Hussien Abid Ali Bakir Mraity
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hussien Abid Ali Bakir Mraity has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Peter Hogg
University of Salford, United Kingdom
5 shared publications A. England
University of Salford, School of Health Sciences, Salford, United Kingdom
4 shared publications- Ali Abid Abojassim
University of Kufa
4 shared publications - Andrew England
Discipline of Medical Imaging and Radiation Therapy, School of Medicine and Health University College Cork Cork Ireland
2 shared publications P. Hogg
University of Salford, School of Health Sciences, Salford, United Kingdom; Department of Radiography, Karolinska Institute, Stockholm, Sweden
2 shared publications- A. Aslam1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Iraqi Journal of Physics in Iraqi Journal of Physics
- Vol. 24 (3) , 1-11
Patient Dosimetry Assessment During Lateral Cervical and Lumbar Spine Radiography in Selected Hospitals and Clinics in Al-Najaf, Iraq
Radiographic examinations of the cervical and lumbar spine are common diagnostic tests that can involve relatively high radiation exposure for the patient, particularly in lateral projections. The objective of this study was to evaluate the Entrance Surface Dose (ESD) in adult patients during lateral radiographic imaging of the cervical and lumbar spine and to benchmark the findings against internationally published data. A prospective survey was conducted in six radiographic facilities, comprising three governmental hospitals and three private clinics. A total of 221 adult patients were included, comprising 107 cervical spine LAT examinations and 114 lumbar spine LAT examinations. The exposure parameters, tube potential (kVp), tube current (mAs), and source-image-distance (SID), as well as patient data, were recorded. The ESD was estimated using the Edmonds dosimetric model and assuming a backscatter factor of 1.35. Mean ESD values ranged from 0.26 to 0.80 mGy for cervical spine LAT examinations and from 1.45 to 4.30 mGy for lumbar spine LAT examinations, with overall mean values of 0.52 mGy and 3.48 mGy, respectively. Lumbar spine examinations consistently yielded higher ESD values than the cervical spine examinations due to the greater anatomical thickness and X-ray attenuation. Furthermore, ESD values were significantly higher for lumbar spine LAT examinations performed in private clinics than in governmental hospitals (p < 0.001). The obtained ESD values were generally within internationally reported ranges. These results highlight the need for standardized protocols, quality control, and local diagnostic reference levels (LDRLs) for providing optimal patient protection.
- 1 September 2026
- Published by Iraqi Journal of Physics in Iraqi Journal of Physics
- Vol. 24 (3) , 1-11
Open AccessPatient Dosimetry Assessment During Lateral Cervical and Lumbar Spine Radiography in Selected Hospitals and Clinics in Al-Najaf, Iraq
Radiographic examinations of the cervical and lumbar spine are common diagnostic tests that can involve relatively high radiation exposure for the patient, particularly in lateral projections. The objective of this study was to evaluate the Entrance Surface Dose (ESD) in adult patients during lateral radiographic imaging of the cervical and lumbar spine and to benchmark the findings against internationally published data. A prospective survey was conducted in six radiographic facilities, comprising three governmental hospitals and three private clinics. A total of 221 adult patients were included, comprising 107 cervical spine LAT examinations and 114 lumbar spine LAT examinations. The exposure parameters, tube potential (kVp), tube current (mAs), and source-image-distance (SID), as well as patient data, were recorded. The ESD was estimated using the Edmonds dosimetric model and assuming a backscatter factor of 1.35. Mean ESD values ranged from 0.26 to 0.80 mGy for cervical spine LAT examinations and from 1.45 to 4.30 mGy for lumbar spine LAT examinations, with overall mean values of 0.52 mGy and 3.48 mGy, respectively. Lumbar spine examinations consistently yielded higher ESD values than the cervical spine examinations due to the greater anatomical thickness and X-ray attenuation. Furthermore, ESD values were significantly higher for lumbar spine LAT examinations performed in private clinics than in governmental hospitals (p < 0.001). The obtained ESD values were generally within internationally reported ranges. These results highlight the need for standardized protocols, quality control, and local diagnostic reference levels (LDRLs) for providing optimal patient protection.
