytokines in the peri‐implant crevicular fluid (PICF) in mandibular edentulous patients under conventional (CL) and immediate loading (IML) during healing.Methodology: Twenty totally edentulous patients received two NDIs (2.9 × 10 mm, Facility NeoPoros) placed in mandible anterior region and were randomly assigned to two loading protocols: CL (n = 10) and IML (n = 10). The following clinical outcomes were evaluated 1, 2, 4, 8, and 12 weeks after surgery: (a) peri‐implant tissue health (gingival index‐GI, plaque index‐PI, calculus‐presence CP, probing depth‐PD, and bleeding on probing‐BOP); (b) implant stability quotient (ISQ); and (c) IL‐1β, IL‐6, IL‐10, and TNF‐α levels in the PICF analyzed by ELISA.Results: The CL group showed significantly higher CP scores at weeks 8 and 12. The IML group showed significantly higher GI from the first week onwards. The IML group presented significantly lower PD at all follow‐up times, and higher BOP rates than CL at week 12. The ISQ values of the CL group were higher than those of the IML group, except at week 4. The IML group released significantly more TNF‐α between weeks 1 and 4 and more IL‐1β during week 4‐12, while releasing less IL‐6 until week 8, mainly at week 2 (−47.6%). The release of IL‐10 was similar for both groups and increased progressively over time. At week 12, the IML group released 45.74% more IL‐10 than the CL group. The survival rates were 95% and 90% for CL and IML, respectively.Conclusion: The IML group presented more favorable PD at all evaluation times; the differences between the other clinical parameters were less systematic. The implant stability and the inflammatory marker concentrations were more stable in the CL group.
- Open Access
- 1 October 2018
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 62 (4) , 479-484
Masticatory function of conventional complete denture wearers changing to 2-implant retained mandibular overdentures: clinical factor influences after 1 year of function
Evaluate how clinical factors related to conventional complete denture (CCD) wearers, can influence masticatory function (MF) of totally edentulous patients before and after one-year transitioning to implant-retained mandibular overdentures (IMO). Forty patients using CCD were rehabilitated with IMO and their MF was evaluated by: (i) ST_X50: theoretical aperture through which 50% of the weight of the particles would pass; (ii) STB: distribution homogeneity of the crushed particles. The clinical parameters analyzed were: atrophy, retention, stability, facial type, anteroposterior skeletal discrepancy, and type of loading. The statistical association was tested through crude and adjusted logistic regression. IMO promoted improvements in the MF, irrespective of the clinical parameters. CCD wearers with poor retention had 86% less chance of achieving a good ST_X50. STB was associated with stability, facial type, and anteroposterior discrepancy. Subjects with poor mandibular CCD stability had a 76% lower chance of achieving a good test food homogenization, whereas brachyfacial individuals were 1.3 times more likely to have a good STB. Class II patients had an 89% lower chance of having a good homogenization of the particles as CCD users and after transition to IMO. CCD users with poor retention achieved an inferior ST_X50. The STB performance can be compromised by poor stability or Class II characteristics, while brachyfacial individuals achieve better homogenezation of the food bolus. Although the transition to IMO improved the masticatory function, the anteroposterior discrepancy still maintained an association with STB, as Class II individuals still presented difficulties homogenizing food.
- 1 October 2018
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 62 (4) , 479-484
Open AccessMasticatory function of conventional complete denture wearers changing to 2-implant retained mandibular overdentures: clinical factor influences after 1 year of function
Evaluate how clinical factors related to conventional complete denture (CCD) wearers, can influence masticatory function (MF) of totally edentulous patients before and after one-year transitioning to implant-retained mandibular overdentures (IMO). Forty patients using CCD were rehabilitated with IMO and their MF was evaluated by: (i) ST_X50: theoretical aperture through which 50% of the weight of the particles would pass; (ii) STB: distribution homogeneity of the crushed particles. The clinical parameters analyzed were: atrophy, retention, stability, facial type, anteroposterior skeletal discrepancy, and type of loading. The statistical association was tested through crude and adjusted logistic regression. IMO promoted improvements in the MF, irrespective of the clinical parameters. CCD wearers with poor retention had 86% less chance of achieving a good ST_X50. STB was associated with stability, facial type, and anteroposterior discrepancy. Subjects with poor mandibular CCD stability had a 76% lower chance of achieving a good test food homogenization, whereas brachyfacial individuals were 1.3 times more likely to have a good STB. Class II patients had an 89% lower chance of having a good homogenization of the particles as CCD users and after transition to IMO. CCD users with poor retention achieved an inferior ST_X50. The STB performance can be compromised by poor stability or Class II characteristics, while brachyfacial individuals achieve better homogenezation of the food bolus. Although the transition to IMO improved the masticatory function, the anteroposterior discrepancy still maintained an association with STB, as Class II individuals still presented difficulties homogenizing food.
