Bin Cai
Bin Cai has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Shao Hui Guo
China University of Petroleum
3 shared publicationsChun Mao Chen
China University of Petroleum
2 shared publicationsChunmao Chen
2 shared publicationsGuang Xu Yan
China University of Petroleum
2 shared publicationsGuangxu Yan
2 shared publications- Guangxu Yan
State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil & Gas Pollution Control, China University of Petroleum, 18 Fuxue Road, Changping District, Beijing 102249, PR China
2 shared publications
Latest Publications
- 1 August 2016
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 112, 170-177
Comparison of phytoremediation, bioaugmentation and natural attenuation for remediating saline soil contaminated by heavy crude oil
- 1 August 2016
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 112, 170-177
Comparison of phytoremediation, bioaugmentation and natural attenuation for remediating saline soil contaminated by heavy crude oil
- 1 March 2016
- Published by Elsevier in Renewable Energy
- Vol. 87, 437-444
Influence of packing material characteristics on the performance of microbial fuel cells using petroleum refinery wastewater as fuel
- 1 March 2016
- Published by Elsevier in Renewable Energy
- Vol. 87, 437-444
Influence of packing material characteristics on the performance of microbial fuel cells using petroleum refinery wastewater as fuel
- 19 March 2015
- Published by Taylor & Francis in Petroleum Science and Technology
- Vol. 33 (6) , 717-723
Bioremediation of Crude Oil Contaminated Soil
A laboratory study was undertaken to bioremediation crude oil contaminated soil by isolated strains. Pseudomonas strain A as the most superior indigenous biodegrader was selected. At the optimal growth condition of pH 7 and with 5 g/L NaCl, cosubstrate α-lactose, and inorganic salt FeSO4, 82.3% of crude oil degradation efficiency was obtained. Furthermore, characteristics of chemical composition during the biotreatment indicated that saturation hydrocarbons and some aromatics were effectively removed by strain A. N-alkane in crude oil was preferentially degraded, especially those in the range of nC16–nC24. Biodegradation of aromatics depended on benzene ring numbers and complexity of structures.
- 19 March 2015
- Published by Taylor & Francis in Petroleum Science and Technology
- Vol. 33 (6) , 717-723
Bioremediation of Crude Oil Contaminated Soil
A laboratory study was undertaken to bioremediation crude oil contaminated soil by isolated strains. Pseudomonas strain A as the most superior indigenous biodegrader was selected. At the optimal growth condition of pH 7 and with 5 g/L NaCl, cosubstrate α-lactose, and inorganic salt FeSO4, 82.3% of crude oil degradation efficiency was obtained. Furthermore, characteristics of chemical composition during the biotreatment indicated that saturation hydrocarbons and some aromatics were effectively removed by strain A. N-alkane in crude oil was preferentially degraded, especially those in the range of nC16–nC24. Biodegradation of aromatics depended on benzene ring numbers and complexity of structures.
- Open Access
- 1 March 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 53 (10) , 2792-2798
Biodegradability evaluation of pollutants in acrylonitrile wastewaters based on particle size distribution
Acrylonitrile wastewaters (ANWs) treatment is a big trouble for chemical fiber industry in China, and there was not yet an effective biological treatment technology for ANWs due to the lack of detailed analysis on the biodegradability of pollutants. In this work, two typical point-source ANWs, acrylonitrile synthesis wastewater (ANSW), and acrylonitrile polymerization wastewater (ANPW) were fractionated by gradient membrane separation method based on the pollutants particle size distribution (PSD). Moreover, biochemical oxygen demand/chemical oxygen demand (COD) ratios, oxygen uptake respirometric tests, dehydrogenase activity tests, and simulated aeration tests were integrated to evaluate the biodegradability of PSD-based pollutants in ANWs. The results showed that most COD were from dissolved fractions in both of ANSW and ANPW. For ANSW, the soluble fractions had greater biodegradation potential than particulate and colloidal fractions. Colloidal fractions are easier to be biodegraded than particulate and soluble fractions in ANPW. The simulated aerobic tests showed that, only 54.72 and 21.62% of COD was removed from ANSW and ANPW, respectively. It indicated that activated sludge treatment process was inadequate to ANWs. The correlations between PSD-based pollutants and their biodegradability of ANWs can be used to guide the development of ANWs treatment technologies.
