Lucas Rafael Do Nascimento
Lucas Rafael Do Nascimento has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Ricardo Rüther
Fotovoltaica/UFSC, Universidade Federal de Santa Catarina, Florianópolis 88056-000, Brazil
6 shared publications - Marília Braga
Fotovoltaica/UFSC, Universidade Federal de Santa Catarina, Florianópolis 88056-000, Brazil
5 shared publications Rafael Antunes Campos
3 shared publicationsRicardo Ruther
Universidade Federal de Santa Catarina, Florianópolis-SC, Brazil
3 shared publicationsRicardo Rüther
Energy Research Laboratory Fotovoltaica/UFSC
3 shared publications- Aline Kirsten Vidal de Oliveira
Solar Energy Research Laboratory Fotovoltaica, Universidade Federal de Santa Catarina (UFSC), Florianópolis 88054-700, Brazil
2 shared publications
Latest Publications
- Open Access
- 6 February 2026
- Published by EDP Sciences in EPJ Photovoltaics
- Vol. 17, 7
Strategy for simple, on-site failure analysis: investigating bubbles and burn marks in backsheets of PV modules
We present a practical, field-deployable workflow for the identification and analysis of localized polymer degradation in photovoltaic modules, observed as bubbles and burn marks in three multi-MWp power plants in Brazil and Germany. The approach combines high-throughput screening—visual inspection, infrared thermography, ultraviolet fluorescence imaging, and serial-number mapping—with selective in-depth analyses of representative modules using electroluminescence, current–voltage measurements, and near-infrared absorption spectroscopy. The workflow enables efficient detection of anomalies across large installations, while confirmatory tests validate root causes on a limited subset. Defects occurred in about 3–4% of inspected modules and were concentrated in the upper and lower cell rows. Although all sites experienced similar partial shading, anomalies appeared only in PET-based backsheets with PVDF or PVF outer layers, highlighting material-dependent susceptibility. No immediate electrical or safety impact was found, but continued monitoring is advised to mitigate future reliability risks. The presented methodology offers a scalable, drone-compatible framework for early-stage field detection of polymer degradation.
- 6 February 2026
- Published by EDP Sciences in EPJ Photovoltaics
- Vol. 17, 7
Open AccessStrategy for simple, on-site failure analysis: investigating bubbles and burn marks in backsheets of PV modules
We present a practical, field-deployable workflow for the identification and analysis of localized polymer degradation in photovoltaic modules, observed as bubbles and burn marks in three multi-MWp power plants in Brazil and Germany. The approach combines high-throughput screening—visual inspection, infrared thermography, ultraviolet fluorescence imaging, and serial-number mapping—with selective in-depth analyses of representative modules using electroluminescence, current–voltage measurements, and near-infrared absorption spectroscopy. The workflow enables efficient detection of anomalies across large installations, while confirmatory tests validate root causes on a limited subset. Defects occurred in about 3–4% of inspected modules and were concentrated in the upper and lower cell rows. Although all sites experienced similar partial shading, anomalies appeared only in PET-based backsheets with PVDF or PVF outer layers, highlighting material-dependent susceptibility. No immediate electrical or safety impact was found, but continued monitoring is advised to mitigate future reliability risks. The presented methodology offers a scalable, drone-compatible framework for early-stage field detection of polymer degradation.