- 26 March 2018
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (4) , 483-492
One‐year clinical outcomes of locking taper Equator attachments retaining mandibular overdentures to narrow diameter implants
Background: Narrow diameter implants (NDI) are recommended to retain mandibular overdentures (MOs) in cases of limited bone thickness. It is necessary to evaluate the clinical behavior of NDI as MO retainers connected to a new screwless locking taper abutments, their predictability and maintenance problems.Objectives: To evaluate the peri‐implant tissue behavior around NDI and the performance of locking taper stud abutments as MO retainers.Methodology: Thirty patients (average age of 67.5 years) received 2 NDI implants (2.9 × 10 mm) loaded after 12 weeks using Equator stud attachments. The plaque index (PI), calculus index (CI), gingival index (GI), probing depth (PD), bleeding on probing (BOP), and implant stability quotient (ISQ) were monitored during osseointegration at 0, 4, 8, and 12 weeks and postloading at 24, 48, and 60 weeks. The marginal bone level (MBL) and bone level changes (BLC) were determined at baseline and 60 weeks.Results: The cumulative success rate was 83.3%. The PI oscillated in the first 24 weeks and decreased from 48 weeks onward, while the CI score showed significantly higher values at week 8 (22%). The GI also peaked at week 8 (18.6%) and decreased from week 12 onward. The PD decreased gradually over time, but no significant differences were found between weeks 8 and 12. The ISQ decreased significantly between 0 and 12 weeks. After MO loading, the ISQ values increased linearly and significantly between 12 and 24, 24 and 48, and 48 and 60 weeks and reached values similar to the primary stability after 60 weeks [56.1(42.0‐65.3)]. No significant MBL was observed at 60 weeks, with an average BLC of −0.06 ± 0.64 mm.Conclusion: NDI connected to locking taper Equator attachments showed a stable clinical behavior as an MO retainer for edentulous patients with clinical mandibular atrophy.
- 26 March 2018
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (4) , 483-492
One‐year clinical outcomes of locking taper Equator attachments retaining mandibular overdentures to narrow diameter implants
Background: Narrow diameter implants (NDI) are recommended to retain mandibular overdentures (MOs) in cases of limited bone thickness. It is necessary to evaluate the clinical behavior of NDI as MO retainers connected to a new screwless locking taper abutments, their predictability and maintenance problems.Objectives: To evaluate the peri‐implant tissue behavior around NDI and the performance of locking taper stud abutments as MO retainers.Methodology: Thirty patients (average age of 67.5 years) received 2 NDI implants (2.9 × 10 mm) loaded after 12 weeks using Equator stud attachments. The plaque index (PI), calculus index (CI), gingival index (GI), probing depth (PD), bleeding on probing (BOP), and implant stability quotient (ISQ) were monitored during osseointegration at 0, 4, 8, and 12 weeks and postloading at 24, 48, and 60 weeks. The marginal bone level (MBL) and bone level changes (BLC) were determined at baseline and 60 weeks.Results: The cumulative success rate was 83.3%. The PI oscillated in the first 24 weeks and decreased from 48 weeks onward, while the CI score showed significantly higher values at week 8 (22%). The GI also peaked at week 8 (18.6%) and decreased from week 12 onward. The PD decreased gradually over time, but no significant differences were found between weeks 8 and 12. The ISQ decreased significantly between 0 and 12 weeks. After MO loading, the ISQ values increased linearly and significantly between 12 and 24, 24 and 48, and 48 and 60 weeks and reached values similar to the primary stability after 60 weeks [56.1(42.0‐65.3)]. No significant MBL was observed at 60 weeks, with an average BLC of −0.06 ± 0.64 mm.Conclusion: NDI connected to locking taper Equator attachments showed a stable clinical behavior as an MO retainer for edentulous patients with clinical mandibular atrophy.