- 1 March 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 53 (10) , 2792-2798
Open AccessBiodegradability evaluation of pollutants in acrylonitrile wastewaters based on particle size distribution
Acrylonitrile wastewaters (ANWs) treatment is a big trouble for chemical fiber industry in China, and there was not yet an effective biological treatment technology for ANWs due to the lack of detailed analysis on the biodegradability of pollutants. In this work, two typical point-source ANWs, acrylonitrile synthesis wastewater (ANSW), and acrylonitrile polymerization wastewater (ANPW) were fractionated by gradient membrane separation method based on the pollutants particle size distribution (PSD). Moreover, biochemical oxygen demand/chemical oxygen demand (COD) ratios, oxygen uptake respirometric tests, dehydrogenase activity tests, and simulated aeration tests were integrated to evaluate the biodegradability of PSD-based pollutants in ANWs. The results showed that most COD were from dissolved fractions in both of ANSW and ANPW. For ANSW, the soluble fractions had greater biodegradation potential than particulate and colloidal fractions. Colloidal fractions are easier to be biodegraded than particulate and soluble fractions in ANPW. The simulated aerobic tests showed that, only 54.72 and 21.62% of COD was removed from ANSW and ANPW, respectively. It indicated that activated sludge treatment process was inadequate to ANWs. The correlations between PSD-based pollutants and their biodegradability of ANWs can be used to guide the development of ANWs treatment technologies.
- 5 February 2014
- Published by Wiley in CLEAN – Soil, Air, Water
- Vol. 42 (10) , 1393-1401
Characterization of Dry‐Spun Acrylic Fiber Wastewater by Particle Size Distribution, Biodegradability, and Chemical Composition
Dry‐spun acrylic fiber wastewater of large volume, high organic concentration, and low biodegradability is difficult to be treated by traditional treatment process. Detailed characterization of the wastewater is necessary to provide valuable information on designing effective treatment processes. The objective of this paper was to investigate particle size distribution and the associated biodegradability and chemical composition of dry‐spun acrylic fiber wastewater. For this purpose, gradient membrane separation was carried out, the evaluation of biochemical oxygen demand over a 5‐day period/chemical oxygen demand (COD) and tetrazolium chloride‐dehydrogenase activity was investigated and analysis of Fourier transform infrared spectroscopy, gas chromatography‐mass spectrometry and electrospray ionization‐Fourier transform ion cyclotron resonance mass spectrometer was characterized. It is appeared that the particles are consecutive distributed in the wastewater. The main pollutants are soluble organics accounting for 61.4% of COD, followed by colloidal compounds (25.7% COD) and settleable/supracolloidal compounds (12.9% COD). The organics distributed in the range of 2–10 nm are easily to be biodegraded, but soluble and settleable/supracolloidal fractions are biorefractory. The reason could be high molecular polymers containing NH, OH, CO groups were exited in the settleable/supracolloidal fractions, and some toxic components including C6H6N2, C7H8O2, and some NSO heterocycles were dissolved in the soluble fractions. The results indicated that removing the settleable or supracolloidal substances and improving biodegradability of the soluble organics by pretreatment are necessary for the treatment of dry‐spun acrylic fiber wastewater.
- 5 February 2014
- Published by Wiley in CLEAN – Soil, Air, Water
- Vol. 42 (10) , 1393-1401
Characterization of Dry‐Spun Acrylic Fiber Wastewater by Particle Size Distribution, Biodegradability, and Chemical Composition
Dry‐spun acrylic fiber wastewater of large volume, high organic concentration, and low biodegradability is difficult to be treated by traditional treatment process. Detailed characterization of the wastewater is necessary to provide valuable information on designing effective treatment processes. The objective of this paper was to investigate particle size distribution and the associated biodegradability and chemical composition of dry‐spun acrylic fiber wastewater. For this purpose, gradient membrane separation was carried out, the evaluation of biochemical oxygen demand over a 5‐day period/chemical oxygen demand (COD) and tetrazolium chloride‐dehydrogenase activity was investigated and analysis of Fourier transform infrared spectroscopy, gas chromatography‐mass spectrometry and electrospray ionization‐Fourier transform ion cyclotron resonance mass spectrometer was characterized. It is appeared that the particles are consecutive distributed in the wastewater. The main pollutants are soluble organics accounting for 61.4% of COD, followed by colloidal compounds (25.7% COD) and settleable/supracolloidal compounds (12.9% COD). The organics distributed in the range of 2–10 nm are easily to be biodegraded, but soluble and settleable/supracolloidal fractions are biorefractory. The reason could be high molecular polymers containing NH, OH, CO groups were exited in the settleable/supracolloidal fractions, and some toxic components including C6H6N2, C7H8O2, and some NSO heterocycles were dissolved in the soluble fractions. The results indicated that removing the settleable or supracolloidal substances and improving biodegradability of the soluble organics by pretreatment are necessary for the treatment of dry‐spun acrylic fiber wastewater.
