Haoxiang Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haoxiang Wu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Woonchung C. Wong
Research Center for Eco-Environmental Engineering, Dongguan University of Technology, Dongguan, Guangdong 523808, China
4 shared publications - Ka Man Lai
Department of Biology, Hong Kong Baptist University, Kowloon Tong, Hong Kong.
2 shared publications Liwen Luo
Department of Biology, Hong Kong Baptist University, Hong Kong Special Administrative Region, People’s Republic of China
1 shared publicationNatasha Maria Barnes
Department of Biology Hong Kong Special Administrative Region Hong Kong Baptist University Hong Kong China
1 shared publicationP. Y. Chan
Department of Biology, Hong Kong Baptist University, Kowloon Tong, Hong Kong Special Administrative Region, China
1 shared publicationT. T. Chan
Department of Biology, Hong Kong Baptist University, Kowloon Tong, Hong Kong Special Administrative Region, China
1 shared publication
Latest Publications
- Open Access
- 30 June 2022
- Published by MDPI AG in Journal of Fungi
- Vol. 8 (7) , 696
Temperature versus Relative Humidity: Which Is More Important for Indoor Mold Prevention?
Temperature is known as one of the abiotic factors that can affect mold growth. Many mold growth prediction models consider temperature as one of the parameters that can significantly impact mold growth indoors, and hence temperature has been targeted by different indoor mold prevention strategies on different premises. For example, European guidelines for libraries suggest a temperature of 19 °C to preserve books. However, running low temperature air-conditioning (AC) costs substantially more energy, and thus a higher temperature (e.g., 25.5 °C) has been regularly proposed as the recommended indoor temperature for general indoor environments in Hong Kong. It is, therefore, needed to understand whether or not the reduction of indoor temperature would lead to better effectiveness of mold prevention. Using Cladosporium cladosporioides (C. cladosporioides) as the model, its germinating spores were challenged in C. cladosporioides to wet-dry cycles with different combinations of relative humidity (RH, 40%, 60% and 80%) and temperature (19 °C and 28 °C) levels. The survival, lipid peroxidation and catalase (CAT) activity of the treated spores were monitored and compared. C. cladosporioides spores showed similar levels of viability, lipid peroxidation and CAT activity when they were exposed to 19 °C and 28 °C at the same RH, but substantially lower survival and higher oxidative stress were observed under the wet-dry cycles with 40% RH dry periods compared with 60% and 80% RH at both temperatures, suggesting that indoor temperature does not tend to affect the resistance of C. cladosporioides to wet-dry cycles as significantly as the RH level of the dry period. Collectively, this study suggests a more important role for moisture over temperature in indoor mold prevention. The outcome of this study may facilitate the sustainable management of indoor mold problems in buildings.
- 30 June 2022
- Published by MDPI AG in Journal of Fungi
- Vol. 8 (7) , 696
Open AccessTemperature versus Relative Humidity: Which Is More Important for Indoor Mold Prevention?
Temperature is known as one of the abiotic factors that can affect mold growth. Many mold growth prediction models consider temperature as one of the parameters that can significantly impact mold growth indoors, and hence temperature has been targeted by different indoor mold prevention strategies on different premises. For example, European guidelines for libraries suggest a temperature of 19 °C to preserve books. However, running low temperature air-conditioning (AC) costs substantially more energy, and thus a higher temperature (e.g., 25.5 °C) has been regularly proposed as the recommended indoor temperature for general indoor environments in Hong Kong. It is, therefore, needed to understand whether or not the reduction of indoor temperature would lead to better effectiveness of mold prevention. Using Cladosporium cladosporioides (C. cladosporioides) as the model, its germinating spores were challenged in C. cladosporioides to wet-dry cycles with different combinations of relative humidity (RH, 40%, 60% and 80%) and temperature (19 °C and 28 °C) levels. The survival, lipid peroxidation and catalase (CAT) activity of the treated spores were monitored and compared. C. cladosporioides spores showed similar levels of viability, lipid peroxidation and CAT activity when they were exposed to 19 °C and 28 °C at the same RH, but substantially lower survival and higher oxidative stress were observed under the wet-dry cycles with 40% RH dry periods compared with 60% and 80% RH at both temperatures, suggesting that indoor temperature does not tend to affect the resistance of C. cladosporioides to wet-dry cycles as significantly as the RH level of the dry period. Collectively, this study suggests a more important role for moisture over temperature in indoor mold prevention. The outcome of this study may facilitate the sustainable management of indoor mold problems in buildings.