- 7 December 2017
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29 (2) , 215-226
How fast can treatment with overdentures improve the masticatory function and OHRQoL of atrophic edentulous patients? A 1‐year longitudinal clinical study
Objectives: The aim of this prospective clinical study was to evaluate the masticatory function (MF) and subjective perception of patients with poor denture‐bearing tissue in relation to change and the time required to identify an improvement in these parameters after rehabilitation with mandibular overdentures (MO) by two narrow‐diameter two‐piece implants.Material and methods: Twenty‐three edentulous patients were selected for MO installation. The masticatory function (MF) was evaluated with the masticatory performance (MP) and swallowing threshold (ST) tests. In the MP test, each volunteer was instructed to masticate a portion of Optocal (standardized artificial test food) for 40 masticatory cycles. During the swallowing threshold test, the patients were instructed to chew a new portion of Optocal cubes until they felt the desire to swallow. The MF tests were performed while complete denture (CD) wearers (baseline) and 1, 3, 6, and 12 months after MO loading. In addition, the subjective perception was assessed through the questionnaires Dental Impact on Daily Living (DIDL), Geriatric Oral Health Assessment Index (GOHAI), and Oral Health Impact Profile in Edentulous (OHIP‐ EDENT) at the baseline and 3, 6, and 12 months after MO loading.Results: A significant improvement in masticatory function (p < .05) was observed already in the first month of loading. Three months after MO loading, a significant improvement (p < .05) was found in the subjective perception of patients. The effect size indicates that the MO had the greatest impact on the domains related to function and comfort of all questionnaires and in relation to psychosocial domain of the GOHAI. The level of patient satisfaction increased significantly after the MO loading and reached >90% satisfied patients at 12 months.Conclusion: The MO improved both the MF of the patient and their oral health‐related quality of life and satisfaction regarding the prosthesis in a short time period.
- 7 December 2017
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29 (2) , 215-226
How fast can treatment with overdentures improve the masticatory function and OHRQoL of atrophic edentulous patients? A 1‐year longitudinal clinical study
Objectives: The aim of this prospective clinical study was to evaluate the masticatory function (MF) and subjective perception of patients with poor denture‐bearing tissue in relation to change and the time required to identify an improvement in these parameters after rehabilitation with mandibular overdentures (MO) by two narrow‐diameter two‐piece implants.Material and methods: Twenty‐three edentulous patients were selected for MO installation. The masticatory function (MF) was evaluated with the masticatory performance (MP) and swallowing threshold (ST) tests. In the MP test, each volunteer was instructed to masticate a portion of Optocal (standardized artificial test food) for 40 masticatory cycles. During the swallowing threshold test, the patients were instructed to chew a new portion of Optocal cubes until they felt the desire to swallow. The MF tests were performed while complete denture (CD) wearers (baseline) and 1, 3, 6, and 12 months after MO loading. In addition, the subjective perception was assessed through the questionnaires Dental Impact on Daily Living (DIDL), Geriatric Oral Health Assessment Index (GOHAI), and Oral Health Impact Profile in Edentulous (OHIP‐ EDENT) at the baseline and 3, 6, and 12 months after MO loading.Results: A significant improvement in masticatory function (p < .05) was observed already in the first month of loading. Three months after MO loading, a significant improvement (p < .05) was found in the subjective perception of patients. The effect size indicates that the MO had the greatest impact on the domains related to function and comfort of all questionnaires and in relation to psychosocial domain of the GOHAI. The level of patient satisfaction increased significantly after the MO loading and reached >90% satisfied patients at 12 months.Conclusion: The MO improved both the MF of the patient and their oral health‐related quality of life and satisfaction regarding the prosthesis in a short time period.