Nerly Deyanira Montañez-Supelano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nerly Deyanira Montañez-Supelano has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Anderson Sandoval-Amador
Materials and Sustainability Group, Department of Engineering, Universidad Loyola Andalucía, Dos Hermanas, Seville, Spain
5 shared publications D Y Peña-Ballesteros
Universidad Industrial de Santander, Bucaramanga, Colombia
4 shared publications- Darío Yesid Peña-Ballesteros
Universidad Industrial de Santander
3 shared publications D Y Peña Ballesteros
Universidad Industrial de Santander, Bucaramanga, Colombia
2 shared publicationsH A Estupiñan-Durán
Universidad Nacional de Colombia, Medellín, Colombia
2 shared publicationsA M Vera Arias
Universidad Industrial de Santander Bucaramanga Colombia
1 shared publication
Latest Publications
- Open Access
- 4 March 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (4) , 247
Tuning phase composition and morphology of calcium phosphate coatings on Ti6Al4V by pulse electrodeposition
This study investigates the influence of varying experimental parameters on the electrodeposition mechanism, phase composition, and morphology of calcium phosphate coatings synthesized by pulse electrodeposition on Ti6Al4V alloys. The objective is to optimize the pulse electrodeposition parameters to enhance the physicochemical properties of calcium phosphate coatings on Ti6Al4V alloys, aiming to improve bioactivity and osseointegration potential for biomedical applications. Cyclic voltammetry was used to elucidate the reaction mechanisms, while coatings were obtained under controlled pulsed potentials at two pH values (4.5 and 6.0) and three pulse ratios (t on /t off = 30/15, 60/30, and 120/60 seconds). The morphology, roughness, phase composition, and chemical structure of the coatings were characterized using scanning electron microscopy (SEM), confocal microscopy, X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The results revealed that pH and pulse duration have a substantial impact on the local electrochemical environment, influencing the phase composition (hydroxyapatite vs. brushite), surface roughness, and porosity. Coating produced at pH of 6 exhibited predominantly hydroxyapatite phases, whereas lower pH values led to biphasic compositions. The thickness and roughness of the coating showed a direct dependence on pulse duration. These findings demonstrate the feasibility of tailoring calcium phosphate coatings through pulse electrodeposition for enhanced biomedical performance.
- 4 March 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (4) , 247
Open AccessTuning phase composition and morphology of calcium phosphate coatings on Ti6Al4V by pulse electrodeposition
This study investigates the influence of varying experimental parameters on the electrodeposition mechanism, phase composition, and morphology of calcium phosphate coatings synthesized by pulse electrodeposition on Ti6Al4V alloys. The objective is to optimize the pulse electrodeposition parameters to enhance the physicochemical properties of calcium phosphate coatings on Ti6Al4V alloys, aiming to improve bioactivity and osseointegration potential for biomedical applications. Cyclic voltammetry was used to elucidate the reaction mechanisms, while coatings were obtained under controlled pulsed potentials at two pH values (4.5 and 6.0) and three pulse ratios (t on /t off = 30/15, 60/30, and 120/60 seconds). The morphology, roughness, phase composition, and chemical structure of the coatings were characterized using scanning electron microscopy (SEM), confocal microscopy, X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The results revealed that pH and pulse duration have a substantial impact on the local electrochemical environment, influencing the phase composition (hydroxyapatite vs. brushite), surface roughness, and porosity. Coating produced at pH of 6 exhibited predominantly hydroxyapatite phases, whereas lower pH values led to biphasic compositions. The thickness and roughness of the coating showed a direct dependence on pulse duration. These findings demonstrate the feasibility of tailoring calcium phosphate coatings through pulse electrodeposition for enhanced biomedical performance.
