Heiko Iken
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Heiko Iken has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Michael Josef Schöening
Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428 Jülich, Germany
2 shared publications Aleksander Drinic
Fibrothelium GmbH, TRIWO Technopark Aachen, Philipsstr. 8, 52068, Aachen, Germany
1 shared publicationAlexander Goretzki
Institute of Nano‐ and Biotechnologies Aachen University of Applied Sciences Heinrich‐Mußmann‐Str. 1 52428 Jülich Germany
1 shared publication- Alexander Kopp
Meotec GmbH, 52068 Aachen, Germany
1 shared publication Caspar Gottschalk
Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Heinrich-Mußmann-Str. 1, 52428 Jülich, Germany
1 shared publicationDenise Molinnus
Institute of Nano- and Biotechnologies (INB), FH Aachen, Campus Jülich, Heinrich-Mußmann-Strasse 1, 52428, Jülich, Germany
1 shared publication
Latest Publications
- 1 November 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 346, 130422
Formation of controllable pH gradients inside microchannels by using light-addressable electrodes
- 1 November 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 346, 130422
Formation of controllable pH gradients inside microchannels by using light-addressable electrodes
- 1 July 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 183, 113204
Towards a flexible electrochemical biosensor fabricated from biocompatible Bombyx mori silk
- 1 July 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 183, 113204
Towards a flexible electrochemical biosensor fabricated from biocompatible Bombyx mori silk
- 7 May 2019
- Published by Wiley in Physica Status Solidi (a)
- Vol. 216 (12)
Development of a Combined pH‐ and Redox‐Sensitive Bi‐Electrode Glass Thin‐Film Sensor
In this work, a combined pH‐ and redox‐sensitive bi‐electrode glass thin‐film sensor is developed for the simultaneous detection of pH and redox potential in aqueous solutions. Therefore, the pH‐ and redox‐sensitive glass bulk materials are prepared first by glass‐pouring processes and tailored regarding the sensing properties as well as the deposition suitability. A layout for the bi‐electrode transducer structure (sensor chip) is developed is been fabricated on a glass substrate via conventional thin‐film techniques. The sensitive glass bulk materials are transferred on the bi‐electrode structures by means of pulsed laser deposition technique (PLD). The fabricated sensors are physically and electrochemically characterized by means of scanning electron microscopy (SEM), Rutherford backscattering spectrometry (RBS), profilometry, impedance‐ and potentiometric measurements. The fabricated sensor structures are successfully tested in the range pH 5–9 and the redox potential in different solutions including also real test samples of soda and pool water.
- 7 May 2019
- Published by Wiley in Physica Status Solidi (a)
- Vol. 216 (12)
Development of a Combined pH‐ and Redox‐Sensitive Bi‐Electrode Glass Thin‐Film Sensor
In this work, a combined pH‐ and redox‐sensitive bi‐electrode glass thin‐film sensor is developed for the simultaneous detection of pH and redox potential in aqueous solutions. Therefore, the pH‐ and redox‐sensitive glass bulk materials are prepared first by glass‐pouring processes and tailored regarding the sensing properties as well as the deposition suitability. A layout for the bi‐electrode transducer structure (sensor chip) is developed is been fabricated on a glass substrate via conventional thin‐film techniques. The sensitive glass bulk materials are transferred on the bi‐electrode structures by means of pulsed laser deposition technique (PLD). The fabricated sensors are physically and electrochemically characterized by means of scanning electron microscopy (SEM), Rutherford backscattering spectrometry (RBS), profilometry, impedance‐ and potentiometric measurements. The fabricated sensor structures are successfully tested in the range pH 5–9 and the redox potential in different solutions including also real test samples of soda and pool water.