VTVittorio Di Trapani

Vittorio Di Trapani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vittorio Di Trapani has a total of 107 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Toward XRF-like chemical sensitivity in the laboratory: first hyperspectral x-ray imaging demonstration using the novel CITIUS detector

    by V. Di Trapani, P. Thibault, F. Arfelli, Y. Honjo, K. Ozaki, H. Nishino, Y. Joti, T. Hatsui, F. Orsini, R. H. Menk

    X-ray spectral imaging is an advanced technique that enables material-sensitive imaging by exploiting energy-dependent interactions with matter. In this context, X-ray fluorescence (XRF) represents the benchmark technique. Despite its excellent elemental sensitivity, however, XRF is intrinsically inefficient because it relies on the detection of isotropically emitted secondary fluorescence induced by a focused beam on the sample. This requirement makes the technique difficult to implement with compact laboratory sources and, especially for tomographic applications, highly brilliant synchrotron sources are required. In a laboratory environment, spectral imaging and tomography are typically performed using photon-counting detectors. While this technology offers significant advantages, the limited number of energy thresholds and coarse energy resolution can hamper the separation of materials with similar attenuation properties. Hyperspectral detectors, featuring sub-keV energy resolution and virtually unlimited spectral binning, provide a technological solution to enable high-sensitivity, chemical-specific imaging in the laboratory. Here we present the first application of the novel CITIUS hyperspectral detector to X-ray micro-CT and radiography at the OptImaTo (Optimal Imaging and Tomography) laboratory (Trieste, Italy), based on a liquid MetalJet source (Excillum, Sweden) with a galinstan anode. Using multiple characteristic emission lines (Ga, In, Sn) and a 55 Fe source, a sharp energy resolution in the 0.5–0.8 keV range (full width at half maximum) was found, enabling fine energy binning suitable for advanced quantitative material identification. For the first demonstration, planar and tomographic datasets of two multi-material test samples were analyzed using a newly adapted version of the Minimum-Residual Basis Material Decomposition (MR-BMD) algorithm, optimized for hyperspectral detectors providing tens of energy bins with narrow bandwidths. Results show that the laboratory-based hyperspectral approach combined with MR-BMD enables element-sensitive imaging and, remarkably, separates materials with very similar attenuation, such as water and polypropylene. These results demonstrate accurate material identification and quantification, promisingly approaching XRF-like chemical sensitivity in the laboratory.

  • Wave-optics simulation model for full-field modulation-based tensor tomography using a random wavefront modulator

    by Ginevra Lautizi, Vittorio Di Trapani, Margaux Schmeltz, Marie-Christine Zdora, Ludovic Broche, Ian Sinclair, Mark Mavrogordato, Richard Boardman, Yeajin Lee, Alain Studer, et al.

    In this manuscript, we present a numerical wave-optics simulation model for modulation-based full-field tensor tomography using a random wavefront modulator. We illustrate the effectiveness of the simulation by providing two examples: a modulation-based measurement of a carbon fibre cross, and an X-ray tensor tomography experiment on a cube containing three fibre bundles oriented along three different directions. Moreover, we compare the results of a tensor tomography experiment conducted on two aerospace-type carbon-epoxy materials with the simulated counterparts. The simulation is a versatile tool for investigating new experimental conditions for modulation-based imaging and tensor tomography experiments.

  • Open Access

    X-ray scattering tensor tomography with a random wavefront modulator to study 3D microstructures in archaeological skeletal remains

    by Ginevra Lautizi, Simone A.M. Lemmers, Vittorio Di Trapani, Margaux Schmeltz, Marie-Christine Zdora, Ludovic Broche, Alain Studer, Federica Marone, Marco Stampanoni, Pierre Thibault

    We present an application of X-ray scattering tensor tomography with a random wavefront modulator to resolve the orientation of microstructures in archaeological skeletal remains. We experimentally investigated two fragments from different tissue types — cortical bone and a root dentine — commonly analyzed in archaeological and palaeoanthropological research. This study hints at the potential to advance methodologies for both archaeological research and clinical applications.


  • Open Access

    Robust dark-field signal extraction for modulation-based x-ray tensor tomography

    by Ginevra Lautizi, Vittorio Di Trapani, Alain Studer, Marie-Christine Zdora, Fabio De Marco, Jisoo Kim, Federica Marone, Marco Stampanoni, Pierre Thibault

    We demonstrate a robust signal extraction method for x-ray speckle-based tensor tomography. We validate the effectiveness of the method for several carbon fiber composites, highlighting its potential for industrial applications. The proposed method can be adapted to various acquisition schemes and wavefront-marking optical elements, making it a versatile and robust tool for x-ray scattering tensor tomography.


