EAEhsan Ashoori

Ehsan Ashoori

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ehsan Ashoori has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Distinguishable Multi-Layer Frequency-Modulated Waveforms for Peripheral Nerve Communication in Human Augmentation Applications

    by Sina Parsnejad, Ehsan Ashoori, Sylmarie Dávila-Montero, Andrew J. Mason

    Recent advancements in sensing, information processing, and actuation technologies have catalyzed significant research and commercial interest in human augmentation. Currently, human augmentation technologies are proficient at extracting information but lack diversity of means for machine-to human communication (M2HC). Hence, this paper explores using electrotactile stimulation of the human peripheral nervous system as an alternative channel for M2HC. Electrotactile stimulation can create distinct sensations, usually in the form of vibration frequency or intensity, and each distinct sensation can be used to communicate information to a trained user in the form of icons. To maximize the number of distinct sensations that can be created, this paper proposes a model for electrotactile waveforms generation (MEWS) that overlays two frequencies over a 2kHz carrier biphasic electrotactile waveform creating new distinct sensations. To better understand MEWS, four double blinded experiments were conducted on volunteers. Experiments I-III were done to study MEWS capabilities and limitations. Experiment IV was performed to create a list of reliably distinct waveforms using insights from experiments I-III. The results showed that using MEWS and only using a single electrode it is possible to create 13 reasonably distinct waveforms with an accuracy of 85% over a 500ms long stimulation window.


  • Open Access

    Wide Voltage Swing Potentiostat with Dynamic Analog Ground to Expand Electrochemical Potential Windows in Integrated Microsystems

    by Ehsan Ashoori, Derek Goderis, Anna Inohara, Andrew J. Mason

    Electrochemical measurements are vital to a wide range of applications such as air quality monitoring, biological testing, food industry, and more. Integrated circuits have been used to implement miniaturized and low-power electrochemical potentiostats that are suitable for wearable devices. However, employing modern integrated circuit technologies with low supply voltage precludes the utilization of electrochemical reactions that require a higher potential window. In this paper, we present a novel circuit architecture that utilizes dynamic voltage at the working electrode of an electrochemical cell to effectively enhance the supported voltage range compared to traditional designs, increasing the cell voltage range by 46% and 88% for positive and negative cell voltages, respectively. In return, this facilitates a wider range of bias voltages in an electrochemical cell, and, therefore, opens integrated microsystems to a broader class of electrochemical reactions. The circuit was implemented in 180 nm technology and consumes 2.047 mW of power. It supports a bias potential range of 1.1 V to −2.12 V and cell potential range of 2.41 V to −3.11 V that is nearly double the range in conventional designs.


  • Neurochemical Sensing

    by Ehsan Ashoori, Sina Parsnejad, Andrew J. Mason

  • Highly Linear Low Power V-Band Down-Conversion Mixer in SiGe BiCMOS Technology

    by Zahra Marvi, Ehsan Ashoori

    This paper presents a V-band Gilbert-cell down-conversion mixer implemented in 0.13um SiGe BiCMOS process. The mixer consists of a double-balanced Gilbert-cell, on-chip transformer-type baluns for the RF and LO ports, and matching networks. The performance of the mixer is optimized to achieve high linearity, low noise and low power consumption. Based on the measurement results, 1-dB input compression point of 11dBm is obtained at 60 GHz with conversion gain of -9.5 dB with overall DC power consumption of 17.7 mW. The maximum gain of -6.5 dB is achieved at 53 GHz with 3-dB RF bandwidth of 50-60 GHz for LO drive of -2 dBm. IF 3-dB bandwidth is around 5.5 GHz. The chip occupies the area of 483 μm by 482 μm. The mixer has simulated noise figure of 9.5dB. The mixer achieves performance comparable to state-of-the-art V-band mixers with high linearity and low power consumption.


  • Early Detection of Epileptic Activity on EEG Signals using Phase-Preserving Quantization Method

    by Sylmarie Davila-Montero, Ehsan Ashoori, Andrew J. Mason

    This paper demonstrates the use of a data decimation method, called phase-preserving quantization (PPQ), for early seizure prediction. PPQ consists of a) amplifying and filtering the neural signals around the frequency band of interest, and b) compressing the filtered signal using a 1-bit quantizer with a 0-V single-threshold decision. The ability of PPQ to retain phase information and predict seizure events while compressing the signal resolution to a single bit is demonstrated using electroencephalography (EEG) recordings from the Children's Hospital Boston-MIT (CHB-MIT) EEG database. Results show 97% accuracy when calculating synchrony values using PPQ, which is an improvement of 7% when compared to previously published results. The presented improved method enables the early detection of seizure events, resulting in a decrease in phase synchrony computation time while allowing an increase in the number of recording channels that can be screened when using EEG.