- Open Access
- 14 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-16
Functional evaluation and testing of a newly developed Teleost’s Fish Otolith derived biocomposite coating for healthcare
Polymers such as polycaprolactone (PCL) possess biodegradability, biocompatibility and affinity with other organic media that makes them suitable for biomedical applications. In this work, a novel biocomposite coating was synthesised by mixing PCL with layers of calcium phosphate (hydroxyapatite, brushite and monetite) from a biomineral called otolith extracted from Teleost fish (Plagioscion Squamosissimus) and multiwalled carbon nanotubes in different concentrations (0.5, 1.0 and 1.5 g/L). The biocomposite coating was deposited on an osteosynthesis material Ti6Al4V by spin coating and various tests such as Fourier transformation infrared spectroscopy (FTIR), Raman spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), scratch tests, MTT reduction cytotoxicity, HOS cell bioactivity (human osteosarcoma) by alkaline phosphatase (ALP) and fluorescence microscopy were performed to comprehensively evaluate the newly developed biocoating. It was found that an increase in the concentration of carbon nanotube induced microstructural phase changes of calcium phosphate (CP) leading to the formation of brushite, monetite and hydroxyapatite. While we discovered that an increase in the concentration of carbon nanotube generally improves the adhesion of the coating with the substrate, a certain threshold exists such that the best deposition surfaces were obtained as PCL/CP/CNT 0.0 g/L and PCL/CP/CNT 0.5 g/L.
- 14 January 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-16
Open AccessFunctional evaluation and testing of a newly developed Teleost’s Fish Otolith derived biocomposite coating for healthcare
Polymers such as polycaprolactone (PCL) possess biodegradability, biocompatibility and affinity with other organic media that makes them suitable for biomedical applications. In this work, a novel biocomposite coating was synthesised by mixing PCL with layers of calcium phosphate (hydroxyapatite, brushite and monetite) from a biomineral called otolith extracted from Teleost fish (Plagioscion Squamosissimus) and multiwalled carbon nanotubes in different concentrations (0.5, 1.0 and 1.5 g/L). The biocomposite coating was deposited on an osteosynthesis material Ti6Al4V by spin coating and various tests such as Fourier transformation infrared spectroscopy (FTIR), Raman spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), scratch tests, MTT reduction cytotoxicity, HOS cell bioactivity (human osteosarcoma) by alkaline phosphatase (ALP) and fluorescence microscopy were performed to comprehensively evaluate the newly developed biocoating. It was found that an increase in the concentration of carbon nanotube induced microstructural phase changes of calcium phosphate (CP) leading to the formation of brushite, monetite and hydroxyapatite. While we discovered that an increase in the concentration of carbon nanotube generally improves the adhesion of the coating with the substrate, a certain threshold exists such that the best deposition surfaces were obtained as PCL/CP/CNT 0.0 g/L and PCL/CP/CNT 0.5 g/L.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1386 (1) , 012010
Electrochemical and bioactive evaluation of polycaprolactone/multi-walled carbon nanotubes coatings on titanium alloy
Composite materials of polymer – carbon nanotubes have been widely studied for biomedical applications due to the versatility of polymers in this field and the excellent mechanical, thermal and electrical properties of carbon nanotubes. However, carbon nanotubes are materials which can provide some toxicity in biological systems, since they have low solubility in water and organic solvents, tend to form aggregates in solution, are bioincompatible and limited compatibility with polymeric matrices. For this reason, carbon nanotubes considered for biomedical applications must comply with this basic requirement of solubility. To improve the compatibility of the carbon nanotubes, they were exposed to treatment with HNO3, NaOH and HCl to eliminate impurities and improve the solubility in other solvents. Polycaprolactone coatings at 2.5% w/v and multi-wall carbon nanotubes (0.5, 1.0 and 1.5 g/L) were developed to evaluate the electrochemical and bioactive properties. Techniques such as infrared spectroscopy, contact angle, scanning electron microscopy, atomic force microscopy, electrochemical impedance spectroscopy using simulated body fluid as electrolyte and the bioactivity of human osteoseosarcoma cells (HOS ATCC® CRL-1543) by alkaline phosphatase were used. From the reported characterizations, it was observed that the resistance to polarization increases according to the degree of dispersion of carbon nanotubes present in the polymer matrix, decreasing the degradation rate of the material.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1386 (1) , 012010
Open AccessElectrochemical and bioactive evaluation of polycaprolactone/multi-walled carbon nanotubes coatings on titanium alloy
Composite materials of polymer – carbon nanotubes have been widely studied for biomedical applications due to the versatility of polymers in this field and the excellent mechanical, thermal and electrical properties of carbon nanotubes. However, carbon nanotubes are materials which can provide some toxicity in biological systems, since they have low solubility in water and organic solvents, tend to form aggregates in solution, are bioincompatible and limited compatibility with polymeric matrices. For this reason, carbon nanotubes considered for biomedical applications must comply with this basic requirement of solubility. To improve the compatibility of the carbon nanotubes, they were exposed to treatment with HNO3, NaOH and HCl to eliminate impurities and improve the solubility in other solvents. Polycaprolactone coatings at 2.5% w/v and multi-wall carbon nanotubes (0.5, 1.0 and 1.5 g/L) were developed to evaluate the electrochemical and bioactive properties. Techniques such as infrared spectroscopy, contact angle, scanning electron microscopy, atomic force microscopy, electrochemical impedance spectroscopy using simulated body fluid as electrolyte and the bioactivity of human osteoseosarcoma cells (HOS ATCC® CRL-1543) by alkaline phosphatase were used. From the reported characterizations, it was observed that the resistance to polarization increases according to the degree of dispersion of carbon nanotubes present in the polymer matrix, decreasing the degradation rate of the material.
