Juan José Giner Sanz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Juan José Giner Sanz has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Valentin Pérez Herranz
IEC Group, Institute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de València, Camí de Vera, s/n, 46022 Valencia, Spain
22 shared publications - Emma María Ortega
Universitat Politècnica de València
11 shared publications M. García-Gabaldón
IEC Group, ISIRYM, Universitat Politècnica de València, Camí de Vera s/n, 46022, València, P.O. Box 22012, E-46071, Spain
3 shared publications- Beatriz Garcia Fayos
Universitat Politècnica de València
2 shared publications - Belén Garcia-Gimeno2 shared publications
E. M. Ortega
IEC group, Depto. Ingeniería Química y Nuclear, Universitat Politècnica de València, 46022 Valencia, Spain
2 shared publications
Latest Publications
- 1 June 2026
- Published by IATED Academy in EDULEARN Proceedings
- Vol. 1, 1597
FROM GROUP TO INDIVIDUAL GRADES: USING TESTS TO INDIVIDUALIZE LABORATORY ASSESSMENT IN CHEMICAL ENGINEERING COURSES
- 1 June 2026
- Published by IATED Academy in EDULEARN Proceedings
- Vol. 1, 1597
FROM GROUP TO INDIVIDUAL GRADES: USING TESTS TO INDIVIDUALIZE LABORATORY ASSESSMENT IN CHEMICAL ENGINEERING COURSES
- 1 June 2026
- Published by IATED Academy in EDULEARN Proceedings
- Vol. 1, 1569
ASSESSING TEAMWORK AND LEADERSHIP AS A TRANSVERSAL COMPETENCE IN CHEMICAL ENGINEERING UNDERGRADUATE EDUCATION
- 1 June 2026
- Published by IATED Academy in EDULEARN Proceedings
- Vol. 1, 1569
ASSESSING TEAMWORK AND LEADERSHIP AS A TRANSVERSAL COMPETENCE IN CHEMICAL ENGINEERING UNDERGRADUATE EDUCATION
- Open Access
- 21 November 2025
- Published by Elsevier in Systems and Soft Computing
- Vol. 7
Deep Learning algorithm, based on convolutional neural networks, for equivalent electrical circuit recommendation for Electrochemical Impedance Spectroscopy
- 21 November 2025
- Published by Elsevier in Systems and Soft Computing
- Vol. 7
Open AccessDeep Learning algorithm, based on convolutional neural networks, for equivalent electrical circuit recommendation for Electrochemical Impedance Spectroscopy
- Open Access
- 19 May 2022
- Published by The Electrochemical Society in ECS Advances
- Vol. 1 (2) , 024501
Alkali Metal Salt Interference on the Salicylate Method for Quantifying Ammonia from Nitrogen Reduction
The salicylate method has been extensively used for quantifying ammonia in the emerging field of nitrogen (electro)fixation. Alkali metal salts are widely used as supporting electrolytes for nitrogen reduction, especially in the context of electrochemical nitrogen fixation. However, these salts are known to cause interferences on the salicylate method, introducing significant uncertainties in ammonia quantification. In this work, the interference of lithium, sodium and potassium chlorides, perchlorates and sulfates on the ammonia quantification results obtained using the salicylate method was experimentally quantified, and an empirical model was developed to capture the effect of the presence of these interferents on the ammonia quantification by the salicylate method. Based on the obtained experimental interference results, the tested interferents can be ranked from stronger interferent (i.e. lower admissible concentration) to weaker interferent: Li2SO4, KClO4, LiCl, LiClO4, K2SO4, NaClO4, NaCl, Na2SO4, KCl. The developed model can be used to assess the experimental error in ammonia quantification from nitrogen reduction, in samples containing these interferents. This model can be used to correct the interferences on the ammonia quantification, when the interferent concentration in a sample is known (or measurable).
- 19 May 2022
- Published by The Electrochemical Society in ECS Advances
- Vol. 1 (2) , 024501
Open AccessAlkali Metal Salt Interference on the Salicylate Method for Quantifying Ammonia from Nitrogen Reduction
The salicylate method has been extensively used for quantifying ammonia in the emerging field of nitrogen (electro)fixation. Alkali metal salts are widely used as supporting electrolytes for nitrogen reduction, especially in the context of electrochemical nitrogen fixation. However, these salts are known to cause interferences on the salicylate method, introducing significant uncertainties in ammonia quantification. In this work, the interference of lithium, sodium and potassium chlorides, perchlorates and sulfates on the ammonia quantification results obtained using the salicylate method was experimentally quantified, and an empirical model was developed to capture the effect of the presence of these interferents on the ammonia quantification by the salicylate method. Based on the obtained experimental interference results, the tested interferents can be ranked from stronger interferent (i.e. lower admissible concentration) to weaker interferent: Li2SO4, KClO4, LiCl, LiClO4, K2SO4, NaClO4, NaCl, Na2SO4, KCl. The developed model can be used to assess the experimental error in ammonia quantification from nitrogen reduction, in samples containing these interferents. This model can be used to correct the interferences on the ammonia quantification, when the interferent concentration in a sample is known (or measurable).
- Open Access
- 1 October 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (13) , 134519
Salicylate Method for Ammonia Quantification in Nitrogen Electroreduction Experiments: The Correction of Iron III Interference
The salicylate method is one of the ammonia quantification methods that has been extensively used in literature for quantifying ammonia in the emerging field of nitrogen (electro)fixation. The presence of iron in the sample causes a strong negative interference on the salicylate method. Today, the recommended method to deal with such interferences is the experimental correction method: the iron concentration in the sample is measured using an iron quantification method, and then the corresponding amount of iron is added to the calibration samples. The limitation of this method is that when a batch of samples presents a great iron concentration variability, a different calibration curve has to be obtained for each sample. In this work, the interference of iron III on the salicylate method was experimentally quantified, and a model was proposed to capture the effect of iron III interference on the ammonia quantification result. This model can be used to correct the iron III interferences on ammonia quantification. The great advantage of this correction method is that it only requires three experimental curves in order to correct the iron III interference in any sample provided the iron III concentration is below the total peak suppression concentration.
