Mauricio Carmona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mauricio Carmona has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Cristóbal Cortés
Institute of Energy and Resources Efficiency of Aragón (ENERGAIA), University of Zaragoza, 50018 Zaragoza, Spain
5 shared publications - Jose Ignacio Huertas
Tecnológico de Monterrey
4 shared publications Mario Palacio
3 shared publications- Mario Palacio
Universidad Pontificia Bolivariana, Montería, Colombia
3 shared publications - Anggie Rincon Ortega
Rational Use of Energy and Environment Preservation Research Group from Universidad del Norte, Barranquilla, Atlántico 8600, Colombia
2 shared publications Anggie Rincón
2 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Enhancement of the thermal and structural properties of a phase change material (PCM) through microparticle addition using an experimental combined-model mixture design methodology
The use of paraffin as a phase change material (PCM) in thermal energy storage (TES) systems is fundamentally constrained by its inherently low thermal conductivity (≈0.2 W/m·K) and its tendency to leak due to volumetric expansion (≈12%) during melting. In this study, a form-stable NePCM was developed using a commercial PCM (RT45 paraffin), expanded graphite (EG) as a thermal conductivity enhancer, and expanded perlite (EP) as an inorganic structural matrix. To construct the empirical models, a combined-model mixture design methodology was employed and transformed into a pseudo-component mixture framework, enabling the simultaneous modeling of mass fractions and dependent categorical variables associated with the particle size of the powders used in the formulation (75 and 150 μm). Comprehensive analysis of variance (ANOVA) analytically demonstrated that particle size asymmetry induces a pronounced reduction in effective thermal conductivity due to increased interfacial Kapitza resistance (Rk), an antagonistic behavior that is often overlooked in hybrid mixtures. Overlay contour optimization identified an optimal formulation comprising 70 wt% paraffin, 20 wt% perlite, and 10 wt% graphite. Operating exclusively a stable isotropic particle size of 150 μm, this formulation completely suppressed liquid paraffin leakage (leakage ∼0%) at elevated temperatures (>50 °C) through constant capillary forces, while simultaneously increasing the effective thermal conductivity to ≈0.83 W/m·K. Differential scanning calorimetry (DSC) further confirmed a latent heat of fusion of 99.4 J/g, consistent with the PCM content in the optimized mixture. Overall, these findings establish a robust methodological framework for synthesizing a functionally superior material suitable for practical thermal energy storage applications
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnhancement of the thermal and structural properties of a phase change material (PCM) through microparticle addition using an experimental combined-model mixture design methodology
The use of paraffin as a phase change material (PCM) in thermal energy storage (TES) systems is fundamentally constrained by its inherently low thermal conductivity (≈0.2 W/m·K) and its tendency to leak due to volumetric expansion (≈12%) during melting. In this study, a form-stable NePCM was developed using a commercial PCM (RT45 paraffin), expanded graphite (EG) as a thermal conductivity enhancer, and expanded perlite (EP) as an inorganic structural matrix. To construct the empirical models, a combined-model mixture design methodology was employed and transformed into a pseudo-component mixture framework, enabling the simultaneous modeling of mass fractions and dependent categorical variables associated with the particle size of the powders used in the formulation (75 and 150 μm). Comprehensive analysis of variance (ANOVA) analytically demonstrated that particle size asymmetry induces a pronounced reduction in effective thermal conductivity due to increased interfacial Kapitza resistance (Rk), an antagonistic behavior that is often overlooked in hybrid mixtures. Overlay contour optimization identified an optimal formulation comprising 70 wt% paraffin, 20 wt% perlite, and 10 wt% graphite. Operating exclusively a stable isotropic particle size of 150 μm, this formulation completely suppressed liquid paraffin leakage (leakage ∼0%) at elevated temperatures (>50 °C) through constant capillary forces, while simultaneously increasing the effective thermal conductivity to ≈0.83 W/m·K. Differential scanning calorimetry (DSC) further confirmed a latent heat of fusion of 99.4 J/g, consistent with the PCM content in the optimized mixture. Overall, these findings establish a robust methodological framework for synthesizing a functionally superior material suitable for practical thermal energy storage applications
- Open Access
- 31 May 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 140, 573-584
Design and experimental characterization of a Micromix burner based on an optimized injection methodology
- 31 May 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 140, 573-584
