Denis Wypysek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Denis Wypysek has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Wessling
Chemical Process Engineering RWTH Aachen University Aachen Germany
9 shared publications - Deniz Rall
DWI-Leibniz Institute for Interactive Materials Forckenbeckstr. 50 52074 Aachen Germany
3 shared publications Martin Wiese
3 shared publications- Anna Kalde
RWTH Aachen University Aachener Verfahrenstechnik ‐ Chemical Process Engineering Forckenbeckstr. 51 52074 Aachen Germany
2 shared publications - Maik Tepper
Chemical Process Engineering AVT.CVT RWTH Aachen University Aachen Germany
2 shared publications - Alex Jarauta
University of Alberta
1 shared publication
Latest Publications
- Open Access
- 15 September 2026
- Published by Elsevier in Journal of Membrane Science
- Vol. 759
Hydraulic coupling and flow redistribution in hollow fiber membrane modules with blocked fibers
- 15 September 2026
- Published by Elsevier in Journal of Membrane Science
- Vol. 759
Open AccessHydraulic coupling and flow redistribution in hollow fiber membrane modules with blocked fibers
- 7 February 2023
- Published by Elsevier in Journal of Membrane Science
- Vol. 673
Helical-Ridge-Membranes from PVDF for enhanced gas–liquid mass transfer
- 7 February 2023
- Published by Elsevier in Journal of Membrane Science
- Vol. 673
Helical-Ridge-Membranes from PVDF for enhanced gas–liquid mass transfer
- Open Access
- 29 December 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Discrepancy of particle passage in 101 mask batches during the first year of the Covid-19 pandemic in Germany
During the first wave of Covid-19 infections in Germany in April 2020, clinics reported a shortage of filtering face masks with aerosol retention> 94% (FFP2 & 3, KN95, N95). Companies all over the world increased their production capacities, but quality control of once-certified materials and masks came up short. To help identify falsely labeled masks and ensure safe protection equipment, we tested 101 different batches of masks in 993 measurements with a self-made setup based on DIN standards. An aerosol generator provided a NaCl test aerosol which was applied to the mask. A laser aerosol spectrometer measured the aerosol concentration in a range from 90 to 500 nm to quantify the masks’ retention. Of 101 tested mask batches, only 31 batches kept what their label promised. Especially in the initial phase of the pandemic in Germany, we observed fluctuating mask qualities. Many batches show very high variability in aerosol retention. In addition, by measuring with a laser aerosol spectrometer, we were able to show that not all masks filter small and large particles equally well. In this study we demonstrate how important internal and independent quality controls are, especially in times of need and shortage of personal protection equipment.
- 29 December 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Open AccessDiscrepancy of particle passage in 101 mask batches during the first year of the Covid-19 pandemic in Germany
During the first wave of Covid-19 infections in Germany in April 2020, clinics reported a shortage of filtering face masks with aerosol retention> 94% (FFP2 & 3, KN95, N95). Companies all over the world increased their production capacities, but quality control of once-certified materials and masks came up short. To help identify falsely labeled masks and ensure safe protection equipment, we tested 101 different batches of masks in 993 measurements with a self-made setup based on DIN standards. An aerosol generator provided a NaCl test aerosol which was applied to the mask. A laser aerosol spectrometer measured the aerosol concentration in a range from 90 to 500 nm to quantify the masks’ retention. Of 101 tested mask batches, only 31 batches kept what their label promised. Especially in the initial phase of the pandemic in Germany, we observed fluctuating mask qualities. Many batches show very high variability in aerosol retention. In addition, by measuring with a laser aerosol spectrometer, we were able to show that not all masks filter small and large particles equally well. In this study we demonstrate how important internal and independent quality controls are, especially in times of need and shortage of personal protection equipment.
- 1 November 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 637
A mini-module with built-in spacers for high-throughput ultrafiltration
- 1 November 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 637
A mini-module with built-in spacers for high-throughput ultrafiltration
- 1 October 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 636
How does porosity heterogeneity affect the transport properties of multibore filtration membranes?