- Open Access
- 8 November 2021
- Published by Associação Brasileira de Energia Solar in Revista Brasileira de Energia Solar
- Vol. 12 (1) , 59-68
MODELAGEM ESPECTRAL E AVALIAÇÃO DOS IMPACTOS ESPECTRAIS NO DESEMPENHO DAS TECNOLOGIAS FOTOVOLTAICAS DE MC-SI E CDTE EM CLIMAS QUENTES E ENSOLARADOS
Este artigo apresenta uma análise dos impactos espectrais nas tecnologias mc-Si e CdTe em duas regiões distintas do Brasil: Florianópolis-SC (27 ° S, 48 ° W) no Sul e Assu-RN (5 ° S, 37 ° W) no Nordeste. À medida que usinas fotovoltaicas de grande porte estão sendo implantadas progressivamente no nordeste brasileiro, surge a necessidade de avaliação dos efeitos dos espectros locais no desempenho de diferentes tecnologias fotovoltaicas. Considerando o alto custo de equipamentos de medição espectral adequados, este artigo propõe uma nova abordagem para a estimativa de impactos espectrais sem a necessidade de medições in loco. A metodologia proposta consiste no uso de dados de satélite adquiridos da plataforma Giovanni da NASA como entradas para o modelo de espectro SMARTS 2.9.5. Os resultados dos espectros medidos mostraram que, para os dois locais, a tecnologia de CdTe apresenta ganhos espectrais significativos: até 10% para Assu-RN (Nordeste) e 2% para Florianópolis-SC (Sul). Uma variação sazonal também pode ser observada para ambos os locais, com ganhos espectrais mais baixos para CdTe - e mais altos para mc-Si - próximos ao solstício de inverno do Hemisfério Sul, devido a valores mais elevados de massa de ar e menor teor de água precipitável na atmosfera. O método proposto usando dados de Giovanni e modelagem de espectros SMARTS produziu espectros muito semelhantes aos medidos para dias de céu limpo em ambos os locais, produzindo bons resultados para o cálculo de fatores espectrais para ambas as tecnologias avaliadas. Nos dias com maior fração difusa, os resultados não foram tão satisfatórios, de acordo com já era esperado.
- 8 November 2021
- Published by Associação Brasileira de Energia Solar in Revista Brasileira de Energia Solar
- Vol. 12 (1) , 59-68
Open AccessMODELAGEM ESPECTRAL E AVALIAÇÃO DOS IMPACTOS ESPECTRAIS NO DESEMPENHO DAS TECNOLOGIAS FOTOVOLTAICAS DE MC-SI E CDTE EM CLIMAS QUENTES E ENSOLARADOS
Este artigo apresenta uma análise dos impactos espectrais nas tecnologias mc-Si e CdTe em duas regiões distintas do Brasil: Florianópolis-SC (27 ° S, 48 ° W) no Sul e Assu-RN (5 ° S, 37 ° W) no Nordeste. À medida que usinas fotovoltaicas de grande porte estão sendo implantadas progressivamente no nordeste brasileiro, surge a necessidade de avaliação dos efeitos dos espectros locais no desempenho de diferentes tecnologias fotovoltaicas. Considerando o alto custo de equipamentos de medição espectral adequados, este artigo propõe uma nova abordagem para a estimativa de impactos espectrais sem a necessidade de medições in loco. A metodologia proposta consiste no uso de dados de satélite adquiridos da plataforma Giovanni da NASA como entradas para o modelo de espectro SMARTS 2.9.5. Os resultados dos espectros medidos mostraram que, para os dois locais, a tecnologia de CdTe apresenta ganhos espectrais significativos: até 10% para Assu-RN (Nordeste) e 2% para Florianópolis-SC (Sul). Uma variação sazonal também pode ser observada para ambos os locais, com ganhos espectrais mais baixos para CdTe - e mais altos para mc-Si - próximos ao solstício de inverno do Hemisfério Sul, devido a valores mais elevados de massa de ar e menor teor de água precipitável na atmosfera. O método proposto usando dados de Giovanni e modelagem de espectros SMARTS produziu espectros muito semelhantes aos medidos para dias de céu limpo em ambos os locais, produzindo bons resultados para o cálculo de fatores espectrais para ambas as tecnologias avaliadas. Nos dias com maior fração difusa, os resultados não foram tão satisfatórios, de acordo com já era esperado.