Open AccessDesign and experimental characterization of a Micromix burner based on an optimized injection methodology
- Open Access
- 26 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 96, 622-638
Hydrogen combustion in micromix burners: Present stages, opportunities, and challenges
- 26 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 96, 622-638
Open AccessHydrogen combustion in micromix burners: Present stages, opportunities, and challenges
- Open Access
- 22 October 2024
- Published by Elsevier in Environmental and Sustainability Indicators
WITHDRAWN: Assessing energy vulnerability in Colombia using a multidimensional index
- 22 October 2024
- Published by Elsevier in Environmental and Sustainability Indicators
Open AccessWITHDRAWN: Assessing energy vulnerability in Colombia using a multidimensional index
- 10 June 2023
- Published by Elsevier in Transportation Research Part D: Transport and Environment
- Vol. 121
The energy efficiency of autorickshaws in a coastal region of Colombia
- 10 June 2023
- Published by Elsevier in Transportation Research Part D: Transport and Environment
- Vol. 121
The energy efficiency of autorickshaws in a coastal region of Colombia
- 2 November 2022
- Published by Elsevier in Solar Energy
- Vol. 247, 385-396
Effect of phase-change materials in the performance of a solar air heater
- 2 November 2022
- Published by Elsevier in Solar Energy
- Vol. 247, 385-396
Effect of phase-change materials in the performance of a solar air heater
- Open Access
Design and experimental evaluation of a Venturi and Venturi-Vortex microbubble aeration system
- Top Cited Papers
- 1 July 2021
- Published by Elsevier in Renewable Energy
- Vol. 172, 680-696
Experimental evaluation of a hybrid photovoltaic and thermal solar energy collector with integrated phase change material (PVT-PCM) in comparison with a traditional photovoltaic (PV) module
- 1 July 2021
- Published by Elsevier in Renewable Energy
- Vol. 172, 680-696
Top Cited PapersExperimental evaluation of a hybrid photovoltaic and thermal solar energy collector with integrated phase change material (PVT-PCM) in comparison with a traditional photovoltaic (PV) module
- Open Access
Reduced Model and Comparative Analysis of the Thermal Performance of Indirect Solar Dryer with and without PCM
A thermal model is proposed to analyze the performance of an indirect solar dryer (ISD) with latent heat storage using phase change material (PCM). The estimations are compared with experimental data presented in the scientific literature taken in real conditions. The validated thermal model is used in order to address a comprehensive analysis of the performance of the ISDs under the same operation conditions, the model is able to estimate the temperatures of glass cover, absorber plate, PCM, useful heat, thermal and storage efficiencies, and variables that are difficult to measure experimentally such as liquid fraction, heat losses, and accumulated energy of the ISDs. Three study cases are considered: Case 1 consists of two collectors with and without alternating nocturnal and diurnal operation (benchmarking case). Case 2 and 3 consist in a unique collector operating continuously for 24 h with PCM and without PCM, respectively. It was determined that the use of PCM in ISD increased the night thermal performance and extended the operational time of the system. On the other hand, results indicate that the use of two alternating collectors presents similar discharge behavior to using one collector with PCM operating continuously. Concerning the overall thermal performance, cases 1, 2, and 3 obtained thermal efficiencies of 20%, 28%, and 24%, respectively.
Open AccessReduced Model and Comparative Analysis of the Thermal Performance of Indirect Solar Dryer with and without PCM
A thermal model is proposed to analyze the performance of an indirect solar dryer (ISD) with latent heat storage using phase change material (PCM). The estimations are compared with experimental data presented in the scientific literature taken in real conditions. The validated thermal model is used in order to address a comprehensive analysis of the performance of the ISDs under the same operation conditions, the model is able to estimate the temperatures of glass cover, absorber plate, PCM, useful heat, thermal and storage efficiencies, and variables that are difficult to measure experimentally such as liquid fraction, heat losses, and accumulated energy of the ISDs. Three study cases are considered: Case 1 consists of two collectors with and without alternating nocturnal and diurnal operation (benchmarking case). Case 2 and 3 consist in a unique collector operating continuously for 24 h with PCM and without PCM, respectively. It was determined that the use of PCM in ISD increased the night thermal performance and extended the operational time of the system. On the other hand, results indicate that the use of two alternating collectors presents similar discharge behavior to using one collector with PCM operating continuously. Concerning the overall thermal performance, cases 1, 2, and 3 obtained thermal efficiencies of 20%, 28%, and 24%, respectively.