LFLaila Gonzales Freire

Laila Gonzales Freire

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Laila Gonzales Freire has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    VIDA XR: Mixed Reality Tool for teaching anatomy to dental students

    by Izabela Marina Ferreira Da Silva, Emilly da Silva Arcanjo, Lucas Carvalho Ramos, Mary Caroline Skelton Macedo, Laila Gonzales Freire, Thalya Fernanda Horsth Maltarollo, Romero Tori, Ricardo Nakamura

    Teaching dental anatomy faces challenges related to ethical concerns, cost of materials and quality of artificial representations. Virtual and augmented reality technologies have been explored for education and training in healthcare for the same motivations. In this paper we present a novel mixed reality tool that allows dental students to visualize and manipulate 3D models of tooth surface and tooth root, generated from microtomography scans. The development process by a multidisciplinary team is described, followed by results from performance evaluation and assessment by an expert panel. Performance was within the guidelines for applications in the adopted head-mounted device, and expert assessment was positive regarding its usefulness and ease of use. Future work includes assessing the tool's pedagogical effectiveness in anatomy classes.

  • Open Access

    Challenges in long-oval canal cleaning: effects of instrumentation kinematics and ultrasonic irrigation

    by Sandra Soares Kühne Busquim, Laila Gonzales Freire, Iandara de Lima Scardini, Marcelo dos Santos

    The present study aimed to evaluate, using micro-CT imaging, the preparation of long-oval root canals performed by Twisted File Adaptive (TFA) and Reciproc (RC) instruments and the cleaning efficacy of final ultrasonic irrigation (UI) using a correlative scanning electron microscopic (SEM) approach. Distal long-oval canals of thirty-eight lower molars were divided into two groups (n=19): TFA and RC groups. Each specimen underwent three scans: pre- and post-instrumentation and post-UI, and changes in volume, non-prepared surfaces, and accumulated hard-tissue debris (AHTD) were measured. Then, root canals were halved at the apical third and analyzed under SEM for smear layer (SL) evaluation. Mann-Whitney and Kruskal-Wallis tests were used for statistical analysis (p0.05). Final UI led to a notable reduction in AHTD (60-70%), except in the apical third. Qualitatively, SEM analysis revealed non-uniform dentin remnants covering the canal walls, particularly prominent in the RC group. The data analysis determined a strong correlation between AHTD and SEM evaluation. In conclusion, neither system achieved complete preparation of long-oval root canal walls, and the final UI reduced AHTD. The AHTD observed by micro-CT was related to the presence of SL evaluated by SEM.

  • Open Access

    Root canal curvature influences uncontrolled removal of dentin and cleaning efficacy after ultrasonic activation

    by Hermano Camelo Paiva, Elaine Faga Iglecias, Laila Gonzales Freire, George Táccio de Miranda Candeiro, Basílio Rodrigues Vieira, Frederico Barbosa de Sousa, Giulio Gavini

    This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p 0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


  • Open Access

    Using manual versus mechanized glide path instruments and ProTaper Gold versus ProTaper Next systems in curved canals: micro-CT study

    by Breno Nappi Ventura, Giulio Gavini, Elaine Faga Iglecias, Laila Gonzales Freire, Celso Luiz Caldeira

    The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.


  • Open Access

    Surface profile of different heat-treated nickel-titanium files before and after root canal preparation

    by Iandara de Lima Scardini, Denise Maria Zezell, Juliana Lisboa Couto Marques, Laila Gonzales Freire, Marcelo dos Santos