- 1 February 2020
- Published by Elsevier in Renewable Energy
- Vol. 146, 1070-1082
Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
- 1 February 2020
- Published by Elsevier in Renewable Energy
- Vol. 146, 1070-1082
Performance assessment of solar photovoltaic technologies under different climatic conditions in Brazil
- 1 August 2019
- Published by Elsevier in Solar Energy
- Vol. 188, 976-988
Spectral modeling and spectral impacts on the performance of mc-Si and new generation CdTe photovoltaics in warm and sunny climates
- 1 August 2019
- Published by Elsevier in Solar Energy
- Vol. 188, 976-988
Spectral modeling and spectral impacts on the performance of mc-Si and new generation CdTe photovoltaics in warm and sunny climates
- 1 July 2019
- Published by Elsevier in Solar Energy
- Vol. 186, 370-381
Extreme solar overirradiance events: Occurrence and impacts on utility-scale photovoltaic power plants in Brazil
- 1 July 2019
- Published by Elsevier in Solar Energy
- Vol. 186, 370-381
Extreme solar overirradiance events: Occurrence and impacts on utility-scale photovoltaic power plants in Brazil
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0684-0689
Aerial Infrared Thermography of a Utility-Scale PV Plant After a Meteorological Tsunami in Brazil
Aerial Infrared Thermography (aIRT) is a nondestructive and cost-effective method for detecting faults in largescale PV plants. In this paper, a 1 MW multi-crystalline PV plantblock that was hit by a meteorological tsunami in Brazil in 2016, is inspected systematically using the aIRT method. The main objective was to validate this inspection technique for commercial application. Various failures like hotspots, bypassed substrings, short-circuited and disconnected PV strings were detected at the PV plant using aIRT inspection in less than one hour. The results have proven that this semi-autonomous method is very fast, reliable and effective for large scale PV plants.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0684-0689
Aerial Infrared Thermography of a Utility-Scale PV Plant After a Meteorological Tsunami in Brazil
Aerial Infrared Thermography (aIRT) is a nondestructive and cost-effective method for detecting faults in largescale PV plants. In this paper, a 1 MW multi-crystalline PV plantblock that was hit by a meteorological tsunami in Brazil in 2016, is inspected systematically using the aIRT method. The main objective was to validate this inspection technique for commercial application. Various failures like hotspots, bypassed substrings, short-circuited and disconnected PV strings were detected at the PV plant using aIRT inspection in less than one hour. The results have proven that this semi-autonomous method is very fast, reliable and effective for large scale PV plants.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1173-1178
Performance Assessment of PV Technologies and Complementarity of Utility-Scale PV and Wind Power Plants in Brazil
Utility-scale PV power plants are finally gaining momentum in Brazil, and most of the installed and planned generators make use of the excellent solar resources available in the Brazilian Northeast (annual irradiation levels in the 2000 to 2300 kWh/m2 range). These same sites also enjoy the best wind resources in the country, allowing both solar and wind power plants to share not only the same land, but also the same electrical infrastructure in many cases. In this paper we present results on the performance assessment of five commercially-available PV technologies installed at an evaluation site next to a 95 MW wind farm. We discuss PV performance issues related to each of the PV technologies and the complementary nature of the solar and wind resource availability at the site.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1173-1178
Performance Assessment of PV Technologies and Complementarity of Utility-Scale PV and Wind Power Plants in Brazil
Utility-scale PV power plants are finally gaining momentum in Brazil, and most of the installed and planned generators make use of the excellent solar resources available in the Brazilian Northeast (annual irradiation levels in the 2000 to 2300 kWh/m2 range). These same sites also enjoy the best wind resources in the country, allowing both solar and wind power plants to share not only the same land, but also the same electrical infrastructure in many cases. In this paper we present results on the performance assessment of five commercially-available PV technologies installed at an evaluation site next to a 95 MW wind farm. We discuss PV performance issues related to each of the PV technologies and the complementary nature of the solar and wind resource availability at the site.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0103-0108
PV Systems in Warm and Sunny Climates: Performance Assessment of Commercially Available Solar Photovoltaic Technologies under Different Climatic Conditions in the Brazilian Energy Mix