- 12 February 2022
- Published by Wiley in Indoor Air
- Vol. 32 (2) , e12991
Mechanisms regulating the airborne survival of Klebsiella pneumoniae under different relative humidity and temperature levels
In this study, Klebsiella pneumoniae was suspended in synthetic saliva in a nebulizer (N0) and nebulized for 5 min (N5) into an aerosol chamber and further prolonged in the aerosolization phase for 15 min (A15) under four different conditions: 20°C, 50% relative humidity (RH); 20°C, 80% RH; 30°C, 50% RH; and 30°C, 80% RH. Samples were collected at N0, N5, and A15, then subjected to survival analysis and comparative transcriptomic analysis in order to help elucidate the underlying mechanisms of airborne survival. Survival analysis shows that a higher humidity and lower temperature were favorable for the airborne survival of K. pneumoniae, and the effect of RH was more remarkable at 20°C than that at 30°C. The RNA-seq results show that during the nebulization phase (N0 vs. N5), a total number of 201 differentially expressed genes (DEGs) were identified (103 downregulated and 98 upregulated). Comparison between nebulization and aerosolization phases (N5 vs. A15) indicates up to 132 DEGs, with 46 downregulated and 86 upregulated. The most notable groups of genes are those involved in cellular remodeling, metabolism and energy processes. Alarmingly, the mbl gene, which encodes antibiotic resistance in K. pneumoniae, was upregulated during the suspension phase under all the tested conditions. This study provides insights into the control of airborne transmitted diseases.
- 12 February 2022
- Published by Wiley in Indoor Air
- Vol. 32 (2) , e12991
Mechanisms regulating the airborne survival of Klebsiella pneumoniae under different relative humidity and temperature levels
In this study, Klebsiella pneumoniae was suspended in synthetic saliva in a nebulizer (N0) and nebulized for 5 min (N5) into an aerosol chamber and further prolonged in the aerosolization phase for 15 min (A15) under four different conditions: 20°C, 50% relative humidity (RH); 20°C, 80% RH; 30°C, 50% RH; and 30°C, 80% RH. Samples were collected at N0, N5, and A15, then subjected to survival analysis and comparative transcriptomic analysis in order to help elucidate the underlying mechanisms of airborne survival. Survival analysis shows that a higher humidity and lower temperature were favorable for the airborne survival of K. pneumoniae, and the effect of RH was more remarkable at 20°C than that at 30°C. The RNA-seq results show that during the nebulization phase (N0 vs. N5), a total number of 201 differentially expressed genes (DEGs) were identified (103 downregulated and 98 upregulated). Comparison between nebulization and aerosolization phases (N5 vs. A15) indicates up to 132 DEGs, with 46 downregulated and 86 upregulated. The most notable groups of genes are those involved in cellular remodeling, metabolism and energy processes. Alarmingly, the mbl gene, which encodes antibiotic resistance in K. pneumoniae, was upregulated during the suspension phase under all the tested conditions. This study provides insights into the control of airborne transmitted diseases.
