Duncan Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Duncan Smith has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Brian Crook
Health and Safety Executive (HSE) Science and Research Centre, Harpur Hill, Buxton SK17 9JN, UK
4 shared publications - Charlotte Young
Science and Research Centre, Health and Safety Executive, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK
3 shared publications - Ceri Rideout
Specialist Division Occupational Hygiene, Health and Safety Executive, Cardiff CF10 1EP, UK
1 shared publication - Ceri Ridout
Health and Safety Executive, UK
1 shared publication - Helena Senior
Health and Safety Executive (HSE) Science and Research Centre, Harpur Hill, Buxton SK17 9JN, UK
1 shared publication - Jodi Brookes
The National Institute of Health Research Health Protection Research Unit in Environmental Exposures and Health Developmental Award, University of Leicester, Leicester, LE1 7LW, UK; Health and Safety Executive, Science and Research Centre, Buxton, SK17 9JN, UK
1 shared publication
Latest Publications
- Open Access
- 15 May 2025
- Published by MDPI AG in Microorganisms
- Vol. 13 (5) , 1134
Legionella in Hot Water Heat Pump (HWHP) Systems
It is anticipated that by 2028 there will be a significant increase in the use of HWHP systems in Great Britain (GB). Such systems are considered a better, energy-efficient alternative to fossil fuel-based burners and furnaces, as they use electricity. There are concerns that these systems are susceptible to microbial contamination because they hold water at lower temperatures. In particular, the concern is regarding Legionella contamination, as it can potentially cause disease in the general public and those who are maintaining and replacing these systems. Therefore, this review was focused on understanding the potential risk posed by their increased use and maintenance requirements. This review was approached systematically but was not a full systematic review. There were 61 papers that were considered potentially relevant to the research questions. Of these, 40 papers were considered relevant to the topic of Legionella in HWHP and underwent full article assessment and data extraction. The remaining papers were considered useful for background information. The scope of this review established that Legionella are a known risk in hot water systems that can be carried over to HWHP systems, yet there is minimal evidence to suggest that the current control measures are being appropriately applied to reduce the risk of exposure. When considering countrywide legislation and guidance, it appears that the risk is considered lower in single- or multi-family homes that do not require a centralised system. This review included the assessment of information regarding the safety of working with HWHP systems with regards to maintenance and replacement. The authors found a lack of information regarding these safety concerns. This review is among the first to systematically evaluate the risks of Legionella contamination in HWHP systems.
- 15 May 2025
- Published by MDPI AG in Microorganisms
- Vol. 13 (5) , 1134
Open AccessLegionella in Hot Water Heat Pump (HWHP) Systems
It is anticipated that by 2028 there will be a significant increase in the use of HWHP systems in Great Britain (GB). Such systems are considered a better, energy-efficient alternative to fossil fuel-based burners and furnaces, as they use electricity. There are concerns that these systems are susceptible to microbial contamination because they hold water at lower temperatures. In particular, the concern is regarding Legionella contamination, as it can potentially cause disease in the general public and those who are maintaining and replacing these systems. Therefore, this review was focused on understanding the potential risk posed by their increased use and maintenance requirements. This review was approached systematically but was not a full systematic review. There were 61 papers that were considered potentially relevant to the research questions. Of these, 40 papers were considered relevant to the topic of Legionella in HWHP and underwent full article assessment and data extraction. The remaining papers were considered useful for background information. The scope of this review established that Legionella are a known risk in hot water systems that can be carried over to HWHP systems, yet there is minimal evidence to suggest that the current control measures are being appropriately applied to reduce the risk of exposure. When considering countrywide legislation and guidance, it appears that the risk is considered lower in single- or multi-family homes that do not require a centralised system. This review included the assessment of information regarding the safety of working with HWHP systems with regards to maintenance and replacement. The authors found a lack of information regarding these safety concerns. This review is among the first to systematically evaluate the risks of Legionella contamination in HWHP systems.