- 7 October 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 356-360, 1704-1707
Batch Scale Study on the Treatment of Spinning Effluents Containing Dimethyl Formamide from Acrylic Fiber Manufacturing
Spinning effluents (SE) from dry-spun acrylic fiber manufacturing are hard to degrade due to the containing of vast dimethyl formamide (DMF). Activated carbon, ion exchange and Fenton oxidation were applied to solve this problem. Coconut-shell-based activated carbon exhibited a better performance than the coal-based and nut-shell-based ones did. At the optimal dosage of 1g/L, pH=6 and 30 °C, the removal of COD and DMF were respectively 84.39% and 66.14%. Ion exchange resins are rated as NKA-9 > D301R > D201 > 201×7 respected to the performance, and the optimum COD and DMF removal were 82.31% and 68.76% at the NKA-9 dosage of 0.22 g, pH=7 and 30°C. The most appropriate treatment process appeared to be Fenton. COD and DMF were finally reduced to 23.29 mg/L and 23.43 mg/L, with removal rates of 90.23% and 79.43% respectively. This optimum efficiency was obtained at c(H2O2)/c(Fe2+) of 14:1, pH=3, 50 °C, and an oxidation time of 3 h.
- 7 October 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 356-360, 1704-1707
Batch Scale Study on the Treatment of Spinning Effluents Containing Dimethyl Formamide from Acrylic Fiber Manufacturing
Spinning effluents (SE) from dry-spun acrylic fiber manufacturing are hard to degrade due to the containing of vast dimethyl formamide (DMF). Activated carbon, ion exchange and Fenton oxidation were applied to solve this problem. Coconut-shell-based activated carbon exhibited a better performance than the coal-based and nut-shell-based ones did. At the optimal dosage of 1g/L, pH=6 and 30 °C, the removal of COD and DMF were respectively 84.39% and 66.14%. Ion exchange resins are rated as NKA-9 > D301R > D201 > 201×7 respected to the performance, and the optimum COD and DMF removal were 82.31% and 68.76% at the NKA-9 dosage of 0.22 g, pH=7 and 30°C. The most appropriate treatment process appeared to be Fenton. COD and DMF were finally reduced to 23.29 mg/L and 23.43 mg/L, with removal rates of 90.23% and 79.43% respectively. This optimum efficiency was obtained at c(H2O2)/c(Fe2+) of 14:1, pH=3, 50 °C, and an oxidation time of 3 h.
- 7 October 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 356-360, 986-989
Pollutants Characterization of Spinning Effluents Containing Dimethyl Formamide from Dry-Spun Acrylic Fiber Manufacturing by Multi Scale Membrane Filtration
Spinning effluents (SE) from dry-spun acrylic fiber manufacturing are hard to biodegrade due to the high concentration of dimethyl formamide (DMF). This paper evaluated the pollutant distribution characteristics of SE by means of multi scale membrane filtritions, including microfiltration, ultrafiltration, nanofiltration and reverse osmosis. Scanning electron microscopy (SEM) and nano particle size analyzer (NPSA) tests were also used as assistant measurements. The major pollutant diameters in SE range from 20 nm to 30 nm with a statistical median size of 300nm. The particulate, colloidal and soluble organic fractions contribute 8.44%, 37.13% and 54.43% to the initial COD. 11.4%, 13.67% and 71.92% of the initial DMF distributes in the particle, colloidal and soluble portion respectively. The data of ammonia are relevantly 22.17%, 11.45% and 56.38%, indicating that the soluble fraction, which is also poor in biodegradability, plays a key role in SE treatment. Beside, the majority of AN distributes in the soluble range while 90.98% of cyanide distributes in the particulate and supracolloidal portions.
- 7 October 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 356-360, 986-989
Pollutants Characterization of Spinning Effluents Containing Dimethyl Formamide from Dry-Spun Acrylic Fiber Manufacturing by Multi Scale Membrane Filtration
Spinning effluents (SE) from dry-spun acrylic fiber manufacturing are hard to biodegrade due to the high concentration of dimethyl formamide (DMF). This paper evaluated the pollutant distribution characteristics of SE by means of multi scale membrane filtritions, including microfiltration, ultrafiltration, nanofiltration and reverse osmosis. Scanning electron microscopy (SEM) and nano particle size analyzer (NPSA) tests were also used as assistant measurements. The major pollutant diameters in SE range from 20 nm to 30 nm with a statistical median size of 300nm. The particulate, colloidal and soluble organic fractions contribute 8.44%, 37.13% and 54.43% to the initial COD. 11.4%, 13.67% and 71.92% of the initial DMF distributes in the particle, colloidal and soluble portion respectively. The data of ammonia are relevantly 22.17%, 11.45% and 56.38%, indicating that the soluble fraction, which is also poor in biodegradability, plays a key role in SE treatment. Beside, the majority of AN distributes in the soluble range while 90.98% of cyanide distributes in the particulate and supracolloidal portions.