The performance assessment of seven different, commercially-available PV technologies was carried out at eight different climates in Brazil. The eight identical, fully-monitored 70 kWp photovoltaic Evaluation Sites (ESs) have all electrical and environmental parameters measured at one-second intervals. The R&D project, funded by twelve Brazilian Electric Utilities in the scope of the Brazilian National Regulatory Agency's R&D Program, aims at providing performance information for Utilities to make informed decisions on which PV technology to adopt in the forthcoming utility-scale solar energy auctions taking place in Brazil. The PV technologies evaluated are: thin-film amorphous silicon (a-Si), microcrystalline silicon (a-Si/μc-Si), cadmium telluride (CdTe), copper indium gallium diselenide (CIGS), and bulk mono and multi-crystalline silicon (c-Si and m-Si), all at fixed, latitude tilt, as well as double-axis tracking, concentrated PV (CPV) using InGap/GaAs/Ge at 820 suns concentration.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0103-0108
PV Systems in Warm and Sunny Climates: Performance Assessment of Commercially Available Solar Photovoltaic Technologies under Different Climatic Conditions in the Brazilian Energy Mix
The performance assessment of seven different, commercially-available PV technologies was carried out at eight different climates in Brazil. The eight identical, fully-monitored 70 kWp photovoltaic Evaluation Sites (ESs) have all electrical and environmental parameters measured at one-second intervals. The R&D project, funded by twelve Brazilian Electric Utilities in the scope of the Brazilian National Regulatory Agency's R&D Program, aims at providing performance information for Utilities to make informed decisions on which PV technology to adopt in the forthcoming utility-scale solar energy auctions taking place in Brazil. The PV technologies evaluated are: thin-film amorphous silicon (a-Si), microcrystalline silicon (a-Si/μc-Si), cadmium telluride (CdTe), copper indium gallium diselenide (CIGS), and bulk mono and multi-crystalline silicon (c-Si and m-Si), all at fixed, latitude tilt, as well as double-axis tracking, concentrated PV (CPV) using InGap/GaAs/Ge at 820 suns concentration.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01608371,p. 3372-3377
Fifteen years and counting: The reliable long-term performance of the first grid-connected, building-integrated, thin-film photovoltaic installation in Brazil
The first grid-connected, building-integrated, thin-film solar photovoltaic generator was installed in Brazil in 1997, and has been continuously operating ever since. The fully-monitored, 2kWp installation uses 40m 2 of glass-glass, double-junction, thin-film amorphous silicon (a-Si) PV laminates, which were installed as an overhang on the North-facing façade of the Solar Energy Laboratory at Universidade Federal de Santa Catarina (UFSC) in Florianopolis - South Brazil (Lat: 27°S). In this work we present some of the performance parameters over these 15 years of continuous operation, based on high-resolution operational data including AC and DC electrical parameters, temperature (ambient and back-of-module), and irradiance (horizontal and plane-of-array) measurements. Performance ratios (PR), annual energy yields, normalized power output, output degradation, seasonal annealing and other effects are also presented and discussed. The generator currently operates at a PR around 76%, and has an average annual energy yield of 1160 kWh/kWp for an average 1530 kWh/m 2 /year irradiation level at the site. After stabilization, PV modules annual degradation rates averaged at 0.55%/year over the 15 years period.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01608371,p. 3372-3377
Fifteen years and counting: The reliable long-term performance of the first grid-connected, building-integrated, thin-film photovoltaic installation in Brazil
The first grid-connected, building-integrated, thin-film solar photovoltaic generator was installed in Brazil in 1997, and has been continuously operating ever since. The fully-monitored, 2kWp installation uses 40m 2 of glass-glass, double-junction, thin-film amorphous silicon (a-Si) PV laminates, which were installed as an overhang on the North-facing façade of the Solar Energy Laboratory at Universidade Federal de Santa Catarina (UFSC) in Florianopolis - South Brazil (Lat: 27°S). In this work we present some of the performance parameters over these 15 years of continuous operation, based on high-resolution operational data including AC and DC electrical parameters, temperature (ambient and back-of-module), and irradiance (horizontal and plane-of-array) measurements. Performance ratios (PR), annual energy yields, normalized power output, output degradation, seasonal annealing and other effects are also presented and discussed. The generator currently operates at a PR around 76%, and has an average annual energy yield of 1160 kWh/kWp for an average 1530 kWh/m 2 /year irradiation level at the site. After stabilization, PV modules annual degradation rates averaged at 0.55%/year over the 15 years period.
- Open Access
- 1 January 2014
- Published by Elsevier in Energy Procedia
- Vol. 57, 226-234
Optimal Photovoltaic Inverter Sizing Considering Different Climate Conditions and Energy Prices
- 1 January 2014
- Published by Elsevier in Energy Procedia
- Vol. 57, 226-234
Open AccessOptimal Photovoltaic Inverter Sizing Considering Different Climate Conditions and Energy Prices