- Open Access
- 20 August 2024
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 21 (8) , 1101
The Contribution of Legionella anisa to Legionella Contamination of Water in the Built Environment
Legionella bacteria can proliferate in poorly maintained water systems, posing risks to users. All Legionella species are potentially pathogenic, but Legionella pneumophila (L. pneumophila) is usually the primary focus of testing. However, Legionella anisa (L. anisa) also colonizes water distribution systems, is frequently found with L. pneumophila, and could be a good indicator for increased risk of nosocomial infection. Anonymized data from three commercial Legionella testing laboratories afforded an analysis of 565,750 water samples. The data covered July 2019 to August 2021, including the COVID-19 pandemic. The results confirmed that L. anisa commonly colonizes water distribution systems, being the most frequently identified non-L. pneumophila species. The proportions of L. anisa and L. pneumophila generally remained similar, but increases in L. pneumophila during COVID-19 lockdown suggest static water supplies might favor its growth. Disinfection of hospital water systems was effective, but re-colonization did occur, appearing to favor L. pneumophila; however, L. anisa colony numbers also increased as a proportion of the total. While L. pneumophila remains the main species of concern as a risk to human health, L. anisa’s role should not be underestimated, either as a potential infection risk or as an indicator of the need to intervene to control Legionella’s colonization of water supplies.
- 20 August 2024
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 21 (8) , 1101
Open AccessThe Contribution of Legionella anisa to Legionella Contamination of Water in the Built Environment
Legionella bacteria can proliferate in poorly maintained water systems, posing risks to users. All Legionella species are potentially pathogenic, but Legionella pneumophila (L. pneumophila) is usually the primary focus of testing. However, Legionella anisa (L. anisa) also colonizes water distribution systems, is frequently found with L. pneumophila, and could be a good indicator for increased risk of nosocomial infection. Anonymized data from three commercial Legionella testing laboratories afforded an analysis of 565,750 water samples. The data covered July 2019 to August 2021, including the COVID-19 pandemic. The results confirmed that L. anisa commonly colonizes water distribution systems, being the most frequently identified non-L. pneumophila species. The proportions of L. anisa and L. pneumophila generally remained similar, but increases in L. pneumophila during COVID-19 lockdown suggest static water supplies might favor its growth. Disinfection of hospital water systems was effective, but re-colonization did occur, appearing to favor L. pneumophila; however, L. anisa colony numbers also increased as a proportion of the total. While L. pneumophila remains the main species of concern as a risk to human health, L. anisa’s role should not be underestimated, either as a potential infection risk or as an indicator of the need to intervene to control Legionella’s colonization of water supplies.
- Open Access
- 4 July 2024
- Published by MDPI AG in Preprints.org
The Contribution of Legionella anisa to Legionella Contamination of Water in the Built Environment
Legionella bacteria can proliferate in poorly maintained water systems, posing risks to users. All Legionella species are potentially pathogenic but Legionella pneumophila (L. pneumophila) is usually the primary focus of testing. However, Legionella anisa (L. anisa) also colonises water distribution systems, is frequently found with L. pneumophila and could be a good indicator for increased risk of nosocomial infection. Anonymized data from three commercial Legionella testing laboratories afforded analysis of 565,750 water samples. Data covered July 2019 to August 2021, including the COVID-19 pandemic. Results confirmed L. anisa commonly colonises water distribution systems, being the most frequently identified non-L. pneumophila species. Proportions of L. anisa and L. pneumophila generally remained similar but increases in L. pneumophila during COVID-19 lockdown suggests static water supplies might favour its growth. Disinfection of hospital water systems was effective but re-colonization did occur, appearing to favour L. pneumophila, although L. anisa colony numbers also increased as a proportion of the total. While L. pneumophila remains the main species of concern as a risk to human health, L. anisa’s role should not be under-estimated, either as a potential infection risk or as an indicator of the need to intervene to control Legionella colonization of water supplies.