    The aim of this study was to evaluate surface wear, presence of microcracks and surface irregularities of WaveOne (WO) and WaveOne Gold (WOG) instruments before and after multiple uses. Eight Primary instruments of the WO and WOG systems were evaluated, each one was used to prepare six mesial canals of extracted human mandibular molars. The surface of the instruments was evaluated before use (T0), after instrumentation of three (T1) and six (T2) root canals. Surface wear was analyzed using a three-dimensional optical profiler and the presence of microcracks and surface irregularities were evaluated using a tabletop scanning electron microscopy. The Friedman test was used to assess surface wear and Kruskal-Wallis test to evaluate the presence of microcracks and surface irregularities, with a 5% significance level. There was a significant increase in wear in both groups at T2, compared to T0 (p=0.0003). The surface wear after instrumentation of six canals (T2-T0) was statistically greater in the WOG group, than in the WO group (p=0.02), where the presence of microcracks was significantly greater and increased after multiple uses (p<0.05). The presence of surface irregularities in the cutting blade before and after use was statistically greater in the WOG group than WO group (p<0.05). Wear of the cutting blade, microcracks and surface irregularities were observed on the surface topography of all the instruments after multiple uses. These surface changes may affect the cutting efficiency of WOG files and increase the risk of fracture of WO files.


  • Open Access

    Evaluation of Apically Extruded Debris during Root Canal Retreatment Using ProTaper Next and Reciproc in Severely Curved Canals

    by Giselle Nevares, Kaline Romeiro, Diana Albuquerque, Felipe Xavier, Howard Fogel, Laila Freire, Rodrigo Cunha

    To compare the apical extrusion of debris produced during root obturating material removal from severely curved root canals using either Reciproc (REC) or ProTaper Next (PTN) systems. Twenty-six mesial canals of lower molars were instrumented, filled and allocated into two groups (n=13). Micro-computed tomographic images were performed to determine the root canal configuration (Vertucci’s type IV) and initial volume of obturation. One Eppendorf tube was assigned per canal and weighed (10-4g) before and after removal of the obturating material. The difference between the initial and final weights was calculated and statistically evaluated. Apical extrusion of debris was confirmed in all samples, and the mean amount of apical extrusion was similar between both groups (0.061±0.014 g in PTN vs. 0.065±0.016 g in REC samples) (P<0.05). Both systems caused apical extrusion of debris with no differences between PTN and REC systems.


  • Counterclockwise or clockwise reciprocating motion for oval root canal preparation: a micro‐CT analysis

    by C. G. Espir, C. A. Nascimento‐Mendes, J. M. Guerreiro‐Tanomaru, L. G. Freire, G. Gavini, M. Tanomaru‐Filho

    Aim: To evaluate oval root canal preparation using one or two instruments in counterclockwise or clockwise reciprocating motion.Methodology: The radiographic diameter of mandibular human incisors was evaluated, and oval canals were selected (2 ≤ Diameter Ratio ≤ 4). Fifty‐seven teeth were assigned to root canal preparation (n = 19): Reciproc 40 (R40) in a counterclockwise reciprocating motion; Mtwo size 40, .06 taper (M 40.06) in a clockwise reciprocating motion or Mtwo size 20, .06 taper and size 40, .06 taper (M 20/40.06) in a clockwise reciprocating motion. Mtwo instruments were coupled to an ENDO DUAL motor, turning 150° clockwise and 30° counterclockwise. Scanning was performed before and after root canal preparation using a SkyScan 1176 micro‐computed tomography. Volume, percentage of debris and percentage of uninstrumented surface were analysed in the entire root canal and in each third of the canal. Data were compared using anova and Tukey's tests or Kruskal–Wallis and Dunn tests.Results: The Reciproc and Mtwo systems using different kinematics were associated with a similar increase in root canal volume. Additionally, both system had similar percentage of uninstrumented surface (P > 0.05). Mtwo size 20, .06 taper and size 40, .06 taper was associated with significantly lower debris (P < 0.05) in the middle third (0.56%) when compared to R40 (1.31%) and M size 40, .06 taper (1.54%).Conclusions: The conventional reciprocation motion for R40 and the clockwise reciprocation motion for Mtwo resulted in similar root canal preparations. Less remaining debris was present in the middle third when two instruments with different diameters were used.