- Open Access
- 29 July 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (8)
Assessment of 6MV flattening filter free (FFF) beam commissioning parameters for Versa HD and TrueBeam: A comparison study
Background: Flattening filter‐free (FFF) beams are increasingly deployed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS). The Elekta Versa HD (VHD) and Varian TrueBeam (TB) are the two most widely used FFF‐capable platforms; however, no prior study has compared their 6 MV FFF commissioning parameters under fully equipment‐equivalent conditions. Purpose: To quantify the dosimetric differences between the Elekta VHD and Varian TB 6 MV FFF platforms under equipment‐equivalent conditions and to assess their translation into patient treatment plan parameters. Methods: Percentage depth doses (PDDs), lateral beam profiles, and output factors (OFs) were acquired using an identical‐model IBA SMARTSCAN three‐dimensional water tank, a unified detector set (IBA RAZOR for small fields; CC13 for standard fields), and a fixed source‐to‐surface distance of 90 cm for both platforms, in conformance with AAPM TG‐45, AAPM TG‐106, and IAEA TRS‐483. A treatment planning translation study was performed in the Monaco TPS using the IBA IMRT phantom, with 3D‐CRT plans generated for four spherical targets (1, 3, 6, and 12 cm diameter) on both beam models. Results: VHD demonstrated consistently deeper beam penetration, with R50 exceeding TB by a mean of 1.753 ± 0.048 cm across all field sizes ( t (9) = 36.34, p < 0.001, Cohen's d = 11.49, 95% CI [1.643, 1.862] cm). TB delivered significantly higher surface doses than VHD (mean Ds: 63.64 ± 5.77% vs. 48.78 ± 7.72%; p = 0.002, | r | = 1.000). At 10 cm depth, VHD showed a higher percentage depth dose (mean difference = 5.005 ± 0.352%; t (9) = 14.22, p < 0.001, d = 4.498). The Unflatness conversion index (UCI) was strongly correlated with field size ( r = 0.916, p = 0.001) and statistically independent of measurement depth ( p = 0.292). At the plan level, TB required 5.9–17.6% more monitor units (MU) than VHD across all target sizes, with the differential diminishing as target diameter increased. Surface dose differences were preserved across all four targets (TB − VHD: 15.9–31.1%). Both the homogeneity index and gradient index reversed direction between the 1 cm target (VHD superior) and targets of 3 cm and larger (TB superior), consistent with the field‐size dependence of UCI. Conclusion: A harmonized, equipment‐equivalent measurement approach demonstrated systematic differences between VHD and TB FFF beams in penetration, surface dose, and field‐size‐dependent unflatness. Treatment planning study across four target sizes (1–12 cm) showed these differences propagate to plan‐level parameters in a target‐size‐dependent manner, with VHD advantageous for small targets and TB for larger ones. The UCI, depth‐independent and strongly correlated with field size ( r = 0.916), provides a simple cross‐platform unflatness comparison tool supporting machine‐specific planning strategies in multi‐platform clinical settings.
