Juha Pärkkä
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Juha Pärkkä has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Ilkka Korhonen
VTT Information Technology, Tampere, Finland
14 shared publications - Mark van Gils
Tampere University
8 shared publications - Elina Mattila
VTT Technical Research Centre of Finland Ltd Tampere Finland
4 shared publications - Jani Mäntyjärvi
Sensing Solutions, VTT Technical Research Centre of Finland, Espoo, Finland
4 shared publications Miikka Ermes
Technical Research Centre of Finland, P.O.Box 1300, 33101 Tampere, Finland
4 shared publications- Miikka Ermes
VTT Technical Research Centre of Finland, P.O. Box 1300, FI-33101, Tampere, Finland
3 shared publications
Latest Publications
- Open Access
- 1 April 2022
- Published by Elsevier in Environmental Research
- Vol. 206, 112428
Urban grey spaces are associated with increased allergy in the general population
- 1 April 2022
- Published by Elsevier in Environmental Research
- Vol. 206, 112428
Open AccessUrban grey spaces are associated with increased allergy in the general population
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 19 (1) , 227-235
Improvement of Force-Sensor-Based Heart Rate Estimation Using Multichannel Data Fusion
The aim of this paper is to present and evaluate algorithms for heartbeat interval estimation from multiple spatially distributed force sensors integrated into a bed. Moreover, the benefit of using multichannel systems as opposed to a single sensor is investigated. While it might seem intuitive that multiple channels are superior to a single channel, the main challenge lies in finding suitable methods to actually leverage this potential. To this end, two algorithms for heart rate estimation from multichannel vibration signals are presented and compared against a single-channel sensing solution. The first method operates by analyzing the cepstrum computed from the average spectra of the individual channels, while the second method applies Bayesian fusion to three interval estimators, such as the autocorrelation, which are applied to each channel. This evaluation is based on 28 night-long sleep lab recordings during which an eight-channel polyvinylidene fluoride-based sensor array was used to acquire cardiac vibration signals. The recruited patients suffered from different sleep disorders of varying severity. From the sensor array data, a virtual single-channel signal was also derived for comparison by averaging the channels. The single-channel results achieved a beat-to-beat interval error of 2.2% with a coverage (i.e., percentage of the recording which could be analyzed) of 68.7%. In comparison, the best multichannel results attained a mean error and coverage of 1.0% and 81.0%, respectively. These results present statistically significant improvements of both metrics over the single-channel results (p <; 0.05).
- 1 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 19 (1) , 227-235
Improvement of Force-Sensor-Based Heart Rate Estimation Using Multichannel Data Fusion
The aim of this paper is to present and evaluate algorithms for heartbeat interval estimation from multiple spatially distributed force sensors integrated into a bed. Moreover, the benefit of using multichannel systems as opposed to a single sensor is investigated. While it might seem intuitive that multiple channels are superior to a single channel, the main challenge lies in finding suitable methods to actually leverage this potential. To this end, two algorithms for heart rate estimation from multichannel vibration signals are presented and compared against a single-channel sensing solution. The first method operates by analyzing the cepstrum computed from the average spectra of the individual channels, while the second method applies Bayesian fusion to three interval estimators, such as the autocorrelation, which are applied to each channel. This evaluation is based on 28 night-long sleep lab recordings during which an eight-channel polyvinylidene fluoride-based sensor array was used to acquire cardiac vibration signals. The recruited patients suffered from different sleep disorders of varying severity. From the sensor array data, a virtual single-channel signal was also derived for comparison by averaging the channels. The single-channel results achieved a beat-to-beat interval error of 2.2% with a coverage (i.e., percentage of the recording which could be analyzed) of 68.7%. In comparison, the best multichannel results attained a mean error and coverage of 1.0% and 81.0%, respectively. These results present statistically significant improvements of both metrics over the single-channel results (p <; 0.05).
- 1 January 2014
- Published by Georg Thieme Verlag KG in Methods of Information in Medicine
- Vol. 53 (04) , 308-313
Monitoring Nocturnal Heart Rate with Bed Sensor
Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on “Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems”. Objectives: The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Methods: Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. Results: On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. Conclusions: The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.