- 1 October 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (13) , 134519
Open AccessSalicylate Method for Ammonia Quantification in Nitrogen Electroreduction Experiments: The Correction of Iron III Interference
The salicylate method is one of the ammonia quantification methods that has been extensively used in literature for quantifying ammonia in the emerging field of nitrogen (electro)fixation. The presence of iron in the sample causes a strong negative interference on the salicylate method. Today, the recommended method to deal with such interferences is the experimental correction method: the iron concentration in the sample is measured using an iron quantification method, and then the corresponding amount of iron is added to the calibration samples. The limitation of this method is that when a batch of samples presents a great iron concentration variability, a different calibration curve has to be obtained for each sample. In this work, the interference of iron III on the salicylate method was experimentally quantified, and a model was proposed to capture the effect of iron III interference on the ammonia quantification result. This model can be used to correct the iron III interferences on ammonia quantification. The great advantage of this correction method is that it only requires three experimental curves in order to correct the iron III interference in any sample provided the iron III concentration is below the total peak suppression concentration.
- Open Access
- 28 January 2020
- Published by Universitat Politecnica de Valencia in Modelling in Science Education and Learning
- Vol. 13 (1) , 13-20
A simple Simulink® model of a conductivity system for exploring the performance of a Smith’s predictor
En este trabajo se presenta un modelo sencillo de Simulink de un sistema de control de conductividad, basado en un predictor de Smith. Este modelo tiene tres objetivos didácticos principales. En primer lugar, permite mostrar a los estudiantes cómo se puede usar una herramienta computacional para resolver problemas que requerirán una cantidad considerable de trabajo si se resolvieran analíticamente. En segundo lugar, permite presentar un ejemplo de controlador avanzado: el predictor de Smith. En último lugar, empleando este modelo los estudiantes pueden "jugar" con el sistema para estudiar el efecto de los diferentes parámetros del sistema y del controlador sobre el desempeño del sistema controlado.
- 28 January 2020
- Published by Universitat Politecnica de Valencia in Modelling in Science Education and Learning
- Vol. 13 (1) , 13-20
Open AccessA simple Simulink® model of a conductivity system for exploring the performance of a Smith’s predictor
En este trabajo se presenta un modelo sencillo de Simulink de un sistema de control de conductividad, basado en un predictor de Smith. Este modelo tiene tres objetivos didácticos principales. En primer lugar, permite mostrar a los estudiantes cómo se puede usar una herramienta computacional para resolver problemas que requerirán una cantidad considerable de trabajo si se resolvieran analíticamente. En segundo lugar, permite presentar un ejemplo de controlador avanzado: el predictor de Smith. En último lugar, empleando este modelo los estudiantes pueden "jugar" con el sistema para estudiar el efecto de los diferentes parámetros del sistema y del controlador sobre el desempeño del sistema controlado.
- 1 January 2020
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 188, 109923
Analysis of norfloxacin ecotoxicity and the relation with its degradation by means of electrochemical oxidation using different anodes
- 1 January 2020
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 188, 109923
Analysis of norfloxacin ecotoxicity and the relation with its degradation by means of electrochemical oxidation using different anodes
- 12 April 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (6) , H224-H232
Algorithm for Assessing the Convergence of a Cyclic Voltammetry to Its Limit Cycle
Cyclic voltammetry is one of today's standard electrochemical measurement techniques. What characterizes cyclic voltammetry is that potential is linearly ramped in cycles. In general, in this kind of measurements, the system tends to a stationary state, which is known as limit cycle. The common practice for assessing the voltammogram convergence is to perform a multicycle cyclic voltammetry, and visually compare the sequential cycles in order to see if there are significant changes from one cycle to the following one. The main limitation of visual comparison is its limited accuracy and its dependence on the analyst's subjectivity. In this work, an algorithm for quantitatively assessing the convergence of experimental cyclic voltammograms (CVs) was developed. The algorithm was successfully validated experimentally using two systems: it is able to determine whether the CV converged to its limit cycle, and when it converged. Moreover, the algorithm is able to quantify the measurement noise. The low computational cost of the developed algorithm allows to execute it in real time during the cyclic voltammetry measurement. In this way, it can be used in order to automate the measurement process which would decide, according to predefined convergence criteria, when to stop cycling.
- 12 April 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (6) , H224-H232
Algorithm for Assessing the Convergence of a Cyclic Voltammetry to Its Limit Cycle
Cyclic voltammetry is one of today's standard electrochemical measurement techniques. What characterizes cyclic voltammetry is that potential is linearly ramped in cycles. In general, in this kind of measurements, the system tends to a stationary state, which is known as limit cycle. The common practice for assessing the voltammogram convergence is to perform a multicycle cyclic voltammetry, and visually compare the sequential cycles in order to see if there are significant changes from one cycle to the following one. The main limitation of visual comparison is its limited accuracy and its dependence on the analyst's subjectivity. In this work, an algorithm for quantitatively assessing the convergence of experimental cyclic voltammograms (CVs) was developed. The algorithm was successfully validated experimentally using two systems: it is able to determine whether the CV converged to its limit cycle, and when it converged. Moreover, the algorithm is able to quantify the measurement noise. The low computational cost of the developed algorithm allows to execute it in real time during the cyclic voltammetry measurement. In this way, it can be used in order to automate the measurement process which would decide, according to predefined convergence criteria, when to stop cycling.