  • Presence of Voids after Continuous Wave of Condensation and Single-cone Obturation in Mandibular Molars: A Micro-computed Tomography Analysis

    by Elaine Faga Iglecias, Laila Gonzales Freire, George Táccio de Miranda Candeiro, Marcelo dos Santos, João Humberto Antoniazzi, Giulio Gavini


  • Effect of finishing instrumentation using NiTi hand files on volume, surface area and uninstrumented surfaces in C‐shaped root canal systems

    by P. Amoroso‐Silva, M. P. Alcalde, M. A. Hungaro Duarte, G. De‐Deus, R. Ordinola‐Zapata, L. G. Freire, B. C. Cavenago, I. G. De Moraes

    Aim: To assess the effect of 90°‐oscillatory instrumentation with hand files on several morphological parameters (volume, surface area and uninstrumented surface) in C‐shaped root canals after instrumentation using a single‐file reciprocation system (Reciproc; VDW, Munich, Germany) and a Self‐Adjusting File System (SAF; ReDent Nova, Ra'anana, Israel).Methodology: Twenty mandibular second molars with C‐shaped canals and C1 canal configurations were divided into two groups (n = 10) and instrumented with Reciproc and SAF instruments. A size 30 NiTi hand K‐file attached to a 90°‐oscillatory motion handpiece was used as final instrumentation in both groups. The specimens were scanned using micro‐computed tomography after all procedures. Volume, surface area increase and uninstrumented root canal surface were analysed using CTAn software (Bruker‐microCT, Kontich, Belgium). Also, the uninstrumented root canal surface was calculated for each canal third. All values were compared between groups using the Mann–Whitney test and within groups using the Wilcoxon's signed‐rank test.Results: Instrumentation with Reciproc significantly increased canal volume compared with instrumentation with SAF. Additionally, the canal volumes were significantly increased after 90°‐oscillatory instrumentation (between and within group comparison; (P < 0.05)). Regarding the increase in surface area after all instrumentation protocols, statistical analysis only revealed significant differences in the within groups comparison (P < 0.05). Reciproc and SAF instrumentation yielded an uninstrumented root canal surface of 28% and 34%, respectively, which was not significantly different (P > 0.05). Final oscillatory instrumentation significantly reduced the uninstrumented root canal surface from 28% to 9% (Reciproc) and from 34% to 15% (SAF; P < 0.05). The apical and middle thirds exhibited larger uninstrumented root canal surfaces after the first instrumentation that was significantly reduced after oscillatory instrumentation (P < 0.05).Conclusions: The Reciproc and SAF system were associated with similar morphological parameters after instrumentation of mandibular second molars with C‐shaped canals except for a higher canal volume increase in the Reciproc group compared to the SAF. Furthermore, the final use of 90°‐oscillatory instrumentation using NiTi hand files significantly decreased the uninstrumented canal walls that remained after Reciproc and SAF instrumentation.


  • Open Access

    Ions Release and pH of Calcium Hydroxide-, Chlorhexidine- and Bioactive Glass-Based Endodontic Medicaments

    by Ceci Nunes Carvalho, Laila Gonzales Freire, Alexandre Pinheiro Lima de Carvalho, Marco Antonio Húngaro Duarte, José Bauer, Giulio Gavini

    This study evaluated pH and release of calcium, sodium and phosphate ions from different medications in human dentin. Fifty premolars were prepared and randomly divided into groups: (CHX) - 2% chlorhexidine gel; (CHX + CH) - CHX + calcium hydroxide PA; (CH) - CH + propylene glycol 600; (NPBG) - experimental niobium phosphate bioactive glass + distilled water; (BG) - bioactive glass (Bio-Gran) + distilled water. The specimens were immersed in deionized water and the pH variations were measured. The quantification of ions in the solutions was made by inductively coupled plasma - atomic emission spectroscopy (ICP/AES) at 10 min, 24 h, 7, 14, 21 and 30 days. The results were analyzed by ANOVA and Tukey`s test, with a significance level of 5%. CH had the highest level of calcium ions release at 30 days, while CHX and BG released more sodium ions. BG, NPBG and CHX released a higher amount of phosphate ions. The pH of CH was significantly higher compared with the other groups. CH favored the greatest increase of pH and calcium ions release. The bioactive glasses released more sodium and phosphate ions and presented an alkaline pH immediately and after 30 days.