- 28 October 2021
- Published by Taylor & Francis in Environmental Technology
- Vol. 44 (7) , 1018-1026
The role of hygrodynamic resistance compared to biofilm formation in helping pathogenic bacteria dominate air-conditioning units recovered from odour problems
Our previous study (Ng et al., 2018) proposed to install filters in odorous air-conditioning units (ACUs) to block the entry of skin squames. This approach has well tackled the odor problems and no further report regarding smelly ACUs has been received. In this study, we revisited and sampled the ACUs installed with filters earlier to study the bacterial communities inside the ACUs using 16S amplicon sequencing. We identified 26 genera and found that the skin bacteria isolated in the previous work were absent in this study. Two pathogenic bacteria, Methylobacterium and Sphingomonas, dominated ACUs instead. Afterward, these two bacteria were identified to species level (Methylobacterium organophilum and Sphingomonas paucimobilis, respectively), and examined in terms of their biofilm formation ability and resistance to changing moisture conditions together with another prevalent species isolated in our previous study, namely Micrococcus luteus, in order to understand the mechanisms of the survival of bacteria in ACUs. In general, M. organophilum and M. luteus showed good biofilm formation ability at all tested temperature levels, but S. paucimobilis only displayed limited biofilm formation. Whereas, all these three bacteria well maintained their survival after wet-dry cycles. These results suggest that compared to biofilm formation, ability to survive under hygrodynamics tends to play a more important role in helping bacteria dominate ACUs. Further, this study implies that the absence of odor problem does not guarantee a healthy environment, more attentions should be given to limit the abundance of hydrodynamic-resistant pathogenic bacteria. GRAPHICAL ABSTRACT
- 28 October 2021
- Published by Taylor & Francis in Environmental Technology
- Vol. 44 (7) , 1018-1026
The role of hygrodynamic resistance compared to biofilm formation in helping pathogenic bacteria dominate air-conditioning units recovered from odour problems
Our previous study (Ng et al., 2018) proposed to install filters in odorous air-conditioning units (ACUs) to block the entry of skin squames. This approach has well tackled the odor problems and no further report regarding smelly ACUs has been received. In this study, we revisited and sampled the ACUs installed with filters earlier to study the bacterial communities inside the ACUs using 16S amplicon sequencing. We identified 26 genera and found that the skin bacteria isolated in the previous work were absent in this study. Two pathogenic bacteria, Methylobacterium and Sphingomonas, dominated ACUs instead. Afterward, these two bacteria were identified to species level (Methylobacterium organophilum and Sphingomonas paucimobilis, respectively), and examined in terms of their biofilm formation ability and resistance to changing moisture conditions together with another prevalent species isolated in our previous study, namely Micrococcus luteus, in order to understand the mechanisms of the survival of bacteria in ACUs. In general, M. organophilum and M. luteus showed good biofilm formation ability at all tested temperature levels, but S. paucimobilis only displayed limited biofilm formation. Whereas, all these three bacteria well maintained their survival after wet-dry cycles. These results suggest that compared to biofilm formation, ability to survive under hygrodynamics tends to play a more important role in helping bacteria dominate ACUs. Further, this study implies that the absence of odor problem does not guarantee a healthy environment, more attentions should be given to limit the abundance of hydrodynamic-resistant pathogenic bacteria. GRAPHICAL ABSTRACT
- Open Access
- 17 March 2020
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 70 (6) , 396-406
Current challenges for shaping the sustainable and mold-free hygienic indoor environment in humid regions
Indoor mold grows ubiquitously in humid areas and can affect occupants’ health. To prevent indoor mold contamination, one of the key measures suggested by the World Health Organisation and United States Environmental Protection Agency is to maintain an indoor relative humidity (RH) level below 75% or at 30–60%, respectively. However, in tropical and subtropical areas, maintaining these suggested RH levels is equivalent to operating a 24-h air-conditioner (AC) or dehumidifier, which is energy-consuming. As a large part of building expense, the operation time of ACs has been regularly proposed to be cut down because of the requirement of building sustainability. This leads to a trade-off between sustainable building performance and indoor mold hygiene. To balance this trade-off, more sustainable alternatives, such as those that target physical environments (e.g. nutrient and temperature level) or apply new surface coating technologies to inhibit mold growth, have been launched. Despite these initiatives, indoor mold contamination remains an unresolved issue, mainly because these alternative measures only exhibit limited effectiveness or require extra effort. This review aims to summarize the currently adopted mold control measures and discuss their limitations as well as the direction for the future development of sustainable mold control strategies. Significance and Impact of the Study: People spend most of their time indoors and hence the presence of indoor mold contamination can compromise the occupants’ health. With the wake of climate change which is expected to see an increase in RH and temperature, tropical and subtropical areas are even more prone to mold contamination than they used to be. This study may help facilitate the development of sustainable and effective mold control strategies in the indoor environment.