- 29 July 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (8)
Open AccessAssessment of 6MV flattening filter free (FFF) beam commissioning parameters for Versa HD and TrueBeam: A comparison study
Background: Flattening filter‐free (FFF) beams are increasingly deployed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS). The Elekta Versa HD (VHD) and Varian TrueBeam (TB) are the two most widely used FFF‐capable platforms; however, no prior study has compared their 6 MV FFF commissioning parameters under fully equipment‐equivalent conditions. Purpose: To quantify the dosimetric differences between the Elekta VHD and Varian TB 6 MV FFF platforms under equipment‐equivalent conditions and to assess their translation into patient treatment plan parameters. Methods: Percentage depth doses (PDDs), lateral beam profiles, and output factors (OFs) were acquired using an identical‐model IBA SMARTSCAN three‐dimensional water tank, a unified detector set (IBA RAZOR for small fields; CC13 for standard fields), and a fixed source‐to‐surface distance of 90 cm for both platforms, in conformance with AAPM TG‐45, AAPM TG‐106, and IAEA TRS‐483. A treatment planning translation study was performed in the Monaco TPS using the IBA IMRT phantom, with 3D‐CRT plans generated for four spherical targets (1, 3, 6, and 12 cm diameter) on both beam models. Results: VHD demonstrated consistently deeper beam penetration, with R50 exceeding TB by a mean of 1.753 ± 0.048 cm across all field sizes ( t (9) = 36.34, p < 0.001, Cohen's d = 11.49, 95% CI [1.643, 1.862] cm). TB delivered significantly higher surface doses than VHD (mean Ds: 63.64 ± 5.77% vs. 48.78 ± 7.72%; p = 0.002, | r | = 1.000). At 10 cm depth, VHD showed a higher percentage depth dose (mean difference = 5.005 ± 0.352%; t (9) = 14.22, p < 0.001, d = 4.498). The Unflatness conversion index (UCI) was strongly correlated with field size ( r = 0.916, p = 0.001) and statistically independent of measurement depth ( p = 0.292). At the plan level, TB required 5.9–17.6% more monitor units (MU) than VHD across all target sizes, with the differential diminishing as target diameter increased. Surface dose differences were preserved across all four targets (TB − VHD: 15.9–31.1%). Both the homogeneity index and gradient index reversed direction between the 1 cm target (VHD superior) and targets of 3 cm and larger (TB superior), consistent with the field‐size dependence of UCI. Conclusion: A harmonized, equipment‐equivalent measurement approach demonstrated systematic differences between VHD and TB FFF beams in penetration, surface dose, and field‐size‐dependent unflatness. Treatment planning study across four target sizes (1–12 cm) showed these differences propagate to plan‐level parameters in a target‐size‐dependent manner, with VHD advantageous for small targets and TB for larger ones. The UCI, depth‐independent and strongly correlated with field size ( r = 0.916), provides a simple cross‐platform unflatness comparison tool supporting machine‐specific planning strategies in multi‐platform clinical settings.
- Open Access
- 1 June 2026
- Published by KEAI Publishing in Nuclear Analysis
Background Radiation of Building Materials (Raw and Final) in Al-Najaf Governorate, Iraq
- 1 June 2026
- Published by KEAI Publishing in Nuclear Analysis
Open AccessBackground Radiation of Building Materials (Raw and Final) in Al-Najaf Governorate, Iraq
- Open Access
- 30 March 2026
- Published by University of Baghdad College of Science in Iraqi Journal of Science
- p. 1391-1398
Investigation of Cadmium, Lead, and Mercury Levels in the Urine of Renal Stone Patients in Najaf Governorate of Iraq
This study aims to determine the levels of cadmium (Cd), lead (Pb), and mercury (Hg) in the urine of renal stone patients and a healthy control group in the Najaf Governorate of Iraq using Atomic absorption spectrometry (AAS). The study included 20 renal stone patients and 20 healthy individuals as a control group. Both groups consisted of 10 women and 10 men. The results demonstrated that there was a significant difference (p <0.001) in the levels of (Cd, Pb, and Hg) in the urine of renal stone patients compared with the control group. Also, there was a statistically significant difference in Pb and Hg levels in the urine of females, which were seen to be more than that of males (p < 0.005). The difference was statistically significant p < 0.001, in the Receiver Operator Characteristic (ROC) curve analysis for levels of Cd, Pb, and Hg in urine, which showed a high area under the ROC curve (AUC) values of 0.978,1.000, 1.000, respectively. The high levels of cadmium, lead, and mercury in urine may affect kidney function and impose certain toxic issues for the kidney and can be considered as a potential factor for the occurrence of renal stones.