- 1 January 2014
- Published by Georg Thieme Verlag KG in Methods of Information in Medicine
- Vol. 53 (04) , 308-313
Monitoring Nocturnal Heart Rate with Bed Sensor
Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on “Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems”. Objectives: The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Methods: Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. Results: On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. Conclusions: The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Guided physical exercise of cardiac patients during rehabilitation: Adherence and changes in physiological variables
A system to provide cardiac patients with the possibility to perform safe and beneficial exercise during their rehabilitation was developed within the EU project Heartcycle. Within the system, algorithms use physiological signals from a wearable device (embedded in a shirt) to guide the patient through the exercise. After having been technically validated, the system was deployed for clinical evaluation with 63 patients in Germany (21), Great Britain (25) and Spain (17). The paper describes the first findings of this evaluation study with respect to: technical feasibility, adherence of the patients to the prescribed exercise protocol, and changes in physiological observables as the patients follow their exercise plan. Technically, the system functioned well, and overall the adherence of those patients that actually started using the system was stable, or even improving, in the vast majority of cases. An increase was especially seen in adherence to the protocol set for the warm-up phase of the exercise. This is an important finding for a group of patients that is known to have declining adherence to rehabilitation recommendations in the long term. The recovery analysis showed that especially the recovery of the heart rate as measured in the first minute after the exercise end showed improvement over time.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Guided physical exercise of cardiac patients during rehabilitation: Adherence and changes in physiological variables
A system to provide cardiac patients with the possibility to perform safe and beneficial exercise during their rehabilitation was developed within the EU project Heartcycle. Within the system, algorithms use physiological signals from a wearable device (embedded in a shirt) to guide the patient through the exercise. After having been technically validated, the system was deployed for clinical evaluation with 63 patients in Germany (21), Great Britain (25) and Spain (17). The paper describes the first findings of this evaluation study with respect to: technical feasibility, adherence of the patients to the prescribed exercise protocol, and changes in physiological observables as the patients follow their exercise plan. Technically, the system functioned well, and overall the adherence of those patients that actually started using the system was stable, or even improving, in the vast majority of cases. An increase was especially seen in adherence to the protocol set for the warm-up phase of the exercise. This is an important finding for a group of patients that is known to have declining adherence to rehabilitation recommendations in the long term. The recovery analysis showed that especially the recovery of the heart rate as measured in the first minute after the exercise end showed improvement over time.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 8299-8302
A personalized approach for predicting the effect of aerobic exercise on blood pressure using a Fuzzy Inference System
Regular aerobic exercise is a recommended treatment for elevated blood pressure (BP). However, making permanent lifestyle changes is not easy. Having personally relevant information about the treatment, about its effects and importance, is a precondition for motivation. Thus, the first step towards a successful lifestyle change is appropriate education. This paper describes a Sugeno-type Fuzzy Inference System (FIS) that predicts the effect of regular aerobic exercise on blood pressure based on the exercise dose variables, exercise frequency and intensity, as well as demographics (age, gender, ethnicity), and the baseline BP of a person. Since BP response to exercise varies largely between individuals, the system takes an initial step towards personalized prediction. Hence, the system can be used to educate a person about the benefits of exercise on BP in a personally relevant way, providing more accurate information than traditional education materials. Furthermore, preliminary validation results of the performance of the FIS are promising. The predictions comply with the findings of medical research for populations, though the individual-level validation remains still to be done.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 8299-8302
A personalized approach for predicting the effect of aerobic exercise on blood pressure using a Fuzzy Inference System
Regular aerobic exercise is a recommended treatment for elevated blood pressure (BP). However, making permanent lifestyle changes is not easy. Having personally relevant information about the treatment, about its effects and importance, is a precondition for motivation. Thus, the first step towards a successful lifestyle change is appropriate education. This paper describes a Sugeno-type Fuzzy Inference System (FIS) that predicts the effect of regular aerobic exercise on blood pressure based on the exercise dose variables, exercise frequency and intensity, as well as demographics (age, gender, ethnicity), and the baseline BP of a person. Since BP response to exercise varies largely between individuals, the system takes an initial step towards personalized prediction. Hence, the system can be used to educate a person about the benefits of exercise on BP in a personally relevant way, providing more accurate information than traditional education materials. Furthermore, preliminary validation results of the performance of the FIS are promising. The predictions comply with the findings of medical research for populations, though the individual-level validation remains still to be done.
- 1 January 2011
- Published by ACTA Press
Connections of Daytime Napping and Vigilance Measures to Activity Behaviour and Physical Functioning
Ability to do different daily activities defines partly one’s independency.