- Open Access
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012033
Corrosion of Ti6Al4V ELI surfaces texturized by CO2laser in SBF
The purpose of our study was to evaluate the corrosion behavior of Ti6Al4V ELI surfaces textured with linear geometry using a CO2 laser. The linear geometry of the textures was obtained using a laserpro X380RX device with a 40W power supply. The characterization of the textured surface was performed by scanning electron microscope and X-ray dispersive energy spectroscopy. The effect of the separation distance of the linear textures on the corrosion resistance of the Ti6Al4V ELI alloy was evaluated by resistance to linear polarization, electrochemical impedance spectroscopy and potentiodynamic polarization curves in SBF. The results showed that the separation distance of the linear textures does not generate a significant effect on the corrosion resistance of the material. However, all the textured surfaces presented less resistance to corrosion than the unmodified material. This decrease in the corrosion resistance is attributed to the inclusion of elements such as molybdenum, silicon and phosphorus that are present in the lines due to the implementation of the cermark coating prior to the laser textured process.
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012033
Open AccessCorrosion of Ti6Al4V ELI surfaces texturized by CO2laser in SBF
The purpose of our study was to evaluate the corrosion behavior of Ti6Al4V ELI surfaces textured with linear geometry using a CO2 laser. The linear geometry of the textures was obtained using a laserpro X380RX device with a 40W power supply. The characterization of the textured surface was performed by scanning electron microscope and X-ray dispersive energy spectroscopy. The effect of the separation distance of the linear textures on the corrosion resistance of the Ti6Al4V ELI alloy was evaluated by resistance to linear polarization, electrochemical impedance spectroscopy and potentiodynamic polarization curves in SBF. The results showed that the separation distance of the linear textures does not generate a significant effect on the corrosion resistance of the material. However, all the textured surfaces presented less resistance to corrosion than the unmodified material. This decrease in the corrosion resistance is attributed to the inclusion of elements such as molybdenum, silicon and phosphorus that are present in the lines due to the implementation of the cermark coating prior to the laser textured process.
- Open Access
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012032
The effect of pulsed current electrodeposition parameters of calcium phosphates coating on Ti6Al4V ELI
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012032
Open AccessThe effect of pulsed current electrodeposition parameters of calcium phosphates coating on Ti6Al4V ELI
- Open Access
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012051
Evaluation of corrosion products formed by sulfidation as inhibitors of the naphthenic corrosion of AISI-316 steel
Naphthenic acids present in oil from most regions worldwide currently stand as the main responsible for the naphthenic corrosion problems, affecting the oil-refining industry. The phenomenon of sulfidation, accompanying corrosion processes brought about by naphthenic acids in high-temperature refining plant applications, takes place when the combination of sulfidic acid (H2S) with Fe forms layers of iron sulphide (FeS) on the material surface, layers with the potential to protect the material from attack by other corrosive species like naphthenic acids. This work assessed corrosion products formed by sulfidation as inhibitors of naphthenic corrosion rate in AISI-316 steel exposed to processing conditions of simulated crude oil in a dynamic autoclave. Calculation of the sulfidation and naphthenic corrosion rates were determined by gravimetry. The surfaces of the AISI-316 gravimetric coupons exposed to acid systems; were characterized morphologically by X-Ray Diffraction (XRD) and X-ray Fluorescence by Energy Dispersive Spectroscopy (EDS) combined with Scanning Electron Microscopy (SEM). One of the results obtained was the determination of an inhibiting effect of corrosion products at 250 and 300°C, where lower corrosion rate levels were detected. For the temperature of 350°C, naphthenic corrosion rates increased due to deposition of naphthenic acids on the areas where corrosion products formed by sulfidation have lower homogeneity and stability on the surface, thus accelerating the destruction of AISI-316 steel. The above provides an initial contribution to oil industry in search of new alternatives to corrosion control by the attack of naphthenic acids, from the formation of FeS layers on exposed materials in the processing of heavy crude oils with high sulphur content.