- 30 March 2026
- Published by University of Baghdad College of Science in Iraqi Journal of Science
- p. 1391-1398
Open AccessInvestigation of Cadmium, Lead, and Mercury Levels in the Urine of Renal Stone Patients in Najaf Governorate of Iraq
This study aims to determine the levels of cadmium (Cd), lead (Pb), and mercury (Hg) in the urine of renal stone patients and a healthy control group in the Najaf Governorate of Iraq using Atomic absorption spectrometry (AAS). The study included 20 renal stone patients and 20 healthy individuals as a control group. Both groups consisted of 10 women and 10 men. The results demonstrated that there was a significant difference (p <0.001) in the levels of (Cd, Pb, and Hg) in the urine of renal stone patients compared with the control group. Also, there was a statistically significant difference in Pb and Hg levels in the urine of females, which were seen to be more than that of males (p < 0.005). The difference was statistically significant p < 0.001, in the Receiver Operator Characteristic (ROC) curve analysis for levels of Cd, Pb, and Hg in urine, which showed a high area under the ROC curve (AUC) values of 0.978,1.000, 1.000, respectively. The high levels of cadmium, lead, and mercury in urine may affect kidney function and impose certain toxic issues for the kidney and can be considered as a potential factor for the occurrence of renal stones.
- 30 July 2022
- Published by Online Journal of Animal and Feed Research in Online Journal of Animal and Feed Research
Determining the radium concentration in vegetables and fruits in Al-Najaf, Iraq
Amount of pollution radiation in foodstuffs and feedstuffs are very necessary to measure because it is a direct contact with human and animal health. Therefore, the present investigation is useful for the health and environmental data base. The study included measurement of effective radium-226 content (CRa) in some chosen samples of vegetables and fruits (local and imported) in Najaf governorate. The CRa were measured in samples of vegetables and fruits using Solid State Nuclear Track Detectors (LR-115 Type II). Also, the annual effective dose (AED) associated with the exposure due to annual intake of 226Ra were calculated from ingestion of vegetables and fruits samples for adults. The results were revealed that the average value of CRa in vegetables and fruits samples in the present study was 3.98±1.08 Bq/kg and 1.73±0.11 Bq/kg, respectively. While, the average of AED (mSv/y) for vegetables and fruits samples was 0.067±0.018 and 0.082±0.005, respectively. Also, the results showed that the average value of AED from fruits consumption is larger than in vegetables, but the result is not significant. All results of the CRa and AED of the studied samples had been compared with the worldwide reported value (median). Accordingly, it was found that all findings were lower than that of the recommended limits of the UNSCEAR 2000. Finally, based on present investigations, no health risk expected when considering eating vegetables and fruits of Al-Najaf of Iraq. Keywords: Alpha emitters, Food contamination, Radium-226, Herbal samples, Al-Najaf.
- 30 July 2022
- Published by Online Journal of Animal and Feed Research in Online Journal of Animal and Feed Research
Determining the radium concentration in vegetables and fruits in Al-Najaf, Iraq
Amount of pollution radiation in foodstuffs and feedstuffs are very necessary to measure because it is a direct contact with human and animal health. Therefore, the present investigation is useful for the health and environmental data base. The study included measurement of effective radium-226 content (CRa) in some chosen samples of vegetables and fruits (local and imported) in Najaf governorate. The CRa were measured in samples of vegetables and fruits using Solid State Nuclear Track Detectors (LR-115 Type II). Also, the annual effective dose (AED) associated with the exposure due to annual intake of 226Ra were calculated from ingestion of vegetables and fruits samples for adults. The results were revealed that the average value of CRa in vegetables and fruits samples in the present study was 3.98±1.08 Bq/kg and 1.73±0.11 Bq/kg, respectively. While, the average of AED (mSv/y) for vegetables and fruits samples was 0.067±0.018 and 0.082±0.005, respectively. Also, the results showed that the average value of AED from fruits consumption is larger than in vegetables, but the result is not significant. All results of the CRa and AED of the studied samples had been compared with the worldwide reported value (median). Accordingly, it was found that all findings were lower than that of the recommended limits of the UNSCEAR 2000. Finally, based on present investigations, no health risk expected when considering eating vegetables and fruits of Al-Najaf of Iraq. Keywords: Alpha emitters, Food contamination, Radium-226, Herbal samples, Al-Najaf.