- 17 March 2020
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 70 (6) , 396-406
Open AccessCurrent challenges for shaping the sustainable and mold-free hygienic indoor environment in humid regions
Indoor mold grows ubiquitously in humid areas and can affect occupants’ health. To prevent indoor mold contamination, one of the key measures suggested by the World Health Organisation and United States Environmental Protection Agency is to maintain an indoor relative humidity (RH) level below 75% or at 30–60%, respectively. However, in tropical and subtropical areas, maintaining these suggested RH levels is equivalent to operating a 24-h air-conditioner (AC) or dehumidifier, which is energy-consuming. As a large part of building expense, the operation time of ACs has been regularly proposed to be cut down because of the requirement of building sustainability. This leads to a trade-off between sustainable building performance and indoor mold hygiene. To balance this trade-off, more sustainable alternatives, such as those that target physical environments (e.g. nutrient and temperature level) or apply new surface coating technologies to inhibit mold growth, have been launched. Despite these initiatives, indoor mold contamination remains an unresolved issue, mainly because these alternative measures only exhibit limited effectiveness or require extra effort. This review aims to summarize the currently adopted mold control measures and discuss their limitations as well as the direction for the future development of sustainable mold control strategies. Significance and Impact of the Study: People spend most of their time indoors and hence the presence of indoor mold contamination can compromise the occupants’ health. With the wake of climate change which is expected to see an increase in RH and temperature, tropical and subtropical areas are even more prone to mold contamination than they used to be. This study may help facilitate the development of sustainable and effective mold control strategies in the indoor environment.
- 16 October 2019
- Published by Wiley in Indoor Air
- Vol. 30 (1) , 117-125
The role of oxidative stress in the growth of the indoor moldCladosporium cladosporioidesunder water dynamics
Moisture is one of the critical abiotic factors that can affect mould growth. Indoor humidity is typically fluctuating, which renders a transient water supply for mould growth. Understanding mould growth under water dynamics and its underlying mechanisms can help in the development of novel and sustainable mould prevention strategies. In this study, pre‐germination and germinated spores of Cladosporium cladosporioides were exposed to daily wet–dry cycles with different combinations of wetting and drying duration. Afterwards, growth delay, cellular H2O2 concentration and catalase (CAT) activity were measured and compared. We found that under wet–dry cycles, the longer the growth delay was observed, the higher the cellular H2O2 concentration was detected, with the 12–12 wet–dry cycle (12‐h‐wet and 12‐h‐dry) showing the longest growth delay and highest cellular H2O2 production. A positive correlation between cellular H2O2 concentration and growth delay was suggested by Pearson correlation coefficient and linear regression analysis (p < 0.0001, R2 = 0.85). Furthermore, under wet–dry cycles, moulds derived from pre‐germination spores generally exhibited shorter growth delay, lower cellular H2O2 concentration and higher CAT activity than moulds developed from germinated spores. These results together suggest that the growth delay of C. cladosporioides under water dynamics is associated with oxidative stress.
- 16 October 2019
- Published by Wiley in Indoor Air
- Vol. 30 (1) , 117-125
The role of oxidative stress in the growth of the indoor moldCladosporium cladosporioidesunder water dynamics
Moisture is one of the critical abiotic factors that can affect mould growth. Indoor humidity is typically fluctuating, which renders a transient water supply for mould growth. Understanding mould growth under water dynamics and its underlying mechanisms can help in the development of novel and sustainable mould prevention strategies. In this study, pre‐germination and germinated spores of Cladosporium cladosporioides were exposed to daily wet–dry cycles with different combinations of wetting and drying duration. Afterwards, growth delay, cellular H2O2 concentration and catalase (CAT) activity were measured and compared. We found that under wet–dry cycles, the longer the growth delay was observed, the higher the cellular H2O2 concentration was detected, with the 12–12 wet–dry cycle (12‐h‐wet and 12‐h‐dry) showing the longest growth delay and highest cellular H2O2 production. A positive correlation between cellular H2O2 concentration and growth delay was suggested by Pearson correlation coefficient and linear regression analysis (p < 0.0001, R2 = 0.85). Furthermore, under wet–dry cycles, moulds derived from pre‐germination spores generally exhibited shorter growth delay, lower cellular H2O2 concentration and higher CAT activity than moulds developed from germinated spores. These results together suggest that the growth delay of C. cladosporioides under water dynamics is associated with oxidative stress.