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012051
Open AccessEvaluation of corrosion products formed by sulfidation as inhibitors of the naphthenic corrosion of AISI-316 steel
Naphthenic acids present in oil from most regions worldwide currently stand as the main responsible for the naphthenic corrosion problems, affecting the oil-refining industry. The phenomenon of sulfidation, accompanying corrosion processes brought about by naphthenic acids in high-temperature refining plant applications, takes place when the combination of sulfidic acid (H2S) with Fe forms layers of iron sulphide (FeS) on the material surface, layers with the potential to protect the material from attack by other corrosive species like naphthenic acids. This work assessed corrosion products formed by sulfidation as inhibitors of naphthenic corrosion rate in AISI-316 steel exposed to processing conditions of simulated crude oil in a dynamic autoclave. Calculation of the sulfidation and naphthenic corrosion rates were determined by gravimetry. The surfaces of the AISI-316 gravimetric coupons exposed to acid systems; were characterized morphologically by X-Ray Diffraction (XRD) and X-ray Fluorescence by Energy Dispersive Spectroscopy (EDS) combined with Scanning Electron Microscopy (SEM). One of the results obtained was the determination of an inhibiting effect of corrosion products at 250 and 300°C, where lower corrosion rate levels were detected. For the temperature of 350°C, naphthenic corrosion rates increased due to deposition of naphthenic acids on the areas where corrosion products formed by sulfidation have lower homogeneity and stability on the surface, thus accelerating the destruction of AISI-316 steel. The above provides an initial contribution to oil industry in search of new alternatives to corrosion control by the attack of naphthenic acids, from the formation of FeS layers on exposed materials in the processing of heavy crude oils with high sulphur content.
- Open Access
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012037
A novel biphasic calcium phosphate derived from fish otoliths
- 28 December 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 935 (1) , 012037
Open AccessA novel biphasic calcium phosphate derived from fish otoliths
- Open Access
- 24 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 786 (1) , 012010
HOS cell adhesion on TiO2nanotubes texturized by laser engraving
Due to its outstanding properties, the titanium and its alloys have been widely used in the dental and orthopaedic fields as biomaterials. The TiO 2 nanotubes surface and the texturized process by laser engraving enables significantly accelerated osteoblast adhesion on the biomaterial. For this reason in this paper, the HOS cell responses on TiO 2 nanotubes fabricated on Ti6Al4V alloy and texturized by laser engraving were evaluated. The test surfaces were carried out on smooth Ti6Al4V as control, TiO 2 nanotubes (NT) and surfaces with micropoints obtained by laser engraving, with 1mm spacing (NTP1) and 0.5mm (NTP2). The results show that the texturized process enables decreases the contact angle thus improving wettability of the TiO 2 nanotubes surface. The NTP1 and NTP2 surfaces show excellent cell adhesion and spreading on the surface, which is evident in epifluorescence microscopy images. Furthermore, the NTP1 and NTP2 surfaces improved the cell proliferation at 18% and 16% respectively in relation with NT surface, showing that the laser texturing improves cell response of TiO 2 nanotubes.