- 1 January 2011
- Published by ACTA Press
Connections of Daytime Napping and Vigilance Measures to Activity Behaviour and Physical Functioning
Ability to do different daily activities defines partly one’s independency.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Automatic feature selection and classification of physical and mental load using data from wearable sensors
Long-term monitoring of health is essential in many chronic conditions, but automatic monitoring is not yet utilized routinely with mental stress. Accelerometers, magnetometers, ECG, respiratory effort, skin temperature and pulse oximetry were used with 12 health volunteers in this study for monitoring 1) heavy mental load, 2) normal mental load, 3) walking, 4) running and 5) lying. Heavy mental load consisted of a 20-min IQ test and normal mental load was represented by reading a comic book. Automatic feature selection using sequential forward search was used to select the best features for classification of the five activities. Normalized heart rate, utilizing activity context information was found to be the most powerful feature for discriminating heavy mental load from normal. Classification accuracy for all 5 activities was 89% with a custom decision tree and with a k-nearest neighbor classifier and 85% with an artificial neural network.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Automatic feature selection and classification of physical and mental load using data from wearable sensors
Long-term monitoring of health is essential in many chronic conditions, but automatic monitoring is not yet utilized routinely with mental stress. Accelerometers, magnetometers, ECG, respiratory effort, skin temperature and pulse oximetry were used with 12 health volunteers in this study for monitoring 1) heavy mental load, 2) normal mental load, 3) walking, 4) running and 5) lying. Heavy mental load consisted of a 20-min IQ test and normal mental load was represented by reading a comic book. Automatic feature selection using sequential forward search was used to select the best features for classification of the five activities. Normalized heart rate, utilizing activity context information was found to be the most powerful feature for discriminating heavy mental load from normal. Classification accuracy for all 5 activities was 89% with a custom decision tree and with a k-nearest neighbor classifier and 85% with an artificial neural network.
- 28 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Technology in Biomedicine
- Vol. 14 (5) , 1211-1215
Personalization Algorithm for Real-Time Activity Recognition Using PDA, Wireless Motion Bands, and Binary Decision Tree
Inactive and sedentary lifestyle is a major problem in many industrialized countries today. Automatic recognition of type of physical activity can be used to show the user the distribution of his daily activities and to motivate him into more active lifestyle. In this study, an automatic activity-recognition system consisting of wireless motion bands and a PDA is evaluated. The system classifies raw sensor data into activity types online. It uses a decision tree classifier, which has low computational cost and low battery consumption. The classifier parameters can be personalized online by performing a short bout of an activity and by telling the system which activity is being performed. Data were collected with seven volunteers during five everyday activities: lying, sitting/standing, walking, running, and cycling. The online system can detect these activities with overall 86.6% accuracy and with 94.0% accuracy after classifier personalization.
- 28 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Technology in Biomedicine
- Vol. 14 (5) , 1211-1215
Personalization Algorithm for Real-Time Activity Recognition Using PDA, Wireless Motion Bands, and Binary Decision Tree
Inactive and sedentary lifestyle is a major problem in many industrialized countries today. Automatic recognition of type of physical activity can be used to show the user the distribution of his daily activities and to motivate him into more active lifestyle. In this study, an automatic activity-recognition system consisting of wireless motion bands and a PDA is evaluated. The system classifies raw sensor data into activity types online. It uses a decision tree classifier, which has low computational cost and low battery consumption. The classifier parameters can be personalized online by performing a short bout of an activity and by telling the system which activity is being performed. Data were collected with seven volunteers during five everyday activities: lying, sitting/standing, walking, running, and cycling. The online system can detect these activities with overall 86.6% accuracy and with 94.0% accuracy after classifier personalization.
- 18 May 2010
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 16 (5) , 260-264
Use of a mobile phone diary for observing weight management and related behaviours
We studied self-observations related to weight management recorded with a Wellness Diary application on a mobile phone. The data were recorded by 27 participants in a 12-week study, which included a short weight management lecture followed by independent usage of the Wellness Diary. We studied the validity of self-observed weight, and behavioural changes and weight patterns related to weight management success. Self-observed weight data tended to underestimate pre- and poststudy measurements, but there were high correlations between the measures (r ≥ 0.80). The amount of physical activity correlated significantly with weight loss (r = 0.44) as did different measures representing healthy changes in dietary behaviours (r ≥ 0.45). Weight changes and the weekly rhythms of weight indicated a strong tendency to compensate for high-risk periods among successful weight-losers compared to unsuccessful ones. These preliminary results suggest that the mobile phone diary is a valid tool for observing weight management and related behaviours.
- 18 May 2010
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 16 (5) , 260-264
Use of a mobile phone diary for observing weight management and related behaviours
We studied self-observations related to weight management recorded with a Wellness Diary application on a mobile phone. The data were recorded by 27 participants in a 12-week study, which included a short weight management lecture followed by independent usage of the Wellness Diary. We studied the validity of self-observed weight, and behavioural changes and weight patterns related to weight management success. Self-observed weight data tended to underestimate pre- and poststudy measurements, but there were high correlations between the measures (r ≥ 0.80). The amount of physical activity correlated significantly with weight loss (r = 0.44) as did different measures representing healthy changes in dietary behaviours (r ≥ 0.45). Weight changes and the weekly rhythms of weight indicated a strong tendency to compensate for high-risk periods among successful weight-losers compared to unsuccessful ones. These preliminary results suggest that the mobile phone diary is a valid tool for observing weight management and related behaviours.