  • Open Access

    Universal reconstruction method for x-ray scattering tensor tomography based on wavefront modulation

    by Ginevra Lautizi, Alain Studer, Marie-Christine Zdora, Fabio De Marco, Jisoo Kim, Vittorio Di Trapani, Federica Marone, Pierre Thibault, Marco Stampanoni

    We present a versatile method for full-field x-ray scattering tensor tomography that is based on energy conservation and is applicable to data obtained using different wavefront modulators. Using this algorithm, we pave the way for speckle-based tensor tomography. The proposed model relies on a mathematical approach that allows tuning spatial resolution and signal sensitivity. We present the application of the algorithm to three different imaging modalities and demonstrate its potential for applications of x-ray directional dark-field imaging. Published by the American Physical Society 2024


  • Open Access

    Speckle-based imaging (SBI) applications with spectral photon counting detectors at the newly established OPTIMATO (OPTimal IMAging and TOmography) laboratory

    by Vittorio Di Trapani, Sara Savatović, Fabio De Marco, Ginevra Lautizi, Marco Margini, Pierre Thibault

    Speckle-based imaging (SBI) is an advanced X-ray imaging technique that measures phase and dark-field signals, in addition to absorption signals. SBI uses random wavefront modulators to generate speckles and requires two images: one with a speckle pattern alone, and one with both the sample and speckles. SBI reconstruction algorithms retrieve three signals (transmission, refraction, and dark-field) by comparing the two images. In SBI, speckle visibility plays a crucial role in the retrieval of the three signals. When translating the technique from synchrotron sources to compact laboratory setups, the reduced coherence of the source and limitations in the available resolution yield lower speckle visibility, hampering the retrieval of phase and dark-field signals. In this context, direct-detection CdTe X-ray photon-counting detectors (XPCDs) provide an attractive solution, as they allow for a high detection efficiency and optimal spatial resolution enhancing speckle visibility. In this work, we present the newly established OPTIMATO (OPTimal IMAging and TOmography) laboratory for X-ray imaging hosted at the Elettra synchrotron (Trieste, Italy). The setup for SBI with resolutions up to 15 µm including an XPCD and a charge-integrating flat-panel detector (FPD) has been used to acquire SBI data. The main limiting factors when moving SBI applications from synchrotron facilities to compact laboratory setups are summarized. The advantages of XPCDs over FPDs are discussed by comparing the SBI images obtained using both detectors. The potential of the spectral decomposition approach via multi-threshold acquisitions using XPCDs is briefly introduced. The results shown in this work represent the first step toward the realization of a multimodal and multiresolution X-ray facility.


  • Unified Modulation Pattern Analysis (UMPA) algorithm for 1D sensitive X-ray phase contrast imaging techniques

    by V. Di Trapani, L. Brombal, F. De Marco, D. Dreossi, P. Thibault

    X-ray phase contrast imaging (XPCI) techniques are sensitive to refraction (differential-phase) and small-angle X-ray scattering (dark-field) signals, not measurable with conventional absorption imaging techniques. Among XPCI techniques, edge illumination (EI), grating interferometry (GI), and speckle-based imaging (SBI) make use of wavefront markers, such as absorbing masks with periodical apertures or random diffusers, to encode refraction and dark-field signals induced by the sample. The Unified Modulated Pattern Analysis (UMPA) provides an algorithmic solution to extract the transmission, refraction, and dark-field images from EI, GI, and SBI datasets where the wavefront marker is directly resolved by the employed detection system. In its original implementation, UMPA has been designed for XPCI techniques sensitive to refractions along two axes. This work presents a modified version of the algorithm to extend its applicability to all the existing XPCI techniques that use wavefront markers with sensitivity to refraction limited along one direction (UMPA-1D). The algorithm, written in C++ and Cython and parallelized with OpenMP, enables fast reconstruction times that are particularly convenient for large tomographic datasets. The validity of the UMPA-1D has been demonstrated using both simulated images and real acquisitions with an EI setup in beam-tracking mode.


  • High-speed processing of X-ray wavefront marking data with the Unified Modulated Pattern Analysis (UMPA) model

    by Fabio De Marco, Sara Savatović, Ronan Smith, Vittorio Di Trapani, Marco Margini, Ginevra Lautizi, Pierre Thibault

    Wavefront-marking X-ray imaging techniques use e.g., sandpaper or a grating to generate intensity fluctuations, and analyze their distortion by the sample in order to retrieve attenuation, phase-contrast, and dark-field information. Phase contrast yields an improved visibility of soft-tissue specimens, while dark-field reveals small-angle scatter from sub-resolution structures. Both have found many biomedical and engineering applications. The previously developed Unified Modulated Pattern Analysis (UMPA) model extracts these modalities from wavefront-marking data. We here present a new UMPA implementation, capable of rapidly processing large datasets and featuring capabilities to greatly extend the field of view. We also discuss possible artifacts and additional new features.


  • Multi-material spectral photon-counting micro-CT with minimum residual decomposition and self-supervised deep denoising

    by Vittorio Di Trapani, Luca Brombal, Francesco Brun

    Spectral micro-CT imaging with direct-detection energy discriminating photon counting detectors having small pixel size (< 100×100 µm2) is mainly hampered by: i) the limited energy resolution of the imaging device due to charge sharing effects and ii) the unavoidable noise amplification in the images resulting from basis material decomposition. In this work, we present a cone-beam micro-CT setup that includes a CdTe photon counting detector implementing a charge summing hardware solution to correct for the charge-sharing issue and an innovative image processing pipeline based on accurate modeling of the spectral response of the imaging system, an improved basis material decomposition (BMD) algorithm named minimum-residual BMD (MR-BMD), and self-supervised deep convolutional denoising. Experimental tomographic projections having a pixel size of 45×45 µm2 of a plastinated mouse sample including I, Ba, and Gd small cuvettes were acquired. Results demonstrate the capability of the combined hardware and software tools to sharply discriminate even between materials having their K-Edge separated by a few keV, such as e.g., I and Ba. By evaluating the quality of the reconstructed decomposed images (water, bone, I, Ba, and Gd), the quantitative performances of the spectral system are here assessed and discussed.