- 24 January 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 786 (1) , 012010
Open AccessHOS cell adhesion on TiO2nanotubes texturized by laser engraving
Due to its outstanding properties, the titanium and its alloys have been widely used in the dental and orthopaedic fields as biomaterials. The TiO 2 nanotubes surface and the texturized process by laser engraving enables significantly accelerated osteoblast adhesion on the biomaterial. For this reason in this paper, the HOS cell responses on TiO 2 nanotubes fabricated on Ti6Al4V alloy and texturized by laser engraving were evaluated. The test surfaces were carried out on smooth Ti6Al4V as control, TiO 2 nanotubes (NT) and surfaces with micropoints obtained by laser engraving, with 1mm spacing (NTP1) and 0.5mm (NTP2). The results show that the texturized process enables decreases the contact angle thus improving wettability of the TiO 2 nanotubes surface. The NTP1 and NTP2 surfaces show excellent cell adhesion and spreading on the surface, which is evident in epifluorescence microscopy images. Furthermore, the NTP1 and NTP2 surfaces improved the cell proliferation at 18% and 16% respectively in relation with NT surface, showing that the laser texturing improves cell response of TiO 2 nanotubes.
- Open Access
- 1 April 2016
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 24 (2) , 215-227
Respuesta dieléctrica y bioquímica de un recubrimiento PLA-PGA-HAp-Quitosano-Colágeno sobre Ti6Al4V
Se evaluó la interacción de un biomaterial polimérico con medio de cultivo y células osteoblásticas, electrodepositado sobre Ti6Al4V. El compuesto está integrado por ácido poliláctico-ácido poliglicólicohidroxiapatita, modificado con quitosano y colágeno. Se calculó la permitividad relativa con los datos de impedancia plasmada en un espectro dieléctrico que permitió identificar las dispersiones alfa y beta, relacionadas con el intercambio iónico y la polarización de la membrana celular. La adhesión y proliferación celular se analizaron mediante microscopia de epifluorescencia, en donde fue posible observar al tercer día del cultivo celular el proceso de mitosis representado por la condensación del núcleo y la separación de los cromosomas. Se observó la morfología de la superficie del biomaterial mediante SEM (Scanning Electron Microscope) y AFM (Atomic Force Microscope) y se evaluó la actividad celular mediante la medición de fosfatasa alcalina. Finalmente se encontró la mejor superficie para la adhesión y crecimiento celular mediante análisis estadístico, que correspondió al recubrimiento con la mayor concentración de quitosano y colágeno.
- 1 April 2016
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 24 (2) , 215-227
Open AccessRespuesta dieléctrica y bioquímica de un recubrimiento PLA-PGA-HAp-Quitosano-Colágeno sobre Ti6Al4V
Se evaluó la interacción de un biomaterial polimérico con medio de cultivo y células osteoblásticas, electrodepositado sobre Ti6Al4V. El compuesto está integrado por ácido poliláctico-ácido poliglicólicohidroxiapatita, modificado con quitosano y colágeno. Se calculó la permitividad relativa con los datos de impedancia plasmada en un espectro dieléctrico que permitió identificar las dispersiones alfa y beta, relacionadas con el intercambio iónico y la polarización de la membrana celular. La adhesión y proliferación celular se analizaron mediante microscopia de epifluorescencia, en donde fue posible observar al tercer día del cultivo celular el proceso de mitosis representado por la condensación del núcleo y la separación de los cromosomas. Se observó la morfología de la superficie del biomaterial mediante SEM (Scanning Electron Microscope) y AFM (Atomic Force Microscope) y se evaluó la actividad celular mediante la medición de fosfatasa alcalina. Finalmente se encontró la mejor superficie para la adhesión y crecimiento celular mediante análisis estadístico, que correspondió al recubrimiento con la mayor concentración de quitosano y colágeno.
- Open Access
- 1 January 2016
- Published by Universidad de Antioquia in Revista Facultad de Odontología
- Vol. 28 (1) , 54-70
Corrosión de nitinol bajo tensiones de fuerza en fluido fisiológico simulado con y sin fluoruros
- 1 January 2016
- Published by Universidad de Antioquia in Revista Facultad de Odontología
- Vol. 28 (1) , 54-70
Open AccessCorrosión de nitinol bajo tensiones de fuerza en fluido fisiológico simulado con y sin fluoruros