- 1 September 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 332-334, 1590-1593
Pollutants Characterization of Polymerization Effluents from Dry-Spun Acrylic Fiber Manufacturing by Multi Scale Membrane Filtration
Polymerization effluents (PME) from dry-spun acrylic fiber manufacturing are hard to degrade. This paper evaluated the distribution characteristics of PME pollutants by means of multi scale membrane filtrations, including microfiltration (5 μm and 1 μm), ultrafiltration (50 KD, 10 KD and 6 KD), nanofiltration and reverse osmosis. Scanning electron microscopy (SEM) and laser particle size analyzer (LPSA) tests were also used as assistant measurements. The majority of particles in PME are mainly categorized as supracolloidal structures. 70% of them rage from 5 μm to 20 μm with a median size of 9.99 μm. Particulate, colloidal and soluble portions contribute 7.6%, 8.2% and 75.2% to the initial COD, meaning that the soluble fraction, which is also poor in biodegradability, plays a key role in PME treatment. 26.8% of TN, mainly consisting of various acrylonitrile copolymers, exists in the colloidal portion; while 70.5% of it, mainly comprised of ammonia, cyanide and nitrile, distributes in the soluble portion. The distribution characteristics of ammonia and SO32- are similar. Respectively 92.7% and 94.7% distributes in the soluble portion.
- 1 September 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 332-334, 1590-1593
Pollutants Characterization of Polymerization Effluents from Dry-Spun Acrylic Fiber Manufacturing by Multi Scale Membrane Filtration
Polymerization effluents (PME) from dry-spun acrylic fiber manufacturing are hard to degrade. This paper evaluated the distribution characteristics of PME pollutants by means of multi scale membrane filtrations, including microfiltration (5 μm and 1 μm), ultrafiltration (50 KD, 10 KD and 6 KD), nanofiltration and reverse osmosis. Scanning electron microscopy (SEM) and laser particle size analyzer (LPSA) tests were also used as assistant measurements. The majority of particles in PME are mainly categorized as supracolloidal structures. 70% of them rage from 5 μm to 20 μm with a median size of 9.99 μm. Particulate, colloidal and soluble portions contribute 7.6%, 8.2% and 75.2% to the initial COD, meaning that the soluble fraction, which is also poor in biodegradability, plays a key role in PME treatment. 26.8% of TN, mainly consisting of various acrylonitrile copolymers, exists in the colloidal portion; while 70.5% of it, mainly comprised of ammonia, cyanide and nitrile, distributes in the soluble portion. The distribution characteristics of ammonia and SO32- are similar. Respectively 92.7% and 94.7% distributes in the soluble portion.
- 1 September 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 332-334, 1582-1585
Treatment of Polymerization Effluents from Acrylic Fiber Manufacturing Using a Combination Process of Flocculation and Fenton Oxidation
A combined process of flocculation and Fenton oxidation was studied for the treatment of polymerization effluents (PME) from the manufacture of dry-spun acrylic fibers. 5 inorganic and 3 organic flocculants were investigated and the optimal regents and conditons were PAC (at 25°C, pH=8 and a dosage of 150 mg/L), and Z7650 (at 25°C, pH=6 and a dosage of 10 mg/L). Under this condition, the COD was removed by 23.1% of the initial 1824 mg/L. The optimum efficiency of Fenton process was determined at 25°C and pH=4 with a reaction time of 90 min. The dosage of H2O2 and the rate of c(H2O2)/c(FeSO4) were respectively 0.53 mol/L and 20:1. Finally, the removal of COD, total nitrogen, ammonia, SO32- and turbidity by the combined process were 64.0%, 99.3%, 99.6%, 99.7% and 89.4% respectively. BOD/COD was also improved from 0.09 to 0.25.
- 1 September 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 332-334, 1582-1585
Treatment of Polymerization Effluents from Acrylic Fiber Manufacturing Using a Combination Process of Flocculation and Fenton Oxidation
A combined process of flocculation and Fenton oxidation was studied for the treatment of polymerization effluents (PME) from the manufacture of dry-spun acrylic fibers. 5 inorganic and 3 organic flocculants were investigated and the optimal regents and conditons were PAC (at 25°C, pH=8 and a dosage of 150 mg/L), and Z7650 (at 25°C, pH=6 and a dosage of 10 mg/L). Under this condition, the COD was removed by 23.1% of the initial 1824 mg/L. The optimum efficiency of Fenton process was determined at 25°C and pH=4 with a reaction time of 90 min. The dosage of H2O2 and the rate of c(H2O2)/c(FeSO4) were respectively 0.53 mol/L and 20:1. Finally, the removal of COD, total nitrogen, ammonia, SO32- and turbidity by the combined process were 64.0%, 99.3%, 99.6%, 99.7% and 89.4% respectively. BOD/COD was also improved from 0.09 to 0.25.