- 4 July 2024
- Published by MDPI AG in Preprints.org
Open AccessThe Contribution of Legionella anisa to Legionella Contamination of Water in the Built Environment
Legionella bacteria can proliferate in poorly maintained water systems, posing risks to users. All Legionella species are potentially pathogenic but Legionella pneumophila (L. pneumophila) is usually the primary focus of testing. However, Legionella anisa (L. anisa) also colonises water distribution systems, is frequently found with L. pneumophila and could be a good indicator for increased risk of nosocomial infection. Anonymized data from three commercial Legionella testing laboratories afforded analysis of 565,750 water samples. Data covered July 2019 to August 2021, including the COVID-19 pandemic. Results confirmed L. anisa commonly colonises water distribution systems, being the most frequently identified non-L. pneumophila species. Proportions of L. anisa and L. pneumophila generally remained similar but increases in L. pneumophila during COVID-19 lockdown suggests static water supplies might favour its growth. Disinfection of hospital water systems was effective but re-colonization did occur, appearing to favour L. pneumophila, although L. anisa colony numbers also increased as a proportion of the total. While L. pneumophila remains the main species of concern as a risk to human health, L. anisa’s role should not be under-estimated, either as a potential infection risk or as an indicator of the need to intervene to control Legionella colonization of water supplies.
- Open Access
- 17 March 2021
- Published by MDPI AG in Microorganisms
- Vol. 9 (3) , 615
Rapid Testing and Interventions to Control Legionella Proliferation following a Legionnaires’ Disease Outbreak Associated with Cooling Towers
Most literature to date on the use of rapid Legionella tests have compared different sampling and analytical techniques, with few studies on real-world experiences using such methods. Rapid tests offer a significantly shorter feedback loop on the effectiveness of the controls. This study involved a complex of five factories, three of which had a history of Legionella contamination in their cooling water distribution system. Multiple sampling locations were utilised to take monthly water samples over 39 months to analyse for Legionella by both culture and quantitative polymerase chain reaction (qPCR). Routine monitoring gave no positive Legionella results by culture (n = 330); however, samples were frequently (68%) positive by qPCR for Legionella spp. (n = 1564). Legionella spp. qPCR assay was thus found to be a good indicator of cooling tower system health and suitable as a routine monitoring tool. An in-house qPCR limit of 5000 genomic units (GU)/L Legionella spp. was established to trigger investigation and remedial action. This approach facilitated swift remedial action to prevent Legionella proliferation to levels that may represent a public health risk. Cooling tower operators may have to set their own action levels for their own systems; however, in this study, 5000 GU/L was deemed appropriate and pragmatic.
- 17 March 2021
- Published by MDPI AG in Microorganisms
- Vol. 9 (3) , 615
Open AccessRapid Testing and Interventions to Control Legionella Proliferation following a Legionnaires’ Disease Outbreak Associated with Cooling Towers
Most literature to date on the use of rapid Legionella tests have compared different sampling and analytical techniques, with few studies on real-world experiences using such methods. Rapid tests offer a significantly shorter feedback loop on the effectiveness of the controls. This study involved a complex of five factories, three of which had a history of Legionella contamination in their cooling water distribution system. Multiple sampling locations were utilised to take monthly water samples over 39 months to analyse for Legionella by both culture and quantitative polymerase chain reaction (qPCR). Routine monitoring gave no positive Legionella results by culture (n = 330); however, samples were frequently (68%) positive by qPCR for Legionella spp. (n = 1564). Legionella spp. qPCR assay was thus found to be a good indicator of cooling tower system health and suitable as a routine monitoring tool. An in-house qPCR limit of 5000 genomic units (GU)/L Legionella spp. was established to trigger investigation and remedial action. This approach facilitated swift remedial action to prevent Legionella proliferation to levels that may represent a public health risk. Cooling tower operators may have to set their own action levels for their own systems; however, in this study, 5000 GU/L was deemed appropriate and pragmatic.
- Open Access
- 1 March 2020
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 224, 113425
Legionella risk in evaporative cooling systems and underlying causes of associated breaches in health and safety compliance
- 1 March 2020
- Published by Elsevier in International Journal of Hygiene and Environmental Health
- Vol. 224, 113425
Open AccessLegionella risk in evaporative cooling systems and underlying causes of associated breaches in health and safety compliance