  • ECoG Electrode Array with Embedded Coupling Capacitors for Area Efficient Neural Recording

    by Ehsan Ashoori, Heyu Yin, Sina Parsnejad, Joseph W. Salatino, Erin K. Purcell, Andrew J. Mason

    ECoG electrode arrays offer great potential for high-channel-count monitoring of large scale brain activity. However, scaling ECoG recording systems to high channel count is challenging due to the large silicon area demanded by the coupling capacitors necessary for DC offset voltage rejection. This paper presents a new approach to reduce the per-channel area of recording circuits by introducing a capacitor-embedded ECoG electrode structure that implements coupling capacitors within the existing electrode area. For proof of concept, a 4×4 array of 8 pF capacitor-embedded electrodes was fabricated in a 2mm × 2mm area using a three-mask process to form a capacitor stack of Cu, Ta 2 O 5 , and Ti/Cu/ Au. In vivo experiments performed on an adult rat show that physiologically-evoked activity was accurately detected according to the placement of the electrodes for manual whisker deflection, shoulder tapping and hindlimb tapping. The capacitor-embedded ECoG electrode structure provides a new method for achieving high channel count neural recording.


  • Compact and Low Power Analog Front End with in-situ Data Decimator for High-Channel-Count ECoG Recording

    by Ehsan Ashoori, Sylmarie Davila-Montero, Andrew J. Mason

    High channel count neural implants that can record brain activities across diverse cortical regions represent the next step toward whole brain interfaces that will enable new understanding of brain operation and treatment of many neural disorders. To overcome the size and power constraints limiting the channel count of existing neural implants, this paper presents a new neural amplifier array design that utilizes hardware sharing to achieve low power and compact size. Moreover, to ease the burden of large volume data handling, in-situ data decimation is performed to enable off body evaluation of synchrony between signal pairs. A 32-channel analog front end array was designed and post-layout simulations show that the entire front end occupies only 0.031 mm 2 per channel while consuming only 3.34 μW per channel at 3.3 V in 0.5 μm CMOS. This front end decimates data by an order of magnitude while keeping the synchrony information with more than 89.1% accuracy.


  • Open Access

    Ultracompact Microwatt CMOS Current Readout With Picoampere Noise and Kilohertz Bandwidth for Biosensor Arrays

    by Haitao Li, Sina Parsnejad, Ehsan Ashoori, Cort Thompson, Erin K. Purcell, Andrew J. Mason

    High-density on-chip electrochemical biosensor arrays are advancing toward a crucial role in health monitoring and development of new medicines and medical treatments. Nanopore and ion channel based sensors especially have great potential but present demanding resolution/speed/power/area requirements on instrumentation circuits. This paper presents a pixel-level current readout circuit and new group-cluster architecture to address the circuit challenges in high-performance biosensor arrays. Fabricated in 0.5 μm CMOS, this electrochemical voltammetry circuit achieves 7.2 pArms noise in an 11.5-kHz bandwidth and only consumes 21-μ W power and 0.06 mm 2 area per readout channel. Cyclic voltammetry experiments in a potassium ferricyanide solution and patch-clamp whole-cell experiments were performed to validate the circuit's feasibility for electrochemical biosensor applications.


  • Concentric helical coils for efficient and resilient wireless link in biomedical implants

    by Ehsan Ashoori, Andrew J. Mason

    Wireless transceivers for biomedical implants suffer from low coupling coefficients and variations due to misalignment. This paper introduces concentric helical coils for wireless power transmission in implantable devices. The transmitter coil can be implemented in any continuous circle form, such as a bracelet, an arm cuff, or a collar. It is shown that this structure produces a high coupling coefficient that is less sensitive than conventional methods to coil misalignment. Furthermore, this approach reduces expose of living tissue to electromagnetic power density, enabling a higher level of power to be safely transferred. A high coupling coefficient between transmitter and receiver coils (k=0.44) is achieved, and this decreases no more than 19.9% with the worst case of misalignment. This high coupling along with high coil quality factors (Q=470, 195) enable a high power transfer efficiency of η=93.6%. This power transfer efficiency is also very resilient to misalignment of coils, with a worst case decrease of only 9%.

  • Wide dynamic range multi-channel electrochemical instrument for in-field measurements

    by Sina Parsnejad, Yaoxing Hu, Hao Wan, Ehsan Ashoori, Andrew J. Mason

    This paper presents a multi-channel, multi-technique electrochemical instrument with the size, power and performance for portable applications such as point-of-care diagnosis, wearable sensing, and toxic chemical detection. Composed of a custom analog interface and a commercial low-power microcontroller, the portable instrument is capable of dynamically adapting to a wide input current range exhibited by many electrode/sensor types and observed in the transient response of many electrochemical techniques. The instrument can generate several standard electrochemical stimulus waveforms or an arbitrary waveform, independently and in parallel on multiple channels, while streaming measurement results to a USB host. The portable instrument was tested across multiple conditions against a commercial benchtop electrochemical instrument in a potassium ferricyanide solution. The maximum normalized root mean square difference between test results and the commercial instrument is less than 2%, cementing system robustness.