Sebastian Alphonse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastian Alphonse has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Geoffrey A. Williamson
Dept. of Elec. and Comp. Engr. Illinois Institute of Technology Chicago, IL, U.S.A.
2 shared publicationsAaron J. Polichnowski
Department of Biomedical Sciences East Tennessee State University, Johnson City, TN, U.S.A.
1 shared publicationAnil K. Bidani
Departments of Medicine Loyola Univ. Med. Ctr. and Edward Hines, Jr. VA Hosp. Maywood, IL, U.S.A.
1 shared publicationBecca Slepian
University of Arizona
1 shared publication- Brett M. Meyer
Medidata Solutions
1 shared publication - Daniel Lachant
Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Rochester Medical Center, Rochester, New York
1 shared publication
Latest Publications
- Open Access
Sensor Estimated Home 6-Minute Walk Distance and Cardiac Effort in Pulmonary Hypertension and Heart Failure
Background: Sensor-based estimation of six-minute walk distance and Cardiac Effort, number of heartbeats during the walk divided by distance walked, can be measured in the home. This study aimed to evaluate 1) the impact of walking course length on walk distance and Cardiac Effort, and 2) assess changes over time in a cohort of pulmonary hypertension and heart failure participants. Methods: This was a prospective observational study conducted at two sites. Participants included pulmonary hypertension, heart failure, and healthy controls. All participants wore chest-based sensors capable of recording accelerometry and electrocardiographic data. At baseline visit, participants performed a six-minute walk test on both a 90-ft and a 30-ft course, separated by 30-minutes rest. Unsupervised home walk tests were performed on the following two days. All assessments were repeated eight weeks later. Walk distance and Cardiac Effort were measured using three methods: direct observation, lap count estimation, and a signal-derived method based on mean amplitude deviation. Comparisons between clinic and home-based measurements were made using paired t-tests, correlation analysis, and Bland-Altman testing. Results: Sixty-six participants were enrolled, including 42 with pulmonary hypertension or heart failure and 24 controls. Walk distance on the 90-foot course was 10.7 percent longer than on the 30-ft course. Home-based walk distance was similar to the 30-ft course but lower than the 90-ft course. Home Cardiac Effort was similar to in-clinic values and tracked with changes over time. Conclusion: Home-based functional testing incorporating Cardiac Effort may offer a simple and effective remote metric to improve management of patients with heart failure.
Open AccessSensor Estimated Home 6-Minute Walk Distance and Cardiac Effort in Pulmonary Hypertension and Heart Failure
Background: Sensor-based estimation of six-minute walk distance and Cardiac Effort, number of heartbeats during the walk divided by distance walked, can be measured in the home. This study aimed to evaluate 1) the impact of walking course length on walk distance and Cardiac Effort, and 2) assess changes over time in a cohort of pulmonary hypertension and heart failure participants. Methods: This was a prospective observational study conducted at two sites. Participants included pulmonary hypertension, heart failure, and healthy controls. All participants wore chest-based sensors capable of recording accelerometry and electrocardiographic data. At baseline visit, participants performed a six-minute walk test on both a 90-ft and a 30-ft course, separated by 30-minutes rest. Unsupervised home walk tests were performed on the following two days. All assessments were repeated eight weeks later. Walk distance and Cardiac Effort were measured using three methods: direct observation, lap count estimation, and a signal-derived method based on mean amplitude deviation. Comparisons between clinic and home-based measurements were made using paired t-tests, correlation analysis, and Bland-Altman testing. Results: Sixty-six participants were enrolled, including 42 with pulmonary hypertension or heart failure and 24 controls. Walk distance on the 90-foot course was 10.7 percent longer than on the 30-ft course. Home-based walk distance was similar to the 30-ft course but lower than the 90-ft course. Home Cardiac Effort was similar to in-clinic values and tracked with changes over time. Conclusion: Home-based functional testing incorporating Cardiac Effort may offer a simple and effective remote metric to improve management of patients with heart failure.
- 24 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in European Signal Processing Conference (EUSIPCO)
- Vol. 2020, 1165-1169
Autoregulatory Efficiency Assessment in Kidneys Using Deep Learning
A convolutional deep neural network is employed to assess renal autoregulation using time series of arterial blood pressure and blood flow rate measurements in conscious rats. The network is trained using representative data samples from rats with intact autoregulation and rats whose autoregulation is impaired by the calcium channel blocker amlodipine. Network performance is evaluated using test data of the types used for training, but also with data from other models for autoregulatory impairment, including different calcium channel blockers and also renal mass reduction. The network is shown to provide effective classification for impairments from calcium channel blockers. However, the assessment of autoregulation when impaired by renal mass reduction was not as clear, evidencing a different signature in the hemodynamic data for that impairment model. When calcium channel blockers were given to those animals, however, the classification again was effective.