- 1 October 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 636
How does porosity heterogeneity affect the transport properties of multibore filtration membranes?
- 1 March 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 622
In-situ investigation of wetting patterns in polymeric multibore membranes via magnetic resonance imaging
- 1 March 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 622
In-situ investigation of wetting patterns in polymeric multibore membranes via magnetic resonance imaging
- 1 August 2019
- Published by Elsevier in Journal of Membrane Science
- Vol. 584, 254-267
Shell and lumen side flow and pressure communication during permeation and filtration in a multibore polymer membrane module
- 1 August 2019
- Published by Elsevier in Journal of Membrane Science
- Vol. 584, 254-267
Shell and lumen side flow and pressure communication during permeation and filtration in a multibore polymer membrane module
- 1 January 2019
- Published by Elsevier in Journal of Membrane Science
- Vol. 569, 7-16
Fouling minimization at membranes having a 3D surface topology with microgels as soft model colloids
- 1 January 2019
- Published by Elsevier in Journal of Membrane Science
- Vol. 569, 7-16
Fouling minimization at membranes having a 3D surface topology with microgels as soft model colloids
- 18 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (3) , 821-830
Noninvasive Quantification of Cell Density in Three-Dimensional Gels by MRI
Objective: For tissue engineering, there is a need for quantitative methods to map cell density inside three-dimensional (3-D) bioreactors to assess tissue growth over time. The current cell mapping methods in 2-D cultures are based on optical microscopy. However, optical methods fail in 3-D due to increased opacity of the tissue. We present an approach for measuring the density of cells embedded in a hydrogel to generate quantitative maps of cell density in a living, 3-D tissue culture sample. Methods: Quantification of cell density was obtained by calibrating the 1 H T 2 , magnetization transfer (MT) and diffusion-weighted nuclear magnetic resonance (NMR) signals to samples of known cell density. Maps of cell density were generated by weighting NMR images by these parameters post-calibration. Results: The highest sensitivity weighting arose from MT experiments, which yielded a limit of detection (LOD) of 2.5 × 10 8 cells/mL/√Hz in a 400 MHz (9.4 T) magnet. Conclusion: This mapping technique provides a noninvasive means of visualizing cell growth within optically opaque bioreactors. Significance: We anticipate that such readouts of tissue culture growth will provide valuable feedback for controlled cell growth in bioreactors.
- 18 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (3) , 821-830
Noninvasive Quantification of Cell Density in Three-Dimensional Gels by MRI
Objective: For tissue engineering, there is a need for quantitative methods to map cell density inside three-dimensional (3-D) bioreactors to assess tissue growth over time. The current cell mapping methods in 2-D cultures are based on optical microscopy. However, optical methods fail in 3-D due to increased opacity of the tissue. We present an approach for measuring the density of cells embedded in a hydrogel to generate quantitative maps of cell density in a living, 3-D tissue culture sample. Methods: Quantification of cell density was obtained by calibrating the 1 H T 2 , magnetization transfer (MT) and diffusion-weighted nuclear magnetic resonance (NMR) signals to samples of known cell density. Maps of cell density were generated by weighting NMR images by these parameters post-calibration. Results: The highest sensitivity weighting arose from MT experiments, which yielded a limit of detection (LOD) of 2.5 × 10 8 cells/mL/√Hz in a 400 MHz (9.4 T) magnet. Conclusion: This mapping technique provides a noninvasive means of visualizing cell growth within optically opaque bioreactors. Significance: We anticipate that such readouts of tissue culture growth will provide valuable feedback for controlled cell growth in bioreactors.
- 1 June 2018
- Published by Elsevier in Journal of Membrane Science
- Vol. 555, 7-19
3D-printed rotating spinnerets create membranes with a twist
- 1 June 2018
- Published by Elsevier in Journal of Membrane Science
- Vol. 555, 7-19
3D-printed rotating spinnerets create membranes with a twist