- Open Access
- 4 April 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (4) , 681
Environmental Sustainability and Mold Hygiene in Buildings
Environmental sustainability is one of the key issues in building management. In Hong Kong, one of the initiatives is to reduce the operation hours of air-conditioning in buildings to cut down energy consumption. In this study, we reported a mold contamination case in a newly refurbished laboratory, in which the air-conditioner was switched from 24- to 18-h mode after refurbishment. In order to prevent mold recurrence, the air-conditioner was switched back to 24-h mode in the laboratory. During the mold investigation, visible mold patches in the laboratory were searched and then cultured, counted and identified. Building and environmental conditions were recorded, and used to deduce different causes of mold contamination. Eight contaminated sites including a wall, a bench, some metal and plastic surfaces and seven types of molds including two Cladosporium spp., two Aspergillus spp., one Rhizopus sp., one Trichoderma sp., and one Tritirachium sp. were identified. Cladosporium spp. were the most abundant and frequently found molds in the laboratory. The contaminated areas could have one to five different species on them. Based on the mold and environmental conditions, several scenarios causing the mold contamination were deduced, and different mold control measures were discussed to compare them with the current solution of using 24-h air-conditioning to control mold growth. This study highlights the importance of mold hygiene in sustainable building management.
- 4 April 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (4) , 681
Open AccessEnvironmental Sustainability and Mold Hygiene in Buildings
Environmental sustainability is one of the key issues in building management. In Hong Kong, one of the initiatives is to reduce the operation hours of air-conditioning in buildings to cut down energy consumption. In this study, we reported a mold contamination case in a newly refurbished laboratory, in which the air-conditioner was switched from 24- to 18-h mode after refurbishment. In order to prevent mold recurrence, the air-conditioner was switched back to 24-h mode in the laboratory. During the mold investigation, visible mold patches in the laboratory were searched and then cultured, counted and identified. Building and environmental conditions were recorded, and used to deduce different causes of mold contamination. Eight contaminated sites including a wall, a bench, some metal and plastic surfaces and seven types of molds including two Cladosporium spp., two Aspergillus spp., one Rhizopus sp., one Trichoderma sp., and one Tritirachium sp. were identified. Cladosporium spp. were the most abundant and frequently found molds in the laboratory. The contaminated areas could have one to five different species on them. Based on the mold and environmental conditions, several scenarios causing the mold contamination were deduced, and different mold control measures were discussed to compare them with the current solution of using 24-h air-conditioning to control mold growth. This study highlights the importance of mold hygiene in sustainable building management.
- 12 November 2017
- Published by Wiley in Indoor Air
- Vol. 28 (2) , 258-265
Skin squames contribute to ammonia and volatile fatty acid production from bacteria colonizing in air-cooling units with odor complaints
One of the most notable Indoor Air Quality problems is odor emission. This study investigated the potential contribution of skin squames to the production of ammonia (NH3) and volatile organic acids (VFAs) by 7 bacteria isolated from air‐cooling (AC) units with complaints of urine and body odors. Our previous study showed that keratinolytic activity is higher in AC units with odor complaints than those without. In the offices where these units are located, the most likely source of keratins is from human skin squames. Most bacteria can produce NH3 and VFAs in the skin squame culture. Some correlations between the levels of NH3, , VFAs, and keratinolytic activity were found. The odor production pathway with skin squames was proposed. Staphylococcus haemolyticus was abundant in the AC units with odor problems and had a high level of keratinolytic activity in addition to odor production. For long‐term odor control, it is important to reduce the level of skin squames entering the AC units.
- 12 November 2017
- Published by Wiley in Indoor Air
- Vol. 28 (2) , 258-265
Skin squames contribute to ammonia and volatile fatty acid production from bacteria colonizing in air-cooling units with odor complaints
One of the most notable Indoor Air Quality problems is odor emission. This study investigated the potential contribution of skin squames to the production of ammonia (NH3) and volatile organic acids (VFAs) by 7 bacteria isolated from air‐cooling (AC) units with complaints of urine and body odors. Our previous study showed that keratinolytic activity is higher in AC units with odor complaints than those without. In the offices where these units are located, the most likely source of keratins is from human skin squames. Most bacteria can produce NH3 and VFAs in the skin squame culture. Some correlations between the levels of NH3, , VFAs, and keratinolytic activity were found. The odor production pathway with skin squames was proposed. Staphylococcus haemolyticus was abundant in the AC units with odor problems and had a high level of keratinolytic activity in addition to odor production. For long‐term odor control, it is important to reduce the level of skin squames entering the AC units.