- 24 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in European Signal Processing Conference (EUSIPCO)
- Vol. 2020, 1165-1169
Autoregulatory Efficiency Assessment in Kidneys Using Deep Learning
A convolutional deep neural network is employed to assess renal autoregulation using time series of arterial blood pressure and blood flow rate measurements in conscious rats. The network is trained using representative data samples from rats with intact autoregulation and rats whose autoregulation is impaired by the calcium channel blocker amlodipine. Network performance is evaluated using test data of the types used for training, but also with data from other models for autoregulatory impairment, including different calcium channel blockers and also renal mass reduction. The network is shown to provide effective classification for impairments from calcium channel blockers. However, the assessment of autoregulation when impaired by renal mass reduction was not as clear, evidencing a different signature in the hemodynamic data for that impairment model. When calcium channel blockers were given to those animals, however, the classification again was effective.
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 57 (3) , 1793-1802
On Estimating Nonlinear Frequency Modulated Radar Signals in Low SNR Environments
Estimating the signal transmitted by a noncooperating radar is of great use in radar countermeasures. In this paper we propose to improve noise resilience of the radar signal estimation by constraining the estimate to be in a low dimensional signal space. In particular we focus on estimating Nonlinear Frequency Modulated (NLFM) radar signals that have good target resolution characteristics. A flexible three dimensional, odd polynomial frequency signal (3D-OPFS) model is introduced as the low dimensional signal space to compute accurate estimates at low signal to noise ratios (SNRs) with small number of intercepted signals. The quality of the low dimensional signal estimates is compared with that of the estimate from the unconstrained high dimensional space computed using principal component analysis (PCA) estimator which is the method in predominant use in the multi-sensor scenario. It is shown that signal estimation through low dimensional signal spaces yields more accurate estimates at low SNRs with a smaller number of sensors compared to searching in the unconstrained high dimensional signal space.
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 57 (3) , 1793-1802
On Estimating Nonlinear Frequency Modulated Radar Signals in Low SNR Environments
Estimating the signal transmitted by a noncooperating radar is of great use in radar countermeasures. In this paper we propose to improve noise resilience of the radar signal estimation by constraining the estimate to be in a low dimensional signal space. In particular we focus on estimating Nonlinear Frequency Modulated (NLFM) radar signals that have good target resolution characteristics. A flexible three dimensional, odd polynomial frequency signal (3D-OPFS) model is introduced as the low dimensional signal space to compute accurate estimates at low signal to noise ratios (SNRs) with small number of intercepted signals. The quality of the low dimensional signal estimates is compared with that of the estimate from the unconstrained high dimensional space computed using principal component analysis (PCA) estimator which is the method in predominant use in the multi-sensor scenario. It is shown that signal estimation through low dimensional signal spaces yields more accurate estimates at low SNRs with a smaller number of sensors compared to searching in the unconstrained high dimensional signal space.
- Open Access
- 21 December 2019
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2019 (1) , 1-12
Evaluation of a class of NLFM radar signals
Signal design is an important component for good performance of radar systems. Here, the problem of determining a good radar signal with the objective of minimizing autocorrelation sidelobes is addressed, and the first comprehensive comparison of a range of signals proposed in the literature is conducted. The search is restricted to a set of nonlinear, frequency-modulated signals whose frequency function is monotonically nondecreasing and antisymmetric about the temporal midpoint. This set includes many signals designed for smaller sidelobes including our proposed odd polynomial frequency signal (OPFS) model and antisymmetric time exponentiated frequency modulated (ATEFM) signal model. The signal design is optimized based on autocorrelation sidelobe levels with constraints on the autocorrelation mainlobe width and leakage of energy outside the allowed bandwidth, and we compare our optimized design with the best signal found from parameterized signal model classes in the literature. The quality of the overall best such signal is assessed through comparison to performance of a large number of randomly generated signals from within the search space. From this analysis, it is found that the OPFS model proposed in this paper outperforms all other contenders for most combinations of the objective functions and is expected to be better than nearly all signals within the entire search set.
- 21 December 2019
- Published by Springer Nature in EURASIP Journal on Advances in Signal Processing
- Vol. 2019 (1) , 1-12
Open AccessEvaluation of a class of NLFM radar signals
Signal design is an important component for good performance of radar systems. Here, the problem of determining a good radar signal with the objective of minimizing autocorrelation sidelobes is addressed, and the first comprehensive comparison of a range of signals proposed in the literature is conducted. The search is restricted to a set of nonlinear, frequency-modulated signals whose frequency function is monotonically nondecreasing and antisymmetric about the temporal midpoint. This set includes many signals designed for smaller sidelobes including our proposed odd polynomial frequency signal (OPFS) model and antisymmetric time exponentiated frequency modulated (ATEFM) signal model. The signal design is optimized based on autocorrelation sidelobe levels with constraints on the autocorrelation mainlobe width and leakage of energy outside the allowed bandwidth, and we compare our optimized design with the best signal found from parameterized signal model classes in the literature. The quality of the overall best such signal is assessed through comparison to performance of a large number of randomly generated signals from within the search space. From this analysis, it is found that the OPFS model proposed in this paper outperforms all other contenders for most combinations of the objective functions and is expected to be better than nearly all signals within the entire search set.