- 1 May 2020
- Published by Elsevier in Radiography
- Vol. 26 (2) , e103-e108
Can the anode heel effect be used to optimise radiation dose and image quality for AP pelvis radiography?
- 1 May 2020
- Published by Elsevier in Radiography
- Vol. 26 (2) , e103-e108
Can the anode heel effect be used to optimise radiation dose and image quality for AP pelvis radiography?
- 1 January 2020
- Published by Scholit Publishing LLC
- Vol. 106 (4)
Estimation of the Effective Dose for Patients Undergoing PA Chest X-Ray Examination in Selected Hospitals of Al Najaf Governorate-Iraq
The demand for utilizing medical X-ray examinations becomes increasingly high worldwide. Using ionizing radiation for diagnostic purposes has been ranked as the second main source of human exposure after the natural sources of radioactivity.
- 1 January 2020
- Published by Scholit Publishing LLC
- Vol. 106 (4)
Estimation of the Effective Dose for Patients Undergoing PA Chest X-Ray Examination in Selected Hospitals of Al Najaf Governorate-Iraq
The demand for utilizing medical X-ray examinations becomes increasingly high worldwide. Using ionizing radiation for diagnostic purposes has been ranked as the second main source of human exposure after the natural sources of radioactivity.
- Open Access
- 25 September 2017
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Nuclear Physics and Atomic Energy
- Vol. 18 (3) , 276-286
Estimation of the excess lifetime cancer risk from radon exposure in some buildings of Kufa Technical Institute, Iraq
- 25 September 2017
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Nuclear Physics and Atomic Energy
- Vol. 18 (3) , 276-286
Open AccessEstimation of the excess lifetime cancer risk from radon exposure in some buildings of Kufa Technical Institute, Iraq
- 27 October 2016
- Published by Elsevier in Radiography
- Vol. 23 (1) , 80-81
Gonad dose in AP pelvis radiography: Impact of anode heel orientation
- 27 October 2016
- Published by Elsevier in Radiography
- Vol. 23 (1) , 80-81
Gonad dose in AP pelvis radiography: Impact of anode heel orientation
- 29 July 2016
- Published by IWA Publishing in Water Supply
- Vol. 17 (1) , 206-211
Radon levels in different types of bottled drinking water and carbonated drinks in Iraqi markets
In the present work, radon concentration was measured for different types of bottled drinking water and carbonated drink samples that are available in Iraqi markets. Radon measurements were carried out using a RAD-7 electronic radon detector. Annual effective dose was also calculated. The measured radon concentration in samples of bottled drinking water ranged from 0.0354 to 0.248 Bq/l with a mean value of 0.11265 Bq/l and the measured radon concentration in the samples of the carbonated drinks lay between 0.0354 and 0.283 Bq/l with a mean value of 0.1418 Bq/l. The mean values of the effective dose in all samples of bottled drinking water and carbonated drinks were found to be 0.410844 and 1.022 μSv/y respectively. The results of this work revealed that the radon concentrations were lower than the recommended limits indicated by the World Health Organization and by the regulatory bodies of the European Union.
- 29 July 2016
- Published by IWA Publishing in Water Supply
- Vol. 17 (1) , 206-211
Radon levels in different types of bottled drinking water and carbonated drinks in Iraqi markets
In the present work, radon concentration was measured for different types of bottled drinking water and carbonated drink samples that are available in Iraqi markets. Radon measurements were carried out using a RAD-7 electronic radon detector. Annual effective dose was also calculated. The measured radon concentration in samples of bottled drinking water ranged from 0.0354 to 0.248 Bq/l with a mean value of 0.11265 Bq/l and the measured radon concentration in the samples of the carbonated drinks lay between 0.0354 and 0.283 Bq/l with a mean value of 0.1418 Bq/l. The mean values of the effective dose in all samples of bottled drinking water and carbonated drinks were found to be 0.410844 and 1.022 μSv/y respectively. The results of this work revealed that the radon concentrations were lower than the recommended limits indicated by the World Health Organization and by the regulatory bodies of the European Union.