Benoit Clement
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Benoit Clement has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Haas
New York University
148 shared publications - Frank Filthaut
Radboud University Nijmegen
148 shared publications - Harald Fox
Lancaster University
148 shared publications - Lee Sawyer
Louisiana Tech University
148 shared publications - Michael Begel
Brookhaven National Laboratory
148 shared publications A. Khanov
Oklahoma State University
147 shared publications
Latest Publications
- Open Access
- 22 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Further search for magnetic-field-induced neutron disappearance in an ultracold neutron beam
- 22 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Open AccessFurther search for magnetic-field-induced neutron disappearance in an ultracold neutron beam
- Open Access
- 6 November 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (19) , 191801
Search for Neutron-to-Hidden-Neutron Oscillations in an Ultracold Neutron Beam
Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Neutron-to-hidden-neutron oscillations are among the possible mixing processes and have been tested with ultracold neutron storage and passing-through-wall experiments to set constraints on the oscillation period . These searches probe the oscillations as a function of the mass splitting due to the neutron-hidden-neutron energy degeneracy. In this work, we present a new limit derived from neutron disappearance in ultracold neutron beam experiments. The overall limit, given by , covers the yet unexplored intermediate mass-splitting range and contributes to the ongoing research on hidden sectors.- 6 November 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (19) , 191801
Open AccessSearch for Neutron-to-Hidden-Neutron Oscillations in an Ultracold Neutron Beam
Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Neutron-to-hidden-neutron oscillations are among the possible mixing processes and have been tested with ultracold neutron storage and passing-through-wall experiments to set constraints on the oscillation period . These searches probe the oscillations as a function of the mass splitting due to the neutron-hidden-neutron energy degeneracy. In this work, we present a new limit derived from neutron disappearance in ultracold neutron beam experiments. The overall limit, given by , covers the yet unexplored intermediate mass-splitting range and contributes to the ongoing research on hidden sectors. - 19 December 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 106 (6) , 062815
Determination of diffusion coefficients of mercury atoms in various gases from longitudinal spin relaxation in magnetic gradients
We present a method to measure the binary diffusion coefficient of mercury atoms in a gas at room temperature and low pressure. It is based on the measurement of the longitudinal spin relaxation of optically pumped mercury-199 atoms in a magnetic field gradient. We provide a consistent set of diffusion coefficients for helium-3, helium-4, argon, krypton, xenon, nitrogen, carbon dioxide, oxygen, and air.
- 19 December 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 106 (6) , 062815
Determination of diffusion coefficients of mercury atoms in various gases from longitudinal spin relaxation in magnetic gradients
We present a method to measure the binary diffusion coefficient of mercury atoms in a gas at room temperature and low pressure. It is based on the measurement of the longitudinal spin relaxation of optically pumped mercury-199 atoms in a magnetic field gradient. We provide a consistent set of diffusion coefficients for helium-3, helium-4, argon, krypton, xenon, nitrogen, carbon dioxide, oxygen, and air.
- Open Access
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 095105
The very large n2EDM magnetically shielded room with an exceptional performance for fundamental physics measurements
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 μT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 095105
Open AccessThe very large n2EDM magnetically shielded room with an exceptional performance for fundamental physics measurements
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 μT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.
- Top Cited PapersOpen Access
- 28 February 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 124 (8) , 081803
Measurement of the Permanent Electric Dipole Moment of the Neutron
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey’s method of separated oscillating magnetic fields with ultracold neutrons. Our measurement stands in the long history of EDM experiments probing physics violating time-reversal invariance. The salient features of this experiment were the use of a comagnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic-field changes. The statistical analysis was performed on blinded datasets by two separate groups, while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is .- 28 February 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 124 (8) , 081803
Top Cited PapersOpen AccessMeasurement of the Permanent Electric Dipole Moment of the Neutron
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey’s method of separated oscillating magnetic fields with ultracold neutrons. Our measurement stands in the long history of EDM experiments probing physics violating time-reversal invariance. The salient features of this experiment were the use of a comagnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic-field changes. The statistical analysis was performed on blinded datasets by two separate groups, while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is . - Open Access
- 12 December 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 219, 02002
The n2EDM experiment at the Paul Scherrer Institute
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
- 12 December 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 219, 02002
Open AccessThe n2EDM experiment at the Paul Scherrer Institute
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
- 1 September 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (09) , P09003
Boron-10 conversion layer for ultra-cold neutron detection
We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform over a large ultra-cold neutron velocity range. The designed titanium-boron-nickel multilayer film was deposited on silicon using a microwave plasma-assisted co-sputtering method (first, for test purpose, on silicon wafers, then directly on the surface of a CCD sensor). The obtained sensor was then tested using both cold and ultra-cold neutrons.
- 1 September 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (09) , P09003
Boron-10 conversion layer for ultra-cold neutron detection
We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform over a large ultra-cold neutron velocity range. The designed titanium-boron-nickel multilayer film was deposited on silicon using a microwave plasma-assisted co-sputtering method (first, for test purpose, on silicon wafers, then directly on the surface of a CCD sensor). The obtained sensor was then tested using both cold and ultra-cold neutrons.
- Open Access
Boron-10 conversion layer for ultra-cold neutron detection
We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform over a large ultra-cold neutron velocity range. The designed titanium-boron-nickel multilayer film was deposited on silicon using a microwave plasma-assisted co-sputtering method (first, for test purpose, on silicon wafers, then directly on the surface of a CCD sensor). The obtained sensor was then tested using both cold and ultra-cold neutrons.
Open AccessBoron-10 conversion layer for ultra-cold neutron detection
We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform over a large ultra-cold neutron velocity range. The designed titanium-boron-nickel multilayer film was deposited on silicon using a microwave plasma-assisted co-sputtering method (first, for test purpose, on silicon wafers, then directly on the surface of a CCD sensor). The obtained sensor was then tested using both cold and ultra-cold neutrons.